USER MANUAL Genial Light LANAFORM

2 / 44 “Genial Light” EN FR NL DE ES IT PT PL SK HU SL HR RU AR EN Instructions The photographs and other images of the product in this manual and on the pack- aging are as accurate as possible, but do not claim to be a perfect reproduction of the product. We would like to thank you for purchasing the GENIAL LIGHT from LANAFORM®. GENIAL LIGHT is an apparatus for dispensing light exposure. It is an ecient and practical means of allowing you to compensate for the lack of natural light. The GENIAL LIGHT provides a very bright light (approximately 10,000 lux) that simulates natural sunshine. You may use the GENIAL LIGHT while con- tinuing other activities such as reading, writing, using the telephone, or even your professional activities. The additional light provided by the GENIAL LIGHT during the duller seasons increases your exposure to light. It can have a positive inuence on your general mood. Having a GENIAL LIGHT means that you can appre- ciate the benets of sunlight even on the dullest of winter days.

ABOUT LIGHT EXPOSURE

Light and its intensity have a major inu- ence on our vital processes. During the seasons of autumn and winter, solar radia- tion decreases. Moreover symptoms result- ing from a lack of light may appear. Further- more classic articial lighting in buildings is not sucient to compensate for this lack of natural light. The consequences of this situation can lead to seasonal depression, a lack of energy, insomnia or melancholy, as well as the wide range of symptoms covered by the general expression “autumn or winter depression”. Light exposure consists of using a light source of high lux value to simulate the natural light of the sun. By un- dergoing regular exposure to a light source of high lux value over a certain period, the SAD (Seasonal Aective Disorder) symptoms can diminish or even disappear.

  • A lux is a unit of measurement of light. For example, a sunny summer’s day corresponds to approximately 50,000 lux, whereas the typical light intensity within a building is only about 500 lux.

IMPORTANT SAFETY MEASURES

  • Only use this appliance for the purposes described in this manual.
  • This appliance is not intended for use by persons (including children) whose phys- ical, sensorial or mental capabilities are impaired, or by persons lacking experience or knowledge, unless they are supervised or instructed in the use of the appliance rst by a person responsible for their safety. Chil- dren should be supervised to ensure that they do not play with the appliance.

Before connecting the appliance, check that the voltage indicated on the appliance corresponds to the mains supply voltage.

Please do not use accessories which are not recommended by LANAFORM® or which are not supplied with this appliance.

It is prohibited to modify this appliance in any way.

If the power supply lead is damaged, it must be replaced by a similar one available from the supplier or its after-sales service.

Do not use this appliance if the plug is damaged, if it is not working correctly, if it has been dropped or if it is damaged or if it has fallen into water. If this is the case, have the appliance inspected and repaired by the supplier or its after-sales department.

Do not transport this appliance by carry- ing it by its power lead and do not use this lead as a handle.

Always disconnect the appliance from the mains after use or before cleaning it.

An electrical appliance should never be left plugged in and unsupervised. Discon- nect it from the mains if you are not using it.

Keep the power lead away from hot surfaces.

Do not use this product before going to bed. Exposure to light has a stimulating eect which may inhibit sleep.

Never let anything fall into and never insert anything into one of the openings.

  • Do not use this appliance in a humid envi- ronment (in a bathroom, near a shower, etc.).
  • Never use this appliance in a room where aerosol products (sprays) are used or in a room where oxygen is administered.
  • Do not use this appliance under a cover or under a cushion. Excessive heat may cause a re, electrocution of the individual or other injuries.
  • This appliance is intended exclusively for family use. The use of GENIAL LIGHT is there- fore not equivalent to a medical treatment.
  • Do not use the appliance in a room which is not lit by another source of light, as this can lead to eyestrain. Use this appliance as a supplement for normal lighting (daylight or electric lighting).
  • If you feel any pain while using this appli- ance, stop using it immediately and consult your doctor.

We recommend that you do not look at the lamp during your session. Pain in the eyes may occur during the rst sessions; this will disappear afterwards.

Consult your doctor before using GENIAL LIGHT if: - you are suering or have suered from serious depression;“Genial Light ” 3 / 44 EN FR NL DE ES IT PT PL SK HU SL HR RU AR - you suer from hypersensitivity to light; - you are aicted with an eye disorder; - you are taking certain medications (e.g. certain antidepressants, psychotropic drugs, tablets for malaria) which could have a an eect contradicting the use of GENIAL LIGHT; - you have high blood pressure.

Exposure time depends in particular on the distance between you and the GENIAL LIGHT. Refer to the chapter on «Instructions for use» for the recommended distances and exposure times.

COMPONENTS 1 2 x 36W economic PPL uorescent tubes - colour 84 – giving more than 10,000 lux, with a life span of approxima- tely 8,000 hours 2 Reector hood 3 Folding tripod 4 Hole for wall-mounting 5 Electric power cable 6 Cover 7 On/O switch

INSTRUCTIONS FOR USE

  • Place your GENIAL LIGHT on a rm surface, such as a table and adjust the folding tripod. Plug the unit into the power supply and turn on the light by pushing the upper, white button.

It’s recommended to position of yourself near the light at a distance of 20 to 50 cm from the lamp depending the time of the session. At a distance of 20 cm, the exposure time should be about 1 hour. At a distance of 50 cm, the exposure time should be about 2 hours.

During the session, you can read, write, call, etc.

The exposure time depends upon your po- sition and distance from the light source. The nearer you are to the light, the shorter the session should last.

The exposure must be regular over a pro- longed period of time. During the dullest days of the year, repeat the treatment for 7 consecutive days at least, or more, according to individual requirements.

  • After use, switch o the machine by press- ing the white button at the top of the unit and unplug it from the power supply. WARNING

The GENIAL LIGHT is not a medical ins- trument.

  • Using the GENIAL LIGHT is not a medical treatment.

We suggest not to look at the lamp during the session. Eye pains or headaches may be experienced during the initial sessions; they will disappear during further sessions.

If recently you take or have taken me- dicines which may have a contradictory eect of the use of GENIAL LIGHT, please rst consult your doctor;

If your health deteriorates during your use of GENIAL LIGHT, please stop using the apparatus and consult your doctor.

The lamp must be switched o and unplugged from the power supply before being cleaned.

  • Use a damp cloth or sponge to clean the surface of the lamp.
  • Never submerge the GENIAL LIGHT in any liquid; and do not use your GENIAL LIGHT in a damp environment. Storage :
  • Put your unit away in a dry and safe place, out of the reach of children.

REPLACING THE LIGHT TUBES

  • The GENIAL LIGHT operates using two PPL 36W tubes.
  • Switch o the lamp and unplug it before replacing the light tubes.

Remove the screws holding the rear panel of the unit.

BESCHRÄNKTE GARANTIE

7 - Interruptor On/O

MANUTENCAO E ARRUMACAO