Tecnotronic 7616 - Pump HOZELOCK - Free user manual and instructions
Find the device manual for free Tecnotronic 7616 HOZELOCK in PDF.
| Brand | HOZELOCK |
| Model | Tecnotronic 7616 |
| Type | Automatic pump controller |
| Power supply | 220-240 V~, 50 Hz, 10 A |
| Max flow rate | 10,000 l/h |
| Max pressure | 10 bars |
| Operating pressure | 1.45 bars (±10%) |
| Protection rating | IP55 |
| Max water temperature | 35°C |
| Max ambient temperature | 55°C |
| Power cable | H07 RN-F, 1.2 m minimum |
| Inlet connection | 1"1/4 female |
| Outlet connection | 1" male |
| Functions | Automatic start/stop, dry-run protection |
| Indicators | Green light (power on), yellow (pump running), red (alarm) |
| Control | Reset button (RESET) |
| Weight (estimated) | Approx. 1 kg |
| Dimensions (estimated) | Approx. 200 x 150 x 100 mm |
| Maintenance | Protect from frost |
| Safety | Requires a 10 or 30 mA earth leakage circuit breaker and earthing |
| Warranty | 2 years contractual (subject to conditions) |
Frequently Asked Questions - Tecnotronic 7616 HOZELOCK
User questions about Tecnotronic 7616 HOZELOCK
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Pump in PDF format for free! Find your manual Tecnotronic 7616 - HOZELOCK and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Tecnotronic 7616 by HOZELOCK.
USER MANUAL Tecnotronic 7616 HOZELOCK
natural_image
Exterior view of a HOZELOCK industrial pump with attached electrical plug (no text or symbols visible on the device itself)In case of doubt, french instructions are the reference

Special warning, read carefully
Précautions particulères, lire attentivement
- Directive ROHS 2011/65/EU
For safety reasons, this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
1 - SAFETY MEASURES READ CAREFULLY BEFORE USE
The user is responsible to third parties for all matters resulting in the use of the product (electrical, hydraulic installation, etc ...). In France, comply with standard NF C15-100 of 07/00, which governs low voltage electrical installations. In other countries, comply with local regulations.
Before using the product, it is therefore advisable to have an experienced electrician check that the necessary safety measures on the electrical network are observed.
The supply characteristics indicated on the rating label must correspond to the characteristics of the electrical network.
For reasons of security, the electrical network that powers your product must be equipped with a Residual current device (10mA or 30mA) and grounded plugs.
For use in swimming pools, ponds and fountains, the Tecnotronic must always be securely set up on a flat and dry surface.
If you add an extension cord, it must be of type H07 RN-F with the same section as the power cable of your product, with a waterproof connection plug.

Never carry Tecnotronic by the cables.
Before each use, check that the power cable is in good condition; do not use the product otherwise.

Do not make any changes to the product. Do not modify or attempt to access the product in any way.
If the appliance or the supply cord is damaged, it must be repaired by manufacturer, its service agent or qualified person.
Our guarantee is excluded for the normal wear of the material, deterioration or accidents resulting from a faulty and abnormal use of the equipment, or due to a modification of the product or an intervention on the electric part.

In case of non-compliance with the instructions, the user incurs a risk that can lead to electrocution.
2 - AREA OF APPLICATION
The Tecnotronic is used to change an electric pump into an automatic pump for domestic use and has 2 functions:
- it allows the pump to be operated automatically: it starts it up when the tap is turned on and stops it about 15 seconds after the tap is turned off.
- it protects the pump from operating when dry: the safety system automatically stops the pump when there is no water suction and therefore prevents any possible damage. When the pump stops, this is signalled by the RED INDICATOR (4) coming on, on the control panel.
The water pumped out must not exceed a temperature of 55^ C.

Attention: This product is not suitable for use with salt water, corrosive products, flammable, explosive or food liquids.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.

The packaging of the product is recyclable. The device and its accessories contain materials (including plastics) which can be recycled.
3 - TECHNICAL SPECIFICATIONS AND PERFORMANCE
Operating conditions:
- In operation: pressure = 1.45 bars
- Stopped: pump maximum pressure
Values are given ±10%
Electrical data
Max. flow
Maximum pressure
Power cable
Level of protection
Max.water temperature
Max. ambient temperature
Rated impulse withstand voltage
Tecnotronic
| 220-240V~ - 50Hz - 10A |
| 10 000 l/h |
| 10 bars |
| H07 RN-F - 1,2m min. |
| IP55 |
| 35°C |
| 55°C |
| 2500V |
4 - DESCRIPTION (fig.1)
1 - « On » indicator (GREEN indicator)
2 - « Reset » button (RESET indicator)
3 - Pump in operation indicator (YELLOW indicator)
4 - Alarm indicator (lack of water or malfunction) (RED indicator)
5 - Exit with 1" male threaded connector
6 - Supply cable
7 - Pump connection cable
8 - Entry with 1"¼ female threaded connector
5 - PREPARATION - FIRST USE
The Tecnotronic is assembled on the delivery port of the pump by screwing the 1"¼ female entry connector (8) onto the male thread of the pump. If the pump has a different exit from a 1"¼ male one, an intermediate connector (provided) must be used (fig.2). After fitting the Tecnotronic, connect the connection cable (7) to the pump.
Before connecting the suction hose to the pump, fit a filter to stop impurities to the suction hole of the pump. The use of the filter is necessary to prevent any damage to the Tecnotronic and consequently any operating problems.

Warning: Before use, it is necessary to fill the pump and the suction hose completely with water, in order to allow priming. In cases
where the water level is lower than the pump, then a suction hose with a non-return valve must be used. This allows them to be filled for the first use and prevents them from emptying when the pump stops automatically, thus avoiding any problems when the pump is restarted.
The Tecnotronic system is delivered with supply cables. Connect the supply cable (6) to the electricity supply. If the suction phase does not start within 120 seconds, the pump stops automatically and the cause of the malfunction must be determined.
6 - PANEL AND INDICATORS
The Tecnotronic is equipped with a control panel with three luminous diodes which indicate the operating condition of the pump:
- GREEN INDICATOR (1): It comes on when the Tecnotronic is connected to the electricity supply.
- YELLOW INDICATOR (3): Lights up when the pump starts and goes out when it stops.
- RED INDICATOR (4): Lights up when operation is prevented due to a lack of water at suction or if the pump breaks down.
- RESETTING BUTTON (RESET - 2): This serves to restart the pump when a regular water supply has been re-established.
NB : In the case where it does not start up, always check that the suction hose is full of water.
6 - MAINTENANCE AND STORAGE
Keep the system in a place that does not freeze.
7 - OPERATING ANOMALIES / SOLUTIONS
| Incidents | Causes Solution | |
| The red indicator (3) lights up. | No water. Restore the water supply. | |
| The pump starts and stops all the time. | 1- The circuit is not sealed.2- Probable presence of foreign bodies inside the Tecnotronic. | 1-Check the circuit and the different connections to the pump.2- Disconnect the power supply, remove the Tecnotronic from the pump and rinse it completely with a water jet through the entry side (8), with a garden hose for example. |
| The pump does not work. | 1- The pump has broken down.2- The Tecnotronic is maybe blocked with limescale.3- The pump is not primed. | 1- After disconnecting the Tecnotronic from the pump electrically and hydraulically, try to make the pump work alone by connecting it to the power supply.2- If, through the exit hole (5), you see that the check valve is jammed, wash it by filling the Tecnotronic with vinegar or another anti-limescale product through the exit hole. If the check valve is operating correctly, contact the after-sales department.3- Prime the pump (see the pump instructions)- see chapter 5 of these instructions |
For any other anomaly, contact our after-sales service. For safety reasons, only the Hozelock-Exel after-sales service is entitled to disassemble the pump.
8 - GUARANTEE
Extended Contractual Warranty
We guarantee our products for a period stated on the product from their date of purchase (Mandatory Contractual Warranty cover extended to 2 years + Extension of our Contractual Warranty).
In the event of failure to present proof of the product date of purchase, the Warranty is effective from the product date of manufacture (stated on the product).
Contractual warranty exclusions
The contractual warranty does not apply in the following cases:
-The normal wear parts: seals, mechanical seals,
-The products that are used in violation of the technical recommendations,
- Products used improperly,
- Products that are not regularly maintained
- Damage to products (impacts, drops, crushing, etc.) caused due to negligence, improper maintenance, improper or abnormal use of the product,
- Replacement of a component following a loss.
Warranty activation
Please keep your proof of purchase (invoice or legible till receipt), as this will be required in the event of a claim under the Contractual Warranty.
A product under warranty that has been repaired or replaced, remains guaranteed for the remaining duration and under the original terms of the Contractual Warranty granted at the time of purchase. All returned products become the property of HOZELOCK-EXEL when replaced by a new product.
The Contractual Warranty, the terms of which are described above, does not replace the Legal Warranty.
9 - EC DECLARATION
I, the undersigned, Philippe MAREY – Quality Manager - hereby certify that the product
Brand: HOZELOCK
Model: Tecnotronic
Ref: 7616 1240
Was developed, designed and manufactured in accordance with all relevant provisions of the following directives:
- LVD Directive 2014/35/EU
- ROHS directive 2011/65/EU
Made in Villefranche the 21/12/2017

text_image
MaverD
INHALT
4 - BESCHRIJVING (fig.1)
INNEHÄLLSFÖRTECKNING
7 - VEDLIKEHOLD OG OPPBEVARING
Produktet må oppbevares frostfritt.
8 - FUNKSJONSFEIL / L∅SNINGER
3 - TEKNISET OMINAISUUDET JA TOIMINNOT
Käytön ehdot: