USER MANUAL Aroma Spring LANAFORM
text_image
Aroma diffuserFountain and fragrance diffuser
text_image
Technical diagram of a mechanical device with numbered components for identificationFIGURE 2

INSTRUCTIONS FOR USE
Thank you for choosing the Lanaform® Aroma Spring. The Aroma Spring interior fountain will bring serenity and well-being to your home thanks to its calming circulation of water. It will also disperse cold scented mist and will project colourful light throughout your home.
PLEASE READ ALL THE INSTRUCTIONS BEFORE USING YOUR FOUNTAIN, ESPECIALLY THIS BASIC SAFETY INFORMATION:
- The Aroma Spring is an interior fountain. Always place it on a hard, flat, horizontal surface inside your home. Always keep it away from walls and heat sources such as stoves, radiators, etc.
Caution: if it is not placed on a horizontal surface, the Aroma Spring fountain may not work properly.
- Check that your mains voltage is the same as that of your device.
- Do not connect or disconnect the plug of the appliance with wet hands.
- If the power cable is damaged, it must be replaced by a similar cord available from the supplier or the latter's after-sales department.
- Do not leave the device exposed to sunlight for long periods.
- Do not take apart either the device as a whole.
- Do not switch on the device when there is no water in the reservoir.
- Do not lift the glass dome when the fountain is working. If you notice a strange smell or sound, turn the device off immediately and consult the section «breakdowns and remedies» in these instructions. If the problem continues, have the device examined by the supplier or its after-sales department.
- Do not use essential oils that are not recommended for diffusion. To find out which essential oils are recommended, consult the advice provided in these instructions for use.
- Do not use perfume or synthetic essences as these could damage the device.
- Unplug the device before cleaning it.
- Do not wash the entire unit with water and do not immerse it in water. Consult the cleaning instructions in this manual.
- Never scrape the transducer with a hard tool; consult the cleaning advice in these instructions.
• The device should be used preferably for 30 minutes at a time, but can be used several times a day if you wish.
- This equipment is not intended for use by people, including children, with limited physical, sensory or mental abilities, or by people lacking experience or knowledge, unless they are supervised or have been instructed beforehand on how to use the equipment by someone responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
COMPONENTS (SEE THE ILLUSTRATIONS, FIGURE 1):
(1) Water circulation
(2) Glass dome
(3) Silicon tube
(4) Reservoir
(5) Pump
(6) Transducer
(7) LED lights
(8) M button (mist): fragrance option
(9) W button (water): fountain option
(10) Water level indicator
INSTRUCTIONS FOR USE
FEATURES:
- Changing colours
- Capacity of 350 ml
• 1.5 hours of continuous diffusion - Easy-to-fill water reservoir
• The fountain stops automatically when there is no more water left in the reservoir
FUNCTIONALITIES:
- Interior fountain
• Essential oils diffuser - Eliminates electrostatic charges
- Improves ambient air quality
INSTRUCTIONS (SEE ILLUSTRATIONS, FIGURE 2):
- Place the fountain in the room half an hour before turning it on, on a flat surface, so that it can adjust to room temperature (a).
- Ensure that the fountain is clean.
- Connect the reservoir to the glass dome using the silicon tube (b). This tube should be connected to the pump. Ensure that the two ends of the tube are properly connected to the pump and to the glass dome (c).
- Fill the reservoir with a maximum of 350 ml clean water (the pump must be submerged). The water temperature must not be more than 40^ (d).
- Pour two or three drops of essential oils in the reservoir (e).
- Place the dome over the reservoir, making sure that it has been correctly positioned on the designated notches (f and g).
- Connect the plug, with dry hands (h). The fountain is ready to use.
Functionalities of the fountain:
M button «fragrance option»:
Press once; the mist dispersal and the light effects will start to work. Press again and the system will turn off completely.
W button «fountain option»:
If you want the two functions to run simultaneously, press on button M and then on button W. The circulation of water, the mist and the projection of colours will create the perfect environment for relaxation.
EN
Important notes:
- Only use clean and fresh water, preferably water that has been boiled and cooled.
- Do not move or refill the reservoir when the fountain is working.
- If the water flow is not sufficient, adjust this using the button on the pump (Figure 2 (i)).
- When there is no more water in the reservoir the water level indicator will turn red. Refill your fountain.
- Caution: EVEN THOUGH THERE IS A SAFETY DEVICE THAT STOPS THE TRANSDUCER WORKING, DO NOT LEAVE THE DEVICE CONNECTED WHEN YOU ARE NOT USING IT.
ADDITIONAL INFORMATION RELATING TO THE USE OF ESSENTIAL OILS
- Before using the essential oils, please check the harmful effects that use of these products may have on your health.
- Always choose quality essential oils that are pure, 100% natural and intended for diffusion. Use them in moderation and with care. Follow the instructions and warnings stated on the packaging of the essential oils, in particular by ensuring that:
- Pregnant women, people with epilepsy, asthmatics and people suffering from allergies and those with heart problems or serious illnesses do not use essential oils.
- Essential oils should only be used for periods not exceeding 10 minutes in a baby's room (under 3 years old) and only when the baby is not actually in the room.
- Make sure that children and minors do not play with and use the device.
- Just a few drops (3 to 4 drops at most) of essential oils are sufficient to ensure that the device works properly and the scent is being diffused. Excessive use of essential oils could damage the device.
- First pour water in the reservoir, then add a few drops of essential oils.
- Lanaform ^® cannot be held liable in the event of accidental damage resulting from any use contrary to the instructions given in this manual.
MAINTENANCE AND STORAGE
If the water contains too much calcium and too much magnesium, it may deposit a "white powder" in the device. If this foam is deposited on the transducer (ceramic ring emitting ultrasounds, Figure 1 (6)), this will prevent the device from working properly.
We recommend:
1) Using water that has been boiled and cooled each time it is used.
2) Cleaning the reservoir every 2 days and cleaning the transducer every week.
3) Changing the water in the reservoir every 2 days.
4) Cleaning the device (see explanations below) and making sure that all its parts are completely dry when it is not in use.
To clean the transducer (Figure 1 (6)):
1) Put 2 to 5 drops of vinegar on its surface and leave them there for 2 to 5 minutes.
2) Brush the foam off the surface with a soft brush. Do not use a hard tool to scrape the surface.
3) Rinse the reservoir of the base in clean water.
4) Do not use soap, solvent or spray cleaner to clean the transducer.
To clean the reservoir:
1) Clean the reservoir with water using a soft cloth and vinegar if there are foam or limescale deposits on the inside.
2) Rinse the reservoir in clean water.
To clean the silicon tube:
1) Rinse the tube in clean water. Use a few drops of vinegar if there are limescale deposits.
2) Wipe with a soft cloth.
Storage:
After cleaning and drying the device, store it in a dry, cool place out of the reach of children.
BREAKDOWNS AND REMEDIES
In the event of a malfunction, under normal conditions of use, please refer to the following chart:
| BREAKDOWNS POSSIBLE CAUSES REMEDIES | ||
| No mist. If there is no light. Check that | the device is connected | and no breakdown has occurred in that area. |
| No more water in the reservoir. Add water to the reservoir. | ||
| The dome is badly positioned. Reposition it correctly. | ||
| The temperature of the reservoir is too low. | Place the reservoir in a room at ambient temperature for half an hour prior to use. | |
| Mist has an unusual smell. The water has been standing in the reservoir too long. | Clean the reservoir and pour fresh water into it. | |
| Low intensity. Too much/little water in the reservoir. | Empty the water out of the reservoir or add water to it. | |
| Transducer. | ||
| At room temperature. | ||
| Clean the reservoir and pour fresh water into it. | ||
| The water does not come out of the fountain. | The silicon tube is not positioned correctly. | Ensure that the tube is correctly positioned on both sides. |
| The intensity level of the water is low. | Increase the intensity level on the pump. | |
| There are sediments in the tube. Clean the silicon tube. | ||
ADVICE REGARDING THE DISPOSAL OF WASTE

- All the packaging is composed of materials that pose no hazard for the environment and which can be disposed of at your local sorting centre to be used as secondary raw materials. The cardboard may be disposed of in a paper recycling bin. The packaging film must be taken to your local sorting and recycling centre.
- When you have finished using the device, please dispose of it in an environmentally friendly way and in accordance with the law.
LIMITED WARRANTY
LANAFORM® guarantees this product against any material or manufacturing defect for a period of two years from the date of purchase, except in the circumstances described below.
The LANAFORM ^® guarantee does not cover damage caused as a result of normal wear to this product. In addition, the guarantee covering this LANAFORM ^® product does not cover damage caused by abusive or inappropriate or incorrect use, accidents, the use of unauthorized accessories, changes made to the product or any other circumstance, of whatever sort, that is outside LANAFORM ^® 's control.
LANAFORM® may not be held liable for any type of circumstantial, indirect or specific damage.
All implicit guarantees relating to the suitability of the product are limited to a period of two years from the initial date of purchase as long as a copy of the proof of purchase can be supplied.
On receipt, LANAFORM ^® will repair or replace your appliance at its discretion and will return it to you. The guarantee is only valid through LANAFORM ^® 's Service Centre ^® . Any attempt to maintain this product by a person other than LANAFORM ^® 's Service Centre will render this guarantee void.
The photographs and other images of the product in this manual and on the packaging are as accurate as possible, but do not claim to be a perfect reproduction of the product.