PVKO 50 A1 - Air compressor PARKSIDE - Free user manual and instructions
Find the device manual for free PVKO 50 A1 PARKSIDE in PDF.
| Product type | Vertical air compressor |
| Brand | Parkside |
| Model | PVKO 50 A1 |
| Rated voltage | 230 V ~ 50 Hz |
| Rated power | 1800 W |
| Motor speed | 2850 min⁻¹ |
| Max. working pressure | 8 bar |
| Tank capacity | 50 L |
| Suction power | approx. 260 L/min |
| Protection type | IPX0 |
| Sound pressure level | 71.9 dB(A) (K_pA = 3 dB) |
| Measured sound power level | 90.9 dB(A) (K_WA = 2.29 dB) |
| Guaranteed sound power level | 93 dB(A) |
| Weight | approx. 26 kg |
| Air hose length | 10 m |
| Number of quick couplings | 2 |
| Safety valve | Yes |
| Air filter | Cleanable (every 300 h) |
| Condensate drain | Drain screw |
| Warranty | 3 years (France/Belgium) |
| Intended use | Pneumatic tools (inflator, paint spray gun, etc.) |
| Not intended for | Commercial use |
Frequently Asked Questions - PVKO 50 A1 PARKSIDE
User questions about PVKO 50 A1 PARKSIDE
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air compressor in PDF format for free! Find your manual PVKO 50 A1 - PARKSIDE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PVKO 50 A1 by PARKSIDE.
USER MANUAL PVKO 50 A1 PARKSIDE
Translation of the original instructions
NL BE
Verticale compressor 50 I
Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device.
FR B
GB/IE Translation of the original instructions Page
General description. 15
Scope of delivery. 16
Description of functions 16
Overview. 16
Technical data. 16
Safety instructions. 17
Symbols and icons 17
General Safety Instructions for Power
Tools. 17
Residual risks. 19
Initial start-up 19
Mounting the bow-type handle. 19
Fitting the wheels 19
Switching on/off 20
Operation 20
Mounting the compressed air hose....20
Working instructions 20
Adjusting the compressed air. 20
Cleaning and servicing. 20
Cleaning the air filter. 20
Draining the condensation water.....20
Checking the safety valve. 21
Storage. 21
Transport 21
Disposal/environmental
protection 21
Replacement parts/Accessories..21
Guarantee 22
Repair Service. 23
Service-Center. 23
Importer 23
Translation of the original
EC declaration of conformity .... 76
Exploded Drawing 83/84
Introduction
Congratulations on the purchase of your new device. With it, you have chosen a high quality product.
During production, this equipment has been checked for quality and subjected to a final inspection. The functionality of your equipment is therefore guaranteed.

The operating instructions constitute part of this product. They contain
important information on safety, use and disposal. Before using the product, familiarise yourself with all of the operating and safety instructions. Use the product only as described and for the applications specified.
Keep this manual safely and in the event that the product is passed on, hand over all documents to the third party.
Proper use
The compressor is intended for the operation of pneumatic tools (e.g. tyre inflator, blow-out gun and spray paint gun). The device is not suitable for operating tools that require a high degree of compressed air.
Any other use can damage the devices and thus pose a substantial risk to the user. These devices are not suitable for commercial use. The warranty is void in the case of commercial use.
The manufacturer is not liable for damage caused by improper use or incorrect operation.
General description

The illustration of the most important functional components can be found on the front and the back fold-out pages.
Scope of delivery
First, unpack the device and check for completeness.
- Compressor
- Bow-type handle
- 2 wheels
- Mounting material
- 10m compressed air hose
- Allen key
- Instruction manual
Dispose of the packaging material properly.
Description of functions
The compressor is intended for the operation of pneumatic tools.
Please refer to the descriptions below for information on how the operating elements work.
Overview
A
1 Air filter cover
2 Manometer (pressure vessel)
3 Safety valve
4 Pressure regulator
5 Manometer (set pressure)
6 On/off switch
7 Bow-type handle
8 Hose reel
9 Power cable
10 Pressure vessel
11 Wheel
12 Drain plug
13 Quick connectors
14 Compressed air hose
15 Allen key
B
7a Hexagon socket screw
0a Bracket for bow-type handle

16 Hubcap
17 Wheel bolt
18 Locknuts
E
1a Air filter
F
19 Power cable holder
Technical data
Vertical compressor 50 I.........PVKO 50 A1
Nominal voltage U. 230 V~; 50 Hz Rated power P. 1800 W
Motor speed n_0 2850 min max. working pressure
P max 1.0 MPa (10 bar)
Weight m. 35 kg
Vessel volume 501
Suction pipe approx. 260 l/min Protection type IPX0
Sound pressure level (L_pA) 71.9 dB(A), K_pA = 3 dB
Sound power level (L_WA)
measured.....90.9 dB(A), K_WA = 2.29 dB
guaranteed 93 dB(A)
Levels of noise and vibration were determined according to the standards and regulations in the declaration of conformity.
The specified total vibration value and the stated noise emission value have been measured according to a standardised test method and can be used to compare one power tool with another.
The specified total vibration value and the stated specified noise emission value can also be used for a provisional assessment of the load.
!
Warning: The vibration emission value may differ during actual use of the power tool from the stated value depending on the manner in
which the power tool is used. Try to keep the exposure to vibrations as low as possible. Examples of measures to reduce vibration exposure are the wearing of gloves when using the tool and limiting the working hours. For this purpose all parts of the operating cycle have to be considered (for example, times when the electric tool is switched off and times when it is switched on but running without any load).
Safety instructions
Ensure that the safety instructions are observed when operating the device.
Symbols and icons
Symbols in the manual:

Warning symbols with information on damage and injury prevention.

Hazard symbol with information on the prevention of personal injury caused by electric shock.

Instruction symbols with information on preventing damage.

Help symbols with information on improving tool handling.
Symbols on the device

Caution!
Danger of electric shock!

Warning! Compressor system can start without warning.

Caution! Hot surface!

Wear ear protection!

Read the instruction manual carefully.

Electrical devices do not belong in domestic waste.

Sound power level L WA indicated in dB
General Safety Instructions for Power Tools
The term "power tool" used in the safety instructions refers to mains-operated electric tools (with a mains cable) and to battery-operated electric tools (without a mains cable).
Safe working:
- Keep your work area tidy.
An untidy workplace can lead to accidents.
-
Consider environment influences.
-
Do not expose power tools to rain.
- Do not use power tools in damp or wet surroundings. The penetration of water into an electric tool increases the risk of electric shock.
- Ensure the work area is adequately lit.
-
Do not use power tools where there is a fire or explosion hazard. Power tools generate sparks that can ignite dust or vapours.
-
Protect yourself against electric shock.
GB E
Avoid body contact with earthed parts (e.g. pipes, radiators, electric cookers, refrigerators).
- Keep other people away. Do not allow other people, especially children, to touch the power tool or cable. Keep them away from your work area.
- Store unused power tools safely.
Unused power tools should be stored in a dry, high or locked place, out of the reach of children. There is a risk of injury.
- Do not overload your power tool.
They work better and more safely within the specified power range.
-
Use the correct power tool.
-
Do not use low-performance machines for heavy work.
- Do not use the power tool for purposes for which it is not intended. For example, do not use a circular hand saw for cutting tree branches or logs.
Using the power tool for anything other than its intended use can lead to dangerous situations.
-
Wear suitable work clothing.
-
Do not wear loose clothing or jewellery that might become caught in moving parts.
- When working outdoors, non-slip footwear is recommended.
-
Wear a hair net to contain long hair.
-
Use protective equipment.
-
Use a dust mask for work which generates dust.
-
Do not use the cable for purposes for which it is not intended.
Do not use the cable to pull the plug from the socket. Protect the cable from heat, oil and sharp edges. Damaged
or untidy cables increase the risk of electric shock.
- Avoid abnormal body postures. Ensure secure footing and keep your balance at all times.
This will help you to have better control of the power tool in unexpected situations.
-
Maintain tools with care. Many accidents are caused by poorly maintained power tools.
-
Follow the instructions for lubrication and changing tools.
Regularly check the connection cable of the power tool and, if it is damaged, have it replaced by a qualified specialist. - Check extension cords periodically and replace them if they are damaged.
-
Keep handles dry, clean and free from oil and grease.
-
Remove the plug from the mains socket when the power tool is not in use, before maintenance and when changing tools.
These safety measures prevent accidentally starting the power tool.
- Use extension cables outdoors.
Only use approved and appropriately marked extension cables outdoors.
- Pay attention at all times.
Pay attention, be aware of what you are doing and take the utmost care when working. Do not use the power tool if you cannot concentrate. A moment of inattention whilst using the power tool can result in serious injuries.
- Check the power tool for possible damage.
This will ensure that the power tool remains safe.
Before further use of the power tool, safety devices or slightly damaged
parts must be carefully examined in respect of their proper and intended function.
- Check whether the moving parts are working properly and are not becoming jammed or whether parts are damaged. All parts must be correctly fitted and satisfy all conditions to ensure the proper operation of the power tool.
- Damaged safety equipment and parts must be repaired properly or replaced by an authorised specialist workshop unless otherwise indicated in the instruction manual.
- Do not use power tools if the switch cannot be turned on and off. Damaged switches must be replaced at a customer service workshop.
- Caution!
Using other attachment tools and other accessories may represent a risk of injury to you.
- Have your power tool repaired by a qualified electrician. This power tool complies with the relevant safety regulations. Repairs may only be performed by a specialist workshop using original spare parts; otherwise accidents involving the user may result.
- If the connection cable of this device is damaged, it must be replaced by the manufacturer or their customer service or by a similarly qualified person in order to avoid hazards.
Residual risks
Even if properly operating and handling this electric tool, some residual risks will remain. Due to its construction and build, this electric tool may present the following hazards:
a) Cuts
b) Ear damage if working without ear protection.
c) Eye damage if suitable eye protection is not worn.
d) Damage to your health caused by swinging your hands and arms when operating the appliance for longer periods of time or if the unit is not held or maintained properly.

Warning! During operation, this electric tool generates an electromagnetic field which, under certain circumstances, may impair the functionality of active or passive medical implants. To reduce the risk of serious or lethal injuries, we recommend that persons with medical implants consult their doctor and the manufacturer of their medical implant before operating the machine.
Initial start-up

Mounting the bow-type handle
- Push the bow-type handle (7) into the bracket for the bow-type handle (10a) on the pressure vessel (10).
- Attach the bow-type handle (7) using the hexagon socket screws and the enclosed Allen key (15).

Fitting the wheels
- Insert the wheel bolt (17) through the hole in the wheel (11).
- Insert the wheel bolt (17) through the hole in the wheel rod.
- Fasten the wheel (11) using the locknuts (19). If necessary, use a spanner (not included in delivery).
GB E
- Press the hubcap (16) onto the wheel (11).
- Repeat steps 1-4 for the remaining wheels.
Switching on/off
- To switch the device on, move the On/Off switch (6) to position "l".
- To switch the device off, move the On/Off switch (6) to position "0".
Operation
D Mounting the compressed air hose
- Press the compressed air hose (14) into one of the two quick connectors (13). The compressed air hose (14) locks into place.
Removing the compressed air hose
- Press the coupling ring on the quick connector (13) towards the device. The compressed air hose (14) springs out of the quick connector (13).
- Press the compressed air tool into the quick connector on the compressed air hose.
Working instructions
A Adjusting the compressed air
The set pressure can be released from the quick connectors (13). This pressure can be adjusted via the pressure regulator (4) and can be read on the manometer (set pressure) (5).
- To increase, turn the pressure regulator (4) clockwise.
- To decrease, turn the pressure regulator (4) anti-clockwise.
Cleaning and servicing

Before carrying out work on the device, switch it off and unplug the mains plug.

You should have any repair and maintenance work that is not described in these instructions carried out by our Service Centre. Only use original parts.
Perform the following maintenance and cleaning work regularly. This will guarantee long and reliable use.
Always keep the ventilation slits on the device housing unobstructed otherwise the device will overheat.

Cleaning the air filter

Never run the device without an air filter. Dust and dirt may otherwise enter the motor and cause damage.
Remove dust and dirt from the air filter (1a) approx. every 300 operating hours to ensure proper functioning of the device.
- Remove the air filter cover (1).
- Remove the air filter (1a).
- Tap out the air filter (1a).
- Clean the air filter (1a) and the air filter cover (1) with a little compressed air (approx. 3 bar).
- Reverse the sequence to remount the air filter (1a) and the air filter cover (1).

Draining the condensation water
Empty condensation water from the pressure vessel (10) after every use.
- Open the drain plug (12).
- Collect the condensation water in a suitable container.
- Tilt forward slightly to let out the remaining condensation water.
- Close the drain plug (12) again.
Checking the safety valve
The safety valve is used to release the pressure in case of overpressure in the pressure vessel.
Activate the safety valve approx. every 30 operating hours, or at least 3 times a year to ensure correct functioning.
- Start the device (see "Switching On/Off")
- Rotate the safety valve (3) clockwise in order to open the safety valve (I). The safety valve (3) should now release air.
- Turn the safety valve (3) anti-clockwise to close the safety valve (3) again.
F Storage
Always store the devices and accessories:
dry.
clean.
- dust free.
-
out of the reach of children.
-
Wind the power cable (9) around the power cable bracket (19).
- Wind the compressed air hose (15) around the hose reel (8).
- Place the device upright if necessary.
- Release the overpressure in the compressor by switching off the compressor and using up the compressed air still present in the pressure vessel (10).
- Drain the condensation water (see ("Draining the condensation water").
Transport
Use the bow-type handle (7) to move the device. Pay attention to the weight of the device during transport.
Disposal/environmental protection
The device, accessories and packaging should be properly recycled.

Electrical devices do not belong in domestic waste.
- Take the device to a recycling plant. The plastic and metal parts used on your device can be properly sorted according to materials and grades and efficiently recycled. Please contact our service centre for more information.
We will dispose of any defective devices that you send to us free of charge.
Replacement parts/ Accessories
Spare parts and accessories can be obtained at www.grizzlytools-service.eu
If you have issues ordering, please use the contact form.
If you have any other questions, contact the "Service-Center" (see page 23).
Item Description Order No.
| 14 Compressed air hose 10m 91105933 |
| 1a Air filter 91105932 |
| 11 Wheel set 91105929 |
| 8 Hose reel 91105930 |
| 12 Drain plug 91105928 |
| 6 On/Off switch 91105931 |
| 13 Quick connectors set 91105926 |
Guarantee
Dear Customer,
This equipment is provided with a 3-year guarantee from the date of purchase. In case of defects, you have statutory rights against the seller of the product. These statutory rights are not restricted by our guarantee presented below.
Terms of Guarantee
The term of the guarantee begins on the date of purchase. Please retain the original receipt. This document is required as proof of purchase.
If a material or manufacturing defect occurs within three years of the date of purchase of this product, we will repair or replace - at our choice - the product for you free of charge. This guarantee requires the defective equipment and proof of purchase to be presented within the three-year period with a brief written description of what constitutes the defect and when it occurred.
If the defect is covered by our guarantee, you will receive either the repaired product or a new product. No new guarantee period begins on repair or replacement of the product.
Guarantee Period and Statutory Claims for Defects
The guarantee period is not extended by the guarantee service. This also applies for replaced or repaired parts. Any damages and defects already present at the time of purchase must be reported immediately after unpacking. Repairs arising after expiry of the guarantee period are chargeable.
Guarantee Cover
The equipment has been carefully produced in accordance with strict quality guidelines and conscientiously checked prior to delivery.
The guarantee applies for all material and manufacturing defects. This guarantee does not extend to cover product parts that are subject to normal wear and may therefore be considered as wearing parts (e.g. valve adapter, compressed air hose) or to cover damage to breakable parts (e.g. switches, tension tear protection, slide shoe).
This guarantee shall be invalid if the product has been damaged, used incorrectly or not maintained. Precise adherence to all of the instructions specified in the operating manual is required for proper use of the product. Intended uses and actions against which the operating manual advises or warns must be categorically avoided.
The product is designed only for private and not commercial use. The guarantee will be invalidated in case of misuse or improper handling, use of force, or interventions not undertaken by our authorised service branch.
Processing in Case of Guarantee
To ensure quick handling of you issue, please follow the following directions:
-
Please have the receipt and item number (IAN 356332_2004) ready as proof of purchase for all enquiries.
-
Please find the item number on the rating plate.
-
Should functional errors or other defects occur, please initially contact the service department specified below by telephone or by e-mail. You will then receive further information on the processing of your complaint.
-
After consultation with our customer service, a product recorded as defective can be sent postage paid to the service address communicated to you, with the proof of purchase (receipt) and specification of what constitutes the defect and when it occurred. In order to avoid acceptance problems and additional costs, please be sure to use only the address communicated to you. Ensure that the consignment is not sent carriage forward or by bulky goods, express or other special freight. Please send the equipment inc. all accessories supplied at the time of purchase and ensure adequate, safe transport packaging.
Repair Service
For a charge, repairs not covered by the guarantee can be carried out by our service branch, which will be happy to issue a cost estimate for you.
We can handle only equipment that has been sent with adequate packaging and postage.
Attention: Please send your equipment to our service branch in clean condition and with an indication of the defect.
Equipment sent carriage forward or by bulky goods, express or other special freight will not be accepted.
We will dispose of your defective devices free of charge when you send them to us.
Service-Center
GB Service Great Britain
Tel.: 0800 404 7657
E-Mail: grizzly@lidl.co.uk
IAN 356332_2004
IE Service Ireland
fei.: 1890 930 034
(0,08 EUR/Min., (peak))
(0,06 EUR/Min., (off peak))
E-Mail: grizzlyy@lidl.ie
IAN 356332 2004
Importer
Please note that the following address is not a service address. Please initially contact the service centre specified above.
P max 1,0 MPa (10 bar)
Poids m. 35 kg
Attention - surface chaude.

Chere cliente, cher client,
| GB IE | Translation of the original EC declaration of conformity |
| We hereby declare that the 50L Vertical Compressor model series: PVKO 50 A1 Serial number 000001 - 067500 conforms with the following applicable relevant version of the EU guidelines: | |
| 2006/42/EC • 2014/30/EU • 2014/68/EU • 2014/29/EU 2000/14/EC • 2005/88/EC • 2011/65/EU & (EU)2015/863* | |
| In order to guarantee consistency, the following harmonised standards as well as natio- nal standards and stipulations have been applied: | |
| EN 1012-1:2010 • EN 60204-1:2018 • EN IEC 63000:2018 EN 61000-6-1:2007 • EN 61000-6-3:2007/A1:2011 | |
| We additionally confirm the following in accordance with the 2000/14/EC emissions guideline: Sound power level Guaranteed: 93 dB(A); Measured: 90,9 dB(A) Compliance evaluation process carried out in accordance with Appendix VI, / 2000/14/EC and 2005/88/EC Registered Office: NB 0036; TÜV SÜD Industrie Service GmbH, Westendstrasse 199, 80686 München, Germany Design Type Certificate No.: Z-IS-AN1-MAN-20-08-2708744-04115611 | |
| This declaration of conformity is issued under the sole responsibility of the manfactu- rer: | |
| CE Grizzly Tools GmbH & Co. KG Stockstädter Straße 20 63762 Großbostheim Germany 05.12.2020 | Christian Frank Documentation Representative |
- The object of the declaration described above satisfies the provisions of Directive 2011/65/EU of the European Parliament and the Council of 8 June 2011 on limiting the use of certain harmful substances in electrical and electronic appliances.
Verticale compressor 50 I
bouwserie PVKO 50 A1
Serienummer
000001-067500