USER MANUAL DCE088R DEWALT
Safety
Product Overview
- Batteries and Power
Operation
Accuracy Check and Calibration
- Specifications
User Safety

WARNING:
Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire and/or serious personal injury.

WARNING:
Laser Radiation Exposure. Do not disassemble or modify the laser level. There are no user serviceable parts inside. Serious eye injury could result.

WARNING:
Hazardous Radiation. Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

CAUTION:
LASER RADIATION -DO NOT STARE INTO THE LASER BEAM.Class 2 Laser Product.
- The label on your tool may include the following symbols.
V volts
mW milliwatts
Ah Ampere Hours

laser warning symbol
nm wavelength in nanometers
2.Class 2 Laser

Do not stare into the laser beam.
Warning Labels
For your convenience and safety, the following labels are on your laser.


WARNING: To reduce the risk of injury, user must read instruction manual.

WARNING: LASER RADIATION. DO NOT STARE INTO BEAM. Class 2 Laser Product


- Do not operate the laser in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Power tools create sparks which may ignite the dust or fumes.
- Use the laser only with the specifically designated batteries. Use of any other batteries may create a risk of fire.
- Store idle laser out of reach of children and other untrained persons. Lasers are dangerous in the hands of untrained users.
- Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one laser, may create a risk of injury when used on another laser.
- Tool service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel may result in injury. To locate your nearest DeWALT service center go to http://www.dewalt.com on the Internet.
- Do not use optical tools such as a telescope or transit to view the laser beam. Serious eye injury could result.
- Do not place the laser in a position which may cause anyone to intentionally or unintentionally stare into the laser beam. Serious eye injury could result.
- Turn the laser off when it is not in use. Leaving the laser on increases the risk of staring into the laser beam.
- Do not disassemble the laser tool. There are no user serviceable parts inside.
- Do not modify the laser in any way. Modifying the tool may result in Hazardous Laser Radiation Exposure.
-
Do not operate the laser around children or allow children to operate the laser. Serious eye injury may result.
-
Do not remove or deface warning labels. Removing labels increases the risk of exposure to radiation.
- Position the laser securely on a level surface. Damage to the laser or serious injury could result if the laser falls
Laser Information
- The DCE088R and DCE088G Laser Levels are Class 2 laser products.
- The DCE088R and DCE088G lasers are self-leveling laser tools that can be used inside and outside for horizontal (level), vertical and plumb alignment projects.

WARNING:
Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire and/or serious personal injury.
Work Area
- Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
- Do not operate laser tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
- Keep bystanders, children, and visitors away while operating a laser tool. Distractions can cause you to lose control
Electrical Safety
- Use battery operated tool only with the specifically designed batteries. Use of any other batteries may create a risk of fire.
Product Overview

WARNING:
Never modify the tool or any part of it. Damage to the laser or personal injury could result.
Figure 3 - Battery Interface A
Figure 2 - Pendulum Lock
Figure 2 - Keypad
Figure 5B - ON/OFF button: horizontal laser line D
Figure 5B - ON/OFF button: vertical laser line
Figure 5B - Battery Meter F
Figure 3 - Magnetic pivot bracket
Figure 3 - Keyhole slot H
Figure 5A - Tripod thread fitting (1/4 - 20" & 5/8-11)
Figure 5A - Ceiling Mount
Figure 5A - Clamp
Figure 5A - Screw Hole M
Batteries and Power
- This tool is powered by the following DeWALT 10.8V Battery packs: DCB120, DCB127 or may also be powered using the DEWALT AA Starter pack which can carry 4 × AA batteries. Note: The AA starter pack is recommended only for use with the red laser
Battery Installation / Removal
(See figure ③)
Using the AA Starter Pack:

CAUTION:
The AA starter pack is designed specifically for use only with the DeWALT 10.8V compatible laser products and cannot be used with any other tools Do not attempt to modify the product.
To install batteries:
- Lift up the battery compartment cover as shown in Figure 4.
- Insert four fresh AA batteries in the compartment, placing the batteries according to (+) and (-) on the inside of the compartment.
- Install the AA starter Battery pack as shown in Figure
Using the 10.8V DEWALT Rechargeable Pack:
Install the 10.8V Battery pack as shown in Figure ③.

WARNING:
Batteries can explode, or leak, and can cause injury or fire. To reduce this risk carefully follow all
- Carefully follow all instructions and warnings on the battery instructions on the label and package and accompanying Battery Safety Leaflet.
Always insert batteries correctly with regard to polarity (+ and -) , marked on the battery and the equipment. - Do not short battery terminals.
- Do not charge disposable batteries.
- Do not mix old and new batteries. Replace all of them at the same time with new batteries of the same brand and type.
GB
DEWALT.
User Manual
- Remove dead batteries immediately and dispose of per local codes.
- Do not dispose of batteries in fire.
- Keep batteries out of reach of children.
- Remove batteries when the device is not in use
- Use only the charger specified for your rechargeable battery pack.
Personal Safety
- Stay alert, watch what you are doing and use common sense when operating a laser tool. Do not use tool while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating power tools may result in serious personal injury.
- Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control of the tool in unexpected situations.
- Use safety equipment. Always wear eye protection. Dust mask, non-skid safety shoes, hard hat, or hearing protection may be required for appropriate conditions.
Tool Use and Care
- Do not use tool if switch does not turn it on or off. Any tool that cannot be controlled with the switch is dangerous and must be repaired.
- Store idle tools out of reach of children and other untrained persons. Tools are dangerous in the hands of untrained users.
- Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one tool, may become hazardous when used on another tool.
Service
- Tool service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.
- When servicing a tool, use only identical replacement parts. Follow instructions in the Maintenance section of this manual. Use of unauthorized parts or failure to follow Maintenance Instructions may create a risk of electric shock or injury.
To locate your nearest DeWALT service center go to http://www.dewalt.com on the Internet.
Operating Tips
- Use only new, high-quality, name brand AA batteries or specified rechargeable DEWALT 10.8V Li-ion pack for best results.
- Ensure batteries are in good working condition. If the low battery red indicator light is flashing, the batteries need replacement.
To extend battery life, turn laser off when not working with the beam. - To ensure the accuracy of your work, check to make sure your laser is calibrated often. See Field Calibration Check.
- Before attempting to use the laser, make sure it is positioned securely, on a smooth, flat surface.
Always mark the center of the beam created by the laser. - Extreme temperature changes may cause movement of internal parts that can affect accuracy. Check your accuracy often while working. See Field Calibration Check.
- If the laser has been dropped, check to make sure your laser is still calibrated. See Field Calibration Check.
- Place the laser on a smooth, flat, stable surface that is level in both directions.
Low Battery Indication
The DCE088R and DCE088G lasers are equipped with a battery gauge as shown in Figure 5B. The battery gauge indicates remaining power with each LED representing 25% . The bottom LED will illuminate and blink indicating that the level is low (below 12.5% ) and the batteries need to be replaced. The laser may continue to operate for a short time while the batteries continue to drain, but the beam(s) will quickly dim. After fresh batteries are installed and the laser is turned on again, the laser beam(s) will return to full brightness and the battery indicator level will indicate full capacity. (A flashing laser beam is not caused by low batteries; see Out of Tilt Range Indicator.) If all 4 LED's on the battery meter LED's continuously flash this does not indicate a low battery; see "The Battery Meter LED's Flash" under Troubleshooting.
Operation
To Turn the Lasers On and Off
(See Figure ②, ⑤)
With the laser off, place it on a flat surface. This model has a pendulum locking switch B and a keypad C to activate the laser beams with two ON/OFF buttons; one for a horizontal laser line D and one for a vertical laser line E. Each laser line is powered on by moving the pendulum lock switch B to the
UNLOCKED/ON position and pressing the required ON/OFF button on the keypad. The laser lines can be powered one at a time or at the same time. Pressing the ON/OFF buttons again turns the laser lines off. The pendulum locking switch disables the lasers as well as locking the pendulum, and should always be placed in the LOCKED/OFF position when the laser is not in use. If the pendulum lock switch is not placed in the lock position all 4 LED's will continuously flash on the Battery Meter.
Using the Lasers
Out of LEVEL Range Indicator
The lasers are designed to self-level. If the laser has been tilted so much that it cannot self-level (>4^) , the laser beam will flash. There are two flashing sequences associated with the out of level condition: (i) between 4^ and 10^ the beams flash with a constant blink cycle; (ii) at angles greater than 10^ the beams flash with a three blink cycle. When the beams flash the laser is not level (or plumb) and should not be used for determining or marking level or plumb. Try repositioning the laser on a more level surface.
Using the Pivot Bracket (See figure 3)
The lasers have a magnetic pivot bracket ⑥ permanently attached to the units. This bracket allows the unit to be mounted to any upright surface made of steel or iron. Common examples of suitable surfaces include steel framing studs, steel door frames and structural steel beams. The bracket also has a keyhole slot ① allowing the unit to be hung from a nail or screw on any kind of surface. Position the laser and/or wall mount on a stable surface. Serious personal injury or damage to the laser may result if the laser falls.
Using the Laser with the CEILING Mount
(See Figure 5)
The laser ceiling mount (if included) offers more mounting options for the laser. The ceiling mount has a clamp at one end (K) which can be fixed to a wall angle for acoustic ceiling installation. At each end of the ceiling mount is a screw hole (M), allowing the ceiling mount to be attached to any surface with a nail or screw.
Once the ceiling mount is secured, its steel plate provides a surface to which the magnetic pivot bracket can be attached. The position of the laser can then be fine-tuned by sliding the magnetic pivot bracket up or down on the wall mount.
Using the Lasers with Accessories
The lasers are equipped with 1/4 - 20 and 5/8 -11 female threads on the bottom of the unit. This thread is to accommodate current or future DeWALT accessories. Only use DeWALT accessories specified for use with this product. Follow the directions included with the accessory.

CAUTION:
The use of any other accessory not recommended for use with this tool could be hazardous.
If you need any assistance in locating any accessory, please contact your nearest DeWALT service center or go to http:// www.dewalt.com on the Internet.
Leveling the Lasers
As long as the lasers are properly calibrated, the lasers are self-leveling. Each laser is calibrated at the factory to find level as long as it is positioned on a flat surface within ± 4^ of level. No manual adjustments must be made.
Maintenance
- To maintain the accuracy of your work, check the laser often to make sure it is properly calibrated. See Field Calibration Check.
- Calibration checks and other maintenance repairs may be performed by DeWALT service centers.
- When not in use, store the laser in the kit box provided. Do not store your laser at temperatures below -20^ ( 5^ ) or above 60^ ( 140^ ).
- Do not store your laser in the kit box if the laser is wet. The laser should be dried first with a soft dry cloth prior to storage.
Cleaning
Exterior plastic parts may be cleaned with a damp cloth. Although these parts are solvent resistant, NEVER use solvents. Use a soft, dry cloth to remove moisture from the tool before storage.
User Manual
Accuracy Check and Calibration
Checking Accuracy - Horizontal Beam, Scan Direction (See figure 6)
Checking the horizontal scan calibration of the laser requires two walls 30^ (9 m) apart. It is important to conduct a calibration check using a distance no shorter than the distance of the applications for which the tool will be used.
- Attach the laser to a wall using its pivot bracket. Make sure the laser is facing straight ahead.
- Turn on the laser's horizontal beam and pivot the laser approximately 45^ so that the right-most end of the laser line is striking the opposing wall at a distance of at least 30^ (9 m). Mark the center of the beam
- Pivot the laser approximately 30^ to bring the left-most end of the laser line around to the mark made in Step 2. Mark the center of the beam
- Measure the vertical distance between the marks.
- If the measurement is greater than the values shown below, the laser must be serviced at an authorized service center.
| Distance Between Walls Allowable Distance Between Marks |
| 9 m (30') 3.0 mm (1/3") |
| 12 m (40') 4.0 mm (5/32") |
| 15 m (50') 5.0 mm (7/32") |
Checking Accuracy - Horizontal Beam, Pitch Direction (See figure⑦)
Checking the horizontal pitch calibration of the laser requires a single wall at least 30^ (9 m) long. It is important to conduct a calibration check using a distance no shorter than the distance of the applications for which the tool will be used.
- Attach the laser to one end of a wall using its pivot bracket.
-
Turn on the laser's horizontal beam and pivot the laser toward the opposite end of the wall and approximately parallel to the adjacent wall.
-
Mark the center of the beam at two locations ①, ② at least 30^(9m) apart.
- Reposition the laser to the opposite end of the wall.
- Turn on the laser's horizontal beam and pivot the laser back toward the first end of the wall and approximately parallel to the adjacent wall.
- Adjust the height of the laser so that the center of the beam is aligned with the nearest mark .
- Mark the center of the beam ⑥ directly above or below the farthest mark C
8.Measure the distance between these two marks c,e. - If the measurement is greater than the values shown below, the laser must be serviced at an authorized service center.
Checking Accuracy -
Vertical Beam (See Figure 8)
Checking the vertical (plumb) calibration of the laser can be most accurately done when there is a substantial amount of vertical height available, ideally 30^ (9 m), with one person on the floor positioning the laser and another person near a ceiling to mark the position of the beam. It is important to conduct a calibration check using a distance no shorter than the distance of the applications for which the tool will be used.
- Start by marking a 5^ (1.5m) line on the floor.
- Turn on the laser's vertical beam and position the unit at one end of the line, facing the line.
- Adjust the unit so its beam is aligned and centered on the line on the floor.
- Mark the position of the laser beam on the ceiling ① .Mark the center of the laser beam directly over the midpoint of the line on the floor.
- Reposition the laser at the other end of the line on the floor. Adjust the unit once again so its beam is aligned and centered on the line on the floor.
- Mark the position of the laser beam on the ceiling g , directly beside the first mark f .
- Measure the distance between these two marks.
- If the measurement is greater than the values shown below, the laser must be serviced at an authorized service center.
| Distance Between Walls Allowable Distance Between Marks |
| 9 m (30') 6.0 mm (1/4") |
| 12 m (40') 8.0 mm (5'16") |
| 15 m (50') 10.0 mm (13/32") |
Troubleshooting The Laser Does Not Turn On
- Make sure AA batteries (when used) are installed correctly according to (+) and (-) on the inside of the battery door.
- Make sure the batteries or rechargeable pack are in proper working condition. If in doubt, try installing new batteries.
- Make sure that the battery contacts are clean and free of rust or corrosion. Be sure to keep the laser level dry and use only new, high-quality, name brand batteries to reduce the chance of battery leakage.
- If the laser unit is heated above 50^ ( 120^ ), the unit will not turn on. If the laser has been stored in extremely hot temperatures, allow it to cool. The laser level will not be damaged by pressing the on/off button before cooling to its proper operating temperature.
The Laser Beams Flash
The DCE088R and DCE088G have been designed to self-level up to an average of 4^ in all directions when positioned as shown in ③. If the laser is tilted so much that internal mechanism cannot level itself, the laser beam will flash indicating that the tilt range has been exceeded. The flashing beams created by the laser are not level or plumb and should not be used for determining or marking level or plumb. Try repositioning the laser on a more level surface.
The Laser Beams Will Not Stop Moving
The DCE088R and DCE088G are precision instruments. Therefore, if the laser is not positioned on a stable (and motionless) surface, the laser will continue to try to find level. If the beam will not stop moving, try placing the laser on a more stable surface. Also, try to make sure that the surface is relatively flat, so that the laser is stable.
The Battery Meter LED's Flash
When all 4 LED's continuously flash on the Battery Meter this indicates that the unit has not been fully powered off using the Pendulum Lock switch B. The Pendulum Lock switch should always be placed in the LOCKED/OFF position when the laser is not in use.
Service and Repairs
Note: Disassembling the laser level(s) will void all warranties on the product.
To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should be performed by authorized service centers. Service or maintenance performed by unqualified personnel may result in a risk of injury. To locate your nearest DeWALT service center go to http://www.dewalt.com on the Internet.
User Manual
Specifications
Laser Tool
| Light Source Laser diodes | ||
| Laser Wavelength 630 - 680 nm (RED) $15-535 mm (GREEN) | ||
| Laser Power ≤1.5 mw (each beam) CLASS 2 LASER PRODUCT | ||
| Working Range | ||
| 20 m (±65') (RED) 35 m (±115') GREEN | ||
| 50 m with detector 50 m with detector | ||
| Accuracy (Level): ±3 mm per 9 m (±1/8' per 30') | ||
| Indicators | ||
| Battery Low 1 x LED Flashing on Battery meter | ||
| Unit Not Powered Off With Pendulum Lock Switch | 4 x LED Flashing on Battery meter | |
| Flashing Laser Beams Tilt range exceeded/unit is not level | ||
| Power Source 4 AA (1.5V) size batteries | (6.0V DC) or 10.8 Li Ion DEWALT Rechargeable Battery Pack. | |
| Operating Temperature -10 °C to 45 °C | 20 °F to 115 °F | |
| Storage Temperature -20 °C to 60 °C (-5 °F to 140 °F) | ||
| Humidity Maximum relative humidity 80% | for temperatures up to 31 °C (88 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F) | |
| Environmental Water & Dust Resistant to IP65 | ||
1 Year Limited Warranty
DeWalt will repair, without charge, any defects due to faulty materials or workmanship for one year from the date of purchase. This warranty does not cover part failure due to normal wear or tool abuse. For further detail of warranty coverage and warranty repair information, visit www.dewalt.com.
This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces.
In addition to the warranty, DeWALT tools are covered by our:
1 Year Free Service
DeWalt will maintain the tool and replace worn parts caused by normal use, free, any time during the first year after purchase.
30 DAY no risk satisfaction GUARANTEE
If you are not completely satisfied with the performance of your DeWalt Laser, for any reason, you can return it within 30 days from the date of purchase with a receipt for a full refund – no questions asked.
Free Warning Label Replacement:
If your warning labels ① become illegible or are missing, visit www.dewalt.com for a free replacement.
Notes
Benutzerhandbuch
Inhalt
15 m (50') 5,0 mm (7/32")
Faisceau vertical (voir figure 8)
| Distanza tra le pareti Distanza consentita tra i contrassegni |
| 9 m (1/30") 3,0 mm (1/8") |
| 12 m (1/40") 4,0 mm (5/32") |
| 15 m (1/50") 5,0 mm (7/32") |
| Distanza tra le pareti Distanza consentita tra i contrassegni |
| 9 m (1/30") 6,0 mm (1/4") |
| 12 m (1/40") 8,0 mm (5/16") |
| 15 m (1/50") 10,0 mm (13/32") |
| Distência entre as paredes | Distência permissível entre as margas |
| 9 m 3,0 mm | |
| 12 m 4,0 mm | |
| 15 m 5,0 mm |
| Distência entre as paredes | Distência permissível entre as marca |
| 9 m 6,0 mm | |
| 12 m 8,0 mm | |
| 15 m 10,0 mm |
golflene in nanometers
2 Klasse 2 Laser

adverselssymbol for laser
laser, adverselssymbol
nm bøgelengde i nanometer
2 Klasse 2 Laser

Ikke se inn i laserstralen.
Advarselsmerking
| Duvarlar Arasindaki Mesafe | İşaretler Arasinda ilez Verilen Mesafe |
| 9 m (30') 3,0 mm (1/3") | |
| 12 m (40') 4,0 mm (5/32") | |
| 15 m (50') 5,0 mm (7/32") |
Dogruluk Kontrolü -
| Duvarlar Arasindaki Mesafe | İşaretler Arasinda İzin Verilen Mesafe |
| 9 m (30') 6,0 mm (1/4") | |
| 12 m (40') 8,0 mm (5/16") | |
| 15 m (50') 10,0 mm (1/32") |