Brand CADAC
Model 2cook Classic
Product Type Gas cooker
Fuel Butane/propane gas (LPG), pressure 28-30 mbar (or 37/50 mbar depending on country)
Nominal Power 4.0 kW (4.4 kW for some countries)
Gas Consumption 291 g/h (320 g/h for some countries)
Vessel Diameter 180 mm to 250 mm (recommended 150-300 mm)
Safety Distances Above: 1.2 m; sides/back: 600 mm
Intended Use Outdoors only
Standards BS EN 484:2019, SANS 1539:2017
Assembly and Setup Approved hose and regulator required (supplied in South Africa)
Maintenance and Cleaning Clean after each use with a damp cloth; do not immerse in water; clean burners with a brush
Safety Leak detection with soapy water; do not use indoors without ventilation; turn off gas if odor is detected
Spare Parts Nozzles, gaskets, hoses, burners; use only genuine CADAC parts
Warranty Taps: 2 years; enamel parts: 2 years; burners: 1 year; plastic: no warranty

Frequently Asked Questions - 2cook Classic CADAC

Where to use the CADAC 2cook Classic?
This gas cooker must be used exclusively outdoors, in a well-ventilated area, away from any flammable materials.
What gas cylinder to use?
Use a 3 kg, 5 kg or 7 kg LPG (butane/propane) cylinder with a suitable regulator. For a 9 kg cylinder, a specific hose and regulator are required.
How to ignite the appliance?
First light a match or barbecue lighter, then turn the control knob anti-clockwise. If the burner does not ignite within 10 seconds, turn off the gas, wait 3 minutes before trying again.
What to do in case of a gas leak?
Immediately close the cylinder valve, then the appliance valve. Take the appliance to a ventilated area without flame. Check for leaks with soapy water (bubbles indicate a leak). If the leak persists, contact your CADAC distributor.
How to clean the cooker?
After use, clean the body with a damp cloth and detergent. Never immerse in water. Clean the burners with a brush. Avoid abrasive cleaners.
What to do if the burner does not heat enough?
Check that the cylinder contains gas, the nozzle is not blocked, and the burner tube is clean. Also inspect for spider webs in the air inlet.
How to replace a nozzle?
Turn off the gas, disconnect the cylinder. Remove the vessel support and cooking surfaces. Disassemble the burner and unscrew the blocked nozzle with a suitable wrench. Replace with a new one without overtightening.
What regular maintenance is needed?
Before each use, check the condition of the hose and the regulator gasket. Inspect for leaks with soapy water. After use, clean the appliance and store it in a dry place, preferably in a plastic bag.
How to store the appliance?
Handle with care, do not drop. Place it in a plastic bag to prevent dirt and insects from entering. Store unconnected LPG cylinders outdoors, away from the appliance.
What safety distances must be observed?
The appliance must be placed at least 1.2 m above and 600 mm to the sides and back from any flammable material. Always use on a stable, horizontal surface.

User questions about 2cook Classic CADAC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Cooker in PDF format for free! Find your manual 2cook Classic - CADAC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 2cook Classic by CADAC.

USER MANUAL 2cook Classic CADAC

Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation must be provided.

IMPORTANT

Read these instructions carefully so as to familiarise yourself with the appliance before fitting the appliance to a gas cylinder.

Retain these instructions for future reference.

1. General

  • This is an economic gas appliance designed for an optimal cooking experience using environment friendly LP gas.
    The appliance conforms to BS EN 484:2019 and SANS 1539:2017
    This appliance may only be used with an approved hose and regulator (A 2.8kPa hose and regulator supplied with this unit in South Africa)
    Note that figures in this user manual are shown for visual purposes only and may differ to your appliance.
  • Please read all the instructions and warnings on the appliance before use.
  • It is important that all gas connections have been correctly connected to prevent any gas leaks.
  • Do not use a leaking, damaged or malfunctioning appliance.
  • This appliance requires a hose and regulator to operate.
  • Ensure that the appliance is used in a well-ventilated area.
  • Handle the appliance with care, do not drop it.
  • When using a pot, the minimum recommended pot size is 150mm and maximum pot size is 300mm .
  • The gas cylinder is to be used in an upright position only.
  • Read the instructions before using the appliance.
  • For outdoor use only!

2. Safety information

These instructions are for your safety and to help you avoid risk of injury and/or damage. All warranties will become void if you do not follow these instructions.

  • The hose and seal on the regulator must be checked for wear or damage before every use and before connecting to the gas cylinder.
  • In the event of light back (where the flame burns back and ignites at the jet) immediately turn off the gas supply by first closing the control valve onthe gas cylinder and then the appliance valve. After the flame is extinguished remove the regulator and check the condition of its seal, replace the seal if in doubt. Re-light the appliance. Should the flame persistently light back again return the product to your authorised CADAC repair agent.
  • Ensure the appliance is used away from flammable materials. Minimum safe distances; above the appliance 1.2m , at the rear and sides 600mm .
  • Do not use an appliance that is leaking, damaged or which does not operate properly.
  • Ensure that the gas cylinder is fitted or changed in a well-ventilated location, preferably outdoors, away from any sources of ignition, such as naked flames and away from other people.
  • Keep gas cylinders away from heat and flame. Do not place on a stove or any other hot surface.
  • Ensure that the assembled product is stable and does not rock.
  • Never leave the appliance unattended when lit.
  • If there is a leak on your appliance (smell of gas), turn off the gas supply, firstly at the gas cylinder and then on your appliance by turning the respective knobs fully clockwise. Take them outside immediately into a well-ventilated flame-free location where the leak may be detected and stopped.
  • This appliance consumes oxygen and needs ventilation for optimum performance and for safety of those in close proximity.
  • Room ventilation is important for the efficient performance of the appliance and for the safety of the occupants in the room.
  • The room where this appliance is used should have a window or a door that can be opened or partially open during use. If there is no window or door available for room ventilation, extra ventilation must be installed for your safety.
    If you wish to check for leaks on your appliance, do it outside. Do not try to detect leaks using a flame, use soapy water. The correct way is to smear the joints with soapy water. If bubbles form then there is a gas leak. Immediately turn off the gas supply first by closing the control valve on the gas cylinder and then the appliance valve, check that all the connections are properly fitted. Re-check with soapy water. If a gas leak persists return the product to your CADAC dealer for inspection / repair.
  • Do not modify the appliance. Do not use it for anything for which it has not been designed.
  • During use, parts of the appliance will become hot (particularly the burner) Avoid touching hot parts with bare hands. The use of gloves is recommended.
  • Keep young children away from the appliance at all times.
  • Do not twist or pinch the hose.
  • Do not move the appliance during use.
  • Do not use the appliance without the Potstands being in place and properly located.
  • Turn off the gas supply at the gas container after use.
  • Do not modify the appliance, any modification may be dangerous.

CADAC 2cook Classic - Safety information - 1

CADAC 2cook Classic - Safety information - 2

Country of UseBE, CH, CY, CZ, ES, FR, GB, GR, IE, IT, LT, LU, LV, PT, SK & SIPLBE, CY, DK, EE, FR, FI, HU, IT, LT, NL, NO, SE, SI, SK, RO, HR, TR, BG, IS, LU, MT, & ZAAT, CH, DE & SK
Appliance Catagories I3-(28-30/37)13B/P (37)13B/P (30)13B/P (50)
Allowable gasses Butane-30 Propane-31 Butane-30Propane-31 or theirmixture
Gas Pressure 28-30mBar 37mBar37mBar28-30mBar (2.8kPa for South Africa)50mBar
Jet Number 0.710.710.71 0.62
Nominal Usage291g/hr 320g/hr 291g/hrhr 291g/hr
Gross nom. heat input4.0kW 4.4kW4.0kW4.0kW
Country Name and Abbreviations
AE = United Arab EmiratesAL = AlbaniaAT = AustriaBE = BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = SwedenTR = Turkey ZA = South Africa

3. Assembly Instructions

  • PLEASE NOTE: Please ensure all protective packaging and plastic are removed from the appliance before use.
    This appliance may only be used with an approved hose and regulator (hose and regulator supplied with this unit in South Africa)
  • Connect the regulator to a CADAC 3kg, 5kg or 7kg LPG cylinder prior to use.
    If you wish to use the appliance with a 9kg cylinder, please ensure that you have purchased the correct hose and regulator suitable for a 9kg cylinder.
  • The hose length should be no less than 600mm and shall not exceed 1.2m and replace when the hose is damaged or shows signs of brittleness or cracks.
  • Do not twist or pinch the hose. Ensure that it is routed away from the Stove Body so as to prevent deterioration / damage to the hose caused by heat.
  • Ensure that the appliance valves are in the off position by turning the knobs fully clockwise to the stop.
  • Open the gas valve on the cylinder and test for any leaks.
  • Check all gas connections for any signs of gas leaks.
  • Your appliance is now ready to be used.

I 3B/P (30), I 3+ (28-30/37) and I 3B/P (37), Appliance categories: (DK, FI, NO, NL, SE, AT, DE, BE, ES, FR, IE, IT, PT, GB, CH)

Push an approved hose onto the valve tailpiece until it is properly seated. On the other end, attach a suitable low pressure regulator.

13B/P(30) : 30mbar Butane configurations regulator or 30mbar Propane configurations regulator.

13B/P(37) : 37mbar Butane configurations regulator or 37mbar Propane configurations regulator.

13+(28-30/37) : 30mbar Butane configurations regulator or 37mbar Propane configurations regulator.

Again making sure that the hose is properly seated. The type of hose used shall comply with the relevant EN standard and locate requirement. In South Africa the regulator used must comply with SANS 1237.

1 3B/P (50) Appliance category: (AT, DE)

13B/P(50) : 50mbar Butane configurations regulator or 50mbar Propane configurations regulator or 50mbar butane/propane mixture configurations regulator.

Screw a hose with the correct threaded fittings on each end, onto the left hand 1/4" BSP thread of the valve. Attach a suitable 50mbar low-pressure regulator on the end of the hose. The hose assembly used must comply with DIN 4815 part 2 or equivalent.

Product Code:202MO-10N

CADAC 2cook Classic - Assembly Instructions - 1
Product Code: 202M0-20

CADAC 2cook Classic - Assembly Instructions - 2

Product Code: 202M0-10

CADAC 2cook Classic - Product Code: 202M0-10 - 1

4. Fitting and Changing the Gas Cylinder

Before connecting the appliance to a gas cylinder, ensure that the rubber seal on the Regulator is in position and in good condition.
- Carry out this check each time you fit the appliance to a gas cylinder.
- Blow out any dust from the cylinder opening to prevent possible blockage of the jet.
- Ensure that the appliance valves are in the off position by turning the knobs fully clockwise to their stop.
- Ensure that the gas cylinder is fitted or changed in a well-ventilated location, preferably outdoors, away from any source of ignition, such as naked flames and away from other people.
Make sure that the gas cylinder is kept upright at all times, connect to the cylinder by screwing on hand tight until fully engaged.
- Ensure that a complete gas seal has been made (check for the smell of gas around the connection joint). If there is a leak on your appliance (smell of gas), take it outside immediately into a well-ventilated flame free location where the leak may be detected and stopped. To check for leaks on your appliance, do it outside using warm soapy water only, which is applied to the joints and connections of the appliance. A formation of bubbles will indicate the gas leak. Do not check for leaks with a naked flame.
If you cannot rectify the gas leak do not use the appliance, contact your local CADAC stockist for assistance.
- CADAC gas cylinder valves must only be repaired by an authorised CADAC service centre or dealer.
- When changing a gas cylinder firstly close the appliance control knobs and then the cylinder valve, making sure the flame is extinguished, unscrew the regulator. Re-fit the regulator to a full cylinder following the same precautions as described above.

5. Operating the Appliance

The appliance is designed for use with cooking vessels of not less than 180mm in diameter and not greater than 250mm in diameter.

After lighting, do not move the gas cylinder and the appliance around, as liquefied gas may enter the appliance from the gas cylinder, causing it to flare (large yellow flames).

Always operate the appliance on a firm level surface with the gas cylinder in an upright position.

Warning: If the burner fails to ignite within 10 seconds, turn the control knob off (clockwise). Wait three minutes before attempting to re-light with ignition sequence.

Lighting the Appliance with a match:

To light the appliance, light a match or barbecue lighter, turn on the appliance valve after connecting to and opening the cylinder valve, by turning the control knob (E) in an anti-clockwise direction. Light the appliance burners.
Use the control knob to adjust the flame intensity to the desired level by turning the knob clockwise to decrease the flame and anti clockwise to increase it.
- Always light the match or the lighter first before opening the gas valve on the appliance.

6. General Maintenance

This appliance does not require scheduled maintenance.

It is dangerous to use an appliance with a cracked or perished seal and / or hose. Inspect both seals and hose regularly and replace if they are not in order, before using the appliance.
If the appliance was in use, it will be hot. Allow to cool sufficiently before attempting any maintenance.
- The Stoves are fitted with jets to regulate the correct amount of gas.
- Should the hole in the Jet become blocked this may result in a small flame or no flame at all.
- Do not attempt to clean the jet with a pin or other such device as this may damage the orifice, which could make the appliance unsafe.

Replacing a blocked jet:

  • Ensure that the cylinder valve is closed, then disconnect the appliance from the gas cylinder.
  • Remove the Potstand/cooking surfaces from the stove body.
  • Turning the appliance upside down, unscrew the screws holding the bracket of the burner to the body.
  • From the top now, you can safely remove the burners from the appliance.
  • Unscrew the blocked jet from the valve with a suitable spanner and replace it with a new jet.
  • Do not over tighten as this may damage the Jet. To re-assemble, reverse the above procedure.
  • Do not use pliers on the jet as this may damage the jet making it unusable or impossible to remove.

7. Troubleshooting

  • A normal flame is blue and may have a yellow tip. If the flame is completely yellow, it may be that the jet is not securely fitted. Retighten the jet to give a gas tight seal. An overfilled gas cylinder can also cause large yellow flames. Cylinder should be returned to filling station and checked by weight.
  • Check that the inlet to the burner pipe is clear and free of obstructions.
    If the flame power drops or the gas will not light, check that the gas cylinder still contains gas (shake to hear the noise made by the liquefied gas). If there is still gas, the jet might have become blocked or partially blocked.
    If you suspect a blocked jet, follow the instructions above.
  • Check for spider webs or insect nests in the gas tube or primary air inlet.

8. Cleaning

It is recommended to clean your appliance after every use. This will prolong the life of your appliance.
- The Potstand is removed by lifting it from the stove top and can be washed in a detergent solution.
To clean the stove body, simply wipe with a damp cloth using a little detergent, if necessary.
DO NOT IMMERSE IN WATER as this will allow water to get into the burner tube causing the appliance to malfunction.
- Do not use abrasive cleaners or scourers as this will cause permanent damage to the surface.
- To avoid ignition failure, keep the burners clean.
- Use a brush to clean the burners.
- A tooth brush may be used to clean out the venturi should there be any obstacles within the venturi.

9. Storage

  • Handle the appliance with care. Do not drop it.
    After use, wait until the appliance has cooled down, disconnect it from the gas cylinder and store them in a cool dry place. Store your cylinder in a well-ventilated place.
    It helps to place the appliance in a plastic bag when not in use as this will prevent the ingress of dirt and insects, which may affect the gas flow.
  • Warning: An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
  • LPG cylinders should preferably be stored outdoors if not in use.

10. Spares

Always use genuine CADAC spares as they have been designed to give optimum performance.

CADAC 2cook Classic - Spares - 1

11. Returning the Appliance for Repair or Service

  • Do not modify the appliance. Any modification of the appliance may be dangerous.
  • Any modifications will render the CADAC warranty null and void.
    If you cannot rectify any fault by following these instructions, contact your local CADAC distributor for inspection/repair

12. Warranty

CADAC (Pty) Ltd hereby warrants to the ORIGINAL PURCHASER of this CADAC gas appliance for 2 years, that it will be free of defects in material and workmanship from the date of purchase as follows:

Valves:

2

Years

Plastic parts: No Warranty

Enamel parts: 2 Years

Cast Iron: 2 Years

Burners:

1

Year

The warranty will only apply if the unit is assembled and operated in accordance with the printed instructions.

CADAC may require reasonable proof of your date of purchase. THEREFORE, YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE.

This Limited Warranty shall be limited to the repair or replacement of parts that prove defective under normal use and service and which on examination shall indicate, to CADAC's satisfaction, they are defective. Before returning any parts, contact the customer service representative in your region using the contact information provided with your manual. If CADAC confirms the defect and approves the claim, CADAC will elect to replace such parts without charge. CADAC will return parts to the purchaser, freight or postage prepaid.

This Limited Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, misapplication, vandalism, improper installation or improper maintenance or service, or failure to perform normal and routine maintenance, including but not limited to damage caused by insects within the burner tubes, as set out in this owner's manual. Deterioration or damage due to severe weather conditions such as hail, hurricanes, earthquakes or tornadoes, discoloration due to exposure to chemicals either directly or in the atmosphere, is not cover by this Limited Warranty.

There are no other express warrants except as set forth herein and any applicable implied warranties of merchantability and fitness are limited in duration to the period of coverage of this express written Limited Warranty. Some regions do not allow limitation on how long an implied warranty lasts, so this limitation may not apply to you.

CADAC is not liable for any special, indirect or consequential damages. Some regions do not allow the exclusion or limitation of incidental or consequential damages, to this limitation or exclusion may not apply to you.

CADAC does not authorize any person or company to assume for it any obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment; and no such representations are binding on CADAC.

This Warranty applies only to products sold at retail.

To enjoy and ensure longevity of your CADAC product, please refer to the cleaning and maintenance section of the user manual with particular attention to the care of the Stainless Steel.

VORSICHT

Country Name and Abbreviations
AE = United Arab EmiratesAL = AlbaniaAT = AustriaBE = BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = Sweden TR = TurkeyZA = SouthAfrica

3. Montageanleitung

Country Name and Abbreviations
AE = United Arab EmiratesAL = AlbaniaAT = AustriaBE = BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = SwedenTR = TurkeyZA = South Africa
Country Name and Abbreviations
AE = United Arab EmiratesAL = AlbaniaAT = AustriaBE = BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = Sweden TR = TurkeyZA = SouthAfrica
Country Name and Abbreviations
AE = United Arab EmiratesAL = AlbaniaAT = AustriaBE = BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = SwedenTR = TurkeyZA = South Africa

3. Samleinstruktion

Country Name and Abbreviations
AE = United Arab EmiratesAL = AlbaniaAT = AustriaBE = BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = SwedenTR = TurkeyZA = South Africa
Country Name and Abbreviations
AE = United Arab EmiratesAL = AlbaniaAT = AustriaBE = BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = SwedenTR = TurkeyZA = South Africa
Country Name and Abbreviations
AE = United Arab EmiratesAL = AlbaniaAT = AustriaBE = BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = SwedenTR = TurkeyZA = South Africa
Country Name and Abbreviations
AE = United Arab Emirates AL= Albania AT = Austria BE= Belgium CH = Switzerlandland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = SwedenTR = TurkeyZA = South Africa
Country Name and Abbreviations
AE = United Arab EmiratesAL = AlbaniaAT = AustriaBE = BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = Slovakia SE = SwedenTR = TurkeyZA = South Africa
Ime kartice države
AE = United Arab Emirates A= Albania AT = Austria BE= BelgiumCH = Switzerland
CZ = Czech RepublicDE = GermanyDK = DenmarkES = SpainFI = Finland
FR = FranceGB = United KingdomGR = GreeceHR = CroatiaIT = Italy
JP = JapanKR = KoreaNL = NetherlandsNO = NorwayPL = Poland
PT = PortugalRO = RomaniaRU = RussiaRS = SerbiaSI = Slovenia
SK = SlovakiaSE = SwedenTR = Turkey ZA = South Africa

Email: info@cadac.co.za

www.cadacinternational.com

CADAC UK

14 Deanfield Court,

Link59 Business Park,

Clitheroe, Lancashire,

BB71QS

United Kingdom.

Tel: +44 (0) 333 2000363

E:mail:info@cadacuk.com

www.cadacinternational.com

CADAC MOZAMBIQUE

Exclusive Brands Africa

492 Avenida Namaaacha

Maputo, Mozambique

Tel: +258 21 406254

www.cadac.co.mz

CADAC IRAN

Robin Bazarganan Carin Co.

Unit D, 6th Floor, Negin Zafar

Building, No.1327

Shariati Street, Tehran, Iran

Tel: +98 21 276 00 781

Mail: info@cadac.ir

CADAC CHINA

Room 807, Huayue International

Building, No.255 Tiangao Road,

South

Yinzhou business district,

Ningbo, China

Tel:+8657487723937

Email: info@cadac.com.cn

CADAC SWEDEN & NORWAY

KAMA FRITID AB

004636353700

info@kamafritid.se

CADAC EUROPE

Ratio 26, 6921 RW Duiven

The Netherlands

Tel: +31 26 319 7740

Email: info@cadaceurope.com

www.cadacinternational.com

CADAC SCANDINAVIA

Millarco International A/S

Rokhoj 26

8520 Lystrup, Denmark

Phone: +45 87 43 42 00

millarco@millarco.dk

www.millarco.com

CADAC MONTENEGRO

City kvant Z1L6

81000 Podgorica, Montenegro

Tel 38220671446,

38269020063

E-mail: coca@t-com.me

CADAC DENMARK

Camper Fritid

Industrivej 11

6640 Lunderskov, Denmark

Tel.: +45 7558 5255

Email: info@camper.dk

www.camper.dk

CADAC ZIMBABWE

Exclusive Brands Africa

Unit 8 Birkenhead Park

43 Josiah Chinamano Street

Belmont, Bulawayo

Tel: +263 971 740 (Bul)

Tel: +263 479 2564 (Har)

www.cadac.co.zw

CADAC GERMANY

Ratio 26, 6921 RW Duiven

The Netherlands

Tel: +31 26 319 7740

Email: info@cadaceurope.com

www.cadacinternational.com

CADAC Czech Rep.

RÖSLER Praha spel. s r.o.

K Horkam 19/21

102 00 Praha 10 Ceska republika

Tel: +420 267 188 011

Email: info@rosler.cz

www.rosler.cz

CADAC FINLAND

OY KAMA FRITID AB

Koiyuhaantie 2-4 B

01510 VANTAA

00358207920310

info@kamafritid.fi

CADAC POLAND

Kamai

Wola Batorska 461

32-007 Wola Batorska Poland

Tel: +48 12 635 1373

Email: handlowy@kamai.pl

www.kamai.pl

CADAC ZAMBIA

Exclusive Brands Africa Limited

7225A Kachidza Road

Light Industrial Area

Lusaka, Zambia

Tel: +260 211 842015

Tel: +260977 345034

Email: info@ebagrp.com

CADAC FRANCE

LeViallon,42520Veranne

France

Tel: +33 4 74 78 13 65

Email: info@cadaceurope.com

www.cadacinternational.com

CADAC NEW ZEALAND

Riverlea Group (Pty) Ltd

2A Maui Street, Pukete,

Hamilton 3200, New Zealand

Tel: +64 7 847 0204

Email: sales@riverleagroup.co.nz

www.riverleagroup.co.nz

CADAC U.A.E.

Supreme Impex General Trading

LLC Office No. 1801-7 Latifa

Tower Sheikh Zayed Road

Dubai, UAE

CADAC ITALY

Brunner SRL/GMBH

via Buozzi, 8

39100 Bolzano (Italy)

Tel: +39 0471 542900

Email: info@brunner.it

www.brunnerinternational.com

CADAC SOUTH EAST EUROPE

Bulevar oslobodjenja 285

Tel: +381 11 339 2700

Email: sinisaj@cadac.rs

www.cadac.rs

CADAC 2cook Classic - CADAC SOUTH EAST EUROPE - 1

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : CADAC

Model : 2cook Classic

Category : Cooker