| Product Type | Air Humidifier |
| Brand | Vitek |
| Model | VT-1767 BK |
| Power Supply | 220-240 V, ~50 Hz |
| Power Consumption | 140 W |
| Water Tank Capacity | 5 L |
| Water Flow | 300 ml/h |
| Humidified Area | Up to 50 m² |
| Operating Life | 5 years |
| Functions | Ionization, Water Heating, Automatic Humidity Control (45-90%), Timer (1-12 hours), Remote Control |
| Safety Features | Auto shut-off when tank empty, low water indicator |
| Filter Type | Cartridge filter (clean every 500 L or more often) |
| Cleaning | Weekly cleaning of water tank and sprayer with neutral detergent; filter cleaning with vinegar |
| Delivery Set | Humidifier, Water Tank, Tank Lid, Instruction Manual, Remote Control, Cleaning Brush |
| Warranty | Details from dealer; conforms to EMC and Low Voltage Directives |
Frequently Asked Questions - VT-1767 BK Vitek
User questions about VT-1767 BK Vitek
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Humidifier in PDF format for free! Find your manual VT-1767 BK - Vitek and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. VT-1767 BK by Vitek.
USER MANUAL VT-1767 BK Vitek
ENGLISH
AIR HUMIDIFIER
Description
- "Power" button for switching on/off the unit
- "Ozone" button for switching on/off the ionization mode
- "Max-Min" button for setting the mist release intensity
- "Heating" button for switching on/off the water heating mode
- "Humidity" button for setting the relative humidity in the room
- "Timer" setting button
- Display
- Mist release opening
- Handle for convenient filling/carrying the water tank
- Water tank
- Water inlet
- Cartridge filter
- Water tank lid
- Sprayer
- Water tank illumination
- Body
- Remote control
- Sprayer cleaning brush
Display (7) icons
- Room temperature indication
- Operation time left indication
- Ionization mode icon
- Empty water tank icon
- Water heating-up mode icon
- Humidifier On/Off icon
- Room humidity/preset humidity indication
- Humidity level intensity indication
Remote control (17)
- Button for setting the relative humidity in the room
- Button for setting the mist release intensity
- On/Off button of the unit
- On/Off button of ionization mode
- On/Off button of water heating-up mode
- Timer setting button
SAFETY MEASURES
Before using the air humidifier, please read this instruction manual carefully and keep it for the whole operation period.
- Before switching on make sure that the voltage of the electric network corresponds to the operating voltage of the unit.
- Place the unit on the flat, moisture-resistant surface. Distance to the walls should be at least 15 cm.
- Do not direct the nozzle at the furniture, electrical appliances, books and objects, which can be damaged by moisture.
- Do not place the humidifier in places exposed to direct sunlight, high temperatures, near computers or other sensitive electronic appliances.
- Do not leave the unit unattended in a closed room, this can lead to appearance of condensation on furniture and walls. That's why we recommend keeping the door of the room, where the humidifier is used, half-opened.
- Do not use the unit outdoors.
- Use only removable parts supplied with the unit.
- For children safety do not leave polyethylene bags, used as a packaging, unattended.
Attention! Do not allow children to play with polyethylene bags and film. Danger of suffocation! - Keep the unit out of reach of children.
- Do not allow children to use the unit as a toy.
- This unit is not intended for usage by children or disabled persons unless they are given all the necessary instructions by a person who is responsible for their safety on safety measures and information about danger that can be caused by improper usage of the unit.
- Do not switch on the humidifier without water, disconnect the unit from the power supply when the water tank becomes empty.
- Do not use soda water or any perfume additives.
- Unplug the unit before removing the water tank.
- Do not cover the mist release openings and the humidity level indication on the power cord and avoid getting of foreign objects into them.
- Do not immerse the unit, the power cord with humidity level indication or the power plug into water or other liquids.
ENGLISH
- Do not move or tilt the unit during its operation.
- Always unplug the unit and pour out water from the water tank before cleaning or if you do not use the unit.
- Unplug the humidifier before moving it to another place.
- Do not touch the power plug with wet hands.
- Before using the unit, closely examine the power cord and make sure that it is not damaged. Do not use the unit if the power cord is damaged.
- Do not dismantle the humidifier by yourself, if any malfunction is detected, apply to the nearest authorized service center.
- Regularly clean the unit; do not allow scratches to appear on the sprayer.
Before the first use
Unpack the air humidifier and remove package materials. Examine the humidifier for damages. Do not switch on the humidifier in case of damages.
Note:
- If the humidifier was exposed to negative temperatures, before switching it on for the first time, keep it at room temperature for 30 minutes.
- Use the humidifier at the room temperature from +5^ to +40^ , and relative humidity less than 80% .
- Water temperature should not exceed +40°C.
Before connecting the humidifier to the mains make sure that the voltage of the electric network corresponds to the unit operating voltage.
- Take the handle (9) and remove the water tank (10) from the unit body (16).
- Turn over the tank (10), open the lid (13) rotating it counterclockwise. Fill the tank (10) with necessary amount of water, close the lid (13) rotating it clockwise.
- Place the filled water tank (10) on the unit body (16). Wait for some time, which is necessary to fill the operating chamber with water.
- Connect the humidifier to the mains, an icon (24) will flash on the display (7), the room
temperature (19) and humidity (25) will be shown.
- Switch on the humidifier pressing the "Power" on/off button (1), the icon (24) will go out, the display will switch to full brightness and the mist release intensity icon (26) will appear.
Note:
- Every pressing of the control buttons is accompanied with a sound signal.
- If no button has been pressed during 30 seconds on the control panel or on the remote control, the display brightness will decrease automatically.
- To switch on the ionization mode, press "Ozone" button (2), an icon (21) will flash on the display (7). To switch off the ionization mode, press "Ozone" button (2) again, the icon (21) will go out.
- You can set necessary intensity by pressing the "Max-Min" button for setting the mist release intensity (3), the intensity will be shown on the display (7) as a changing icon (26).
- To switch on the water heating mode, press "Heating" button (4), an icon (23) will flash on the display (7). In this mode evaporable water is preliminarily heated, which helps to disinfect the water and facilitates its evaporation.
Note:
- Switching on this function may slightly change the room temperature (19) and humidity (25) indication on the display (7).
- To switch on the automatic humidity maintenance mode, press the "Humidity button (5), the icon Humid will be flashing on the display, press repeatedly the button (5) to set the required humidity in the room (from 45 to 90%, setting step is 5%). In this mode the icon "Humid" is flashing on the display (7), and the following settings are shown: temperature (19), humidity in the room (25) and mist release intensity (26). To view the preset humidity value press the "Humidity button (4) once, flashing value of the preset humidity will appear on the display (7), in 5 seconds the information on the display will return to the previous mode. To switch off the automatic humidity maintenance mode, press the "Humidity button (5) the required number of
ENGLISH
times, when the humidity value passes 90%, the current room air humidity will be shown on the display.
Note:
- If the humidifier operates in the automatic humidity maintenance mode, the mist release intensity control will be performed automatically.
-
You can set the operation time of the humidifier with "Timer" button (6). By pressing the button (6) set the required operation time from 1 to 12 hours, which is shown as a digital indication (20) on the display (7).
-
After finishing the operation switch off the unit by pressing the "Power" button (5), an icon (21) will appear on the display (7), and both room temperature (27) and humidity (28) will be shown.
-
When the water tank (10) becomes empty, the humidifier will switch off automatically, the indication (22) will light up on the display (7) and you will hear sound signals.
Note:
- Illumination (15) will help you to evaluate the amount of water in the tank.
REMOTE CONTROL (17)
Use the remote control for convenient control of the humidifier.
If there is an isolation insert in the battery compartment, remove it, if the battery is supplied separately, remove the holder of the battery, by preliminary pressing the clamp, insert the battery in the holder, strictly following the polarity, insert the battery holder into the remote control.
Cleaning and care
Warning! Always switch off and unplug the unit before cleaning.
- Hard water causes the appearance of mineral scale on the sprayer, on the inner parts of the body and in the water tank; it leads to improper operation of the humidifier and appearance of white deposits on interior objects.
- To avoid this it is necessary to clean the sprayer weekly and change water as often as possible, as well as to perform cleaning of the cartridge filter.
- If you are not going to use the humidifier for a long time, pour out water from the tank and the operating chamber of the sprayer, wash
the water tank, wash and clean the operating chamber of the sprayer and the sprayer itself, dry the unit carefully and take it away for storage.
Weekly care
- Once a week wash the water tank (10) and the operating chamber under the tank carefully with a neutral detergent solution.
- Then carefully rinse them with water.
- Add 5-10 drops of the detergent on the sprayer (14); wait about 2-5 minutes. Remove the deposit from the sprayer surface (14) with a brush (18).
Note:
- As a cleaning agent for the sprayer you can use scale removal substances for kettles.
Do not immerse the humidifier body into water or other liquids.
Filter cleaning
- Clean the filter (12) after passing of about 500 l water through it, and more often, if using hard water or if white deposits appear on furniture.
- Take the handle (9) and remove the water tank (10) from the unit body (16).
- Turn over the tank (10), open the lid (13) rotating it counterclockwise, remove the cartridge filter (12), rotating it counterclockwise.
- Put the cartridge filter (12) into a container with vinegar for 10 minutes, then take the cartridge filter (12) out and rinse it with running water.
- Install the cartridge filter (12) back in the lid (13), rotating it clockwise.
Storage
- If you are not going to use the unit for a long time and want to take it away for storage, make sure that all its parts are dry, including the operating chamber of the "sprayer".
- Do not store the unit with water in the water tank or in the operating chamber of the sprayer.
- Clean and dry the cartridge filter before taking it away for storage. Keep the cartridge filter in a cool darkened place.
Keep the humidifier away from children in a dry cool place.
Troubleshooting
ENGLISH
| Failure Possible causes | Troubleshooting | |
| The operation indicator doesn’t light up, no mist release | No voltage, no power supply | Connect the unit to the mains |
| Plug another, certainly operating appliance to the socket to make sure that the socket works properly | ||
| No mist release Water tank | is empty Fill the water tank with water | |
| Mist smells unpleasantly F | First use of the unit Remove | the water tank lid, pour out the water and leave the tank open for 12 hours in a cool darkened place |
| Dirty or stale water Unplug the unit, remove the water tank, pour out the water, wash the tank and fill it with clean or distilled water | ||
| Low mist release intensity Sprayer is dirty Unplug the unit and clean the sprayer | ||
| Foreign noise is heard during the operation of the humidifier | The unit is placed on an uneven or unstable surface | Unplug the unit and level the unit body or set it in another place |
Note:
Non-observance of rules for cleaning the sprayer from mineral deposits may affect the overall performance of the unit. In this case clean the unit. If used tap water is too hard, use water filters to clean water or mix it with distilled water in proportion 1:1.
Delivery set
Air humidifier -1 pc.
Removable water tank - 1 pc.
Removable water tank lid - 1 pc.
Instruction manual - 1 pc.
Technical specifications
Power supply: 220-240 V, \~ 50 Hz
Power consumption: 140 W
Water tank capacity: 5 L
Water flow: 300 ml/h
Humidified area: up to 50 m ^4
The manufacturer preserves the right to change the design and the specifications of the unit without a preliminary notification.
Unit operating life is 5 years
Guarantee
Details regarding guarantee conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.

This product conforms to the EMC-Requirements as laid down by the Council Directive 89/336/EEC and to the Low Voltage Regulation (73/23 EEC)
DEUTSCH
LUFTBEFEUCHTER
Beschreibung
A production date of the item is indicated in the serial number on the technical data plate. A serial number is an eleven-unit number, with the first four figures indicating the production date. For example, serial number 0606xxxxxxx means that the item was manufactured in June (the sixth month) 2006.