USER MANUAL HWW 6035 Güde

---- Translation of the original instructions Domestic water supply unit

natural_image Blue industrial air compressor with control panel and pressure gauge, no visible text or symbols on the device itself.

Güde HWW 6035 - 1

HWW 6035

93930

GÜDE GmbH & Co. KG

Birkichstrasse 6

74549 Wolpertshausen

Deutschland

Güde HWW 6035 - HWW 6035 - 1

Güde

®

Güde HWW 6035 - HWW 6035 - 2

ENGLISH Please read the instructions carefully before starting the machine.

natural_image Blue industrial air compressor with black pump and control panel, no visible text or symbols on the device itself.

DE Inbetriebnahme

PL Uruchomienie

GB Starting-up the machine

ES Puesta en marcha

FR mise en service

GB Cleaning / Maintenance

text_image > 0° | < 40°

Güde HWW 6035 - DE Inbetriebnahme - 1

text_image min. 400 mm

Güde HWW 6035 - DE Inbetriebnahme - 2

natural_image Blue industrial pump with black components and a red X symbol crossed out, set against a pattern of blue droplets (no text or symbols)

Güde HWW 6035 - DE Inbetriebnahme - 3

text_image Safety warning diagram showing a blue industrial machine with crosshair and warning symbols, indicating no need for installation or repair.

Güde HWW 6035 - DE Inbetriebnahme - 4

natural_image Gray gear icon with the number 1 in the center, no text or symbols present

Güde HWW 6035 - DE Inbetriebnahme - 5

text_image Safety warning sign showing a blue circular icon with a plug and a red prohibition symbol crossed out by a black tool.

Güde HWW 6035 - DE Inbetriebnahme - 6

text_image B A

Güde HWW 6035 - DE Inbetriebnahme - 7

text_image TIP KA 4 P / 94440 KA 7 P / 94441

Güde HWW 6035 - DE Inbetriebnahme - 8

text_image 1 A + B PTFE

Güde HWW 6035 - DE Inbetriebnahme - 9

text_image 2 A

Güde HWW 6035 - DE Inbetriebnahme - 10

text_image 3 4 3 2 1

Güde HWW 6035 - DE Inbetriebnahme - 11

text_image 4 2 3 1 SUB

Güde HWW 6035 - DE Inbetriebnahme - 12

text_image START 2 STOP

Güde HWW 6035 - DE Inbetriebnahme - 13

Güde HWW 6035 - DE Inbetriebnahme - 14

text_image 1 AUTOSTOP °C ↑

Güde HWW 6035 - DE Inbetriebnahme - 15

text_image 2 25 Min.

Güde HWW 6035 - DE Inbetriebnahme - 16

text_image 3 AUTORESTART ↑ °C

Güde HWW 6035 - DE Inbetriebnahme - 17

text_image START Gua

Güde HWW 6035 - DE Inbetriebnahme - 18

natural_image Blue Gudie air compressor with red X-shaped pipe connection (no text or symbols)

DE Die Pumpe darf in keinem Fall in trockenem Zustand laufen.
EN The pump must not in any case run without fillings.
FR La pompe ne doit en aucun cas tourner à sec.
IT In nessun caso la pompa deve essere in marcia a secco.
NL De pomp mag in geen geval in droge toestand draaien.
CZ Čerpadlo nesmí v žádném případě běžet nasucho.
SK Čerpadlo nesmie v žiadnom prípade bežat bez náplní.
HU A szivattyút tilos üresen üzemeltetni.
PL Pompa nigdy nie może pracować w stanie suchym.
ES La bomba no debe funcionar en seco bajo ninguna circunstancia.

Güde HWW 6035 - DE Inbetriebnahme - 19

Güde HWW 6035 - DE Inbetriebnahme - 20

natural_image Diagram of a blue Gudie air pump connected to a water tank with a pipe and warning symbol (no text labels)

Güde HWW 6035 - DE Inbetriebnahme - 21

text_image Diagram illustrating a physical setup with a red X-shaped object submerged in water, and a green checkmark indicating a 10 cm depth measurement.

Güde HWW 6035 - DE Inbetriebnahme - 22

text_image START 2 STOP

Güde HWW 6035 - DE Inbetriebnahme - 23

Güde HWW 6035 - DE Inbetriebnahme - 24

natural_image Diagram of a water pump system with control panel and water tank, no text or symbols present

Güde HWW 6035 - DE Inbetriebnahme - 25

text_image 1 I

Güde HWW 6035 - DE Inbetriebnahme - 26

text_image 2

Güde HWW 6035 - DE Inbetriebnahme - 27

text_image 3 AUTO-START bar 1,5 bar

Güde HWW 6035 - DE Inbetriebnahme - 28

natural_image Simple black-and-white diagram of a faucet with a circular component above it, no text or symbols present.

Güde HWW 6035 - DE Inbetriebnahme - 29

text_image 5 AUTO-STOP bar 3,0 bar

3

Güde HWW 6035 - 3 - 1

Güde HWW 6035 - 3 - 2

Güde HWW 6035 - 3 - 3

natural_image Diagram of a blue industrial air purifier with water tap and tubing, no text or symbols present

Güde HWW 6035 - 3 - 4

text_image 2 STOP GUB

Güde HWW 6035 - 3 - 5

natural_image Illustration of a blue industrial air compressor with attached piping and valve, no text or symbols present

Güde HWW 6035 - 3 - 6

text_image 4 X X

3

Güde HWW 6035 - 3 - 1

Güde HWW 6035 - 3 - 2

natural_image Close-up of a black industrial fan or compressor component with a white arrow pointing to its side panel (no visible text or symbols)

Güde HWW 6035 - 3 - 3

natural_image Industrial piping system with a blue SGBS air compressor and water tank (no text or symbols)

Güde HWW 6035 - 3 - 4

text_image 3

Güde HWW 6035 - 3 - 5

natural_image Blue industrial tank with pressure gauge connected to a stand, no visible text or symbols

Güde HWW 6035 - 3 - 6

text_image 5 1,5 - 1,8 bar

Güde HWW 6035 - 3 - 7

natural_image Blue industrial machine component with mechanical parts and a close-up inset showing a circular component (no text or symbols visible)

Technische Daten

Domestic water supply unit
HWW 6035
Art. No 93930
Service connection 230 V~50Hz
Rated input 600 W
Max. suction head 7 m
Max. head of delivery 35 m
Max. delivered quantity 3200 l/h
tank capacity 19 l
Max. Water temperature 35 °C
Degree of protection IPX4
Weight 10,3 kg

Güde HWW 6035 - 3 - 8

Güde HWW 6035 - 3 - 9

Read and understand the operating instructions before using the appliance. Familiarise with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.

The operator is responsible for accidents or risks to third parties.

In case of any doubts about connection and operation refer please to our customer center

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children without supervision.

Specified Conditions Of Use

The pump is designed for pumping clean water only to supply the home with water and to use it at home, in garden, courtyard and for fields. Respecting technical data and safety precautions.

Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.

Do not use pump at outside temperatures over 40 °C or under 0 °C

The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.

Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.

Do not use the pump for drinking water!

The pump must not be connected to the existing water-supply network as a pressure-boosting device.

⚠️ Never use the pump as a pool circulation pump.

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information: 1. Accident site, 2. Accident type, 3. Number of injured persons, 4. Injury type(s)

Symbols

Güde HWW 6035 - Symbols - 1

WARNING/CAUTION!

Güde HWW 6035 - Symbols - 2

WARNING - Read the operating instructions to reduce the risk of injury.

Güde HWW 6035 - Symbols - 3

Unplug the machine before any work on it.

Güde HWW 6035 - Symbols - 4

Cable pulling / transport prohibited

Güde HWW 6035 - Symbols - 5

Staying in the transportation medium prohibited

Güde HWW 6035 - Symbols - 6

Warning against dangerous electric voltage

Güde HWW 6035 - Symbols - 7

Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.

Güde HWW 6035 - Symbols - 8

CE marking

Safety Instructions

Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!

Unplug the device prior to submersion, upon termination of operation, in the course of defect removal and prior to performing maintenance procedures.

If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).

The temperature of the drained liquid must not exceed +35 °C.

The pump must not in any case run without fillings.

Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.

If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.

The user is responsible to third parties if pump (dumping stations, etc.) is used.

Check the cable and/or socket for damages before the appliance putting into operation.

Do not expose the appliance to rain and do not use it in wet or moisture conditions.

Avoid installing the appliance in wet shafts (risk of short circuit, corrosion effects)!

When using the pump for domestic water supply, always observe the local regulations of water management authorities and the waste water drainage.

In cold weather, the pumping body motor should not be wrapped in a blanket or another piece of textile with intent to prevent the water freezing.

Mains Connection

Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).

⚠ WARNING! Electric shock! There is a risk of an injury caused by electric shock!

Before putting into operation, a qualified electrician must check whether electric safety measures required are in place. Any national regulations in this regard must be complied with.

Electric connection to a socket.

Check the voltage. Technical data given on the type label must correspond with electric network voltage.

It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.

Only use splash proof extension cables approved for outdoor purposes.

Protect the feeder cable from excessive temperatures, oil and sharp edges.

Maintenance

⚠️ Unplug the machine before any work on it.

Before using the appliance, perform a visual inspection at all times to make sure the power cord and the plug, in particular, are not damaged on the charger.

The appliance must not be used if damaged or safety equipment is defective. Replace any worn-out and damaged parts.

Caution! If the power cord of the appliance gets damaged, it must be replaced by the manufacturer or its customer service or a similarly qualified person to avoid danger.

Repairs and works specified in these Instructions may only be performed by qualified authorised staff.

Use only original accessories and original spare parts.

Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.

To ensure long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals.

At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil).

If necessary, a list of spare parts can be found at www.guede.com.

Guarantee

Warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device.

The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.

The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.

The device has to be checked on a regular basis to ensure perfect functioning.

Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases:

Unprofessional repairs executed by unauthorised service centres;

- Use in conflict with the designed purpose, or failure to observe the use as designed;

- Pump overload with a continuous run;

- Damage as a result of icing or any other fault caused by climatic influences;

Identical regulations apply for accessory parts.

To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).

Important information for the customer

Please be sure to know that returning the product in or after the warranty period must be made in the original packaging.

Service

Do you have any technical questions? Do you have a complaint? Do you require spare parts or an operating manual? You can get quick and unbureaucratic assistance in the Service section on the homepage of our service partner Güde GmbH & Co. KG (www.guede.com). Please help us to help you. In order to be able to identify your device in the case of a complaint, our service partner will require its serial number, article number, and year of manufacture. All this information can be found on the nameplate.

Tel.: +49 (0) 79 04 / 700-360

Fax: +49 (0) 79 04 / 700-51999

E-Mail: support@ts.guede.com

Inspection and maintenance plan

Time interval Description Any other details

As needed Clean the check valve. Check the check valve function.

Failure removal

Failures Causes Removal

Engine does not start No power supply. Blocked pump wheelTurn the engine shaft with screwdriver through the fan cover (to release friction circles sealing that may be stuck together).
Pump does not suck Missing, loose or blocked check valve Check valve is not in water. No water in the pump shell. Too high suction head. Air bubbles in the suction pipeline. Connections not sealed, pump sucks air, pump is not deaerated.Fix or clean the check valve. Immerse the check valve into water. Fill the pump shell with water. Check the suction head. Check the tighten of suction pipeline.
Thermal detector switching the pump offPump is overheated and switched off by the thermal overloading protection. No electric power supply. Impurity particles (e.g. pebbles) have settled down in the suction hole.Let the device getting cool! Check power supply. Disassemble and clean the suction hose, prevent from suction of foreign substances.
Insufficient amount of water pumpedToo high suction head. Strainer of the check valve dirty Water level quickly drops downCheck the suction head. Clean the strainer., Position the check valve lower. Clean the pump and replace worn parts. (qualified workshop)