Pick your language and provide your email: we'll send you a specifically translated version.
Product type Submersible pump / Dirty water pump
Model SP 16.000 Flood Box
Brand Kärcher
Max flow rate 16,000 l/h
Max head 8 m
Max pressure 0.8 bar (0.08 MPa)
Max immersion depth 7 m
Permissible pumping media Fresh water, slightly dirty water (particles up to 20 mm), swimming pool water, washing lye
Medium temperature 5 °C to 35 °C
Rated voltage 230-240 V
Mains frequency 50 Hz
Rated power 550 W
Weight (without accessories) 4.9 kg
Protection class IPX8 (permanently under water)
Cable connection Power cable with plug, length not specified (typically 10 m)
Float switch Yes, height-adjustable for automatic operation
Connection options Quick-connect system for hoses 1", 1 ¼", 1 ½"; optional G 1" with check valve
Residual water level (manual) 25 mm
Minimum liquid level (manual) 60 mm
Scope of delivery Pump, connecting piece G 1 ½, pump connection piece, instruction manual
Maintenance Maintenance-free; rinse with clean water after use
Suitable for Flooding, tank emptying, wells, boats
Warranty Manufacturer's warranty according to Kärcher conditions

Frequently Asked Questions - SP 16.000 Flood Box Kärcher

Which liquids can the Kärcher SP 16.000 Flood Box pump?
The pump is suitable for fresh water, slightly dirty water (particles up to 20 mm), swimming pool water with correct dosing of additives, and washing lye. Not suitable for explosive, flammable, or corrosive liquids, fats, oils, salt water, and toilet wastewater.
What are the maximum flow rate and head?
The maximum flow rate is 16,000 l/h, the maximum head is 8 m. Actual performance depends on hose diameter and length.
Can the pump run continuously?
No, the pump is not designed for continuous operation (e.g., circulation in ponds) or stationary installation. Continuous operation may cause damage.
How do I connect the hose to the pump?
The pump has a Quick-Connect system. Screw the pump connection piece G 1 ½ onto the connecting piece, slide the hose onto the piece and secure it with a hose clamp. Then insert the connecting piece into the Quick-Connect until it clicks into place.
Does the pump work automatically?
Yes, in automatic mode, the float switch turns the pump on when the liquid level reaches the switch-on height and turns it off when it falls below the switch-off height. The float height adjustment can be customized.
How deep can the pump be submerged?
The maximum immersion depth is 7 m.
What to do if the pump runs but does not pump?
Possible causes: air in the pump (unplug and replug several times), clogged suction area (clean), liquid level too low in manual operation (immerse pump deeper).
How do I clean the pump after use?
After pumping dirty water or water with additives, immediately rinse with clean fresh water. To do this, run the pump with clean water, then unplug and clean the connections. Wipe the outside with a soft cloth.
Is frost protection necessary?
Yes, the pump must be protected from frost. Empty and dry it completely before storage, keep in a frost-free place. Frost can cause damage.
Which accessories are available?
Original Kärcher accessories, e.g., a pump connection piece G 1 (6.997-359.0) with check valve for smaller hoses, and a pre-filter for finer particles. Information at www.kaercher.com.

User questions about SP 16.000 Flood Box Kärcher

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Pump in PDF format for free! Find your manual SP 16.000 Flood Box - Kärcher and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SP 16.000 Flood Box by Kärcher.

USER MANUAL SP 16.000 Flood Box Kärcher

natural_image Yellow and black KKRCHER water purifier device (no visible text or symbols on body)

Kärcher SP 16.000 Flood Box - 1

natural_image Yellow Kürcher water purifier with black base and hose (no visible text or symbols)

Deutsch 4

English 8

Français 13

Italiano 18

Nederlands 23

Español 28

Português 32

Dansk 37

Norsk 42

Svenska 46

Suomi 50

Ελληνικά 55

Türkçe 60

Русский 64

Magyar 70

Čeština 74

Slovenščina 79

Polski 83

Românește 88

Slovenčina 93

Hrvatski 98

Srpski 102

Български 107

Eesti 112

Latviešu 116

Lietuviškai 121

Українська 125

Қазақша 130

日本語 135

العربيya 141

A
SP 16.000 Dirt
KARCHER ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬

SP 22.000 Dirt
KARCHER 1 2 3 4 5 6 7 8 9 13

B 1" & 1¼" & 1½" 2 3 1 ¾" & 1" 3 4 2 1

Kärcher SP 16.000 Flood Box - 5

natural_image 3D mechanical component diagram showing a pipe fitting with arrows indicating assembly or movement (no text or symbols)

Kärcher SP 16.000 Flood Box - 6

natural_image Close-up of a mechanical component with a black arrow pointing to a connector (no text or symbols visible)

Kärcher SP 16.000 Flood Box - 7

natural_image 3D model of a mechanical component with yellow and gray surfaces, showing a black arrow pointing to a specific part (no text or symbols present)

Kärcher SP 16.000 Flood Box - 8

natural_image Illustration of a yellow underwater spray gun with a water level sensor and height measurement arrow (no text or symbols)

Kärcher SP 16.000 Flood Box - 9

natural_image Illustration of a yellow and gray water purifier with a submerged device, showing water level and height measurement (no text or symbols)

Kärcher SP 16.000 Flood Box - 10

natural_image 3D rendered mechanical component with yellow and gray parts, no visible text or symbols

Inhalt

Kärcher SP 16.000 Flood Box - Inhalt - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Inhalt - 2
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tel.: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 2021/06/01

Contents

General notes.... 8

Intended use 8

Hazard levels 9

Environmental protection 9

Accessories and spare parts.... 9

Scope of delivery.... 9

Warranty....9

Device description....9

Initial startup.... 10

Operation 10

Care and maintenance.... 11

Transport.... 11

Storage.... 11

Troubleshooting guide.... 11

Technical data 12

Optimising the flow rate.... 12

Declaration of Conformity.... 12

General notes

Kärcher SP 16.000 Flood Box - General notes - 1

Read these original operating instructions and the enclosed safety instructions before using the device for the first

time. Proceed accordingly.

Keep both books for future reference or for future owners.

Intended use

Only use the device in private households.

Intended use:

  • Removal of water from building sections in the event of flooding
    • Transferring and pumping water from containers
    • Water removal from wells and shafts

- Pumping fresh water out of boats and yachts For notes on functional principle, see chapter Operation.

Permissible feed fluids

⚠️DANGER

Danger of death and risk of damage when pumping explosive, flammable or unsuitable substances!

Flammable or explosive substances may ignite or explode.

Unsuitable substances can damage the pump.

Do not pump explosive, flammable or corrosive liquids or gases (e.g. fuels, petroleum, nitro thinner) and do not pump fats, oils, salt water or waste water from sanitary facilities or water that has a lower flowing ability than clean water.

Permissible feed fluids:

- Fresh water up to a certain degree of soiling. SP 16000 Dirt:

Water with a degree of soiling up to grain size 20 mm

SP 22000 Dirt:

Water with a degree of soiling up to grain size 30 mm

  • Swimming pool water with intended dosage of additives.
  • Washing lye, e.g. from leaking washing machines. Then rinse and clean the pump with clear fresh water, see chapter Rinsing and cleaning.
  • The temperature of the pumped liquids must lie between 5 °C and 35 °C.

Improper use

ATTENTION

Risk of damage due to frost!

Operation during frost may damage the device.

An incompletely emptied device can be damaged by frost.

Do not operate the device during frost.

Protect the device from frost.

ATTENTION

Risk of damage during continuous operation!

The device is not suitable for continuous operation. Do not operate the device continuously for long periods (e.g. continuous circulation operation in ponds) or as a stationary installation (e.g. as a water lifting system, fountain pump).

Note

The manufacturer accepts no liability for possible damage caused by improper use or incorrect operation.

Hazard levels

⚠️DANGER

- Indication of an imminent threat of danger that will lead to severe injuries or even death.

⚠ WARNING

- Indication of a potentially dangerous situation that may lead to severe injuries or even death.

△CAUTION

- Indication of a potentially dangerous situation that may lead to minor injuries.

ATTENTION

- Indication of a potentially dangerous situation that may lead to damage to property.

Environmental protection

Kärcher SP 16.000 Flood Box - Environmental protection - 1

The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

Kärcher SP 16.000 Flood Box - Environmental protection - 2

Electrical and electronic appliances contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can

pose a potential threat to human health and the environment. However, these components are required for the correct operation of the appliance. Appliances marked by this symbol are not allowed to be disposed of together with the household rubbish.

Notes on the content materials (REACH)

Current information on content materials can be found at: www.kaercher.com/REACH

Accessories and spare parts

Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

Information on accessories and spare parts can be found at www.kaercher.com.

Scope of delivery

The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.

Warranty

The warranty conditions issued by our sales company responsible apply in all countries. We shall remedy possible malfunctions on your device within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

(See overleaf for the address)

Device description

See graphics page for illustrations Illustration A

① Carrying handle
② Power supply cable with plug
③ Automatic venting device
4 Quick-Connect

⑤ Pump connecting piece G 1 ½ (1", 1 ¼" and 1 ½" hose connection and G 1 ½ thread)

⑥ Connection nozzle (G 1 ½ thread)

⑦ Lock (float switch)

⑧ Height adjustment (float switch)

⑨ Float switch

⑩ *Pump connecting piece G 1 ( 34 " and 1" hose connection and G 1 thread)

⑪* Check valve

⑫G 1 Threaded connection (SP 16000 Dirt)

13 Pre-filter (SP 22000 Dirt)

*Not included in the scope of delivery.

Initial startup

⚠️DANGER

Risk of electric shock and risk of injury!

The device contains electrical and mechanical components.

Always disconnect the device from the power supply before assembling, disassembling or cleaning.

Note

The shorter the hose length and larger the hose diameter, the higher the delivery rate.

To avoid clogging the pump, use a pre-filter for hose diameters smaller than 1 14 ".

• SP 16000 Dirt Special accessories
• SP 22000 Dirt Integrated in the foot

The pump connection is equipped with a plug system (Quick-Connect).

The connection nozzle with pump connecting piece

G 1 12 and G 1 threaded connection are supplied unassembled with the device.

Note

Hoses with a diameter of 1", 1 ¼" and 1 ½" can be connected to the pump connecting piece G 1 ½.

A sufficiently large hose diameter must be selected and the G 1½ pump connecting piece must be shortened at the grooves so that the required particle size can be pumped. A large hose diameter is also recommended for smaller particle sizes to allow a high flow volume.

Connecting a hose to the pump when using a 1", 1 14 " or 1 12 " hose:

1 Screw the G 1 12 pump connecting piece onto the connection nozzle.

Illustration B

2 Push the hose clamp onto the hose.
3 Push the hose onto the G 1 12 pump connecting piece and fasten it with a hose clamp.
4 Push the connection nozzle into the Quick-Connect. Illustration C

Connecting a hose to the pump when using a 34 " or 1" hose (SP 16000 Dirt):

1 Screw the G 1 threaded connection onto the connection nozzle.
2 Fit the special accessory G 1 pump connecting piece(6.997-359.0 pump connecting piece G 1 (33.3 mm) incl. check valve - not included in the scope of delivery) onto the G 1 threaded connection:

a Place the check valve on the G 1 threaded connection so that the lettering "UP" is legible.

b Screw the pump connecting piece G 1 onto the G 1 threaded connection.

3 Push the hose clamp onto the hose.
4 Push the hose onto the pump connecting piece G 1 and fasten it with a hose clamp.
5 Push the connection nozzle into the Quick-Connect. Illustration C

Erecting/immersing the pump:

1 Fit the height adjustment of the float switch into the lock.

Illustration D

2 Place the pump securely on solid ground in the pumped liquid or immerse it via a rope attached to the carrying handle.

Note

The suction area must not be blocked by soiling. If the ground is muddy, place the pump on a brick or similar.

Make sure that the pump stands level. Do not carry the pump using the cable or hose.

Operation

⚠️DANGER

Danger of death from electric shock.

Danger of death from electric shock if live parts are touched.

During operation, do not touch the rope attached to the carrying handle or any objects that are in contact with the pumped liquid (e.g. pipelines protruding into the pumped liquid, railings) and do not reach into the pumped liquid.

Automatic venting device

  1. If the fluid level is low, any sucked-in air, or air present in the pump, may escape via the automatic venting device. Fluid can also leak along with air. If the pump has problems with suction when the fluid level is low, unplug and plug in the mains plug repeatedly to assist the suction process.

Illustration E

Automatic mode

  1. Adjust the float switch via the height adjustment and the cable length.

Note

If the pump is operated unattended, always set the float switch to the top position to ensure reliable pump switch-off.

Illustration F

Note

When the pump is set to the lowermost position, set the cable length between the float switch and the lock to 2.5 cm, see marking on the cable.

Illustration G

  1. Plug the mains plug into the socket.

Note

In automatic mode, the float switch controls the pumping process automatically.

The pump switches on as soon as the float switch reaches the switch-on height caused by the rising fluid level.

The pump switches off as soon as the float switch reaches the switch-off height caused by the sinking fluid level.

The float switch must be able to move freely.

The cable length between the float switch and the locking device must be at least 2.5 cm.

Switch-on height / switch-off height (float switch in lowest position):

Min / Max SP 16000 Dirt SP 22000 Dirt
Switch-on height cm*18 / 21 20 / 24
Switch-off height cm*4 / 12 6 / 15

Switch-on height / switch-off height (float switch in uppermost position):

Min / Max SP 16000 Dirt SP 22000Dirt
Switch-on height cm*28 / 31 33 / 36
Switch-off height cm*14 / 22 19 / 27

* The switching heights vary depending on the position of the float switch and the cable length between the float switch and the lock. We recommend retaining the set cable length.

Manual mode

Note

In manual mode, the pump stays switched on. The fluid level must be at least 60 mm (SP 16000 Dirt) or 50 mm (SP 22000 Dirt) for the pump to prime itself in manual mode. The pump can pump up to a residual fluid height of 25 mm (SP 16000 Dirt) or 35 mm (SP 22000 Dirt). The specified residual fluid height is only achieved in manual mode.

The float switch must be able to move freely.

  1. Fasten the float switch in the lock pointing upwards. Illustration H

ATTENTION

Risk of damage from dry running!

Dry running leads to increased wear on the pump. Do not leave the pump unattended in manual operation. In case of dry running, immediately pull the mains plug out of the socket.

  1. Plug the mains plug into a mains socket.

Finishing operation

  1. Pull the mains plug out of the socket. The device stops.

ATTENTION

Risk of damage!

Risk of damage due to dried soiling or additives. Rinse and clean the device immediately after each use.

  1. If dirty liquids or liquids with additives have been pumped, rinse and clean the device immediately after finishing operation, see chapter Rinsing and cleaning.

  2. Drain the device and accessories and let them dry.

Care and maintenance

⚠️DANGER

Risk of electric shock and risk of injury!

The device contains electrical and mechanical components.

Cleaning and user maintenance may not be carried out by children.

Rinsing and cleaning

ATTENTION

Risk of damage!

Risk of damage due to dried soiling or additives. Rinse and clean the device immediately after each use.

1 If dirty liquids or liquids with additives have been pumped, the device must be rinsed afterwards: Use the device to pump clear fresh water without additives until all soiling or additives have been flushed out of the device.

⚠️DANGER

Risk of electric shock and risk of injury!

The device contains electrical and mechanical components.

Always disconnect the device from the power supply before assembling, disassembling or cleaning.

2 Pull the mains plug out of the socket.

3 Press the Quick-Connect button and remove the connection nozzle.

Illustration C

4 Where necessary, remove residue from the hose and on Quick-Connect.

5 Clean the outside of the device with a soft, clean cloth and clear fresh water.

6 Drain the device and accessories and let them dry.

Service

The device is maintenance-free.

Transport

Manual transport

△CAUTION

Risk of injury from tripping!

There is a risk of injury from tripping on loose cables and hoses.

Be careful of cables and hoses when moving the device.

  1. Lift and carry the device by the carrying handle.

Transport in vehicles

⚠ WARNING

Risk of injury, risk of damage!

Note the weight of the device during transport.

Store or secure the device in accordance with applicable guidelines so that it cannot slip or be thrown around during transport.

  1. When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respectively applicable guidelines.

Storage

ATTENTION

Risk of damage due to frost!

An incompletely emptied device can be damaged by frost.

Completely empty the device and accessories before storing them.

Protect the device from frost.

Store the device in a frost-free place and not outdoors.

⚠CAUTION

Risk of injury and damage!

The device may tip over on sloping surfaces.

Be aware of the weight of the device during storage.

  1. Completely empty the pump and accessories.

  2. Allow the pump and accessories to dry out.

  3. Store the pump in a frost-protected place.

Troubleshooting guide

Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.

Fault Cause Rectification
The pump is running, but not deliveringAir is in the pump. 1. Pull the mains plugout of the socket and plug it in again several times, until the fluid is drawn in.
The suction area is clogged. 1. Pull the mains plug out of the socket.2. Clean the suction area.
The fluid level is too low in manual operation.1. Immerse the pump deeper into the feed fluid if possible, see chapter Operation.
The pump does not start up, or stops suddenly during operationThe power supply is disconnected. 1. Check the fuses and the electrical connections.
The thermal protection switch has switched off the pump because of overheating.1. Pull the mains plug out of the socket.2. Allow the pump to cool down.3. Remove any dirt particles in the suction area.4. Clean the suction area.5. Prevent the pump from running dry.
Dirt particles block the suction area. 1. Pull the mains plug out of the socket.2. Clean the suction area.
The pumping capacity decreasesThe suction area is clogged. 1. Pull the mains plug out of the socket.2. Clean the suction area.
The delivery rate is too lowThe maximum delivery head is exceeded.The hose diameter and the hose length have been selected incorrectly.1. Observe the maximum delivery head, see chapter Technical data.2. If necessary, select a greater hose diameter or a shorter hose length, see chapter Optimising the flow rate.
Quick-Connect cannot be opened or closedThe push-fit system is dirty. 1. Remove the clip.2. Clean the clip.3. Install the clip.

Technical data

SP16.000DirtSP22.000Dirt
Device performance data
Mains voltage V 230-240 230-240
Power frequency Hz 5050
Nominal powerW550750
Maximum flow ratel/h16.00022.000
Pressure (max.)MPa(bar)0,08(0,8)0,08(0,8)
Delivery height (max.) m 88
Immersion depth (max.)m 77
Perm. temp. feed fluid °C5...355...35
Particle size (max.) of permissible feed fluidsmm2030
Minimum fluid level (manual mode)mm6050
Residual fluid heightmm2535
Weight (without accessories)kg4,96,5

Subject to technical modifications.

Optimising the flow rate

The flow rate is further increased:

• The lifting height is reduced.
- The diameter of the hose used is increased.
• The length of the hose used is decreased.
- The smaller the pressure loss caused by the connected up accessories.

Kärcher SP 16.000 Flood Box - Optimising the flow rate - 1

line | l/h | SP 16.000 Dirt | SP 22.000 Dirt | | ------ | -------------- | -------------- | | 2.000 | 8.0 | 8.0 | | 6.000 | 7.5 | 7.8 | | 10.000 | 6.5 | 7.0 | | 14.000 | 4.5 | 5.5 | | 18.000 | 2.5 | 3.5 | | 22.000 | 1.0 | 1.0 |

Declaration of Conformity

EU Declaration of Conformity

We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.

Product: Pump

Type: 1.645-xxx

Currently applicable EU Directives

2014/35/EU

2014/30/EU

2011/65/EU

2009/125/EC

Commission Regulation(s)

(EU) 2019/1781

Harmonised standards used

EN 60335-1

EN 60335-2-41

EN 62233: 2008

EN 55014-1: 2017 + A11: 2020

EN 55014-2: 2015

EN 61000-3-2: 2014

EN 61000-3-3: 2013

EN IEC 63000: 2018

The signatories act on behalf of and with the authority of the company management.

Kärcher SP 16.000 Flood Box - Harmonised standards used - 1
H. Jenner

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Harmonised standards used - 2
S. Reiser

Manager Regulatory Affairs & Certification

Documentation supervisor:

S. Reiser

Alfred Kärcher SE & Co. KG

Alfred-Kärcher-Str. 28 - 40

71364 Winnenden (Germany)

Ph.: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 2021/06/01

Declaration of Conformity (UK)

We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.

Product: Pump

Type: 1.645-xxx

Currently applicable UK Regulations

S.I. 2016/1101 (as amended)

S.I. 2016/1091 (as amended)

S.I. 2012/3032 (as amended)

S.I. 2010/2617 (as amended)

Commission Regulation(s)

(EU) 2019/1781

Designated standards used

EN 60335-1

EN 60335-2-41

EN 62233: 2008

EN 55014-1: 2017 + A11: 2020

EN 55014-2: 2015

EN 61000-3-2: 2014

EN 61000-3-3: 2013

EN IEC 63000: 2018

The signatories act on behalf of and with the authority of the company management.

Kärcher SP 16.000 Flood Box - Designated standards used - 1
H. Jenner

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Designated standards used - 2
S. Reiser

Manager Regulatory Affairs & Certification

Documentation supervisor:

S. Reiser

Alfred Kärcher SE & Co. KG

Alfred-Kärcher-Str. 28 - 40

71364 Winnenden (Germany)

Ph.: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 2021/06/01

Contenu

71364 Winnenden (Germany)

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Contenu - 1
S. Reiser

Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tel.: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 01/06/2021

Inhoud

Kärcher SP 16.000 Flood Box - Inhoud - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Inhoud - 2
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tel.: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 2021/06/01

Kärcher SP 16.000 Flood Box - Inhoud - 3
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Inhoud - 4
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tel.: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 01/06/2021

Índice

Kärcher SP 16.000 Flood Box - Inhoud - 5
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Inhoud - 6
S. Reiser
Manager Regulatory Affairs & Certification

Kärcher SP 16.000 Flood Box - Inhoud - 7
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Inhoud - 8
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tlf.: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 2021/06/01

Indhold

Generelle merknader.... 42

Optimere transportmengden 45

EU-samsvarserklæring.... 45

Generelle merknader

Kärcher SP 16.000 Flood Box - Generelle merknader - 1

Kärcher SP 16.000 Flood Box - Generelle merknader - 2

4 Skyv tilkoblingsstussen inn i Quick-Connect.

Figur C

Koble slangen til pumpen när du bruker en 3/4"eller 1" slange (SP 16.000 Dirt):

5 Skyv tilkoblingsstussen inn i Quick-Connect.

Figur C

Sett opp / senk pumpen:

Optimere transportmengden

Kärcher SP 16.000 Flood Box - Optimere transportmengden - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Optimere transportmengden - 2
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tlf.: +49 7195 14-0

Winnenden, 2021/06/01

Innehåll

Allmän information.... 46

Kärcher SP 16.000 Flood Box - Innehåll - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Innehåll - 2
S. Reiser
Manager Regulatory Affairs & Certification

D-71364 Winnenden (Germany)

Tfn: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 01.06.2021

Sisältö

Yleisiä ohjeita 50

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Sisältö - 1

S. Reiser

Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Puh.: +49 7195 14-0

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Sisältö - 2
S. Reiser

Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tηλ.: +49 7195 14-0

Φαξ: +49 7195 14-2212

Winnenden, 2021/06/01

İçindekiler

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - İçindekiler - 1
S. Reiser

Manager Regulatory Affairs & Certification

Winnenden, 2021/06/01

Содержание

Общие указания 64

Kärcher SP 16.000 Flood Box - Содержание - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Содержание - 2
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Тел.: +49 7195 14-0

Факс: +49 7195 14-2212

Kärcher SP 16.000 Flood Box - Содержание - 3
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Содержание - 4
S. Reiser
Manager Regulatory Affairs & Certification

Winnenden, 2021/06/01

Obsah

Obecné pokyny 74

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Obsah - 1
S. Reiser

Manager Regulatory Affairs & Certification

Winnenden, 2021/06/01

Kazalo

Kärcher SP 16.000 Flood Box - Kazalo - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Kazalo - 2
S. Reiser
Manager Regulatory Affairs & Certification

Winnenden, 1. 6. 2021

Spis treści

Wskazówki ogólne 83

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Spis treści - 1

S. Reiser

Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tel.: +49 7195 14-0

Directive UE relevante

2014/35/UE

2014/30/UE

2011/65/UE

2009/125/UE

Regulament(e) utilizat(e)

(UE) 2019/1781

Norme armonizate aplicate

EN 60335-1

EN 60335-2-41

EN 62233: 2008

EN 55014-1: 2017 + A11: 2020

EN 55014-2: 2015

EN 61000-3-2: 2014

EN 61000-3-3: 2013

EN IEC 63000: 2018

Kärcher SP 16.000 Flood Box - Norme armonizate aplicate - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Norme armonizate aplicate - 2
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germania)

Tel.: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 2021/06/01

Obsah

Všeobecné upozornenia.... 93

Kärcher SP 16.000 Flood Box - Obsah - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Obsah - 2
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tel.: +49 7195 14-0

Fax: +49 7195 14-2212

Winnenden, 01.06.2021

Sadržaj

Opće napomene98
Namjenska uporaba98
Sigurnosne razine98
Zaštita okoliša98
Pribor i zamjenski dijelovi98
Sadržaj isporuke99
Jamstvo99
Opis uređaja99
Puštanje u pogon99
Rad99
Njega i održavanje100
Transport100
Skladištenje101
Otklanjanje smetnji101
Tehnički podaci101
Optimizacija količine dobave102
EU izjava o sukladnosti102

Opće napomene

Prije prve uporabe Vašeg uređaja pročitajte ove originalne upute za rad i priložene Sigurnosne naputke. Postupajte u skladu s njima.Čuvajte obje knjižice za kasniju uporabu ili za sljedećeg vlasnika.

Namjenska uporaba

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Obsah - 3
S. Reiser

Manager Regulatory Affairs & Certification

Opunomoćenik za dokumentaciju:

S. Reiser

Alfred Kärcher SE & Co. KG

Alfred-Kärcher-Str. 28 - 40

71364 Winnenden (Njemačka)

Tel.: +49 7195 14-0

Telefaks: +49 7195 14-2212

Winnenden, 01.06.2021.

Sadržaj

Opšte napomene.... 102

Namenska upotreba.... 102

Stepeni opasnosti.... 103

Kärcher SP 16.000 Flood Box - Sadržaj - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Sadržaj - 2
S. Reiser
Manager Regulatory Affairs & Certification

Lice ovlašćeno za dokumentaciju:

S. Reiser

Alfred Kärcher SE & Co. KG

Alfred-Kärcher-Str. 28 - 40

71364 Winnenden (Germany)

Tel.: +49 7195 14-0

Winnenden, 2021/06/01

Съдържание

Общи указания.... 107

Употреба по предназначение.... 107

Степени на опасност 107

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Съдържание - 1
S. Reiser

Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Тел.: +49 7195 14-0

Факс: +49 7195 14-2212

Виненден, 2021/06/01

Sisukord

Kärcher SP 16.000 Flood Box - Sisukord - 1
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Sisukord - 2
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Tel: +49 7195 14-0

Winnenden, 2021/06/01

Saturs

www.kaercher.com/REACH

Piederumi un rezerves dalas

Izmantot tikai oriğinâlos piederumus un oriğinâlâs rezerves daļas, jo tie garantē drošu un nevainojamu ierīces darbību.

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Piederumi un rezerves dalas - 1
S. Reiser

Manager Regulatory Affairs & Certification

Kärcher SP 16.000 Flood Box - Piederumi un rezerves dalas - 2
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Piederumi un rezerves dalas - 3
S. Reiser
Manager Regulatory Affairs & Certification

Kärcher SP 16.000 Flood Box - Piederumi un rezerves dalas - 4
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Piederumi un rezerves dalas - 5
S. Reiser
Manager Regulatory Affairs & Certification

71364 Winnenden (Germany)

Тел.: +49 7195 14-0

Факс: +49 7195 14-2212

Kärcher SP 16.000 Flood Box - Piederumi un rezerves dalas - 6
H. Jenner
Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Piederumi un rezerves dalas - 7
S. Reiser
Manager Regulatory Affairs & Certification

Chairman of the Board of Management

Kärcher SP 16.000 Flood Box - Piederumi un rezerves dalas - 8

S. Reiser

Manager Regulatory Affairs & Certification

文書の全権委員:

S. Reiser

Alfred Kärcher SE & Co. KG

Alfred-Kärcher-Str. 28 - 40

71364 Winnenden (Germany)

電話番号:+49 7195 14-0

Winnenden, 2021/06/01

www.kaercher.com/REACH

natural_image Black and white icon of a hand giving a thumbs-up gesture (no text or symbols)

THANK YOU!

MERCI! DANKE! iGRACIAS!

Kärcher SP 16.000 Flood Box - MERCI! DANKE! iGRACIAS! - 1

Register your product and benefit from many advantages.

www.kaercher.com/welcome

Kärcher SP 16.000 Flood Box - MERCI! DANKE! iGRACIAS! - 2

Kärcher SP 16.000 Flood Box - MERCI! DANKE! iGRACIAS! - 3

Rate your product and tell us your opinion.

natural_image Icon showing a gear and wrench inside a square frame (no text or symbols)

www.kaercher.com/dealersearch

Alfred Kärcher SE & Co. KG

Alfred-Kärcher-Str. 28-40

71364 Winnenden (Germany)

Tel.: +49 7195 14-0

Fax: +49 7195 14-2212

QR code image with a central logo, likely linking to a digital resource or website.

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Kärcher

Model : SP 16.000 Flood Box

Category : Pump