TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Air-conditioner

SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E - SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E - RAS-B10UFV-E1 - RAS-B13UFV-E1 - RAS-B18UFV-E1 - Air-conditioner TOSHIBA - Free user manual and instructions

Find the device manual for free SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E - SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E - RAS-B10UFV-E1 - RAS-B13UFV-E1 - RAS-B18UFV-E1 TOSHIBA in PDF.

📄 84 pages English EN Download 💬 AI Question 11 questions ⚙️ Specs
Notice TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Reversible split air conditioner (heating and cooling)
Models concerned RAS-B18N3KV2-E + RAS-18N3AV2-E, RAS-B22N3KV2-E + RAS-22N3AV2-E, RAS-B10UFV-E1, RAS-B13UFV-E1, RAS-B18UFV-E1
Power supply 230 V / 50 Hz (standard estimate)
Capacity (estimated) Approx. 3.5 kW (12,000 BTU/h) for B10, 4.5 kW (15,000 BTU/h) for B13, 5.3 kW (18,000 BTU/h) for B18, 6.4 kW (22,000 BTU/h) for B22
Operating modes Automatic, Cooling, Heating, Fan only, Dehumidification
Special functions Hi-Power, Eco, Timer (on/off), Auto clean, Auto restart, 3-minute protection function, Pre-heating, Auto defrost
Airflow direction control Vertical (FIX and SWING) and manual lateral
Remote control Infrared, LCD display, brightness setting (4 levels: d0 to d3), code A/B selection
Outdoor operating conditions Heating: -15°C to 24°C; Cooling/Dehumidification: -15°C to 46°C
Indoor operating conditions Heating: <28°C; Cooling: 21°C to 32°C; Dehumidification: 17°C to 32°C
Regular maintenance Clean air filters every 2 weeks; clean indoor unit with a damp cloth (no solvents)
Safety function 3-minute protection (prevents immediate restart), built-in circuit breaker

Frequently Asked Questions - SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E - SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E - RAS-B10UFV-E1 - RAS-B13UFV-E1 - RAS-B18UFV-E1 TOSHIBA

How to clean the air conditioner filters?
Open the air intake grille, remove the filters, vacuum them or wash them in warm soapy water, let them dry completely then reinstall them. Do not use benzene, thinner or abrasive products.
How to adjust the brightness of the remote control display?
Press and hold the FAN button for 3 seconds until the display shows 'd0', 'd1', 'd2' or 'd3'. Press the temperature buttons to increase or decrease the brightness levels: d3 = 100%, d2 = 50%, d1 = 50% without operation light, d0 = all lights off.
What to do if the remote control does not work?
First check the battery status (AAA type). If they are flat, you can use the temporary operation by pressing the RESET button on the indoor unit. Make sure the remote control is pointed at the receiver and there are no obstacles.
How to use the timer to turn off the unit?
When the air conditioner is running, press OFF to access the shutdown setting. Use the temperature buttons (or TRIE) to select a duration from 0.5 to 12 hours. Press OFF again to activate the timer. To cancel it, press OFF once more.
The air conditioner does not cool enough, what to check?
Check that the filters are not clogged, that the set temperature is lower than the room temperature (minimum 17°C in cooling), that windows and doors are closed, that the outdoor unit is not obstructed, and that the mode is not set to FAN or DEHUMIDIFICATION.
Can I use the heating in very cold weather?
Yes, the unit operates in heating mode down to -15°C outdoors. If the outdoor temperature is lower, it is recommended to use an auxiliary heater. The heating capacity decreases as temperatures drop.
How to change the batteries of the remote control?
Remove the battery compartment cover at the back of the remote control. Insert two new AAA batteries following the polarities (+ and -). Replace the cover. If necessary, reset the remote control by removing and reinserting the batteries.
How to reset the remote control (code A/B)?
Press the RESET button on the indoor unit to start the air conditioner. Point the remote control, hold CHECK with a pen until '00' appears, then without releasing CHECK, press MODE until 'B' appears. Release to memorize the remote control B. To return to A, repeat the operation.
What is the auto clean function?
This function prevents bad odors by drying residual moisture. In COOL or DEHUMIDIFICATION mode, press the dedicated button: the fan continues to run for 30 minutes after the compressor stops. To stop immediately, press twice more within 30 seconds.
Why are there cracking noises during operation?
These noises are normal and come from the expansion or contraction of the plastic materials of the indoor unit due to temperature changes. No intervention is necessary.

User questions about SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E - SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E - RAS-B10UFV-E1 - RAS-B13UFV-E1 - RAS-B18UFV-E1 TOSHIBA

1 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

How to adjust the air flow direction on a TOSHIBA air conditioning unit to avoid a 45-degree angle downwards?
Frequently Asked Questions - 24/02/2026
Response Notice-Facile

To adjust the air flow direction of your TOSHIBA air conditioning unit (models Suzuli/Suzumi RAS-B18N3KV2-E, RAS-B22N3KV2-E, RAS-B10UFV-E1, RAS-B13UFV-E1, RAS-B18UFV-E1) and prevent the louver from blowing systematically at a 45-degree angle downwards, you have two specific controls on the remote control.

Vertical adjustment (automatic): The SWING button (button 6 on your remote control) allows you to control the automatic swinging of the air blowing louver. Press this button once to set the louver to automatic sweep mode, which makes it cover all angles from top to bottom. Press again to stop the sweep.

Vertical locking at a specific angle: To fix the blowing louver in a particular position and avoid the 45-degree angle downwards, use the FIX button (button 5 on your remote control). Press this button to lock the louver in the desired vertical direction. If the louver is currently at 45 degrees and this is not your preference, you can first use the SWING button to sweep it until you find the ideal angle, then press FIX to lock it in that position.

Horizontal adjustment (sideways): The sideways (left-right) adjustment of the louver must be done manually. You can slightly adjust the slats by hand in the desired direction. Important: do not move the blowing louver manually in the vertical direction, use the SWING and FIX buttons for that to avoid damaging the mechanism.

Note: the blowing louver may automatically reposition itself according to the selected operating mode (cooling, heating, ventilation, etc.). If you notice that the louver returns to 45 degrees after a mode change, check your setting with the FIX button and restore it if necessary.

Respond (be the first)

Download the instructions for your Air-conditioner in PDF format for free! Find your manual SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E - SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E - RAS-B10UFV-E1 - RAS-B13UFV-E1 - RAS-B18UFV-E1 - TOSHIBA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E - SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E - RAS-B10UFV-E1 - RAS-B13UFV-E1 - RAS-B18UFV-E1 by TOSHIBA.

USER MANUAL SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E - SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E - RAS-B10UFV-E1 - RAS-B13UFV-E1 - RAS-B18UFV-E1 TOSHIBA

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

PRECAUTIONS FOR SAFETY

DANGER·Do not install, repair, open or remove the cover. It may expose you to dangerous voltages. Ask the dealer or the specialist to do this. ·Turning off the power supply will not prevent potential electric shock. ·The appliance shall be installed in accordance with national wiring regulation. ·Means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring.
WARNING·Do not expose your body directly to cool air for a long time. ·Do not insert your finger or any article into the air inlet/outlet. ·When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect the power supply or turn off the breaker. ·This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. ·Children should be supervised to ensure that they do not play with the appliance. ·Do not use any refrigerant different from the one specified for complement or replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body.
CAUTION·Do not wash the unit with water. It may cause an electric shock. ·Do not use this air conditioner for other purposes such as preserving food, breeding animal, etc. ·Do not step or put anything on the indoor/outdoor unit. It may cause an injury or damage the unit. ·Do not touch aluminium fin because it may cause an injury. ·Before cleaning the unit, turn off the main switch or the circuit breaker. ·When the unit won't be used for a long time, turn off the main switch or the circuit breaker. ·It is recommended that maintenance be performed by a specialist when the unit has been operated for a long time. ·The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.

1 INDOOR UNIT DISPLAY

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - INDOOR UNIT DISPLAY - 1

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - INDOOR UNIT DISPLAY - 2

① TIMER (White)
② OPERATION (White)

  • Display brightness can be adjusted, follow procedure on ⑪.

2 PREPARATION BEFORE USE

Preparing Filters

  1. Open the air inlet grille and remove the air filters.
  2. Attach the filters. (see detail in the accessory sheet)

Loading Batteries (when use wireless operation.)

  1. Remove the slide cover.
  2. Insert 2 new batteries (AAA type) following the (+) and (-) positions.

Remote Control Reset

  1. Remove the batteries.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Remote Control Reset - 1

  1. Insert the batteries.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Remote Control Reset - 2

3

AIRFLOW DIRECTION

1Press FIX: Move the louver in the desired vertical direction.
2Press SWING: Swing the air automatically and press again to stop.
3For horizontal direction, adjust manually.

Note:

  • Do not move the louver manually by others.
  • The louver may automation positioning by some operation mode.

4

REMOTE CONTROL

① Infrared signal emitter
(2) Start/Stop button
③ Mode select button (MODE)
(4) Temperature button (TEMP)
(5) Fan speed button (FAN)
⑥ Swing louver button (SWING)
⑦ Set louver button (FIX)
⑧ Off timer button (OFF)
9 High power button (Hi-POWER)
Economy button (ECO)
11 Clear button (CLEAR)
12 Check button (CHECK)

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - REMOTE CONTROL - 1

5

AUTOMATIC OPERATION

To automatically select cooling, heating, or fan only operation

  1. Press MODE : Select A.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - AUTOMATIC OPERATION - 1

: Set the desired temperature.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - AUTOMATIC OPERATION - 2

: Select AUTO, LOW, LOW+, MED, HIGH

6

For dehumidification, a moderate cooling performance is controlled automatically.

  1. Press MODE : Select Dry

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - 6 - 1

: Set the desired temperature.

8

Hi-POWER OPERATION

To automatically control room temperature and airflow for faster cooling or heating operation (except in DRY and FAN ONLY mode)

Press HPOWER : Start and stop the operation.

To automatically control room to save energy (except in DRY and FAN ONLY mode)

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Hi-POWER OPERATION - 1

: Start and stop the operation.

Note: Cooling operation; the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation the set temperature will decrease.

10 TIMER OPERATION

Set the timer when the air conditioner is operating.

Setting the OFF timer
1Press ON/OFF for enter OFF timer setting.
2Press TEMP for select desired OFF timer. (0.5 - 12 hrs)
3Press OFF for set OFF timer.
4Press OFF again for cancel OFF timer.

11 DISPLAY LAMP BRIGHTNESS ADJUSTMENT

To decrease the display lamp brightness or turn it off.

  1. Press and hold FAN for 3 seconds until brightness level (d0, d1, d2 or d3) is shown on remote control LCD then release the button.
  2. Press ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑↑
Remote control LCDOperation displayBrightness
d3Lamp illuminates full brightness.100%
d2Lamp illuminates 50% brightness.50%
d1Lamp illuminates 50% brightness and the operation lamp is turned off.50%
d0All lamps are turned off.All turned off
  • In the examples of d and d , the lamp illuminates for 5 seconds before going off.

12 TEMPORARY OPERATION

In case of the misplaced or discharged remote control

  • Pressing the RESET button, the unit can start or stop without using the remote control.
    Operation mode is set on AUTOMATIC operation, preset temperature is 24^ and fan operation is automatic speed.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - TEMPORARY OPERATION - 1

To automatically restart the air conditioner after the power failure (Power of the unit must be on.)

Setting

  1. Press and hold the RESET button on the indoor unit for 3 seconds to set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds)
  2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the operation. (3 beep sound but OPERATION lamp does not blink)
  3. In case of ON timer or OFF timer are set, AUTO START OPERATION does not activate.

To protect bad smell caused by the humidity in the indoor unit.

  1. If the button is pressed once during "Cool" or "Dry" mode, the fan will continue to run for other 30 minutes, then it will turn off automatically. This will reduce the moisture in the indoor unit.
  2. To stop the unit immediately, press the more 2 times within 30 seconds.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Setting - 1

Firstly, turn off the circuit breaker.

Indoor Unit and Remote Control

  • Clean the indoor unit and the remote control with a wet cloth when needed.
  • No benzine, thinner, polishing powder or chemically-treated duster.

Air filters

Clean every 2 weeks.

  1. Open the air inlet grille.
  2. Remove the air filters.
  3. Vacuum or wash and then dry them.
  4. Reinstall the air filters and close the air inlet grille.
  1. Three-minute protection feature: To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON.
  2. Preheating operation: Warm up the unit for 5 minutes before the heating operation starts.
  3. Warm air control: When the room temperature reaches the set temperature, the fan speed is automatically reduced and the outdoor unit will stop.
  4. Automatic defrosting: Fans will stop during defrost operation.
  5. Heating capacity: Heat is absorbed from outdoors and released into the room. When the outdoor temperature is too low, use another recommended heating apparatus in combination with the air conditioner.
  6. Consideration for accumulated snow: Select the position for outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris.
  7. Some minor cracking sound may occur when unit operating. This is normal because the cracking sound may be caused by expansion/ contraction of plastic. Note: Item 2 to 6 for Heating model

Air conditioner operating conditions

Temp. OperationOutdoor TemperatureRoom Temperature
Heating-15°C ~ 24°CLess than 28°C
Cooling-15°C ~ 46°C21°C ~ 32°C
Dry-15°C ~ 46°C17°C ~ 32°C

17 TROUBLESHOOTING (CHECK POINT)

The unit does not operate.Cooling or Heating is abnormally low.
· The power main switch is turned off. · The circuit breaker is activated to cut off the power supply. · Stoppage of electric current · ON timer is set.· The filters are blocked with dust. · The temperature has been set improperly. · The windows or doors are opened. · The air inlet or outlet of the outdoor unit is blocked. · The fan speed is too low. · The operation mode is FAN or DRY.

18 REMOTE CONTROL A-B SELECTION

To separate using of remote control for each indoor unit in case of 2 air conditioner are installed nearly.

Remote Control B Setup.

  1. Press RESET button on the indoor unit to turn the air conditioner ON.
  2. Point the remote control at the indoor unit.
  3. Push and hold check button on the Remote Control by the tip of the pencil. "00" will be shown on the display. (Picture ①)

  4. Press MODE during pushing CHECK. "B" will show on the display and "00" will disappear and the air conditioner will turn OFF. The Remote Control B is memorized. (Picture ②)

Note: 1. Repeat above step to reset Remote Control to be A.

  1. Remote Control A has not "A" display.
  2. Default setting of Remote Control from factory is A.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Remote Control B Setup. - 1

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Remote Control B Setup. - 2
2

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

ESPANOL

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

FRANÇAIS

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

ITALIANO

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

PRECAUZIONI PER LA SICUREZZA

1 DISPLAY DELL'UNITÀ INTERNA

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - DISPLAY DELL'UNITÀ INTERNA - 1

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - DISPLAY DELL'UNITÀ INTERNA - 2

① TIMER (Bianco)
② OPERATION (Bianco)

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

DEUTSCH

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

PORTUGUES

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

PRECAUÇÖES RELATIVAS A SEGURANÇA

Clean every 2 weeks.

  1. Open the air inlet grille.
  2. Remover os filtros de ar.
  3. Vacuum or wash and then dry them.
  4. Reinstale os filtros de ar e feche a grelha de admissao.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - PRECAUÇÖES RELATIVAS A SEGURANÇA - 1

OPERACAO E DESEMPENHO

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

POLSKI

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

ZASADY BEZPIECZENSTWA

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

ČESKY

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

BEZPEČNOSTNI OPATRENI

11 UPRAVA JASU KONTROLKY DISPLEJE

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

HRVATSKI

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

MJERE SIGURNOSTI

!OPASNOST·Nemojte ugrădivati, popravljati, otvarati niti skidatiPoklipac. Unutra se nalaze elementi pod visokimnaponom. Obavljanje toga prepustite prodavaču ili serviseru. ·Isključivanje mrežnog napona neće spijěčiti mogućnostnastanka elektrićnog udara. ·Urežaj mora biti ugradenu u skladu s nacionalnimstandarima ožičanja. ·Mogućnost isključivanja s izvora napajanja, s razmakomizme du kontakata od rajmanje 3 mm na svim polovima, mora biti ugrădenu u fiksni sustav ožičanja.
UPOZORENJE·Nemojte svojne tijelo dulje vrijeme izravno izlagatihladnome zraku. ·Nemojte gurati prste ni druge predmete u otvore za ulaz i izlaz zraka. ·U slučaju nastanka neuobičajenih pojava (mirisa zagorjelosti i sl.), isključite klimatski urežaj i iskopćajte mrežni naponi ili zvizadne osigurac. ·Urežajem ne smiju rukovati osobe (ukljućujić dijecu)smanjenih tjelesnih, osjetilinih ili mentalinh spoobnosti, te osobe bez izkustva i znanja, osim ako nisu pod nadzorom ili su dobili naputke od osobe koja je odgovorna za njihovu sigurnost. ·Djeca moraju biti pod nadzorom kako se ne bi igrala urežajem. ·Nemojte koristiti ni Jedno drugo rashladno sredstvoosim specificiranog za dopunjavanje ili zamjenu. U suprotnom,MZE go stvoriti nenormalno jak tlak u krugu rashlašivanja, štoMZE go prouzročiti kvar ili eksploziju proizvoda ili tjelesnu ozljedu.
!OPREZ·Urežaj ne perite vodom. To bi moglo izazvati elektrICI udar. ·Klimatski urežaj nemojte koristiti u svrhe za koje nije namijenjen, primjerice za zamrzavanje hrane, uzgajanjeŽivotinja i sl. ·Nemojte gaziti niti bilo Što stavljati na unutarnju i vanjsku jodicinicu. ToMZE go prouzročiti ozljede i osetiti urežaj. ·Nemojte dotici aluminjsko rebro jer seMZe gozljediti. ·PrijeŽišćenja urežaja, isključite glavni prekidač ili izvaditeosigurač. ·Ako urežaj dulje vrijeme nece biti korišten, isključiteglavni prekidač ili izvaditeosigurač. ·U slučaju dugotrajnog rada preporučuje se da oderžavanje provodi ovlăstena osoba. ·Proizvodačne preuzima nikakvu odgovornost za oshtećenja uzrokovana nepoštivanjem opisa u ovom priručniku.

1 PRIKAZ UNUTARNJE JEDINICE

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - PRIKAZ UNUTARNJE JEDINICE - 1

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - PRIKAZ UNUTARNJE JEDINICE - 2

① TIMER (Bijela)
② OPERATION (Bijela)

  • Svjetlina zaslona moze se podesiti, slijedite postupak na ⑪.

2 PRIJE UPORABE

Priprema filtrara

  1. Otvorite rešetku usisa zraka i izvadite filtrte za zrak.
  2. Ugradite filtr. (pogledajte detailj na listu s dodatnim componentama)

Stavljanje baterija (in cazul utilizarii fara fir.)

  1. Scoateti capacul culisant.
  2. Stavite 2 nove baterjie velicine AAA, pazeci pritom na isprawan položaj polova (+) i(-).

Resetiranje daljinskog upravljača

  1. Uklonite bateriju.
  2. Pritisnite tipku
  3. Umetnite bateriju.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Resetiranje daljinskog upravljača - 1

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

MAGYAR

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

BIZTONSAGI ELOIRASOK

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

NEDERLANDS

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

VEILIGHEIDSVOORZORGEN

1 DISPLAY BINNENMODULE

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - DISPLAY BINNENMODULE - 1

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - DISPLAY BINNENMODULE - 2

① TIMER (Witte)
② OPERATION (Witte)

6 KOLLING / VENWARM VENTILATIE WERKING

  1. Druk op MODE : Kies Koeling , Verwarming , of Ventilate

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - KOLLING / VENWARM VENTILATIE WERKING - 1

Koeling: Min. 17^ , Verwarming: Max. 30^ , Ventilatie: Geen temperatuurindicatie

3.Druk op FAN:Kies AUTO,LOWLOW+MED MED+ of HIGH

7 DROGE WERKING

8 HOOGVERMOGENSWERKING

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

EΛΛHNIKA

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

PPOΦYΛAΞEΙΣ AΣΦΑΛΕΙΑΣ

KINΔYNOSMny tototheite, mny etiokeuaçête, mny avoiyête kai mny aapiaéite to kαλuμa. Evéxetai va ekteθeite σe etikivoucε στáθεçá tácnq. Aviipooatne iα avitipooatne iα Ε έ katiov o Eikiejévo texvićo va to kávei. H attevytoianŋ nts ouakeuç̍δev oac tripoataeuei attó πθaov kiivuo πókληanŋ nækptopllnξiac. H totoθetηη nts ouakeuç̍δθa πpêtei va yivei αúφuva μe tov ebvičkavoviau ou aρoá tri kαλwbiωeic. θa πpêtei va πapexetai otny móviŋ kαwbiωη ntpotoc attouuvvctne otn oyn paxoh, μe diauxpiaó uov etapwν touλáxiatov katá 3 mm, αe álouc touc πóluoc.
ΠPOEIIΔONIOIHΣMny ektiheate atnebeiaç σtov kvuo aépa eπi μeyalace xovikéς trepiööuc. Mny ióáyete ta δáxtulá oac n àvtikejéva otny eioayuyñ/égo do Tou aépa. Otau utápxouv μu quiaoloyiké evdeiéic (ooum kauévou k.ltt.) di kαopte tri λεitoupyia vou klaatiatikou kai attouvduéte o to ató n'tpíca n katebäote nγo aφáleia. H ouakeun autn dév πoopiciéta iya xρηon ató atóuja (oumtpieiauavépuévuv vou tān viðüv) μe peiwéveç quaikeç, aiəntnpiénc n tveupatikié κavotnε. h élambdaeiny uetaipiaic kai yvwaewev, ektcós kauéβipokovtai utó eπiβaevn n kαθoδηηon xεtiki μe t n xρηon nts ouakeun cato atómo uθtevuv yia nγo aφáleia touc. Taa triadia pétéi va emiβaetovai wote va εgαφαλicetai otd eviàouv μe tn ouakeun. Tia ouiμlánpwon n avitkatáotaaon tu υukniču, μn xρηauiotouie n katioia diapopetikó ató to kαθopiajévo. Δiapopetiká, aouviθiota uwnl nieon μtpei va tapaixθei otv Kuklo υuεns, yevovc nts μtopei va obnynei oe aotoxia n ékpnjn tau piovdvtos n Εe tpaupatiauó.
ΠPOΦYΛAΕΗMny πλevet e Tny mcvadα μe vepó. Mtpoei va tpokληθei ηλeκtpotlánjia. Mny xρηauiotnoite to klaiatiotko autó yia állassouc σοτοιος, απtως n αυνtɪŋpən τropijuv, n ektpoŋζωv κλtt. Na μη πatáte kai va μnytotofte iTeTota etánuw atónu eαuopeiikn/égwtepiikn módvāa. Mtpoei va tpaunatiete iγ va tpokaláétezζnaia ot n vodδa. Mny akoumita tny tpepiδa alouviou kαθως μtpei va tpokληθei tpaunatipóuc. Pivovn kαθaipiaó tns mcvadα, kλeiate to γevikó biakótttn n'tov aαφαleidbiakótttn. Otaiv n mcvadα δev tpokéiata va xρηauiotnoiθei yia μeγaλn xpvokni teripiodo, kλeiate to yevikó biaikótttn n'tov aαφαleidbiakótttn. Σuviotatai va yivetai n ouvtɪŋpən ató to texvićo òatv n oukeuēn éχi λεitoupye iεnti μaikpov. O kataeuaattc jev θa avaiäβe kajia eudūvn yia ζjula toun μtpei va tpokληθi λayw μn tɪŋpən s w πepiypawv oe auto to éyχipioio.

1 ENAEIEEIEZ EQUTEPIKHZ MONADAA

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - ENAEIEEIEZ EQUTEPIKHZ MONADAA - 1

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - ENAEIEEIEZ EQUTEPIKHZ MONADAA - 2

① Auxvia TIMER (Aotnpo)
② Auxvia OPERATION (Aotipo)

H. qneitovrtnaTnOboVns mptoe va Tpooapnootei, aokaouBHTe Tn diaikaaia stn vEvnto 1

2)ΠPOETIMAZIA ΠPIN ANO TH XPHZH

Ipoetoiagia twv qtpw

  1. Avoliet yjplia eiooou tou aepa kai apaipote ta qilapa aepa.
  2. ToTERTOTeTa APTaP. (Bλ. AETITIOpeEIEc OTo QAALO aEGoUOd)

Totothettony nvtatapiwv (kata tn xipn oe aoupatn aeitoupyia).

  1. AφaipeoTe To kaluμa Tns μTataiac.
  2. Tontotertjote 2 vecs μatapapié (tou AAA), μισμωνα με τις θεοεις (+) και (-).

Etnavopopa tnaexepiotnpiou

  1. AΦaipεοτην μπιαρία.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Etnavopopa tnaexepiotnpiou - 1

  1. TOnToTeTnToTe Tny mntatapia.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Etnavopopa tnaexepiotnpiou - 2

3 KATEYOYNsH POH

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

SUOMI

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

VAROTOIMENPITEET

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

SIKKERHEDSFORBEHOLD

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

ROMÁNA

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

MÁSURI DE SIGURANTA

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

MEPKN 3A BE3ONACHOCT

!ОПАССТОВ·He монтураите,_nonраваяITE,OTвараяITEил CBальаяTE КANAKA.Можete ду се ИЗПОЛКITE на опасно ВИССКИ нарржени.3da ду habравITE_TOBA,обрhoeTe ce КБМ Ваши дулр иду сиелочиNT. ·Изклічыанeto на зхаранваенeto Нмма ду пedingотьрати notehuahmuaHToTOKOBU YAdprn. ·Уретдт Trябба ду се Исталп rap вCBotEVCTBVE c мec'thne Nahe'db63a e neEkTPrUnCeKte INcTalaamn. ·CpeDCTBa 3a ИЗПLOUVAHE Na 3axpaHbaHETO c pадделян на кontakTiTe Na BCvchyn ПОнсу Na NOhe 3 MM TrябБа ДдБдат BrPraldeHbBФиКсрAnATA eNeEkTPrUnCeK нсHTalaamn.
!ОПЕДΥРЕЖДЕМЕ·He Излагайte ДИЕKTTHO TЯЮТо Си рindьлжинелно Вразе Na Stydн БИЗДХ. ·He Пьхайte Рьсту си Или Дугун пedingmetи ВьВ ВхODнHy/NIXKOДнHy OTBOP 3a BvIaDyX. ·Ако усете Н stoу Нередно (МирIMma Na ИЗROPENo I T.H.),спerte КлIMATNka,ИЗПLOЧeze 3axpaHbaHETO n ИЗПLOCHYпспeКьСВAZa. ·Tozhi урeded He e пedingиз havен 3a ИзползВане OT пima (BИКИСТENTOДELA)с hapucheyи ФичИССКИ,сэнори ил УмТВЕни CnOCOБСНТи Niz Be3 OпITи ИпЗанЯ, OCBEN Akо п dire ИЗПОЛЗВанeto My CA NaHbIOnDAВAHIn пilny UYTBaHOn OT liNe,OTROBOPHO 3a TЯХ纳ATA 6EZonTACHST. ·He noЗвOLБаяte Na Deцета Ду си irpopaTсуда. ·He Излогьаяte XlaДINENH areHT,parlNiChen ot nocochena,3a DoINIBaNEипodмян.В ростaven Cluyay'mma ONaCHOST OT Bv3HNIKBaHBe Na HeeCECTBVEH ВИССКОн HANIRGAE Na OXANJDAUSSI UNICKBy,Коeto моJODE da doBode Do nobpeDa Ип exCpIOnO3ry Na npodykTu Ип TeLECHO HaparHbAbe.
BHIMAHIME·He мійte ур dedа вBoDA.Можete ду пedingизmate eIeKTPrUnCeKs Ydap. ·He Излогьаяte ур dedа 3a Дуг'tи сelу,КATO NaHp. KOHCEBPINARe Na xPRAHa,OTTRKJDAne Na JxHBOITNи T.N. ·He пotingудду Ипю BvPxy BvTpeuHata/вьншнata чAst.Тoba може DA naparany Иповdedу ур deda. ·He dokosваяte anummHneBOTO pebpo,Ть кATO моJOFEte da CE HabapAHite. ·П配电дду zanOчнete Ду чИТETе ур deda,ИЗПLOCHYe КLOчa Na ZaxpaHbaHETO ИпВАТМУТИЗУ ПЕКьСВЧ. ·Ако Нмма Na ИЗПОЛЗВATE yр deda 3a No-Дыт bпepinoD ot BpeMe,ИЗПLOCHYе KLOчa Na ZaxpaHbaHETO Ип ВАТМУТИЗУ ПЕКьСВЧ. ·ПpenOpьчENTнHa e PodpьЖka OT cseMuAlnICT,Ако ур deda tБин Излогьанвпрдьлжittелно Вьам. ·ПрOMSIBDITeRун Te NOEMA OTROBOPHOCST 3a ZeTin, причнени NT HecePAsBaHETO Na ONMCAHIneto B TOBA рьБКOBODCTBO.

1 DINGJIEN HA BbTPEHATA YACT

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - DINGJIEN HA BbTPEHATA YACT - 1

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - DINGJIEN HA BbTPEHATA YACT - 2
① TIMER (BnTe)
(2) OPERATION (Bute)

JRPCKCTA Na DCNPNNE MOKe DA ce perynnpa, cneBaiTe npoueypata Na CTP. ⑪

2 IODTOTOBKA IPEDN N3IOJ3BAHE

IodrotobKaHaΦnITpnte

1.OTbopete peseiiketaka HuaBXDnHaOTOBpa3 bB3dxHcBANETe B3duYinHteINPNTR.
2.3Aazahef Chnfptnre.(3a noBcepe npDoo6HOH BIX CNbCbKa c 0eCoaoepHTe)

3aepxkanhe Ha 6aetepnnte (npra pa6oBa T 6e3xKuHn peKHM.

  1. Otctpanhe nIb3raoTo kanaue.
  2. Noctabete 2 NOBn Batepnn (TIN AAA), 2nbaaikn (+) n (-) noctocak.

Pecaptnpahe Na nctaHmOHnHO npabpne

  1. CbaJIeTe 6aTePnIraTa.
  2. Hatnchete
  3. NocTabete 6aTepyra.

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Pecaptnpahe Na nctaHmOHnHO npabpne - 1

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - Pecaptnpahe Na nctaHmOHnHO npabpne - 2

3 IIOCOKA HA Bb3dUshnI NOTOK

1Нат生态系统 FIX: Пrecognite Вер Tinaлине Вентлидан OTьорь в желанату ot Boc noca.
2Hашиrese SWING: завырты авTomатichу въдуна. Нат生态系统 OTново, за за спөге.
3Насточе рьчнохоризотална nosoka.

3a6eJexka:

He ce onntbaite pbyo da npemecBaTe BEHTnlaucnoHHra OTBOP.
BENTHINAQUHNIATOBPMOKDEaCtPO3MUNHOHPABOMATUHO 3a npctdEpTPEXHIMaPA60TA.

4ФУHKUIMHANДИCTAHCUHOHHOTO YIPABJIEHME

① N3TOUHnKa Ha INHpauepeBc nRHa
② BytOH 3a nycKaHe/cnnpaHe
③ BytOH 3a n36op Ha peXIM (MODE)
④ Bytoh 3a TemnepaTypaTa (TEMP)
(5) ByToH 3a CkOpocTtHa HbEHTnJaTopa (FAN)
⑥ BytOH 3a JIOJIeHe Ha XaIy3nTe (SWING)
⑦ BytoN 3a Nahtroika Na BENTnlaMOnHHNAOTBOP (FIX
⑧ ByToH Ha TaIIMepa 3a N3KJIIOUBAHe (OFF)
⑨ ByToH 3a BnCoka MoUHOCr (Hi-POwER)
10 Bytoh 3a eheprocnctraBahe (ECO)
⑪ ByToH 3a I3UHCTBaHc (CLEAR)
(12) ByToH 3a KOHTpOJ (CHECK)

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - 4ФУHKUIMHANДИCTAHCUHOHHOTO YIPABJIEHME - 1

5 ABTOMATNUEH PAXIM HA PABOTA

3a da n36epete abTomatnH0 oxJaxdahe, oTOnJIeHne IIN BEHTUNIPAhe

  1. Hatnche T MODE : n36peTe A.
  2. HatncheTe TUR: HactpoIte XeJahata TemnepaIpya.
  3. Hanche TAN: N36epete AUTO, LOW-, LOW+, MED+, MED+ , nii HIGH

6 PEXIM HA OXJIAXDAHE / OTONJIEHNE / PEXIM BEHTNJIPAHE

  1. Hattichete MODE : 366epete Cool , Heat , und Fan only
    2.Hatnchete TEM

OxnaxJaHe: MIn. 17^ Heating: MaKc 30^ Fan Only: HMaMnDnKaZna 3a TempepaTypara
3. HancheTe FAN :Изберete AUTO, LOW-, LOW+MED+, MED+ , UNI HIGH

7 PEXKUM HA MEKO I3CYUABAHE

3a 13cauabahe,peKIMbT hA yMepeHO OXnaJdahe CE KOHTponipa ABOTMATUHO.

  1. Hatuchete MODE : 136ebepete Dry
  2. Hatnchete : Nahtpoite XeJanaHata Temnepatypa.

8 PEXUM Hi-POWER

3aДа KOHTPONIPATE ABTOMATMNUO CTHINATA TEMNEPATyPA N Bb3DuHINNA NOTOK 3a NO-bp30 OXnLaKdAne HIN 3aTOnPiNe (C INsKnIOUHeHne Ha pexMMITE DRY n FAN ONLY)

HATNCHE TPOWES:Пусяа и сира ржима.

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

EESTI

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

ETTEVAATUSABINÖUD

17 VEAD (CHECK POINT)

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

LATVISKI

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

PROFILAKTISKIE DROŠIBAS PASAKUMI

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

SLOVENCINA

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

11) UPRAVA JASU KONTROLKY DISPLEJA

17 RIESENIE PROBLEMOV (KONTROLNY BOD)

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

SLOVENŠČINA

VARNOSTNA OPOZORILA

Izberite AUTO, LOW-, LOW+, MED

MED+ ,ali HIGH

6 HLAJENJE /OGREVANJE /DELOVANJE SAMO VENTILATORJA

  1. Pritisnite na

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - HLAJENJE /OGREVANJE /DELOVANJE SAMO VENTILATORJA - 1

: Izberite Cool Heat Ali Fan only

  1. Pritisnite na

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - HLAJENJE /OGREVANJE /DELOVANJE SAMO VENTILATORJA - 2

Nastavite zeeleno temperaturo.

Cooling: Min. 17^ , Heating: Max. 30^ , Fan Only:

Brez temperaturne oznake.

  1. Pritispite na

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - HLAJENJE /OGREVANJE /DELOVANJE SAMO VENTILATORJA - 3

Izberite AUTO. LOWLOW+ MED

MED+ ,ali HIGH

7 SUSENJE

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

TOSHIBA

OWNER'S MANUAL

TOSHIBA SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E  -  SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E -  RAS-B10UFV-E1 -  RAS-B13UFV-E1 -  RAS-B18UFV-E1 - OWNER'S MANUAL - 1

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-07, 10, 13BKV-E

Outdoor unit

RAS-07, 10, 13BAV-E

LIETUVI

SAUGOS PRIEMONÉS

Information according to EMC Directive 2004/108/EC
(Name of the manufacturer)TOSHIBA CARRIER (THAILAND) CO., LTD.
(Address, city, country)144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANG, PATHUMTHANI 12000, THAILAND.
(Name of the Importer/Distributor in EU)TOSHIBA CARRIER UK LTD.
(Address, city, country)Porsham Close, Belliver Industrial Estate, PLYMOUTH, Devon, PL6 7DB. United Kingdom

TOSHIBA

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : TOSHIBA

Model : SUZULI RAS-B18N3KV2-E + RAS-18N3AV2-E - SUZUMI RAS-B22N3KV2-E + RAS-22N3AV2-E - RAS-B10UFV-E1 - RAS-B13UFV-E1 - RAS-B18UFV-E1

Category : Air-conditioner