HD 9184 Cage Classic - Pressure washer Kärcher - Free user manual and instructions
Find the device manual for free HD 9184 Cage Classic Kärcher in PDF.
Download the instructions for your Pressure washer in PDF format for free! Find your manual HD 9184 Cage Classic - Kärcher and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HD 9184 Cage Classic by Kärcher.
USER MANUAL HD 9184 Cage Classic Kärcher
- Equipment depends on the unit model – Please read the operating instructions for your machine before using it, and pay particular attention to the following safety instructions. – Warning and information plates on the machine provide important directions for safe operation. – Apart from the notes contained herein the general safety provisions and rules for the prevention of accidents of the legislator must be observed. DANGER Pointer to immediate danger, which leads to severe injuries or death. 몇 WARNING Pointer to a possibly dangerous situation, which can lead to severe injuries or death. 몇 CAUTION Pointer to a possibly dangerous situation, which can lead to minor injuries. ATTENTION Pointer to a possibly dangerous situation, which can lead to property damage. High-pressure jets can be dan- gerous if improperly used. The jet may not be directed at per- sons, animals, active electrical equipment or at the appliance itself. According to applicable regula- tions, the appliance must never be used on the drinking water net without a system separator. A suitable system separator by Kärcher or al- ternatively a system separator according to EN 12729 type BA must be used. Water that was flowing through a system separator is considered non-drinkable. The appliance contains hot sur- faces that can lead to burn inju- ries. Risk of electric shock. The casing must only be opened by electri- cians. Contents Device elements . . . . . . . . . . . EN 1 Safety instructions. . . . . . . . . . EN 1 Proper use . . . . . . . . . . . . . . . EN 4 Safety Devices . . . . . . . . . . . . EN 4 Environmental protection . . . . EN 5 Before Startup. . . . . . . . . . . . . EN 5 Start up . . . . . . . . . . . . . . . . . . EN 6 Operation . . . . . . . . . . . . . . . . EN 6 Transport. . . . . . . . . . . . . . . . . EN 8 Storage . . . . . . . . . . . . . . . . . . EN 8 Care and maintenance . . . . . . EN 8 Troubleshooting . . . . . . . . . . . EN 9 Spare parts . . . . . . . . . . . . . . . EN 9 Warranty . . . . . . . . . . . . . . . . . EN 9 EU Declaration of Conformity . EN 10 Declaration of Conformity . . . . EN 11 Technical specifications . . . . . EN 12 Device elements Safety instructions Symbols in the operating instructions Symbols on the machine 16 EN– 2 – The voltage indicated on the type plate must correspond to the voltage of the electrical source. – Minimum fuse strength of the socket (see Technical Data). – Safety class I - Appliances may only be connected to sockets with proper earthing. – It is recommended that you connect this device to a socket that has a 30 mA pro- tection switch against wrong currents. – Please use the mains cable prescribed by the manufacturer; the same is also applicable when you replace the ca- bles. See Operating Instructions Manu- al for Order Number and Type. – Check the power cord with mains plug for damage before every use. If the power cord is damaged, please arrange immediately for the exchange by an au- thorized customer service or a skilled electrician. – The appliance may only be connected to an electrical supply which has been installed by an electrician in accordance with IEC 60364. – Operating procedures create short term power sinkings. – During unfavorable net conditions other devices might be disturbed. – Never touch the mains plug with wet hands. – Make sure that the power cord or exten- sion cables are not damaged by run- ning over, pinching, dragging or similar. Protect the cable from heat, oil, and sharp edges. – The extension cable must have the cross- section listed in the circuit plan and be pro- tected against spraying water. The con- nection must not lie in water. – The mains plug and the coupling of an extension cable must be watertight and must never lie in water. Moreover, the coupling may never lie on the ground. The use of cable reels that ensure that the sockets are at least 60 mm above the ground is recommended. – Unsuitable electrical extension cables can be hazardous. Only use electrical extension cables outdoors which have been approved and labelled for this pur- pose and have an adequate cable cross-section. – The power cord must be checked regu- larly for damages, such as cracks or ag- ing. If damage is found, the cable must be replaced before further use. – If couplings of the power cord or exten- sion cable are replace the splash pro- tection and the mechanical tightness must be ensured. – Do not clean the appliance with a water hose or high-pressure water jet (danger of short circuits or other damage). – Do not operate the appliance at temper- atures below 0 °C. – Please observe the safety instructions of your water supply authority. – Please ensure that screw connections of all hoses are not leaky. – The high pressure hose must not be damaged. A damaged high pressure hose must be replaced immediately. Only hoses and joints recommended by the manufacturer may be used. See Operating Instructions Manual for Order Number. – The appliance and its working equip- ment must be checked to ensure that it is in proper working order and is operat- ing safely prior to use. The appliance must not be used if a con- necting line or important parts of the appli- ance, e.g. safety devices, high-pressure hoses, spray guns, are damaged.
Never draw in fluids containing solvents or undiluted acids and solvents! This in- cludes petrol, paint thinner and heating oil. The spray mist thus generated is highly inflammable, explosive and poi- sonous. Do not use acetone, undiluted acids and solvents as they are aggres- sive towards the materials from which the appliance is made. Power connection Water connection Application 17EN– 3 – If the appliance is used in hazardous ar- eas (e.g. filling stations) the corre- sponding safety provisions must be ob- served. It is not allowed to use the appli- ance in hazardous locations. – The appliance must be sitting on an even, stable ground. – Wear ear plugs if the operating instruc- tions of the appliance (Technical data) mention a noise level of more than 80 dB(A). – All current-conducting parts in the work- ing area must be protected against jet water. – The lever of the hand spray gun must not be locked during the operation. – Wear protective clothing and safety goggles to protect against splash back containing water or dirt. – High-pressure jets can be dangerous if improperly used. The jet may not be di- rected at persons, animals, live electri- cal equipment or at the appliance itself. – The jet must not be directed at other persons or directed by the user at him/ herself to clean clothing or footwear. – Vehicle tyres/ tyre valves may be cleaned only with a minimum spray dis- tance of 30 cm. Otherwise, the high pressure spray can cause damage to the vehicle tyre/ tyre valve. The discol- ouring of the tyre is the first sign of dam- age. Damaged vehicle tyres are a source of danger. – Do not spray materials containing as- bestos or other health-hazardous sub- stances. – With short spray lances, there is a risk of injury, as a hand can accidentally come in contact with the high pressure jet. If the spray lance is shorter than 75 cm, you must not use a point spray noz- zle or a rotor nozzle. – Prior to cleaning, a risk assessment must be performed for the surface to be cleaned to determine the safety and health requirements. The respective re- quired protective measures must be taken. – Let the hoses cool off after hot water op- eration or operate the appliance briefly using cold water. – In case of extended downtimes, switch the appliance off at the main switch / ap- pliance switch or remove the mains plug. – The operator must use the appliance properly. The person must consider the local conditions and must pay attention to third parties, in particular children, when working with the appliance. – Never leave the machine unattended so long as it is running. – The appliance may only used by per- sons who have been instructed in han- dling the appliance or have proven qualification and expertise in operating the appliance or have been explicitly assigned the task of handling the appli- ance. The appliance must not be oper- ated by children, young persons or per- sons who have not been instructed ac- cordingly. – This appliance is not intended for use by persons with reduced physical, sen- sory or mental capabilities. – The appliance must not be operated by children or persons who have not been instructed accordingly. – Do not use the appliance when there are other persons around unless they are also wearing safety gear. – Children should be supervised to pre- vent them from playing with the appli- ance. – Always use appropriate gloves while working on the device. – There is a recoil pressure arising from the water jet that comes out from the spray pipe. The angular spray pipe brings about an upward force. Hold the gun and the spray pipe tightly. – The recoil and bending forces may be different if you are using angular spray devices. Operations 18 EN– 4 The engine is to be brought to a standstill and the appliance is to be fastened properly during transportation. – Switch off the appliance and, in case of appliances connected to the mains, pull out the power cord before cleaning and performing any maintenance tasks on the machine. – Relieve the high pressure system of all pressure prior to all work on the appli- ance and the accessories. – Maintenance work may only be carried out by approved customer service outlets or ex- perts in this field who are familiar with the re- spective safety regulations. – Mobile industrial apliances are subject to safety inspections according to the local regulations (for e.g. the following are applicable in Germany: VDE 0701). – To avoid risks, all repairs and replace- ment of spare parts may only be carried out by the authorised customer service personnel. – Only use accessories and spare parts which have been approved by the man- ufacturer. The exclusive use of original accessories and original spare parts ensures that the appliance can be oper- ated safely and trouble free. Use this high pressure cleaner exclusively for – cleaning with a high pressure jet without detergent (e.g. cleaning of facades, ter- races, garden appliances, vehicles and similar objects). For stubborn dirt, we recommend the use of the dirt blaster as a special accessory. Quality requirements for water: ATTENTION Only clean water may be used as high pressure medium. Impurities will lead to in- creased wear and tear or formation of de- posits in the appliance. If recycled water is used, the following limit values must not be exceeded. Safety devices serve to protect the user and must not be rendered in operational or their functions bypassed. The trigger safety on the trigger gun pre- vents accidental switch-on of the appli- ance. – While reducing the water supply/quanti- ty regulation at the pump head, the overflow valve opens and part of the water flows back to the pump suck side. – If the hand spray gun is closed, the overflow valve opens and the entire wa- ter volume will flow back to the pump suction side. The overflow valve is set by the manufac- turer and sealed. Setting only by customer service. Transport Maintenance Accessories and Spare Parts Proper use pH value 6,5...9,5 electrical conductivity * Conductivity fresh water +1200 µS/cm settleable solids ** < 0,5 mg/l total suspended solids *** < 50 mg/l Hydrocarbons < 20 mg/l Chloride < 300 mg/l Sulphate < 240 mg/l Calcium < 200 mg/l Total hardness < 28 °dH < 50 °TH < 500 ppm (mg CaCO
- Maximum total 2000 µS/cm ** Test volume 1 l, settling time 30 min *** no abrasive substances Safety Devices Trigger safety Overflow valve 19EN– 5 The safety valve opens when the overflow valve is defective. The safety valve is set by the manufacturer and sealed. Setting only by customer service. Not all unit models are equipped with a safety valve. The thermal valve protects the high-pres- sure pump from unacceptable heating dur- ing circuit operation. Not all unit models are equipped with a thermostat valve. If the lever on the trigger gun is released the pressure switch turns off the pump, the high pressure jet is stopped. If the lever is pulled the pump is turned on again. Not all unit models are equipped with a pressure switch. The packaging material can be recy- cled. Please do not place the packag- ing into the ordinary refuse for dispos- al, but arrange for the proper recy- cling. Old appliances contain valuable ma- terials that can be recycled. Please arrange for the proper recycling of old appliances. Batteries and accumula- tors contain substances that must not enter the environment. Please dis- pose of your old appliances, batteries and accumulators using appropriate collection systems. Notes about the ingredients (REACH) You will find current information about the ingredients at: www.kaercher.com/REACH – Check the contents of the pack before unpacking. – In case of transport damage inform ven- dor immediately. The oil level must be at the centre of the oil level display. Unscrew the screw plug. Screw in enclosed oil filling screw. Close cover. Connect spray lance to trigger gun. Install nozzle with nozzle screw at the spray lance. Screw the high-pressure hose on to the hand spray gun. Fasten the high pressure hose to the high pressure connection. If required, attach accompanying cable / hose rack to the wall.
- Illustration Attach the enclosed cable/hose rack to the bottom of the device. Note: Not all unit models are equipped with the holder for the trigger gun. Illustration Attaching the support. Safety valve Thermostat valve Pressure switch Environmental protection Before Startup Unpacking Check oil level Activate deaeration of oil container Attaching the Accessories Mounting the cable / hose rack Attaching the holder for the trigger gun 20 EN– 6 DANGER Danger of injury by electric shock. The appliance may only be connected to al- ternating current. It is imperative to connect the appliance to the electric mains by means of a plug. It is forbidden to permanently connect the appli- ance to the power supply. The plug serves for the disconnection from the mains. Use the extension cord that has an ade- quate cross-section (see "Technical Data") and unwind it fully from the cable drum. For connection values, see type plate/tech- nical data. 몇 WARNING The highest allowed net impedance at the electrical connection point (refer to techni- cal data) is not to be exceeded. In case of confusion regarding the power impedance present on your connection, please contact your utilities provider. According to applicable regula- tions, the appliance must never be used on the drinking water net without a system separator. En- sure that the connection of your building water installation on which the high-pres- sure cleaner is operated is equipped with a system separator pursuant to EN 12729 Type BA. Water that was flowing through a system separator is considered non-drinkable. 몇 CAUTION Always connect the system separator to the water supply, never directly to the appli- ance! For connection values refer to technical specifications. Connect the supply hose (minimum length 7.5 m, minimum diameter 3/4“) to the water connection point of the ma- chine and at the water supply point (for e.g. a tap). Note: The supply hose is not included. Open the water supply. Screw the suction hose onto the water connection. Note: The suction hose is not included in the scope of delivery. If a suction hose with a check valve or filter is used, the hose must be filled with water. Deaerate the appliance: Unscrew the nozzle. Switch on the appliance and let it run until the water exiting is bubble-free. At the end let the appliance run for approx. 10 seconds - then switch off. Repeat the procedure for a couple of times. Switch off the appliance and fit the noz- zle again. DANGER Risk of explosion! Do not spray flammable liquids. If the appliance is used in hazardous areas (e.g. filling stations) the corresponding safety regulations must be observed. ATTENTION Clean engines only at places with corre- sponding oil separators (environmental safety). DANGER Long hours of using the appliance can cause circulation problems in the hands on account of vibrations. It is not possible to specify a generally valid operation time, since this depends on sev- eral factors: – Proneness to blood circulation deficien- cies (cold, numb fingers). – Low ambient temperature. Wear warm gloves to protect hands. – A firm grip impedes blood circulation. Start up Electrical connection HD 7/11-4 Cage: Water connection Connection to the water supply Drawing in water from open reservoirs Operation 21EN– 7 – Continuous operation is worse than an operation interrupted by pauses. In case of regular, long-term operation of the device and in case of repeated occur- rence of the symptoms (e.g. cold, numb fin- gers) please consult a physician. Unlock the trigger safety and pull the le- ver of the trigger gun. Set working pressure and flow rate through turning (runless) at the pres- sure- and amount regulation (B) (+/-). Release the lever on the trigger gun. Appliance with pressure switch (B) switches off. Appliances without pressure switch go into circuit operation. Release the lever of the trigger gun again. Appliance with pressure switch starts. Appliances without pressure switch end circuit operation. Release the lever on the trigger gun. Operate the trigger safety of the trigger gun to secure the lever of the gun against accidental triggering. Unlock the trigger safety and pull the le- ver of the trigger gun. Set the appliance switch to "0". Disconnect the mains plug from the socket. Shut off water supply. Activate trigger gun until device is pres- sure-less. Operate the trigger safety of the trigger gun to secure the lever of the gun against accidental triggering. High pressure operation Appliance with hold- er for trig- ger gun (A) Set the appliance switch to "I". Remove the hand spray gun from the holder,the appliance switches on. Appliance with pres- sure switch (B) Set the appliance switch to "I". The appliance is ready for operation and starts when the lever of the trigger gun is pulled. Appliance without (A) and (B) Set the appliance switch to "I". The appliance switches on. Interrupting operation Short break Longer break Appliance with hold- er for trig- ger gun (A) Place the trigger gun into the holder. The pump stops. Remove trigger gun from the holder. The pump starts. Appliance with pres- sure switch (B) Set the appliance switch to "0/OFF“. The pump is switched off. Set the appliance switch to "I". The pump is ready for op- eration. Appliance without (A) and (B) Set the appliance switch to "0/OFF“. The pump is switched off. Set the appliance switch to "I". The pump starts. Turn off the appliance 22 EN– 8 ATTENTION Frost will destroy the not completely water drained device. Store the appliance in a frost free area. Drain water. Pump in conventional frost protection agents through the appliance. Note: Use normal glycol-based anti-freezing agents for automobiles. Observe handling instructions of the anti- freeze agent manufacturer. Operate device for max. 1 minute until the pump and conduits are empty. When transporting in vehicles, secure the appliance according to the guide- lines from slipping and tipping over. 몇 CAUTION Risk of personal injury or damage! Mind the weight of the appliance during transport. 몇 CAUTION Risk of personal injury or damage! Consider the weight of the appliance when storing it. DANGER Risk of injury by inadvertent startup of ap- pliance and electrical shock. Prior to all work on the appliance, switch off the appliance and pull the power plug. Note: Used oil must only be disposed of by the designated collection points. Please turn in used oil there. Polluting the environment with used oil is prosecutable. You can sign with your dealer a contract for regular safety inspection or even sign a maintenance contract. Please take advice on this matter. Check connection cable for damages (risk of electrical shock); get the dam- aged connection cable replaced imme- diately by an authorised customer ser- vice person/ electrician. Check the high pressure hose for dam- ages (risk of bursting). Please arrange for the immediate ex- change of a damaged high-pressure hose. Check appliance (pump) for leaks. 3 drops per minute are permitted and can come out from the lower side of the appliance. Call Customer Service if there is heavy leakage. Check oil level Please contact Custom- er Service immediately if the oil is milky (water in oil). Clean water filter. Oil change. Note: See "Specifications" for oil volume and type. Unscrew oil drain plug. Drain the oil in a collection basin. Fix in the oil drain screw and tighten it. Torque 20 p. 25
- Nm. Turn the oil fill screw out. Fill in new oil slowly; air bubbles should go out. The oil level must be at the centre of the oil level display. Screw in oil filling screw. Close cover. Frost protection If you cannot store it in a frost-free place: Transport Storage Care and maintenance Safety inspection/ maintenance contract Before each use Weekly Yearly or after 500 operating hours Oil change 23EN– 9 DANGER Risk of injury by inadvertent startup of ap- pliance and electrical shock. Prior to all work on the appliance, switch off the appliance and pull the power plug. Get the electrical components checked and repaired only by authorised customer ser- vice persons. Contact an authorised customer service person in case of problems not mentioned in this chapter or if you are in doubt or when you have been explicitly asked to do so. Only with appliances with holder for trig- ger gun: Do not push down the holder. Check connection cable for damages. Check the supply voltage. Call Customer Service in case of elec- trical defects. Set the pressure and quantity regula- tion to "MAX". Check the nozzle size, install correct nozzle. Clean the nozzle. Replace the nozzle. Deaerate the appliance (see "Start-up") Check water supply level (refer to tech- nical data). Clean water filter. Check all inlet pipes to the pump. Contact Customer Service if needed. 3 drops per minute are permitted and can come out from the lower side of the appli- ance. Call Customer Service if there is heavy leakage. With stronger leak, have device checked by customer service. Clean water filter. Check the water suction pipes for leaks. Deaerate the appliance (see "Start-up") Contact Customer Service if needed. This function is not a fault. If the appliance becomes too hot in the circulation mode, the thermovalve opens so that cold water can flow in. Turn off the appliance, wait briefly, turn on the appliance once again. If the fault appears again afterwards, do no longer use the appliance. Have the device checked by aftersales service. – Only use accessories and spare parts which have been approved by the man- ufacturer. The exclusive use of original accessories and original spare parts ensures that the appliance can be oper- ated safely and trouble free. – At the end of the operating instructions you will find a selected list of spare parts that are often required. – For additional information about spare parts, please go to the Service section at www.kaercher.com. The warranty terms published by the rele- vant sales company are applicable in each country. We will repair potential failures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or defects in man- ufacturing. In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service center. Please submit the proof of purchase. Troubleshooting Appliance is not running Pressure does not build up in the appliance Pump leaky Pump is vibrating Water leak on the thermovalve Water leak at the safety valve Spare parts Warranty 24 EN– 10 We hereby declare that the machine de- scribed below complies with the relevant basic safety and health requirements of the EU Directives, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the machine is modified without our prior approval. The signatories act on behalf of and with of the authority of the company management. Documentation supervisor: S. Reiser Alfred Kärcher SE & Co. KG Alfred-Kärcher-Straße 28-40 71364 Winnenden (Germany) Tel.: +49 7195 14-0 Fax: +49 7195 14-2212 Winnenden, 2021/04/01 EU Declaration of Conformity Product: High pressure cleaner Type: 1.367-xxx Relevant EU Directives 2000/14/EG 2006/42/EG (+2009/127/EG) 2011/65/EU 2014/30/EU 2009/125/EG Harmonised directive(s) (EU) 2009/1781 Harmonised directive(s) EN 60335–1 EN 60335–2–79 EN IEC 63000: 2018 EN 55014–1: 2017 + A11:2020 EN 55014–2: 2015 EN 61000–3–2: 2014 EN 61000–3–11: 2000 EN 62233: 2008 Applied conformity evaluation method 2000/14/EC: Appendix V Sound power level dB(A) HD 7/11-4 Measured: 87 Guaranteed: 90 HD 7/16-4 Measured: 87 Guaranteed: 90 HD 9/18-4 Measured: 84 Guaranteed: 87 Chairman of the Board of Management Director Regulatory Affairs & Certification 25EN– 11 We hereby declare that the product de- scribed below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval. The signatories act on behalf of and with of the authority of the company management. Documentation supervisor: S. Reiser Alfred Kärcher SE & Co. KG Alfred-Kärcher-Straße 28-40 71364 Winnenden (Germany) Tel.: +49 7195 14-0 Fax: +49 7195 14-2212 Winnenden, 2021/04/01 Declaration of Conformity Product: High pressure cleaner Type: 1.367-xxx Currently applicable UK Regulations S.I. 2001/1701 (as amended) S.I. 2008/1597 (as amended) S.I. 2012/3032 (as amended) S.I. 2016/1091 (as amended) S.I. 2010/2617 (as amended) Comission Regulation(s) EU 2009/1781 Applied designated standards EN 60335–1 EN 60335–2–79 EN IEC 63000: 2018 EN 55014–1: 2017 + A11:2020 EN 55014–2: 2015 EN 61000–3–2: 2014 EN 61000–3–11: 2000 EN 62233: 2008 Applied conformity assessment proce- dure S.I. 2001/1701 (as amended): Schedule 8 Sound power level dB(A) HD 7/11-4 Measured: 87 Guaranteed: 90 HD 7/16-4 Measured: 87 Guaranteed: 90 HD 9/18-4 Measured: 84 Guaranteed: 87 Chairman of the Board of Management Director Regulatory Affairs & Certification 26 EN– 12 Technical specifications Type HD 7/11-4 HD 7/16-4 HD 9/18-4 HD 9/18-4 Main Supply Voltage V 220 p. 240
- 380 p. 415
- 380 Current type Hz 1~50 3~50 3~60 Connected load kW 2.9 4.3 5.9 6.9 Protection (slow, char. C) A 13 16 Maximum allowed net impedance Ohm 0.365 -- Type of protection -- IPX5 Extension cord 30 m mm p. 480
Sound pressure level L
:87 :90 HD 9/18-4 :84 :87 Chairman of the Board of Management Director Regulatory Affairs & Certification 383TH– 11
ManualGo.com