LANAFORM Trainy - Humidifier

Trainy - Humidifier LANAFORM - Free user manual and instructions

Find the device manual for free Trainy LANAFORM in PDF.

📄 92 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice LANAFORM Trainy - page 4
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Ultrasonic humidifier
Brand Lanaform
Model Trainy
Dimensions (L x D x H) 22 x 15 x 32 cm
Weight 1.2 kg
Power supply 220-240 V ~ 50/60 Hz
Power 25 W
Tank capacity 2.5 litres
Coverage area Up to 25 m²
Noise level < 35 dB(A)
Steam output 200 ml/h (max)
Main functions Humidification, automatic shut-off, LED night light, removable tank
Maintenance and cleaning Weekly cleaning of the tank and ultrasonic membrane with white vinegar
Safety Automatic shut-off when tank is empty
Spare parts and repairability Diffuser, membrane, tank available
General information Silent air humidifier, ideal for bedroom or office

Frequently Asked Questions - Trainy LANAFORM

How to clean the Lanaform Trainy humidifier?
Unplug the device, empty the tank and clean it with a soft cloth and white vinegar. Rinse thoroughly with clean water. Clean the ultrasonic membrane with a soft brush.
Why is my humidifier not producing mist anymore?
Check the water level in the tank. If the tank is empty, the automatic shut-off activates. Make sure the membrane is clean. A limescale deposit can block mist production.
What is the water tank capacity?
The tank has a capacity of 2.5 litres, providing about 10 to 12 hours of autonomy depending on the flow rate.
Can I use essential oils in the humidifier?
No, this humidifier is not designed for essential oils. Using oils can damage the membrane and void the warranty.
How to adjust the humidity level?
The Lanaform Trainy does not have a built-in hygrostat. The mist output is manually adjustable via a rotary knob. To maintain optimal humidity, use a separate hygrometer.
The humidifier is making noise, is this normal?
A slight gurgling is normal. If the noise is loud, check that the tank is properly engaged. A clicking noise may indicate limescale buildup on the membrane.
How do I know if the humidifier is running?
An LED night light turns on when the device is operating. You can also see mist coming out of the nozzle.
Do I need to use demineralized water?
It is recommended to use distilled or demineralized water to reduce limescale and extend the membrane's lifespan.
Where can I find spare parts for the Trainy?
Spare parts (tank, membrane, diffuser) are available on the official Lanaform website or from authorized dealers. Check the manual for references.
What is the warranty on the humidifier?
The standard warranty is 2 years against manufacturing defects. Keep your receipt and register your product online to activate the warranty.

User questions about Trainy LANAFORM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Humidifier in PDF format for free! Find your manual Trainy - LANAFORM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Trainy by LANAFORM.

USER MANUAL Trainy LANAFORM

LANAFORM Trainy - 1

natural_image Hand holding a small mechanical device with wheels and a camera, showing motion arrows (no text or symbols visible)

LANAFORM Trainy - 2

natural_image Close-up of hands holding a white plastic device with a circular button and a small circular component (no visible text or symbols)

LANAFORM Trainy - 3

natural_image Hand inserting a pipette into a device component (no visible text or symbols)

LANAFORM Trainy - 4

natural_image Hand pouring liquid from a bottle into a water dispenser (no text or symbols visible)

LANAFORM Trainy - 5

natural_image Mechanical device with two wheels and a handle, showing mechanical components and directional arrows (no text or symbols)

LANAFORM Trainy - 6

natural_image White toy train with glass roof and visible wheels, no text or symbols present

LANAFORM Trainy - 7

natural_image Close-up of a mechanical component with a circular dial and radial slots (no visible text or symbols)

INSTRUCTION MANUAL

Thank you for your interest in Lanaform®'s TRAINY humidifier.

The most comfortable relative humidity for human beings is between 45% and 55%. Air which is too dry and which is poor quality may be the source of many problems for our children: respiratory problems, dehydration, etc.

The TRAINY humidifier is the perfect solution to this problem. Very easy to use, the TRAINY is equipped with a 1.8 litre tank, which is easy to fill and secure in place. It has an autonomy of more than 9 hours, guaranteeing a peaceful night for your child. The TRAINY is equipped with an integrated safety system which guarantees safe usage. Operational in a flash, the humidifier has a blue light which soothes your child. Its operation is immediate and silent, with an adjustable vapour output.

What's more, it comes with a dish for diffusing essential oils.

PLEASE READ ALL THE INSTRUCTIONS BEFORE USING YOUR HUMIDIFIER, IN PARTICULAR THESE FEW FUNDAMENTAL SAFETY RULES:

  • Only use this appliance for the purposes described in this manual.
  • Make sure that the voltage indicated on the appliance corresponds to that of your power supply.
  • This appliance is not intended for use by persons (including children) whose physical, sensory or mental capabilities are impaired, or by persons lacking experience or knowledge, unless they have had the benefit of prior supervision and instruction in using the device from a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Please do not use accessories which are not recommended by LANAFORM or which are not supplied with this appliance.
  • If the power lead is damaged, it must be replaced by a special or similar lead available from the supplier or after-sales department.
  • Do not use this appliance if the plug is damaged, if it is not working correctly, if it has been dropped or damaged or if it has fallen into water. If this is the case, have the appliance inspected and repaired by the supplier or its after-sales department.
    • Always disconnect the appliance from the mains after use and before cleaning it.
  • Should the appliance fall into water, unplug it immediately before retrieving it.
  • An electrical appliance should never be left plugged in and unsupervised. Disconnect it from the mains electricity supply if you are not using it.
  • Keep the power lead away from hot surfaces.
  • Never use this appliance in a room where aerosol products (sprays) are used or in a room where oxygen is administered.
    • This appliance is intended exclusively for family use.
  • Never obstruct the appliance's air vents and never place the device on an unstable surface such as a carpet or mattress. This could prevent air circulation. Make sure that the air vents are not clogged with hair, lint, dust, etc. Do not insert any objects into the air vents.
    • Always position the humidifier on a hard, flat, horizontal surface, at least FIFTEEN centimetres from walls and keep away from heat sources such as cookers, radiators, etc. The humidifier cannot work correctly on a non-horizontal surface.
  • Do not use this appliance near water, electrical appliances or wooden furniture.
  • Never attempt to plug or unplug this appliance if you are in contact with water or in a damp environment. This could result in the risk of electric shock.

  • Never immerse or plunge the appliance into water or any other liquid in order to clean it.

  • The ultrasound humidifier must be cleaned regularly. To do this, refer to the cleaning instructions in this manual and follow them closely.
  • Never remove the base unit.
  • If there is water leaking from the appliance or if there is an unusual smell during use, switch the appliance off immediately and return it to the supplier or after-sales department.
  • Do not add any substance other than distilled or demineralised water to the tank at a temperature below 40^ .
  • Never switch on the humidifier if there is no water in the tank.
  • Do not shake the appliance. This could cause water to overflow into the base unit and affect its operation.
  • Never touch the water and the immersed components when the unit is in operation.
  • To prevent any damage to the components, avoid splashing the inside of the base unit.
  • Do not use essential oils which are not recommended.
  • Do not use artificial perfumes or essential oils, these may damage the device.
  • Never scratch the transducer.
  • In temperatures of below freezing (below 0^ ), remove the water from the tank and the base to prevent the risk of freezing.
  • Do not use the humidifier if the air in the room is already humid enough (at least 50% relative humidity). Excess humidity manifests itself by condensation on cold surfaces or cold walls in the room. To determine the correct humidity level in the room, use a hygrometer - these are available in most material stores and in hypermarkets.
  • The appliance should be used at a temperature of between 5^ and 40^ and a relative humidity of less than 50% RH.

COMPONENTS (Fig. 1)

  1. Base unit

  2. Main switch (ON/OFF and Vapour Setting)

  3. Warning light

  4. Tank

  5. Water level sensor

  6. Transducer

  7. Fan

  8. Tank plug

  9. Spray

  10. Essential oil drawer

  11. Filter

INSTRUCTIONS FOR USE

Characteristics:

• Capacity 1.8 litres
• Continuous operation for more than 9 hours.
- Easy-fill water tank.
- Dish for diffusing essential oils.

  • Integrated safety mechanism which automatically stops the diffuser from working when the water tank is empty.
  • High-quality transducer guarantees correct and long-lasting operation.

Functions:

• Increases and adjusts the relative humidity of the room.
- Eliminates electrostatic charges.
- Improves the quality of the air in the room.

How to use it:

  • Place the appliance in the room half an hour before turning it on so that it becomes adjusted to the room temperature.
  • Remove the water tank from the appliance (Fig. 2), unscrew the cap by turning it anticlockwise (Fig. 3).
  • The humidifier is equipped with a water filter. This filter contributes in particular to treating the calcium content of the water. To attach this, attach the water filter to the inside of the tank cap.
  • Fill the tank with clean water at a maximum temperature of 40^ (Fig. 4). Check that the silicon washer is correctly positioned, then close the cover by turning the latter in a clockwise direction.
  • Make sure that it is clean and watertight then carefully position the tank in the base unit. (Fig. 5).
  • You can then fill the drawer dish with a few drops of essential oil. Warning: Please refer to the paragraph relating to the use of essential oils in this manual.
  • With dry hands, plug in and switch on the appliance. The blue warning light lights up. The appliance starts working. (Fig. 6).
  • You can then adjust it to the desired vapour intensity by turning the vapour intensity control button (Fig. 7).
  • Once the tank is empty, the safety mechanism inside the appliance will automatically stop the electricity supply if the circuit is overheating.
  • Strict monitoring is required at all times to prevent any risk.

IMPORTANT: Using essential oils:

To diffuse essential oil in the appliance, only use the drawer-dish designed for this purpose, located at the back of the appliance. Pour a few drops of essential oil onto the "cotton" and then close the drawer. (Fig. 8).

Never pour the essential oil directly into the water tank as this may irreparably damage the appliance.

Before choosing the essential oil to diffuse, you should seek advice from the sales adviser at the shop.

WARNING:

DESPITE THE SAFETY MECHANISM WHICH STOPS THE TRANSDUCER WORKING, AVOID AS MUCH AS POSSIBLE LEAVING THE DEVICE PLUGGED IN WHEN NOT IN USE.

MAINTENANCE AND STORAGE:

If the water is hard - in other words, if it contains too much calcium and magnesium - it can leave a «white powder» in the appliance and cause heavy scaling on the surface of the tank, on the transducer (ceramic tablet which generates ultrasounds) and on the internal walls of the water tank. Build-up on the surface of the transducer prevents the appliance from working correctly.

We recommend:

1) Using boiled water which has been allowed to cool or distilled water each time,
2) cleaning the tank every 3 days and the transducer every week,
3) changing the water in the tank regularly so that it is fresh, not leaving it in the appliance for more than 2 days,
4) Cleaning the appliance and making sure that all its components are completely dry when not in use.

To clean the transducer:

1) Pour 2 to 5 drops of vinegar on its surface and leave for 2 to 5 minutes.
2) Brush the scale off the surface with a soft brush. Do not use a hard tool to scratch at the surface.
3) Rinse the transducer with clear water.
4) Do not use soap or other alkaline substances to clean the transducer.

To clean the tank unit:

1) Clean the water tank with a soft cloth and use vinegar if there is scale or chalky deposits on its interior.
2) If there is scale covering the cut-out switch, pour a few drops of vinegar on it and clean with a brush.
3) Rinse the tank with clear water.

Storage:

1) Carefully clean and dry the ultrasound humidifier, following the maintenance instructions.
2) Let it dry completely before placing in storage. Do not store it with water remaining in the base.
3) Store the appliance in a cool and dry place away from children.

To clean the filter

1) The performance of the demineralisation process and life of your filter depends on the mineral content of the water used with the humidifier. As a reminder, distilled or demineralised water is recommended.

2) Please consider rinsing the filter with clear water every 2 days. In order to achieve this, remove the latter from the tank plug.

TROUBLESHOOTING

If the appliance malfunctions in everyday use, please refer to the table below:

BREAKDOWN POSSIBLE CAUSES REMEDIES
No blowing, no vapourNo power Plug in the appliance
The vapour intensity control is at minimumAdjust the vapour intensity
Water level in the groove is too high. Remove the water from the trough
The water tank is leaking. Tighten the lid correctly
Blowing but no vapourNo water in the tank Fill the tank
The temperature of the device is too low.Place the device in the room at room temperature for half an hour prior to use.

EN

Strange-smelling vapour The water hasbeen in the tank too long.Clean the tank and fill with fresh water.
Essential oil. Replace the cotton used for the essential oil.
Low intensity The vapour intensity control is at minimumAdjust the control button
Sediment on the transducer. Clean the transducer.
The water is too cold. Use water at room temperature.
The water is unclean. Clean the tank and fill with fresh water.
The vapour is not risingThe vapour intensity control is at minimumAdjust the vapour intensity
The tank and the base are not connected properlyCheck that they are connected properly
The fan is not working correctly Return appliance to supplier or after-sales department.
NoiseResonance due to the water level in the tank being too lowAdd water to the tank.
Resonance due to an unstable surface place the unit on a stable surface

TECHNICAL SPECIFICATION

• Maximum evaporation rate: 200 ml/h
• Capacity of the water tank: 1.8 L
- Noise: ≤ 35dB

ADVICE REGARDING THE DISPOSAL OF WASTE

LANAFORM Trainy - ADVICE REGARDING THE DISPOSAL OF WASTE - 1

- All the packaging is composed of materials that pose no hazard for the environment and which can be disposed of at your local sorting centre to be used as secondary raw materials. The cardboard may be disposed of in a paper recycling bin. The packaging film must be taken to your local sorting and recycling centre.

- When you have finished using the device, please dispose of it in an environmentally friendly way and in accordance with the law.

LIMITED WARRANTY

LANAFORM® guarantees this product against any material or manufacturing defect for a period of two years from the date of purchase, except in the circumstances described below.

The LANAFORM® guarantee does not cover damage caused as a result of normal wear to this product. In addition, the guarantee covering this LANAFORM® product does not cover damage caused by abusive or inappropriate or incorrect use, accidents, the use of unauthorized accessories, changes made to the product or any other circumstance, of whatever sort, that is outside LANAFORM®'s control.

LANAFORM® may not be held liable for any type of circumstantial, indirect or specific damage.

All implicit guarantees relating to the suitability of the product are limited to a period of two years from the initial date of purchase as long as a copy of the proof of purchase can be supplied.

On receipt, LANAFORM ^® will repair or replace your appliance at its discretion and will return it to you. The guarantee is only valid through LANAFORM ^® 's Service Centre ^® . Any attempt to maintain this product by a person other than LANAFORM ^® 's Service Centre will render this guarantee void.

The photographs and other images of the product in this manual and on the packaging are as accurate as possible, but do not claim to be a perfect reproduction of the product.

EN

MANUEL D'INSTRUCTION

BESCHRÄNKTE GARANTIE

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : LANAFORM

Model : Trainy

Category : Humidifier