CK150 - Range hood DOMETIC - Free user manual and instructions
Find the device manual for free CK150 DOMETIC in PDF.
| Brand | DOMETIC |
| Model | CK150 |
| Product type | Extractor hood for caravans, motorhomes and boats |
| Dimensions (W x H x D) | 400 x 45 x 165 mm |
| Weight | 1.9 kg |
| Power supply | 12 V= (battery) |
| Suction capacity | 115 m³/h |
| Power consumption | 30 W |
| Lighting power consumption | 5 W |
| Integrated lighting | Yes, separate switch |
| Filter | Removable and washable with hot water and detergent |
| Mounting | Built into a wall cabinet above the hob |
| Minimum distance to flames | 50 cm |
| Electrical installation | Direct connection to 12 V battery with 4 A fuse |
| Fan | Roof-mounted, max tilt 20° |
| Delivery contents | Hood, cover, skylight, fan, gasket, clamps, filter, screws |
| Cleaning | Clean the filter regularly; do not use sharp objects or abrasive detergents |
| Safety | Installation and repairs by a qualified professional; do not insert objects into openings |
| Warranty | Legal warranty; contact the manufacturer or retailer |
| Repairability | Repairs exclusively by authorized after-sales service |
| Intended use | Removal of cooking odors and vapors in leisure vehicles and boats |
Frequently Asked Questions - CK150 DOMETIC
User questions about CK150 DOMETIC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Range hood in PDF format for free! Find your manual CK150 - DOMETIC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CK150 by DOMETIC.
USER MANUAL CK150 DOMETIC
Installation and Operating Manual. 7

Dunstabzugshaube
Please read this instruction manual carefully before installation and first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it.
Contents
1 Explanation of symbols. 8 2 Safety instructions 8 3 Scope of delivery 10 4 Intended use 10 5 Technical description 10 6 Mounting the extractor hood. 11 7 Using the extractor hood 13 8 Cleaning 13 9 Disposal 14 10 Warranty 14 11 Technical data 14
1 Explanation of symbols

WARNING!
Safety instruction: Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

CAUTION!
Safety instruction: Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.

NOTICE!
Indicates a situation that, if not avoided, can result in property damage.

NOTE
Supplementary information for operating the product.
2 Safety instructions
Please observe the prescribed safety instructions and stipulations from the vehicle manufacturer and service workshops.
The manufacturer accepts no liability for damage in the following cases:
- Faulty assembly or connection
- Damage to the product resulting from mechanical influences and incorrect connection voltage
- Alterations to the product without express permission from the manufacturer
- Use for purposes other than those described in the operating manual
Note the following basic safety information when using electrical devices to protect against:
Electric shock, fire hazards, injury
2.1 Handling the device

WARNING!
- Installation and repair of the extractor hood may only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations.
- Inadequate repairs may cause serious hazards. For repair service, please contact the service centre in your country (addresses on the back page).
- People (including children) whose physical, sensory, or mental capacities or whose lack of experience or knowledge prevent them from using this product safely should not use it without the supervision or instruction of a responsible person.
- Installation work and electrical wiring must be performed by skilled technicians in compliance with all applicable regulations and standards.
- When cutting or drilling into walls or ceilings, make sure that no electrical cables or hidden devices are damaged.
- To reduce the risk of fire, use only pipes of the UL94-HB class or higher.
- The distance between the gas hob flame and the extractor hood must be at least 50 cm.

CAUTION!
- The extractor hood must be installed securely so that it cannot fall down.
- Only operate the extractor hood if you are certain that the housing and the cables are not damaged.
- Make sure no combustible objects are stored or installed near the air outlet. A distance of at least 50 cm must be maintained.
- Do not reach into the air outlet or insert any foreign objects into the device.
3 SCOPE OF DELIVERY
| No. in fig. 1, Quantity Description page 3 | |||
| 11 Extractor fan | |||
| 21 Cover cap | |||
| 31 Roof hood | |||
| 4 | 1 | F | a |
| 51 Rubber seal | |||
| 61 Hose clip | |||
| 71 Pipeline | |||
| 81 Hose clip | |||
| 91 Filter | |||
| 106 Bolts, 4.2 x 25 | |||
| 11 | 3 Bolts, 4.2 x 13 | ||
| 123 Bolts, 3.5 x 9.5 | |||
| 134 Bolts, 3.5 x 13 | |||
| 14 | 1 Bolt, 3.5 x 25 | ||
4 Intended use
The extractor hood CK150 is designed for installation in caravans, motorhomes and boats.
5 Technical description
The extractor hood CK150 removes odours and steam that arises during cooking. The device is equipped with a removable and washable filter, a built-in lamp and a fan. It is connected via a flexible pipeline with the interior area and can be mounted on the roof of the motorhome due to its weather-resistant cover cap.
5.1 Control elements
| No. in fig. 2, Description page 3 | |
| 1 Filter | |
| 2 | Fan On/Off switch |
| 3 | Light On/Off switch |
| 4 Lamp | |
6 Mounting
Note on installation location
The extractor hood should preferably be mounted above the cooking zone and built into a suspended cabinet if possible. The distance between the gas hob flame and the extractor hood must be at least 50 cm.
The fan should be mounted on the roof on a level surface. When mounted on a sloping surface, the roof hood must be rotated so that one of the three water drainage holes is directed toward the incline. A tilt angle up to 20 degrees will not affect the performance of the fan when the motor is not running.
6.1 Mounting the fan
Select an appropriate installation location for the fan on the roof. Draw the location and size of the opening of 105 mm diameter (fig. 3, page 4). Pre-drill and cut out the hole on the roof carefully with a keyhole saw or similar tool. Place the fan on the opening and mark the six screw holes. Apply a thin ring of a permanently elastic sealing material around each hole. Put the rubber seal (fig. 5 4, page 4) into the groove on the underside of the fan.

NOTE
Pull the fan on tightly enough that the rubber seal is seamlessly in contact with the roof.
Attach the fan (fig. 5 3, page 4) with the six included bolts (4.2 x 25). Attach the roof hood (fig. 5 2, page 4) with the three included bolts (3.5 x 9.5). Attach the cover cap (fig. 5 1, page 4) with the three included bolts (4.2 x 13).
6.2 Mounting the extractor hood

WARNING!
- Attach the extractor hood preferably over the cooking zone and install it in a suspended cabinet.
- The distance between the gas hob flame and the extractor hood must be at least 50 cm.
Choose a suitable installation location in the interior for the extractor hood. Draw the location and size of the section of 381 x 142 mm on the bottom of the suspended cabinet (fig. 4, page 4). Pre-drill and cut out the section carefully with a keyhole saw or similar tool. Insert the extractor hood from below into the cabinet and secure it with the four included bolts (3.5 x 13) (fig. 6, page 5). Attach the hose (fig. 6 3, page 4) to the extractor hood (fig. 6 5, page 4) and the fan (fig. 6 1, page 4) with the hose clips (fig. 6 2 and 4, page 4). Insert the filter (fig. 2 1, page 3) into the extractor hood.
6.3 Connecting the extractor hood electrically
Connect the fan to the battery; see fig. 7, page 6.
Key
| No. in fig. 7, page 6 | Description |
| 1 | Fan |
| 2, 3 | Fuse holder with fuse 4 AT (5 x 20 mm) |
| No. in fig. 7, Description page 6 |
| 4 Battery (12 V=) |
| sw Black |
| ws White |
| rt Red |
7 Using the extractor hood
Switching the extractor hood on and off
Turn the extractor hood on and off with switch O (fig. 2, page 3).
Switching the light on and off
Turn the light on and off with switch O'' (fig. 2, page 3).
8 Cleaning

NOTE
The filter of the extractor hood must be cleaned regularly, as grease collects there. How often cleaning is necessary depends on how often you cook and how often the extractor hood is switched on. Do not wait for the performance of the extractor hood to noticeably decline before you clean the filter.

NOTICE! Damage hazard
Do not use sharp or hard objects or cleaning agents for cleaning as these may damage the product.
Occasionally clean the product with a damp cloth. Remove the filter and clean it with warm water and a synthetic detergent (such as washing-up liquid).
9 Disposal
Place the packaging material in the appropriate recycling waste bins wherever possible.

If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
10 Warranty
The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see back page) or your retailer.
For repair and warranty processing, please include the following documents when you send in the device:
A copy of the receipt with purchasing date - A reason for the claim or description of the fault
11 Technical data
| CK150 | |
| Reference number: 9103303095 | |
| Connection voltage: 12 V== | |
| Capacity: | 115 m3/h |
| Power consumption: 30 W | |
| Power consumption lighting: 5 W | |
| Dimensions (W x H x D): | 400 x 45 x 165 mm |
| Weight: | 1.9 kg |
| Test mark: | CE ⑤ |
5 Technical description
6.1 Mounting the extractor
- The extractor must be installed in such a way as to eliminate the risk of it falling.
- Operate the extractor only when the housing and cable are undamaged. Ensure that flammable objects are not stored or placed in the air outlet zone. The distance must be at least 50 cm. Do not insert hands into the exhaust ventilation opening and do not insert foreign objects into the appliance.
9 1 Φ n T 106BnHTb4,2×25 113BnHTbI4,2x13 123BnHTbI3,5×9,5 134BnHTb3,5×13 141 BnHT 3,5×25
The extractor hood is recommended to be installed above the hob, if possible, built into a hanging cabinet. The distance between the hob and the extractor hood must be at least 50 cm.
The fan must be mounted on the roof on as flat a surface as possible. When installing on a sloped roof, the air intake must be turned so that one of the three drain holes is facing the slope. A slope angle of up to 20° does not affect the fan performance when the motor is not running.
6.1 Fan installation
Choose a suitable location on the roof for the fan. Mark the location and the size of the hole with a diameter of 105 mm (Fig. 3, p. 4).
Pre-drill and cut the hole in the roof with a jigsaw or similar. Place the fan over the hole and mark the six screw holes. Apply a bead of sealant around each hole. Insert the rubber gasket (Fig. 5 4, p. 4) into the groove on the underside of the fan.

NOTE
Tighten the fan so that the rubber gasket fits snugly against the roof.
Secure the fan (Fig. 5 3, p. 4) with the six screws supplied (4.2x25). Secure the air intake cover (Fig. 5 2, p. 4) with the three screws supplied (3.5×9.5). Secure the cover (Fig. 5 1, p. 4) with the three screws supplied (4.2 x 13).
6.2 Extractor hood installation

WARNING!
Place the extractor hood above the hob and build it into the hanging cabinet. The distance between the hob and the extractor hood must be at least 50 cm.
Choose a suitable location in the cabinet for the extractor hood installation. Mark the position and the size of the hole 381x142 mm in the bottom of the hanging cabinet (Fig. 4, p. 4).
Pre-drill and cut the hole with a jigsaw or similar. Insert the extractor hood from below into the cabinet and secure it with the four screws supplied (3.5×13) (Fig. 6, p. 5). Attach the duct (Fig. 6 3, p. 4) to the extractor hood (Fig. 6 5, p. 4) and to the fan (Fig. 6 1, p. 4) with the duct clamps (Fig. 6 2 and 4, p. 4). Install the filter in the extractor hood (Fig. 2 1, p. 3).
6.3 Connecting the extractor hood to the electrical network
Turn on the fan with the battery, see fig. 7, page 6.
| Пос. на пс. 7, Onиси ст. 6 |
| 1 B e H T I N J T O P |
| 2,3 Держател лpop adequately с лpop adequately слр adequately слр adequately 4 A T (5 x 20 MM) |
| 4 Актулароня батер (12 B---) |
| SW черный |
| WS_SEль |
| rt красный |
dometic.com/sales-offices