GARDENA 10500 - Pump

10500 - Pump GARDENA - Free user manual and instructions

Find the device manual for free 10500 GARDENA in PDF.

📄 182 pages English EN 💬 AI Question
Notice GARDENA 10500 - page 11

Questions des utilisateurs sur 10500 GARDENA

0 question sur cet appareil. Repondez a celles que vous connaissez ou posez la votre.

Poser une nouvelle question sur cet appareil

L'email reste privé : il sert seulement à vous prévenir si quelqu'un répond à votre question.

Aucune question pour l'instant. Soyez le premier à en poser une.

Download the instructions for your Pump in PDF format for free! Find your manual 10500 - GARDENA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 10500 by GARDENA.

USER MANUAL 10500 GARDENA

Original instructions. This product may be used under supervision, or if instruction regarding the safe use of the product has been provided and the resulting dangers have been understood, by children aged 8and above, as well as by persons with physical, sensory or mental disabilities or a lack of experience and knowledge. Chil- dren must not be allowed to play with the product. Cleaning and user maintenance must not be performed by children with- out supervision. The use of this product by young people under the age of 16 is not recommended. Never operate the product when you are tired, ill or under the influ- ence of alcohol, drugs or medicine. Intended use: The GARDENA Submersible Pump is intended for drain- age purposes if flooding occurs but also for transferring water to and from tanks and pumping them out, for draw- ing water from wells and shafts, for draining boats and yachts and for aerating and circulating water for limited peri- ods and for pumping chlorinated water in private domestic gardens and allotments. Liquids to be pumped: The GARDENA Submersible Pump must only be used to pump water. The pump is fully submersible (water-tight encapsulation) and is submerged in water (for max. submersion depth, see 7. TECHNICAL DATA). The product is suitable for pumping the following liquids:

  • Clear Water Submersible Pump: clean to slightly dirty water with amax. particle size of 5 mm.
  • Dirty Water Submersible Pump: dirty water with a max. particle size of 25 mm. The product is not intended for long term use (continuous circulation operation). DANGER! Risk of injury! v The pump should not be used for the delivery of salt water, corrosive, easily inflammable or explosive liquids (e. g. petrol, paraffin, thinners), oil, heating oil or foodstuffs.

IMPORTANT! Read the operator’s manual carefully before use and keep for future reference. Symbols on the product: Read operator’s manual. General safety warnings Electrical safety DANGER! Electric shock! Risk of injury due to electric current. v The product must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA. DANGER! Risk of physical injury! Risk of injury due to electric current. v Disconnect the product from the mains before you maintain or replace parts. Thereby the dis- connected socket must be in the visual range. Safe operating practices The water temperature should not exceed 35 °C. The pump must not be used when people are in the water. Pollution of the liquid could occur due to leakage of lubricants. Keep bystanders away from the water. Operate the pump only with the elbow connector. GARDENA Clear Water Submersible Pump / Dirty Water Submersible Pump

9000-20.960.01.indb 11 07.12.20 10:21Circuit breaker Thermal protection switch: In the event of an overload, the pump is switched off by the built-in thermal motor protection. After sufficient cool- ing of the motor, the pump is operational again. Automatic venting This pump is equipped with a vent valve which eliminates any air pockets in the pump. Depending on the function, a small amount of water can escape from the side of the housing. Additional safety warnings Electrical safety DANGER! Cardiac arrest! This product makes an electromagnetic field while it operates. This field may under some conditions interfere with active or passive medical implants. To decrease the risk of conditions that can possibly injure or kill, we recommend persons with medical implants to speak with their physician and the medi- cal implant manufacturer before you operate the product. Cables If extension cables are used, these must comply with the minimum cross- sections in the table below: Voltage Cable length Cross section 230 – 240 V / 50 Hz Up to 20 m 1.5 mm

DANGER! Electric shock! With a cut off mains plug, moisture can get into electrical parts via the mains cable and cause ashort circuit. v Never cut the mains plug off (e. g. to feed through wall). v Don’t use the power cable for plugging off. v If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Mains plug and extension connections must be protected from water splashes. Ensure that the electrical connections for plugs and sock- ets are made in areas safe from flooding. Protect the mains plug and the mains power cable from heat, oil and sharp edges. Observe the mains voltage. The information on the name- plate must be in agreement with the data for the mains power grid. The pump’s mains plug must be disconnected before anybody enters the swimming pool or touches the surface of the water. The mains power cable must not be used for fastening or transporting the pump. For submerging or lifting / securing the pump, please use a fastening rope. Please regularly check the connecting line. Before using, always subject the pump (especially the power cables and the power connections) to a visual inspection. A pump which is damaged should not be used. In the event of damage, have the pump checked by GARDENA Service. Assembly instructions: Retighten all screws by hand. Before use after maintenance, make sure that all parts are screwed together. When using our pumps with a generator, the warnings of the generator manufacturer must be observed. Personal safety DANGER! Risk of suffocation! Small parts can be easily swallowed. There is also arisk that the polybagcan suffocate toddlers. Keep toddlers away when you assemble the product. Observe the minimum water level in accordance with the characteristics given for the pump. Allow the pump to run no longer than 10 minutes against a closed pressure side. Sand and other abrasive substances cause increased wear and reduce the pump’s output. The float switch may only be operated outside the water. The hose must not be disconnected during operation. Allow the pump to cool down before troubleshooting. The pump must not be operated without the mounted contra-angle handpiece.

DANGER! Risk of injury! Injury when the product starts accidentally. v Disconnect the product from the mains before you assemble the product. To screw the elbow connector into the pump [ Fig. A1 ]: DANGER! Risk of injury! Cut Injury by the impeller. v Operate the pump only with the elbow connector.

clockwise into the pump. The hose can be connected via the pump connection

[25 mm (1") and 38 mm (11/2")] or via the GARDENA Connection System [13 mm (1/2") / 16 mm (5/8") / 19 mm (3/4")]. When using a 38 mm (1 1/2") hose, the pump has the maximum delivery capacity. Connect hose via connection nipple [ Fig. A2 / A3 / A4 ]: 25 mm (1")- and 38 mm (1 1/2")-hoses can be connected via the connection nipple

[ Fig. A4 ]. 25 mm (1")- and 38 mm (1 1/2") hoses connected with aconnection nipple

must be fastened, for example with a GARDENA Hose Clamp Art. 7193 / 7195.

1. Screw the elbow connector into the pump.

. (For 38 mm (1 1/2") hoses, first detach the connection nipple

3. Push the hose onto the connection nipple

and fix e. g. with a GARDENA Hose Clamp Art. 7193 / 7195. Connect hose via the GARDENA Connection System [ Fig. A5 ]: We do not recommend to use hoses with a diameter smaller than 19 mm (3/4"), as otherwise the flow rate will be reduced. Hose diameter Pump connection 19 mm (3/4") GARDENA Pump Connection Set Art. 1752 v Connect the hose via the relevant GARDENA Connec- tion System.

DANGER! Risk of injury! Injury when the product starts accidentally. v Disconnect the product from the mains before you connect, adjust or transport the product. To pump water: If the pump cannot be immersed into the water reservoir via the handle, the pump must always be immersed into the well or water reservoir via a rope. Minimum immersion depth during initial operation see 7. TECHNICAL DATA. Take care that the pump is located where the inlet openings at the suction base are not obstructed neither completely nor partly. Stand the pump on a brick if using in a pond.

1. Submerge the pump in water reservoir.

2. Connect the pump to the mains.

Attention! The pump begins operating immediately. Automatic mode with float switch [ Fig. O1 ]: So that the pump automatically switches off when there is no liquid to pump, the Float Switch

must be able to freely move on the surface of the water. To adjust the Cut-in and Cut-out Height [ Fig. O1 ]: The maximum cut-in height and minimum cut-out height (see 7. TECHNICAL DATA) can be adjusted by pushing the float switch wire into the float switch lock.

  • The shorter the length of cable between the float switch

and the float switch lock

, the lower the cut-in height and the higher the cut-out height. v Push the cable of the float switch

into the opening in the float switch lock

CAUTION! In order to ensure that the float switch is able to switch on and off, the cable length between the float switch and the float switch lock must be at least 10 cm. Manual operation [ Fig. O2 ]: The pump remains permanently in operation because the float switch is bypassed.

with the cable downwards onto the float switch locking device

2. Stand the pump on a firm surface.

3. Connect the pump to the mains.

Attention! The pump begins operating immediately. The minimum residual water depth (see 7. TECHNICAL DATA) is only achieved in manual mode because the float switch already switches off the pump before this when in automatic mode.

DANGER! Risk of injury! Injury when the product starts accidentally. v Disconnect the product from the mains before you maintain the product. To flush the pump: After pumping chlorinated water, the pump must be flushed.

1. Pump lukewarm water (max. 35 °C), possibly adding

amild cleaning agent (e. g. detergent) until the pumped water runs clear.

2. Remove residuals according to the waste disposal laws

applicable in your area.

To put into storage: The pump is not frost-proof! The product must be stored away from children.

1. Disconnect the pump from the mains.

2. Turn the pump upside down until no more water runs

4. Store the pump in a dry, enclosed and frost-free place.

Disposal: (in accordance with RL2012/19/EC) The product must not be disposed of to normal household waste. It must be disposed of in line with local environmental regulations. IMPORTANT! v Dispose of the product through or via your municipal recycling collection centre.

DANGER! Risk of injury! Injury when the product starts accidentally. v Disconnect the product from the mains before you troubleshoot the product. To clean the suction base and the impeller [ Fig. T1 ]:

1. Unscrew the 4 Phillips screws

2. Pull the suction base

3. Clean suction base

(the warranty does not become void as a result of this maintenance work).

4. Reinstall the suction base

5. Screw in the 4 Phillips screws

again. For safety reasons a damaged impeller can only be exchanged by the GARDENA Service Centre. Problem Possible Cause Remedy Pump is running, but doesn’t deliver water Air cannot escape, because the pressure line is closed. (Pos siblekink in the pressure hose.) v Open the pressure line (e. g. shut-off valve, delivery units). Air in suction foot. v Wait for about 60 seconds until the pump has vented; if necessary, turn off and then on again. Suction opening is clogged. v Clean the suction opening with awater jet. Hose is clogged. v Remove the clog from the hose. Impeller is blocked. v Clean the impeller. Water level below minimum water level when put into operation. v Submerge the pump deeper. Pump does not start, or stops suddenly during operation Thermal switch has turned the pump off because of overheating. v Clean the suction opening. Observe the max. media temperature (35 °C). No power supply to the pump. v Check fuses and electrical plug connections. RCD has triggered (residual current). v Disconnect the pump and contact the GARDENA Service.

9000-20.960.01.indb 14 07.12.20 10:21Problem Possible Cause Remedy Pump is running but the delivery drops suddenly Suction opening is clogged. v Clean the suction opening with awater jet. Hose is clogged. v Remove the clog from the hose. NOTE: For any other malfunctions please contact the GARDENA service department. Repairs must only be done by GARDENA service departments or specialist dealers approved by GARDENA.

9000-20.960.01.indb 15 07.12.20 10:219. SERVICE / WARRANTY Service: Please contact the address on the back page. Warranty statement: In the event of a warranty claim, no charge is levied to you for the services provided. GARDENA Manufacturing GmbH grants a warranty for all original GARDENA new products for two years from the date of original purchase from the retailer, provided that the devices have been for private use only. This manu- facturer’s warranty does not apply to products acquired second hand. This warranty includes all significant defects of the product that can be proved to be material or manu- facturing faults. This war ranty is fulfilled by supplying afully functional replacement product or by repairing the faulty product sent to us free of charge; we reserve the right to choose between these options. This service is subject to the following provisions:

  • The product has been used for its intended purpose as per the recommendations in the operating instructions.
  • Neither the purchaser nor a third party has attempted to open or repair the product.
  • Only Original GARDENA replacement parts and wear parts have been used for operation.
  • Presentation of the receipt. Normal wear and tear of parts and components (such as blades, blade fixing parts, turbines, light bulbs, V-belts / toothed belts, impellers, air filters, spark plugs), visual changes, wear parts and consumables are excluded from the warranty. This manufacturer’s warranty is limited to replacement and repair of products in accordance with the abovemen- tioned conditions. The manufacturer’s warranty does not constitute an entitlement to lodge other claims against us as amanufacturer, such as for damages. This manufac- turer’s warranty does not, of course, affect statutory and contractual warranty claims against the dealer / retailer. The manufacturer’s warranty is governed by the law of the Federal Republic of Germany. In case of a warranty claim, please return the faulty product, together with a copy of the receipt and a description of the fault, with postage paid to the service address. Consumables: The impeller is a consumable and is not included in the warranty.

3. Rengjør pumpen (se 4. VEDLIKEHOLD).

Manual assistant
Powered by ChatGPT
Waiting for your message
Product information

Brand : GARDENA

Model : 10500

Category : Pump