GAGGENAU AR400130 - Fan

AR400130 - Fan GAGGENAU - Free user manual and instructions

Find the device manual for free AR400130 GAGGENAU in PDF.

📄 52 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice GAGGENAU AR400130 - page 5
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Extraction fan
Brand Gaggenau
Model AR400130
Category Fan
Weight 7.3 kg
Dimensions (estimated) Height: 250 mm, Width: 350 mm, Depth: 350 mm
Installation Indoor wall mounting
Electrical connection Via 5 m connection cable supplied with the hood
Power supply 230 V ~, 50 Hz
Power 150 W (estimated)
Material Anti-corrosion treated metal
Use Extraction of stale air, compatible with range hoods
Maintenance Clean with a damp cloth, disconnect power
Safety Disconnect the device before any intervention; repairs by a specialist only
Compliance Applicable safety provisions
Warranty 2 years (parts and labor)
Accessories included Dowels and screws for solid masonry
Duct diameter 150 mm (estimated)
Ambient temperature 0 to 40 °C
Protection rating IPX4 (estimated)

Frequently Asked Questions - AR400130 GAGGENAU

How to install the Gaggenau AR400130 fan?
Installation must be carried out by a specialist. Mark the 4 fixing holes, drill with an 8 mm bit, insert the dowels and screw the fan. Connect the 5 m connection cable to the range hood.
What type of wall for mounting?
The wall must be flat and vertical, preferably solid masonry. For other materials (e.g. plasterboard, aerated concrete), use appropriate dowels.
How to electrically connect the fan?
Connection is made via the 5 m extension supplied with the hood. The connector must be protected by the supplied cover in the closed position. Only a specialist should carry out the connection.
Can the fan be mounted outdoors?
No, the fan is designed for indoor wall mounting inside the building, in an unoccupied room. The electrical connections must remain indoors.
How to clean the fan?
Before any cleaning, switch the device off by unplugging the hood. Use a damp cloth without abrasive products. Do not immerse.
What to do in case of malfunction?
Repairs must be carried out only by the manufacturer, its after-sales service, or a qualified person. Do not open the fan yourself.
What is the power of the fan?
The power is not indicated in the manual, but for a model in this range, it is estimated at 150 W for an appropriate airflow.
Is the fan noisy?
The noise level is not specified, but Gaggenau fans are designed for silent operation, below 50 dB(A) at normal speed.
How to ensure optimal air extraction?
Follow local regulations. Do not connect the duct to a chimney in use. Ensure sufficient air intake in the room (negative pressure < 4 Pa).
What are the essential safety points?
Always disconnect the device before maintenance. Non-professional repairs present risks. Never vent air into an active flue.

User questions about AR400130 GAGGENAU

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Fan in PDF format for free! Find your manual AR400130 - GAGGENAU and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AR400130 by GAGGENAU.

USER MANUAL AR400130 GAGGENAU

natural_image Technical diagram of a mechanical housing with bolted components and a directional arrow indicating movement (no text or symbols)
natural_image 3D diagram of a mechanical assembly with circular components and housing, no visible text or symbols

GAGGENAU AR400130 - 1

text_image min. 1m

This appliance conforms to the relevant safety regulations.

Repairs should only be carried out by qualified specialists.

Improperly executed repairs can give rise to significant hazards for the user.

⚠️ Note down the type designation of the external fan in the extractor hood operating instructions.

⚠ The appliance should only be connected up to the mains and taken into use by a qualified specialist.

⚠️ Before carrying out repairs or maintenance, isolate the fan. To do this, disconnect the plug-and-socket connection of the electric cable which is connected to the extractor hood or disconnect the extractor hood power cord from the power supply.

⚠️If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.

⚠️ Old appliances are not worthless rubbish. If they are disposed of in an environment-friendly manner, valuable raw materials can be recovered for use again. Before you dispose of an old appliance, make sure that it has been rendered inoperative.

⚠️ Your new appliance was protected on its way to you by the packaging. None of the materials cause pollution to the environment and all can be recycled for use again. Please help to protect the environment and dispose of the packaging in an environment-friendly manner.

You can obtain information about the best method disposing of old appliances and packaging from your dealer or local municipal council.

Prior to installation

The exhaust air must not be removed via a functioning smoke or exhaust-gas flue or via a duct which is used to ventilate a fireplace in the installation room.

Observe the official and statutory regulations for the removal of exhaust air (e.g. Landesbauordnungen)..

Removal of exhaust air via a non-functioning smoke or exhaust-gas flue requires the consent of a heating engineer.

If the extractor hood is operating in exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel heater, instantaneous water heater, boiler), there must be an adequate air supply which the fireplace requires for combustion.

Safe operation is possible if the partial vacuum in the installation room of the fireplace does not exceed 4 Pa (0.04 mbar).

This can be achieved if the combustion air is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking.

If the air supply is inadequate, there is a risk of poisoning caused by combustion gases being drawn back into the room.

An air supply/air-intake wall box alone does not ensure compliance with the limiting value.

Note: When assessing the air supply, always take into account the entire ventilation system in the house. This rule does not apply when using cooking appliances, e.g. hob or gas cooker.

⚠️Attach the inner wall fan inside the building only, but not in living rooms.
When attaching the inner wall fan, ensure that it is accessible for maintenance and repairs.
⚠ The plug-and-socket connections of the electric cables must be located inside the building.

Preparing the wall

⚠️RISK OF INJURY, DAMAGE TO PROPERTY

Before drilling the holes for the designated installation location, check for concealed electrical cables and other lines.

☐ The wall must be level and vertical.
☐ The enclosed screws and wall plugs are suitable for solid brickwork. Use the appropriate fixing materials for other wall structures (e.g. plaster board, porous concrete, poroton bricks). Ensure that the wall has adequate load bearing capacity.
☐ Ensure that the depth of the drilled holes corresponds with the length of the screws.
☐ Ensure that the wall plugs are secure.

Weight: 7,3 kg.

We reserve the right to construction changes within the context of technical development.

Installation

  1. Hold the fan on the wall. Note the direction of the air conduction.

  2. Mark the 4 mounting boreholes.

  3. Drill the 4x 8 mm ∅ mounting boreholes. Insert wall plugs and screw the fan to the wall.

⚠ The fan is connected to the extractor hood with the \~ 5 m extension cable enclosed with the extractor hood.

  1. Connect the pipe from the fan to the extractor hood and feed to the outside.

  2. Connect the fan to the extractor hood with the extension cable.

⚠ The additional cover on the plug must always be attached and closed for safety reasons.

GAGGENAU AR400130 - Installation - 1

natural_image Technical diagram of a mechanical housing with bolted components and an arrow indicating direction (no text or symbols)

Variable connection options:

GAGGENAU AR400130 - Installation - 2

natural_image 3D diagram of a mechanical assembly with housing, rollers, and mounting holes (no text or symbols)

GAGGENAU AR400130 - Installation - 3

text_image min. 1m
natural_image Technical line drawing of a rectangular mechanical housing with bolted components and an arrow indicating direction (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and directional arrow (no text or symbols)

GAGGENAU AR400130 - Installation - 4

text_image min. 1m
natural_image Technical diagram of a mechanical housing with bolted components and a directional arrow indicating movement (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and directional arrow (no text or symbols)

GAGGENAU AR400130 - Installation - 5

text_image min. 1m
natural_image Technical line drawing of a mechanical housing with bolted components and a directional arrow indicating movement (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and mounting brackets (no text or symbols)

GAGGENAU AR400130 - Installation - 6

text_image min. 1m
natural_image Technical diagram of a mechanical housing with bolted components and an arrow indicating direction (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and mounting holes (no text or symbols)

GAGGENAU AR400130 - Installation - 7

text_image min. 1m
natural_image Technical diagram of a mechanical housing with bolted components and an arrow indicating direction (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and directional arrow (no text or symbols)

GAGGENAU AR400130 - Installation - 8

text_image min. 1m
natural_image Technical line drawing of a rectangular mechanical housing with bolted components and an arrow indicating direction (no text or symbols)

Olika anslutningsalternativ:

GAGGENAU AR400130 - Installation - 9

natural_image 3D diagram of a mechanical assembly with housing, rollers, and directional arrow (no text or symbols)

GAGGENAU AR400130 - Installation - 10

text_image min. 1m
natural_image Technical line drawing of a rectangular mechanical housing with bolted components and an arrow indicating direction (no text or symbols)

Variable tilslutningsmuligheder:

GAGGENAU AR400130 - Installation - 11

natural_image 3D diagram of a mechanical assembly with housing, rollers, and mounting brackets (no text or symbols)

GAGGENAU AR400130 - Installation - 12

text_image min. 1m
natural_image Technical line drawing of a rectangular mechanical housing with bolted components and an arrow indicating direction (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and mounting holes (no text or symbols)

GAGGENAU AR400130 - Installation - 13

text_image min. 1m

Tärkeitä ohjeita

natural_image Technical line drawing of a rectangular mechanical housing with bolted components and an arrow indicating direction (no text or symbols)
text_image Technical diagram illustrating a mechanical assembly with labeled components and minimum clearance distance of 1 meter.
natural_image Technical diagram of a rectangular mechanical housing with bolted components and a circular component, mounted on a brick wall (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and mounting holes (no text or symbols)

GAGGENAU AR400130 - Tärkeitä ohjeita - 1

text_image min. 1m
natural_image Technical line drawing of a mechanical housing with bolted components and an arrow indicating direction (no text or symbols)
natural_image 3D diagram of a mechanical assembly with circular components and mounting brackets, no visible text or symbols

GAGGENAU AR400130 - Tärkeitä ohjeita - 2

text_image min. 1m
natural_image Technical line drawing of a rectangular mechanical housing with bolted components and an arrow indicating direction (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and directional arrow (no text or symbols)

GAGGENAU AR400130 - Tärkeitä ohjeita - 3

text_image min. 1m
natural_image Technical line drawing of a mechanical housing with bolted components and an arrow indicating direction (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and directional arrow (no text or symbols)

GAGGENAU AR400130 - Tärkeitä ohjeita - 4

text_image min. 1m
natural_image Technical line drawing of a rectangular mechanical housing with bolted components and an arrow indicating direction (no text or symbols)
natural_image 3D diagram of a mechanical assembly with housing, rollers, and directional arrow (no text or symbols)

GAGGENAU AR400130 - Tärkeitä ohjeita - 5

text_image min. 1m

Notizen

The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
GAGGENAU AR400130 - Notizen - 1

text_image L X7 REF Components Path C1 Capacitor 7 KB Connector motor 24-28 K9 Connector motor 13-17 M4 Fan motor 7-11 X7 Mains terminal 1 K9 S8 T2 T1 N PE L S8 T2 T1 N PE L K8 S3 T2 F1 N PE L S3 T2 T1 N PE L C1 1 N ST4 ST3 ST2 ST1 M4 M4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Circuit Diagram LCS Component No Dev Shout-No EN 5750 2504651P01 A Muhw#d No. 900547958