AD 7972 - Humidifier ADLER - Free user manual and instructions
Find the device manual for free AD 7972 ADLER in PDF.
Download the instructions for your Humidifier in PDF format for free! Find your manual AD 7972 - ADLER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AD 7972 by ADLER.
USER MANUAL AD 7972 ADLER
Clean the water tank every 3 days.
Figure 7 Figure 8 Figure 9A 9B 9C 9D 9E6 ENGLISH ENGLISH
GENERAL SAFETY CONDITIONS
IMPORTANT SAFETY INSTRUCTIONS READ CAREFULLY AND SAVE FOR FUTURE The warranty conditions are different, if the device is used for commercial purpose. 1.Before using the product please read carefully and always comply with the following instructions. The manufacturer is not liable for damages caused by using the device contrary to its intended purpose or improper operation. 2.The device is for home use only. Do not use for other purposes that are not for its intended purpose. 3.The device should only be connected to a 220-240 V ~ 50/60 Hz socket.
4. Take special care when using the device when children are nearby. Do not allow children
to play with the device, do not allow children or people unfamiliar with the device to use it.
5. WARNING: This equipment may be used by children over 8 years of age and people
with limited physical, sensory or mental ability, or people who have no experience or knowledge of the equipment, if this is done under the supervision of a person responsible for their safety or have been granted them information on the safe use of the device and are aware of the dangers of using it. Children should not play with the equipment. Cleaning and maintenance of the device should not be performed by children, unless they are over 8 years old and these activities are carried out under supervision. 6.Always remove the plug from the power socket after use by holding the socket with your hand. DO NOT pull on the power cord.
7. Do not immerse the cable, plug, base and the whole device in water or any other liquid.
Do not expose the device to atmospheric conditions (rain, sun, etc.) or use in conditions of high humidity (bathrooms, damp mobile homes).
8. Periodically check the condition of the power cord. If the power cord is damaged, it
should be replaced by a specialist in repair center to avoid danger. 9.Do not use the device with a damaged power cord or if it has been dropped or damaged in any other way or if it is not working properly. Do not repair the device yourself, as there is a risk of electric shock. Take the damaged device to an appropriate service center for checking or repair. All repairs may only be carried out by authorized service points. Incorrectly performed repairs can cause serious danger for the user.
10. Place the device on a cool, stable surface, away from hot kitchen appliances such as
an electric stove, gas burner, etc.
11. Do not use the device near flammable materials.
12.The power cord may not hang over the edge of a table or touch hot surfaces. 13.Never leave the product connected to the power source without supervision. Even when use is interrupted for a short time, turn it off from the network, unplug the power.
14. To provide additional protection, it is advisable to install a residual current device (RCD)
in the electrical circuit with a rated residual current not exceeding 30 mA. Ask an electrician for this.
15. Do not use the device near water, e.g. ... in the shower, bath tub or above the7
wash basin with water.
16. When the appliance is used in a bathroom, remove the plug from the socket after use,
as the proximity of water is a hazard even when the appliance is turned off.
17. Do not allow the device to get wet. In the event that the device falls into water,
immediately remove the plug from the wall socket. Do not put your hands in water when the machine is connected to the network. It must be checked by a qualified electrician before using it again.
18. Do not hold the device with wet hands.
19. Always turn off the device after every use. Please switch off power before unplugging.
20. Never turn on the device without water in the water tank.
23. Do not immerse the humidifier base. If water spills on the device, immediately unplug it
and allow it to dry.
24. Do not add any chemicals to the water basin, water tank or the mist outlet. Do not add
salts, descaling tablets, powders or cleaning substances to the water.
25. The mist inlet and water tank cover should always be tightly closed.
26. Make sure the humidifier's mist outlet is not directed directly at walls, furniture, electrical
outlets, electrical and electronic devices, or children. Too high humidity in a room can lead to moisture accumulation, causing bacteria and fungi to grow, and damage to walls, furniture, and wallpapers.
27. Do not block the ventilation of the device. Keep a distance of at least 20 cm from the
device. Do not block the humidifier water mist outlet.
28. Do not use the device if there is a risk of condensation. Moisture can form on the inside
and outside of the device when: - the device is moved from a cold to a warm place, - the heating system has just been switched on, - the device is used in a room with high humidity, - the device is cooled by the air conditioning cooling system. When moisture condensation occurs in the device, it may not work properly or may be damaged in extreme cases. In this case, do not use the device and let it dry for a few hours.
29. Do not tilt, turn over or attempt to top up or pour water from the machine during
30. Do not remove the tank from the base of the device during operation of the humidifier.
31. The filled water tank is heavy. When carrying it, keep it underneath as well.
32. Do not use a humidifier if you find water leaks from under the device.
33. Do not leave water in the humidifier when it is not being used.
34. Follow the cleaning instructions in this manual.
35. Never allow sedimentation, moisture or water to remain in the humidifier base tank (this
may cause contamination or even damage to the ultrasonic atomizer).
36. During prolonged operation of the device, the water mist emitted by the humidifier may
fall to the floor and cause moisture.8
37. Do not lift the water tank by the water mist outlet.
38. It is prohibited to insert metal chips, wire, needles and other foreign objects into the
product or into the housing gaps, otherwise it may cause electric shock or malfunction.
39. Be aware that high humidity levels may encourage the growth of biological organisms
and fungi in the environment.
40. Too much humidity in the room can lead to moisture accumulation causing the damage
to walls, furniture, wallpaper and electric other appliances as TV. Do not direct the mist outlet close to such objects.
41. Do not permit the area around the humidifier to become damp or wet. If dampness
occurs, turn down the mist production. If the mist capacity cannot be turned down, use the humidifier intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
42. Do not cover the device. Do not place any objects on the top of the device.
43. Do not use the device in association with a programmer, timer or other device that
automatically switches the humidifier on.
Warning: Microorganisms that may be present in the water tank will be blown into the air,
causing a very serious health hazard. To prevent this, change the water regularly and clean the tank every three days.
Warning: The water tank should be emptied and refilled every three days. Before refilling,
clean it with fresh water or using available detergents if required by the manufacturer. Remove scale, deposits or a film that has formed on the walls of the tank. After cleaning, wipe dry all accessible surfaces. Ultrasonic humidifier uses ultrasonic high frequency oscillation principle, the water is atomized into 1-5 micron ultra fine particle, then the water mist is diffused into the air through the pneumatic device, so as to achieve the purpose of uniformly humidifying the air, refreshing air, moisturizing skin and improving health. Before first use When the device is turned on, please do not touch an atomizing transducer (12) with hand to avoid hurting. Device description: Ultrasonic humidifier 1.Water filling lid 2.Water tank cover 3.Spray nozzle 4.Aromatherapy container 5.Mist air duct 6.Water tank 7A. Switch on / Mist adjustment / Sleep mode / Switch off button 7B. Timer button 7C. Continuous humidity button 8.Display 9.Air inlet 10.Mist outlet 11.Air outlet
WATER FILLING – look at figure 7
1. Place the device on stable, flat surface. Remember to fill the water to unplugged device.
2. Open the water filling cover (2) together with water filling lid (1).
3. Remember the mist air duct (5) has to be installed inside water tank before adding the water.
4. When adding the water, do not inject water into the spray nozzle (3) and do not inject water into the mist outlet (10) as well do not inject water into the air outlet (9).9 5. Pay attention to do not exceed the MAX (maximum) water level marked on the air outlet (9) - llok at Figure 2. Use clean tap water.
6. Close the water tank cover (2) together with water filling lid (1). Plug in the device.
7. When the device is not planned to be used the water should be poured out the water tank (6).
8. To reduce the precipitation of limescale from the water - white powder, you can optionally purchase a water filter for this device, number AD7972.1 from the seller of this device. AROMATHERAPY FUNCTION
1. Take away the water tank cover (1) together with water filling lid (1).
2. Pour 2-3 drops of essential oil on an aromatherapy cotton sponge (13) and place it inside an aromatherapy container (4). Look at Figure 4. Place an aromatherapy container (4) on the top of the mist outlet (10). The nice smelt will be distributed together with mist. ATTENTION: ONLY water-soluble essential oils are suitable for this device.
3. DO NOT drip essential oils to water directly.
1. After plug in the device gives sound signal and the device enters the standby state.
2. To switch on the device press once the switch on button (7A). Default mist volume is set at low level, you will see at the display (8) two lines (Figure 9B). Press this button (7A) repeatedly to change the modes to medium mist output level (Figure 9C), high mist volume (Figure 9D), sleep mode (Figure 9D) or switch off the device (Figure 9E) in turn.
WATER SHORTAGE PROTECTION
When the device is working, built-in spring detect the lack of water. Then the device stops working, the display (8) will show “EE” and flashing for 5 seconds and you will hear 3 sound signals. After this, the device enters the standby state. After adding the water, press the switch on button (7A), then the device can work normally.
The device will work at medium mist output for 5 minutes and it will pause the mist output for 5 minutes, then it works 5 minutes and it will pause for 10 minutes; next it will work for 5 minutes and it will pause for 15 minutes, further operation will be continued in such cycle. At sleep mode the display (8) is dimmed – look at Figure 9E. TIMER SETTING The default setting is zero hours. During operation press the timer button (7B) repeatedly to choose one of timer operation period: 1 hour or 2 hours or 4 hours or 6 hours or press again to switch off the timer function – look at Figure 4. The timer function stops the operation of device after fixed period passed.
HUMIDITY LEVEL SETTING
During the device operation press the continuous humidity button (7C), you can set the humidity value in range 40-90% of relative humidity, each repeated pressing will increase with 5% value. When the humidity level is set, the device is constantly humidifying to the desired humidification level. After reach desired humidification level, the device enters the standby state and stops spraying the mist until the ambient humidity level reduced to 5% below desired humidification level. In such case, the device starts spray the mist again automatically. Look at Figure 5.
CLEANING AND MAINTENANCE
1. Plug out the device before cleaning. If there is some water left in the water tank (6), it should be poured out by tilting the water tank (6). ATTENTION: Important issue is correct water tank (6) position while the water is poured out. The correct position is achieved when the air outlet (9) stay dry and the water stream is leaded by opposite edge of the water tank (6).
2. Clean the water tank each 3 days.
3. After the device is used for a period of time, it is easy to appear scale and form “white powder” phenomenon, it is attached to the surface of an atomizing transducer (12), affecting the humidification efficiency. It is necessary to clean main components regularly. To clean main components look at Figure 6.
- Open the water tank cover (2), disassemble the mist air duct (5) by rotating anticlockwise – look at Figure 6A.
- Wipe the inside of water tank (6) and the mist air duct (5) with a soft cloth – look at Figure 6B.
- Add proper amount of water, clean the device with the cleaning brush (14) – look at Figure 6C.
- Wipe an atomizing transducer (12) with a cotton swab stuck with citric acid solution.
4. Do not use sharp hard utensils to touch the atomizer.
5. Do not use detergent to clean, clan water is better. Next dry elements with soft cloth, install the mist air duct (5) by clockwise rotation. 6. The outer surface of the device housing can be cleaned with a damp cloth and then wiped dry with a clean cloth. Do not use chemical solvents, gasoline, kerosence or polishing powder to wipe the surface.
ManualGo.com