Fuxtec FX-TP11100INOX - Water pump

FX-TP11100INOX - Water pump Fuxtec - Free user manual and instructions

Find the device manual for free FX-TP11100INOX Fuxtec in PDF.

📄 92 pages English EN Download 💬 AI Question
Notice Fuxtec FX-TP11100INOX - page 17
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about FX-TP11100INOX Fuxtec

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Water pump in PDF format for free! Find your manual FX-TP11100INOX - Fuxtec and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FX-TP11100INOX by Fuxtec.

USER MANUAL FX-TP11100INOX Fuxtec

POLSKA WERSJA JEZYKOWA 83

Inhalt

DEUTSCHE VERSION....6

POLSKA WERSJA JEZYKOWA 83

text_image Technical diagram of a water pump with numbered components and labeled parts
natural_image 3D rendering of a mechanical component with radial slots and mounting holes (no visible text or symbols)

We are pleased with your trust!

Please read these instructions for use before the first use and before every use!

Here you will find all the information you need for safe use and long service life of the device. It is imperative that you observe all safety instructions in this manual!

Please keep this manual always together with the device, so that you still have it at hand in case of doubt.

Fuxtec FX-TP11100INOX - DEUTSCHE VERSION....6 - 1

IMPORTANT: To avoid the risk of injuries, every user has to read the manual before using the tool.

FUXTEC GMBH KAPPSTRASSE 69, 71083 HERRENBERG-GÜLTSTEIN, GERMANY

9. English Version of the manual

Technical specifications:

Fuxtec FX-TP11100INOX - English Version of the manual - 1FX-RTP350FX-TP1250FX-TP1350FX-TP1750FX-TP11100INOX
Fuxtec FX-TP11100INOX - English Version of the manual - 2230V/50HZ230V/50HZ230V/50HZ230V/50HZ230V/50HZ230V/50HZ
Fuxtec FX-TP11100INOX - English Version of the manual - 3350 Watt250 Watt350 Watt750 Watt1100 Watt1100 Watt
Fuxtec FX-TP11100INOX - English Version of the manual - 4IPX8IPX8IPX8IPX8IPX8IPX8
Fuxtec FX-TP11100INOX - English Version of the manual - 55200l/h6000l/h7500l/h12000l/h15000l/h15000l/h
Fuxtec FX-TP11100INOX - English Version of the manual - 611m6m6m9,5m11m11m
Fuxtec FX-TP11100INOX - English Version of the manual - 77m7m7m7m7m7m
Fuxtec FX-TP11100INOX - English Version of the manual - 8<35°C<35°C<35°C<35°C<35°C<35°C
Fuxtec FX-TP11100INOX - English Version of the manual - 95mm5mm20mm30mm35mm35mm
Fuxtec FX-TP11100INOX - English Version of the manual - 10400mm200mm400mm200mm400mm200mm400mm200mm470mm40mm470mm40mm
Fuxtec FX-TP11100INOX - English Version of the manual - 11130mm130mm130mm130mm130mm130mm
Fuxtec FX-TP11100INOX - English Version of the manual - 1210m10m10m10m10m10m
Fuxtec FX-TP11100INOX - English Version of the manual - 134,3kg4,9kg4,9kg5,6kg7,3kg7,8kg

10. SECURITY INSTRUCTIONS FOR YOUR SAFETY AND THE GOOD USE OF THE

PUMP

a) SAFETY

  • This equipment is suitable neither for drinking water nor for equipment in contact with dishes.
  • Unplug the equipment from the mains before any intervention.
  • When the pump is running, there must be no particles in the water (clean water only).
  • Do not use the pump without a residual-current device
  • The pump must be used with 230V AC Power supply, as indicated on the rating plate.
  • Do not use the power cable for carrying the pump or for unplugging.
  • Make sure that electric connections are protected from humidity.
  • Avoid dry-running of the pump. Never use the pump if suction hose is obstructed.
  • It is strictly forbidden to pump corrosive, easily combustible, aggressive or explosive liquids (such as gasoline, petroleum or nitro thinner), saltwater and food

- The temperature of the liquid must not exceed 35^ .

• (30mA).

- Do not use the pump if safety devices are damaged or depleted. Never deactivate safety devices.

b) PUMP ENVIRONMENT

  • Do not operate pumps in explosive atmospheres, such as in the presence of flammable liquids, gases or dust.
  • Keep children and unqualified persons away from the pump when it is in use.

c) ELECTRIC SAFETY

- The pump cable plug must match the socket. Never modify the plug in any way. Do not use any adapter plugs. Unmodified plugs and matching sockets will reduce risk of electric shock.

- Avoid body contact with earthed or grounded surfaces.

- Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the pump. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock.

- When operating a pump outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.

- The pump is equipped with a socket compatible with it. The power source of your country must be in keeping with international regulations.

- If supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard.

d) PERSONAL SAFETY

  • Risk of injury due to hot water. If the pump runs for an extended period when the outlet is closed, the water in the pump can become heated so that hot water can emerge from the outlet and cause injuries.
  • Stay alert, watch what you are doing and use common sense when operating a pump.
  • Maintain your pump. If the pump is damaged, make it repair by a specialist before any use.
  • Follow these instructions to use the pump, its accessories, connectors, etc... properly. The pump must be used only for its prescribed purpose. Any use other than those mentioned in this Manual will be considered a case of misuse.
  • This pump is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • It is necessary to keep children under surveillance, and to make sure that they are not playing with the pump, or its power cord. Keep children away from the pump when operating.

SYMBOL

Fuxtec FX-TP11100INOX - SYMBOL - 1

The pump must not be disposed of with normal household waste but must be disposed of in accordance with local environmental regulations.

Fuxtec FX-TP11100INOX - SYMBOL - 2

Conformity with safety rules applicable in the EU market.

Fuxtec FX-TP11100INOX - SYMBOL - 3

Read the instructions before use.

To be checked before you start

Pumps have been designed to suck clear water only.

Drain pumps have been designed to suck clear water or dirty water with particles.

The pump must be installed on a flat and solid surface.

It is not suitable for professional use (including continuous operation)

11. GETTING STARTED

1, Connect a discharge pipe with a diameter at least equal to the diameter of the pump outlet
2. Immerse the pump in the liquid to be sucked, by making an angle of 45 degrees (to reduce the amount of air trapped in the pump body). If the pump rests on the bottom, make sure it is on a flat and stable surface.
3. Make sure that no one is present in the liquid to be pumped

4. Plug the pump to the mains

USE AND DESTINATION OF THE PUMP

Your pump is designed for domestic use. It can be used to remove or transferring.

Your pump must not be used in following situations:

• Water temperature to be sucked > 35°C
• Continuous run (ex: fountain pump)
- Drinking water supply or washing machines for dishes supply
- Corrosive, easily combustible, aggressive or explosive liquids (such as gasoline, petroleum or nitro thinner), saltwater, oils and greases must not be pumped
• Permanent submersion under 3 meters or more water

12. ACCESSORIES

  • Connector: 1pc;
    • Universal Fitting: 1pc;
  • O-ring: 2pcs;
  • Manual: 1pc

13. USE AND DESTINATION OF THE PUMP

Your pump is designed for domestic use. It can be used to remove or transferring.

Your pump must not be used in following situations:

• Water temperature to be sucked > 35°C
• Continuous run (ex: fountain pump)
- Drinking water supply or washing machines for dishes supply
- Corrosive, easily combustible, aggressive or explosive liquids (such as gasoline, petroleum or nitro thinner), saltwater, oils and greases must not be pumped
• Permanent submersion under 3 meters or more water

14. CARE & MAINTENANCE

• In case of temporary installation, the pump must be cleaned up with clear water after use.
- In case of permanent installation, it is necessary to check every 3 months that start mechanism is working properly (float switch or sensor).
- Regularly remove dirt that may accumulate in the sump.
- Do not expose to frost.
- Avoid dry run.
- Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the pump.
- Clean the pump regularly if aspirated liquid cause sediments.

- Avoid shocks, do not let the pump fall

TROUBLESHOOTING

TroublePIs checkShould do
The engine does not start and does not make noise.Is the pump plugged?Does the pump starts when fully submerged?Check your electrical installationCheck that the float can move freely
Pump does not deliver.Does the impeller rotates?Is it in good condition?Is the pump inlet free?The delivery head requested exceeds the requirements of the pump or the discharge pipe is too narrowEliminate the reason for blockingReplace the impellerClean the pump inletUse the pump in accordance with its technical capabilitiesIncrease the pipe diameter
The pump stops suddenlyIs there a sufficient water level to suck?Did the pump run for a long time without stopping?Are you sure that the pump inlet is not obstructed?Do the power of the mains match the rating plate?Is the temperature of the liquid less than 35°C?Disconnect the pump from the mains and let it cool for a few tens of minutesClean the pump inletUse a power supply matching the rating plateObserve the maximum allowable temperature
Flow decreasesIs the pump inlet clean?Is the impeller clean?The discharge pipe is not partially clogged?Clean the area or areas in question (s)
Low flow or insufficientAre you sure that the pump inlet is not obstructed?Is the impeller clean?Are you sure that the outlet pipe is not obstructed?Is the diameter of the discharge pipe enough?Clean the zone (s) concerned and verify check valve, if applicableConnecting a pipe with a suitable diameter and suppress reduction of the water passage

15. EU CERTIFICATE OF CONFORMITY

L. Zirkler, 18th of July .2023

text_image Technical diagram of a water pump with numbered components and labeled parts
natural_image Simple line drawing of a mechanical pump or motor (no text or symbols)
natural_image 3D rendering of a mechanical component with radial slots and mounting holes (no text or symbols visible)

L. Zirkler, 18.72.2023

text_image Technical diagram of a water pump with numbered components and labeled parts
natural_image 3D rendering of a mechanical component with circular and radial features (no visible text or symbols)
text_image Technical diagram of a water pump with numbered components and labeled parts
natural_image 3D rendering of a mechanical component with circular and radial features (no visible text or symbols)
text_image Technical diagram of a water pump with numbered components and labeled parts
natural_image 3D rendering of a mechanical component with radial slots and mounting holes (no text or symbols visible)
text_image Technical diagram of a water pump with numbered components and labeled parts
natural_image 3D rendering of a mechanical component with radial slots and mounting holes (no text or symbols visible)
text_image Technical diagram of a water pump with numbered components and labeled parts
natural_image 3D rendering of a mechanical component with radial slots and mounting holes (no text or symbols visible)

POLSKA WERSJA JEZYKOWA

ORYGINALNA INSTRUKCJA OBSŁUGI

text_image Technical diagram of a water pump with numbered components and labeled parts
natural_image 3D rendering of a mechanical component with radial slots and mounting holes (no text or symbols visible)
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Fuxtec

Model : FX-TP11100INOX

Category : Water pump