BLOMBERG DKP2160 - Basket

DKP2160 - Basket BLOMBERG - Free user manual and instructions

Find the device manual for free DKP2160 BLOMBERG in PDF.

📄 84 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice BLOMBERG DKP2160 - page 6
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Kitchen hood
Brand Blomberg
Model DKP2160
Installation Mode Extracting or recirculating
Minimum Safety Distance 650 mm above the cooking surface
Air Outlet Diameter 120 mm (150 mm adapter included)
Electrical Supply 230 V ~ 50 Hz (check rating plate)
Lighting Type 2 x incandescent lamps 40 W max
Number of Speeds 4 speeds + intensive speed
Filter Type Metal grease filter (washable) + activated carbon filter (replaceable)
Grease Filter Maintenance Dishwasher wash every 2 months
Carbon Filter Replacement Every 4 months (not washable)
Hood Cleaning Damp cloth and neutral detergent
Safety Mandatory earthing, do not flambé under the hood
Intended Use Domestic only
Environmental Information Mandatory WEEE recycling, do not dispose with household waste

Frequently Asked Questions - DKP2160 BLOMBERG

What is the minimum distance between the hood and the hob?
The minimum safety distance is 650 mm for correct installation.
Can I use the hood in recirculation mode?
Yes, the hood can be used in filtering version with an activated carbon filter (not supplied) to recirculate the air.
How do I clean the grease filters?
The metal grease filters are dishwasher safe. It is recommended to wash them every 2 months.
When should I replace the carbon filter?
The activated carbon filter must be replaced every 4 months or more often with heavy use. It is neither washable nor regenerable.
How do I change the hood bulbs?
Remove the metal filters, then unscrew the old bulbs and replace them with new ones of 40 W max (incandescent). Put filters back.
What if the hood does not work?
First check the electrical supply and the main switch. Ensure the power cord connector is properly plugged. If the problem persists, contact after-sales service.
Can I use the hood with gas pans?
Yes, but ensure the room is well ventilated if using gas appliances. Never let flames extend beyond the pans.
How to set the intensive speed?
To activate the intensive speed, press the T4 button for about 2 seconds. It stops automatically after 10 minutes.
Does the hood need to be earthed?
Yes, earthing of the electrical installation is mandatory for safety. Check that the plug is compliant.
What duct diameters should I use?
Use a duct of 120 mm minimum diameter. A 150 mm to 120 mm adapter is supplied for larger outlets.

User questions about DKP2160 BLOMBERG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Basket in PDF format for free! Find your manual DKP2160 - BLOMBERG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DKP2160 by BLOMBERG.

USER MANUAL DKP2160 BLOMBERG

RECOMMENDATIONS AND SUGGESTIONS 4

CHARACTERISTICS 5

INSTALLATION 6

USE 9

MAINTENANCE 11

SOMMAIRE

FR

CONSEILS ET SUGGESTIONS 12

CHARACTERISTIQUES 13

INSTALLATION 14

UTILISATION 17

ENTRETIEN 19

INHALTSVERZEICHNIS

DE

The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance.

INSTALLATION

  • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
  • The minimum safety distance between the cooker top and the extractor hood is 650~mm .
  • Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
  • For Class I appliances, check that the domestic power supply guarantees adequate earthing.

Connect the extractor to the exhaust flue through a pipe of minimum diameter 120mm . The route of the flue must be as short as possible.

  • Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
  • If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.

USE

  • The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.
  • Never use the hood for purposes other than for which it has been designed.
  • Never leave high naked flames under the hood when it is in operation.
  • Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
  • Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
  • Do not flambe under the range hood; risk of fire
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
    Children should be supervised to ensure that they do not play with the appliance

MAINTENANCE

  • Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
  • Clean and/or replace the Filters after the specified time period.
  • Clean the hood using a damp cloth and a neutral liquid detergent.

BLOMBERG DKP2160 - MAINTENANCE - 1

BLOMBERG DKP2160 - MAINTENANCE - 2

BLOMBERG DKP2160 - MAINTENANCE - 3

BLOMBERG DKP2160 - MAINTENANCE - 4
Dimensions

BLOMBERG DKP2160 - MAINTENANCE - 5

BLOMBERG DKP2160 - MAINTENANCE - 6
Components

Ref. Q.ty Product Components

1 1 Hood Body, complete with: Controls, Light, Blower, Filters

2 1 Telescopic Chimney comprising:
2.1 1 Upper Section
2.2 1 Lower Section
9 1 Reducer Flange 150-120 mm
14.1 2 Air Outlet Connection Extension
15 1 Air Outlet Connection

Ref. Q.ty Installation Components

7.2.1 2 Upper Chimney Section Fixing Brackets

11 6 Wall Plugs

12a 6 Screws 4,2× 44,4

12c 6 Screws 2,9 x 9,5

Q.ty Documentation

1 Instruction Manual

BLOMBERG DKP2160 - MAINTENANCE - 7

Wall drilling and bracket fixing

BLOMBERG DKP2160 - Wall drilling and bracket fixing - 1

Wall marking:

  • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed.
  • Draw a horizontal line at 650mm above the hob. Place bracket 7.2.1 on the wall as shown about 1 - 2mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line.
  • Mark the wall at the centres of the holes in the bracket.
  • Place bracket 7.2.1 on the wall as shown at X mm below the first bracket ( X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line.
  • Mark the wall at the centres of the holes in the bracket.
  • Mark a reference point as indicated at 116mm from the vertical reference line and 320mm above the horizontal reference line.
  • Repeat this operation on the other side.
  • Drill 8mm holes at all the centre points marked.
  • Insert the wall plugs 11 in the holes.
    Fix the brackets using the 12a (4,2 x 44,4) screws supplied.
  • Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap of 5 - 6mm between the wall and the head of the screw.

Mounting the hood body

  • Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points.
  • Hook the hood body onto the screws 12a.
  • Fully tighten the support screws 12a.
  • Adjust the screws Vr to level the hood body.

BLOMBERG DKP2160 - Mounting the hood body - 1

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe 150 or 120mm the choice of which is left to the installer.

  • To install a 120mm air exhaust connection, insert the reducer flange 9 on the hood body outlet.
    Fix the pipe in position using sufficient pipe clamps (not supplied).
  • Remove possible charcoal filters.

BLOMBERG DKP2160 - DUCTED VERSION AIR EXHAUST SYSTEM - 1

RECIRCULATION VERSION AIR OUTLET

  • Push fit connection 15 onto the hood body outlet.
  • Insert the connection extension pieces laterally 14.1 in connection 15.
  • Make sure that the outlet of the extension pieces 14.1 is horizontally and vertically aligned with the chimney outlets. If this is not the case, adjust the position by either reversing the connection extension pieces 14.1 and then reassemble as described previously.
  • Ensure that the activated charcoal filters have been inserted.

BLOMBERG DKP2160 - RECIRCULATION VERSION AIR OUTLET - 1

ELECTRICAL CONNECTION

  • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3mm .
  • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.

BLOMBERG DKP2160 - ELECTRICAL CONNECTION - 1

Chimney assembly

Upper exhaust Chimney

  • Slightly widen the two sides of the upper chimney and hook them behind the brackets 7.2.1, making sure that they are well seated.
  • Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied.

Lower exhaust Chimney

  • Slightly widen the two sides of the chimney and hook them between the upper chimney and the wall, making sure that they are well seated.
    Fix the lower part laterally to the hood body using the 2 screws 12c (2,9× 9,5) supplied.

BLOMBERG DKP2160 - Lower exhaust Chimney - 1

BLOMBERG DKP2160 - Lower exhaust Chimney - 2

Control panel

KEYLEDFUNCTIONS
L 0/1 LightTurns lighting on and off.
T10/1 MotoronFirst speed.
When pressed for about 1 seconds the motor is switched off.
T2SpeedonSecond speed.
T3SpeedonThird speed.
T4SpeedFixedMax. speed
FlashingIntensive speed.
Suitable for the strongest cooking vapours and odours. The func- tion becomes active when the button is pushed for about 2 sec- ons. After 10 minutes of functioning it turns off automatically.
This function can be interrupted by means of pressing any of the buttons.

BLOMBERG DKP2160 - Lower exhaust Chimney - 3

L Light Switches the lighting system on and off.

S Led Motor running led.

V1 Motor Switches the extractor motor on and off at low speed. Used to provide a continu- uos and silent air change in the presence of light cooking vapours.
V2 Speed Medium speed, suitable for most operating conditions given the optimum treated air floss/noise level ratio.
V3 Intensive Maximum speed, used for eliminating the highest cooking vapour emission, including long periods.

Grease filters

CLEANING METAL SELF- SUPPORTING GREASE FILTERS

  • The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher.
  • Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
  • Wash the filters, taking care not to bend them. Allow them to dry before refitting.
  • When refitting the filters, make sure that the handle is visible on the outside.

BLOMBERG DKP2160 - CLEANING METAL SELF- SUPPORTING GREASE FILTERS - 1

Activated charcoal filter (Recirculation version)

REPLACING THE ACTIVATED CHARCOAL FILTER

  • The filter is not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently for particularly heavy usage.
  • Remove the metal grease filters.
  • Remove the saturated activated carbon filter by releasing the fixing hooks.
  • Fit the new filter by hooking it into its seating.
  • Refit the metal grease filters.

BLOMBERG DKP2160 - REPLACING THE ACTIVATED CHARCOAL FILTER - 1

Lighting

LIGHT REPLACEMENT

40 W incandescent light.

  • Remove the metal grease filters.
  • Unscrew the bulbs and replace them with new ones having the same characteristics.
  • Replace the metal grease filters.

BLOMBERG DKP2160 - W incandescent light. - 1

REEMPLACEMENT LAMPES

Ref. Installatieonderdelen

JIy yCTaHOBKn BCacbIBaHOIeB bITJXKN COeINHHTb ee c BbIpyCKHO Tpy6oN JecTKO HJIN rH6KO Tpy6KOJ nnAmetpOM 150 HJN 120 MM, TII KOtOpO MoKcT Bbl-6paTB MOHTaKHNK.

IIO coeHHeHH TpyokO 120 MM BCTABHb IepexoHbI HJIaHE9B BBbYCKHOc OTBepTHe KOpHyCa BBJrKHN.
3aKpeHITb Tpy6ky COOTBeTCTByIOHMN Tpy6HbIMN 3aKHMAMn. Heo6XoIIMbI KpeIIeKHH MaTepHaJI He BXOJNT B KOMIIJEKT.
BbHyTb HJbTpbl OT 3aIIaxOB Ha aKTHBHOM yJIe.

BLOMBERG DKP2160 - REEMPLACEMENT LAMPES - 1

BbInyck BO3dYxA N3 ΦnIbTPyIOUeN BbITaXKN

Bbntb npyok 15 B BBnucKhoe OTBepCThe KopNyca BbITJKKN.
BcTaBnTb c 6oky Hacaikn IaTppy6ka 14.1 B IaTppy6ok 15.
IPOBepHTb,TO6bIBBnYCKHOEOTBepCTHe HacaIOK IIATpy6ka 14.1 COBIIaJIO C OTBepCTHmN IbIMOXOJa, KaIK IIO ROPn3OHTaJIN, TaK IN IO BepTHKaJIN. EcJIn Ke OHO He COBIIaJaET, IOMeHrTb MeCTaMn HacaIKN IIATpy6ka 14.1 N yCTaHOBHTb BCE qactH, KaK OIIncAHO Bblie.
IIpoBepntb HaJIInuHne HJbTpa OT 3aIaxOB Ha aKTHB-HOM yIJe.

BLOMBERG DKP2160 - BbInyck BO3dYxA N3 ΦnIbTPyIOUeN BbITaXKN - 1

3NEKTPNUECKOE NOKNIQUOHEH

CoeHHHTb BbITKky c ceTeBbIM HaIIpJKeHHem, yCTaHOBBIByXIOJIIOCHbI BBIKIOuATEJIb C pa3BeJeHHem KOHTaKTOB He MeHee 3 MM.
CHaTb IpoTHBOXHPOBbIe HJIbTpBI (CMOTpHa3JeJ "YxoJ") H IpoBepHTb IIpaBnJIbHOCTb IOIOKeHHa pa3bema IITaIOIIeRo Ka6eJI B pO3ETKE BBITJIKN

BLOMBERG DKP2160 - 3NEKTPNUECKOE NOKNIQUOHEH - 1

yctahOBka dbIMOXOda

BepxHn IbIMoxoI

Cnerka pa3BecTH IBe 6OKOBbIe KpOMKn IbIMOXOJa, 3aIIeINHTb Hx 3a cKO6bl 7.2.1 IN BHO8b CBeCTH Hx IO yIInpa.
3aKpeINb IbIMOXoI c6Oky 4 BXOJIINHM B KOMJIeKT BHTaMn 12c (2,9 x 9.5).

HnKnnIyBIMoxO

CJIeKa pa3BecTH IBe 6OKOBbIe KpOMKn IbIMOXOJa, 3aIeHITb HX MEJy BEPHM IbIMOXOOM H CTeHOH H BHOB CBecTH HX IO YIopa.
3aKpeHb HxHHIO qactb IbIMOXOa c60ky K Kopny Cy BbTTKHN BXOJIINHM B KOMIIJEKT 2 BHHTAMN 12c (2,9 x 9,5).

BLOMBERG DKP2160 - HnKnnIyBIMoxO - 1

BLOMBERG DKP2160 - HnKnnIyBIMoxO - 2

Panaelb ynpaBneHnA

The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : BLOMBERG

Model : DKP2160

Category : Basket