Güde GMP 7.21 - Pump

GMP 7.21 - Pump Güde - Free user manual and instructions

Find the device manual for free GMP 7.21 Güde in PDF.

📄 83 pages English EN Download 💬 AI Question
Notice Güde GMP 7.21 - page 18
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about GMP 7.21 Güde

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Pump in PDF format for free! Find your manual GMP 7.21 - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GMP 7.21 by Güde.

USER MANUAL GMP 7.21 Güde

natural_image Blue and black industrial pump with visible branding (no text or symbols on the pump body)

Güde GMP 7.21 - 1

GMP 7.21

94507

GÜDE GmbH & Co. KG

Birkichstrasse 6

74549 Wolpertshausen

Deutschland

Güde GMP 7.21 - GMP 7.21 - 1

ENGLISH Please read the instructions carefully before starting the machine.

English Technical Data / Device description / Safety Warnings / Specified Conditions of Use / Emergency procedure / Symbols / Maintenance / Disposal / Guarantee / Service ____12

text_image 1 STOP ON MIN MAX

Güde GMP 7.21 - GMP 7.21 - 2

text_image 2 START RUN T

Güde GMP 7.21 - GMP 7.21 - 3

natural_image Close-up of a mechanical device with a metallic component and a white triangular highlight (no visible text or symbols)

Güde GMP 7.21 - GMP 7.21 - 4

text_image 6-8x 3x

Güde GMP 7.21 - GMP 7.21 - 5

text_image 4 | START

Güde GMP 7.21 - GMP 7.21 - 6

text_image 5 START T RUN

Güde GMP 7.21 - GMP 7.21 - 7

text_image 6 STOP ON MIN MAX

Güde GMP 7.21 - GMP 7.21 - 8

text_image MAX

Güde GMP 7.21 - GMP 7.21 - 9

Güde GMP 7.21 - GMP 7.21 - 10

Güde GMP 7.21 - GMP 7.21 - 11

Güde GMP 7.21 - GMP 7.21 - 12

text_image 1 STOP STOP ON MIN MAX

Kennzeichnung:

Warnungen/Verbote:

Please read carefully these Operating Instructions before putting the appliance into operation.

A.V.2

Any reprints, even partial, are subject to approval. Technical changes reserved.

Identification:

Warnings/prohibitions:
Güde GMP 7.21 - Identification: - 1

text_image Fill the pump with water. Other persons must step aside at a sufficient distance.

Güde GMP 7.21 - Identification: - 2

text_image STOP WARNING instructions for refuelling THrottle lever adjustment
![]('img_url')![]('img_url')
General warning instructionsUse outdoors only, toxic flue gases

Product safety:

CE
The product complies with relevant EU standards

Environment protection:

Güde GMP 7.21 - Identification: - 3Güde GMP 7.21 - Identification: - 4
Dispose waste not to harm your environment.Packaging material from cardboard can be recycled in a collection point.
Defective and/or disposed electric or electronic devices must be delivered to relevant collection points.

Technical data:

Güde GMP 7.21 - Identification: - 5Güde GMP 7.21 - Identification: - 6
Motor power Volume of cylinders
Güde GMP 7.21 - Identification: - 7Güde GMP 7.21 - Identification: - 8
Delivered volume Suction lift
Güde GMP 7.21 - Identification: - 9Güde GMP 7.21 - Identification: - 10
Total head Weight
Güde GMP 7.21 - Identification: - 11Güde GMP 7.21 - Identification: - 12
Noise level Pressure connection

Technical information GMP 7.21

Engine type (air cooled)2-stroke motor
Volume of cylinders 52 ccm
Motor power 1,45 kW-2,0 hp
Max delivered volume7.000 l/h
Max suction lift 8 m
Max total head 24 m
∅ pressure/suction connector1"
Tank volume 1,3 l
Pressure connector 1" AG
Fuel 1:25 mixture
Engine oil 10W-40
Max water temperaturebis + 35°C
Noise level LWA 112 dB
Weight 7 kg
Dimensions length x width x height340x295x340 mm

General safety instructions

⚠ The device must always be disconnected from the mains before assembly, disassembly or cleaning.

Equipment can be used by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the equipment in a safe way and understand the hazards involved.

Do not allow children to play with the equipment. Pumps without indication that they are protected against freezing must not

be left outdoors in freezing conditions.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.

Please read through this user guide and make sure you know all controls and proper use of this product. We shall not be responsible for damage caused by non-adherence of the instructions and procedures in this user guide. Damage due to non-adherence of the instructions and procedures are excluded from warranty. Keep the user guide well and pass it to a new owner of the machine.

Children and person not informed about content of this user guide must not operate the machine. Supervise children to prevent playing with the machine. Applicable directives in certain countries restrict minimum age of the potential user and these directives must be respected.

Physically and mentally handicapped persons or persons with sensorial limitations must not operate the machine albeit under supervision of a security engineer or based on instructions for operation received from a responsible person.

Please obey the special safety instructions listed in the chapters of this user guide.

Cautions and instructions with the following symbol must be followed with special care:

Güde GMP 7.21 - General safety instructions - 1

Failure to comply with this instruction may in hazard to humans and/or material damage!

Check the machine for transport damage. In case of damage, inform your sales representative immediately.

Güde GMP 7.21 - General safety instructions - 2

The pump is not suitable for pumping of salt faecal solids, flammable, corrosive, explosive other dangerous liquids. Furthermore, the pump is suitable for pumping of potable water and other

Güde GMP 7.21 - General safety instructions - 3

The transported liquid must not drop below or minimum or maximum liquid temperature tied in the technical data.

Emergency Action

Apply the first aid adequate to the injury and get qualified medical assistance as quickly as possible. Protect the injured person from more accidents and calm him/her down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of information:

  1. Accident site
  2. Accident type
  3. Number of injured persons
  4. Injury type(s)

Application according to intended use

Gasoline engine pump for pumping of clean or moderately contaminated water. Any other use contradicts to the intended use. Manufacturer is not responsible for subsequent damage and injuries. Please note the appliance is intended for domestic use only.

Area of applicability

The machine is suitable for pumping of clean or moderately contaminated water.

Thanks to high performance, the model can be used industrially and in agriculture.

Standard areas of applicability of the gasoline engine pump:

■ water delivery on construction sites
- irrigation of gardens, flowerbeds, fields and raining
- pumping of water from wells, tanks, flows, streams etc.
- draining and filling of fish ponds, pits etc.

Disposal

Disposal instructions are illustrated in the form of pictograms on the device or packaging. Description of the pictograms is given in "Identification" chapter.

Disposal of transport packaging

Packaging protects the device against damage during transport. Packaging materials are usually selected according to their effect on environment and disposal methods and can therefore be recycled. Returning of the packaging back to circulation saves resources and costs for packaging disposal. Parts of the packaging (e.g. foil, styropor) may be dangerous for children. Risk of suffocation! Keep these parts of the packaging out of reach of children and dispose as soon as possible.

Operator requirements

The operators must thoroughly read operation manual before use.

Qualification

Except for thorough training by an expert for use of the device, no special qualification is required.

Minimum age

The machine may be used by persons over 18 years and trained in handling and function of the machine. Supervision is required for persons from 16 to 18 years.

An exception is use by younger person if the use takes place under supervision of an adult trainer in the course of education.

Training

Use of the device requires corresponding guidance by an expert or operation manual only. No special training is required.

Transport and storing

  • For long-term storing, the machine must be thoroughly cleaned and no unauthorized persons may have access to the machine.
  • Secure the machine against turning over before each transport.

Assembly/first commissioning

The gasoline engine pump is installed in a stable cage made from steel tubes with vibration damper. These devices must not be disassembled during operation because they provide stability and reduce vibrations.

General installation instructions

Güde GMP 7.21 - General installation instructions - 1

All connection piping must be absolutely tight. Leaking may influence operation of the pump negatively and substantial damage.

Güde GMP 7.21 - General installation instructions - 2

During installation, the machine must not be running.

All connection piping must be absolutely tight because leaking piping may influence operation of the pump negatively and cause substantial damage. Therefore, make screw connections between the pump and the piping and seal with Teflon tape. Use of the sealing material such as Teflon tape will ensure airtight assembly.

Do not overtighten the screw joints to avoid damage. During installation of the connection piping, make sure the pump is free of any forces, weight, vibration, and stress.

Installation of the suction piping

Güde GMP 7.21 - Installation of the suction piping - 1

The suction piping will transport the liquid to be pumped by the pump. Use the suction piping of diameter identical to pump suction connector. For pumping lift with the difference between the pump and the pumped liquid level of more than 4 12 , using of +1/4 " diameter is recommended.

A filter must be installed at the input of the suction piping to remove coarse impurities from water with potential of either clogging or damaging the pump.

In addition, it is highly recommended to install the return valve to prevent pressure leak after turning the pump off and protecting the machine against damage due to pressure surges. The return valve can be connected directly on the pump suction connector or the suction piping input. Installation on the suction piping input is favourable. The suction piping can be easily deaerated by filling with water.

The suction piping input must always be located at least 0.30 m under pumped liquid level to avoid air inlet. In addition to this, pay attention to sufficient distance of the suction piping from soil and streams, rivers, fishponds banks to avoid suction of stones, plants etc.

Installation of the force piping

The force piping transports the liquid to be pumped from the pump to the consumption point. To avoid losses from flow, using of the force piping of at least identical diameter as the pump connector is recommended.

Fixed installation

For fixed installation, attach the gasoline engine pump to a suitable stable supporting surface. To reduce vibrations, it is recommended to insert an anti-vibration material, e.g. rubber layer, between the pump and the supporting surface.

Commissioning

Installation and visual control

Güde GMP 7.21 - Installation and visual control - 1

Flue gases of the gasoline engine pump contain odourless toxic carbon monoxide that may result in serious health issues and death under extreme conditions. To protect humans and animals, the machine must not be used in poorly ventilated places and not in closed spaces. Generally, avoid breathing of the flue gases.

Güde GMP 7.21 - Installation and visual control - 2

Check the gasoline engine pump with respect to safety before use. Do not use the machine if damaged.

Güde GMP 7.21 - Installation and visual control - 3

The gasoline engine pump may only be used in areas without risk of floods.

For each starting of the machine, it is necessary to make sure the pump is installed safely and in a stable position. Always pay attention to a flat surface under the pump, otherwise the oil low level switch may be activated and starting is not enabled. The gasoline engine pump may only be used in areas without risk of floods.

Select the place of the pump installation so that no environmental damage is caused by leaked fuel or engine oil. If used in fish ponds, pits, construction pits, rivulets, streams and similar places, the pump must be secured against fall.

Check the gasoline engine pump visually before use of the pump. Pay attention to correct tightness of the bolts and perfect condition of all connectors. Do not use the machine if damaged.

Fuel and fuelling/engine oil

Güde GMP 7.21 - Fuel and fuelling/engine oil - 1

The gasoline engine pump is powered by gasoline. Use the fuel specified in the technical data applicable to your product.

Güde GMP 7.21 - Fuel and fuelling/engine oil - 2

Do not smoke and work with open flame when refuelling. Do not breathe vapours.

Güde GMP 7.21 - Fuel and fuelling/engine oil - 3

Gasoline and engine oil are toxic substances. Do not have gasoline or engine oil and do not breathe vapours. Many direct contact of gasoline and engine oil with skin, and clothes.

Do not refuel if the engine is running. Turn the pump off and let it cool for at least five minutes before refuelling. During refuelling, the machine must be placed on a flat surface in vertical position to avoid fuel leak. Refuel in well-ventilated area only. All leaked gasoline must be first cleaned and then start up the engine.

Do not smoke and work with open flame when refuelling. Do not breathe vapours.

Güde GMP 7.21 - Fuel and fuelling/engine oil - 4

Check oil level before use (see Replacement/check

Filling the pump with water or deaerating of the system

Pour water in the filling hole of the pump. Check for water leaks. Close the filling hole again to be airtight. It is recommended - but not absolutely necessary - to fill the suction piping with water as well.

The gasoline engine pump is self-suctioning device. It means that for starting, only the pump and not the suction piping must be filled. In either way, the pump will need some more minutes to draw the pumped liquid. Additional filling of the suction piping will significantly facilitate and fasten the first suction. If the suction piping is not filled with the liquid, it will be perhaps necessary to prime the pump several times with water. It depends on length and diameter of the suction piping.

Open potential closures in the force piping (e.g. water cock) to release air during suction.

Operation

Güde GMP 7.21 - Operation - 1

The gasoline engine pump must not be used with the y point closed.

Güde GMP 7.21 - Operation - 2

The pump must not be used without water for longer of time. Dry operation, i.e. without pumping of water, result in substantial damage of the machine.

Güde GMP 7.21 - Operation - 3

The gasoline engine pump and the piping system must be acted against freeze and weather conditions.

Güde GMP 7.21 - Operation - 4

Flammable substances and things, easily inflammable positive substances must be out of reach of the pump operation. Do not put anything on the engine.

Güde GMP 7.21 - Operation - 5

If the engine is in operation, do not refuel or pour oil in it. e pump off before refuelling.

Güde GMP 7.21 - Operation - 6

During operation, some parts of the engine pump - e.g. test or exhaust cover - are very hot. To avoid burning, touch the machine during operation and after turning it and cooling down on the designed points only - e.g. on issues and handles.

During first 20 hours of operation, the brand new engine must not be fully loaded. Operation at 2/3 of possible output performance is recommended. Full throttle operation is now permissible for short term only up to 10 minutes - e.g. for starting due to suction operation.

Decommissioning

Güde GMP 7.21 - Decommissioning - 1

Transport of the pump with the fuel tank filled is not approved.

Discharge water in the pump from the relevant discharge hole after use. Let the pump dry well to avoid damage due to corrosion. Water entrapped in the pump may cause damage if frozen.

If the device is transported, all fuel must be discharged. Transport of the pump with the fuel tank filled is not approved.

Care and maintenance

Güde GMP 7.21 - Care and maintenance - 1

If possible, turn the engine off, remove the spark plug shield and let the engine cool down before maintenance. If the engine must be on during maintenance, provide sufficient ventilation because the exhaust fumes are toxic.

Regular maintenance and diligent care reduce the risk of potential operation failures and contribute to improved lifecycle of your machine. The engines consist of the up-to-date technology and many rotary components exposed to substantial mechanic, thermal as well as chemical effect of environment and the combustion process. Use of correct, high quality and clean operation liquids - fuel and engine oil - is prevention against damage to the engine and operation failures.

Abrasive substances in the delivered liquid, such as sand, increase wear and tear and reduce total performance. Installation of a pre-filter is highly recommended for pumping of liquids with abrasive substances. The recommended accessories filter sand and other similar substances from the liquid effectively and reduce wear and tear and improve lifecycle of the pump.

Ignition plug

Cleaning of the ignition plug and correction of distances of the electrodes must be performed in six-month intervals or after 100 hours of operation. First, remove the ignition plug shield before maintenance of the ignition plug. Then, screw the ignition plug out using the ignition plug key. To ensure failure-free operation, the dry ignition plug without burnt residues must show distance of the electrodes 0.6 - 0.7 mm.

If necessary, clean the ignition plug. To remove the burnt residues, use a fine wire brush. Distance of the electrodes must be corrected by slight bending of the electrode. It is recommended to use a new ignition plug in case of strong accumulation or worn electrodes.

Checked, cleaned or a new ignition plug must be screwed first manually to stop. Then, tighten the ignition plug using the ignition plug key. Avoid excessive forces not to damage the ignition plug due to torque. Finally, slide the ignition plug shield back on the ignition plug.

Air filter

Güde GMP 7.21 - Air filter - 1

To clean the air filter, do not use gasoline or a thinner with low flash point in any case due to fire and explosion danger.

If the air filter is clogged, it prevents air flow to the carburettor. To avoid operation failures of the carburettor, air filter must be regularly checked and cleaned or replaced, if necessary.

Generally, checking of the air filter as far as clogging is concerned is recommended before use. Cleaning is required in three-month interval or after 50 hours of operation. When the pump is operated in dirty or dusty environment, cleaning must be performed in ten-hour intervals. Use a new air filter in six-month interval or after 300 hours of operation.

Open air filter cabinet and remove the air filter before maintenance. Wash the air filter with an inflammable thinner, if necessary - e.g. detergent. To clean the air filter, do not use gasoline or a thinner with low flash point in any case due to fire and explosion danger. Let the air filter dry after cleaning. Insert checked, cleaned or new air filter and close it again. Do never use the pump without the air filter to avoid increased wear and tear of the engine.

Replacement of the slide locking ring

The slide locking ring is the seal between the pump body and the engine shaft. The ring is a component with natural wear and tear.

If the slide locking ring is defective, water leaks between the engine and the pump body. Demount the pump body, manual starting device and the pump moving wheel. Then, the slide locking ring may be replaced. Finally, carefully mount the moving wheel of the pump, manual starting device and the pump body.

Removal of foreign particles from the pump

Coarser particles in the pumped liquid may block the pump body and the pump moving wheel. For this case, the pump body can be demounted in order to remove all impurities from the pump moving wheel.

Storing

If the machine is not used for longer time, all water in the pump must be drained. Let the pump dry to avoid corrosion. Drain the fuel tank and the carburettor. Cleaning and preserving of the machine before storing is recommended. Make sure the machine is stored in dry and frost-proof place.

Failures

Make sure no water gets in the machine.

Güde GMP 7.21 - Failures - 1

We shall not be liable for damage due to unprofessional repair attempts. Damage due to unprofessional repair attempts shall void any warranty claims.

All measures for removal of defects may be performed only if the engine is stopped.

The following list specifies some potential machine damages, potential reasons and tips for removal. All measures for removal of defects may be performed only if the engine is stopped. If you are unable to remedy the defect, please contact either the customer service or your sales representative. Overhaul repairs may be performed by authorized personnel only. Please note that warranty claims shall void in case of damage due to unprofessional repair attempts and we shall not be responsible for any consequent damage.

In case of operation failures, first check for operator error or other cause not associated with the machine defect - e.g. no fuel.

Service

Any technical questions? Complaint? Do you need spare parts or operation manual?

Go to our website www.guede.com and the section Service will help you quickly and without bureaucracy. Please, help us to help you. In order to identify your device in case of complaint, please indicate serial number, order number and year of manufacture. All information is available on the product label. To have all information always at hand, put them down.

Serial number:

Order number:

Year of manufacture:

Phone: +49 (0) 79 04 / 700-360

Fax: +49 (0) 79 04 / 700-51999

E-Mail: supp ort@ts.guede.com

Important information for the customer

Please be sure to know that returning the product in or after the warranty period must be made in the original packaging.

Maintenance table

DefectPossible cause Remedy
The pump does not pump or pumps too little of liquid, the engine runs.Too much liquid in the pump.Suction piping not sealing.Too low engine power selected.Suction piping input filter clogged.Suction piping deg.Pump moving wheel blocked by impurities.Too high suction lift/total head.Defective slide locking ring.Pump moving wheel not fitted correctly.Damaged pump moving wheel.Irregular engine operation.Pour liquid in the filling hole of the pump body.Tighten the suction piping and piping connectors with Teflon tape. Replace the suction piping if irreparable damage is detected.Increase engine powClean the efltClean the suction piping.Remove impurities.Change the installation so that the suction lift/total head does not exceed maximum value.Replace the slide locking ring.Place the pump moving wheel correctly.Replace the pump moving wheel.Contact the customer service.
Vibration or noisy operationToo high suction lift/total head.Foreign particle blocks the suction piping and/or the pump moving wheel.Unstable installatin.Unstable machine installation.Damaged pump moving wheel.Other technical defect.Change the installation so that the suction lift/total head does not exceed maximum value.Remove foreign particle.Stabilize the installation.Ensure stable position of the machine.Replace the pump moving wheel.Contact the customer service.
The engine does not start or turns off during operation.Low fuel.No ignition sparClogged carburettor.Clogged air filterOther technical defect.Open the gasoline cock and/or refuel.Check the ignition switch. Or check the ignition plugs.Clean the carbtor.Clean air filter.Contact the customer service.
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Güde

Model : GMP 7.21

Category : Pump