Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeAir Humidifier
BrandVitek
ModelVT-1767 BK
Power Supply220-240 V, ~50 Hz
Power Consumption140 W
Water Tank Capacity5 L
Water Flow300 ml/h
Humidified AreaUp to 50 m²
Operating Life5 years
FunctionsIonization, Water Heating, Automatic Humidity Control (45-90%), Timer (1-12 hours), Remote Control
Safety FeaturesAuto shut-off when tank empty, low water indicator
Filter TypeCartridge filter (clean every 500 L or more often)
CleaningWeekly cleaning of water tank and sprayer with neutral detergent; filter cleaning with vinegar
Delivery SetHumidifier, Water Tank, Tank Lid, Instruction Manual, Remote Control, Cleaning Brush
WarrantyDetails from dealer; conforms to EMC and Low Voltage Directives

Frequently Asked Questions - VT-1767 BK Vitek

How do I set the automatic humidity mode?
Press the Humidity button repeatedly until the desired humidity (45-90% in 5% steps) is shown on the display. The humidifier will maintain that level automatically.
What does the ionization mode do?
The ionization mode releases negative ions to purify the air and reduce airborne particles. Press the Ozone button to toggle it on/off.
How to use the timer function?
Press the Timer button repeatedly to set the operation time from 1 to 12 hours. The display shows the remaining time.
Why is there no mist coming out?
Check if the water tank is empty. If empty, fill it with water. Also ensure the unit is connected to power and turned on.
How to clean the sprayer?
Apply 5-10 drops of neutral detergent or a descaling solution to the sprayer, wait 2-5 minutes, then scrub with the included brush. Rinse thoroughly.
How to clean the cartridge filter?
Remove the filter from the lid, soak it in vinegar for 10 minutes, then rinse under running water. Reinstall after drying.
Can I use essential oils or perfume additives?
No. The manual explicitly states do not use soda water or any perfume additives as they may damage the unit or create white dust.
What type of water should I use?
Use clean tap water. If water is very hard, mix with distilled water in a 1:1 ratio or use a water filter to prevent mineral buildup.
How to store the humidifier when not in use?
Empty the water tank and operating chamber, clean and dry all parts, including the filter. Store in a cool, dry place away from children.
What does the empty water tank icon mean?
When the water tank is empty, the empty tank icon lights up and the unit shuts off automatically. Refill the tank to resume operation.

User questions about VT-1767 BK Vitek

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Humidifier in PDF format for free! Find your manual VT-1767 BK - Vitek and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. VT-1767 BK by Vitek.

USER MANUAL VT-1767 BK Vitek

ENGLISH

AIR HUMIDIFIER

Description

  1. "Power" button for switching on/off the unit
  2. "Ozone" button for switching on/off the ionization mode
  3. "Max-Min" button for setting the mist release intensity
  4. "Heating" button for switching on/off the water heating mode
  5. "Humidity" button for setting the relative humidity in the room
  6. "Timer" setting button
  7. Display
  8. Mist release opening
  9. Handle for convenient filling/carrying the water tank
  10. Water tank
  11. Water inlet
  12. Cartridge filter
  13. Water tank lid
  14. Sprayer
  15. Water tank illumination
  16. Body
  17. Remote control
  18. Sprayer cleaning brush

Display (7) icons

  1. Room temperature indication
  2. Operation time left indication
  3. Ionization mode icon
  4. Empty water tank icon
  5. Water heating-up mode icon
  6. Humidifier On/Off icon
  7. Room humidity/preset humidity indication
  8. Humidity level intensity indication

Remote control (17)

  1. Button for setting the relative humidity in the room
  2. Button for setting the mist release intensity
  3. On/Off button of the unit
  4. On/Off button of ionization mode
  5. On/Off button of water heating-up mode
  6. Timer setting button

SAFETY MEASURES

Before using the air humidifier, please read this instruction manual carefully and keep it for the whole operation period.

  • Before switching on make sure that the voltage of the electric network corresponds to the operating voltage of the unit.
  • Place the unit on the flat, moisture-resistant surface. Distance to the walls should be at least 15 cm.
  • Do not direct the nozzle at the furniture, electrical appliances, books and objects, which can be damaged by moisture.
  • Do not place the humidifier in places exposed to direct sunlight, high temperatures, near computers or other sensitive electronic appliances.
  • Do not leave the unit unattended in a closed room, this can lead to appearance of condensation on furniture and walls. That's why we recommend keeping the door of the room, where the humidifier is used, half-opened.
  • Do not use the unit outdoors.
  • Use only removable parts supplied with the unit.
  • For children safety do not leave polyethylene bags, used as a packaging, unattended.
    Attention! Do not allow children to play with polyethylene bags and film. Danger of suffocation!
  • Keep the unit out of reach of children.
  • Do not allow children to use the unit as a toy.
  • This unit is not intended for usage by children or disabled persons unless they are given all the necessary instructions by a person who is responsible for their safety on safety measures and information about danger that can be caused by improper usage of the unit.
  • Do not switch on the humidifier without water, disconnect the unit from the power supply when the water tank becomes empty.
  • Do not use soda water or any perfume additives.
  • Unplug the unit before removing the water tank.
  • Do not cover the mist release openings and the humidity level indication on the power cord and avoid getting of foreign objects into them.
  • Do not immerse the unit, the power cord with humidity level indication or the power plug into water or other liquids.

ENGLISH

  • Do not move or tilt the unit during its operation.
  • Always unplug the unit and pour out water from the water tank before cleaning or if you do not use the unit.
  • Unplug the humidifier before moving it to another place.
  • Do not touch the power plug with wet hands.
  • Before using the unit, closely examine the power cord and make sure that it is not damaged. Do not use the unit if the power cord is damaged.
  • Do not dismantle the humidifier by yourself, if any malfunction is detected, apply to the nearest authorized service center.
  • Regularly clean the unit; do not allow scratches to appear on the sprayer.

Before the first use

Unpack the air humidifier and remove package materials. Examine the humidifier for damages. Do not switch on the humidifier in case of damages.

Note:

  • If the humidifier was exposed to negative temperatures, before switching it on for the first time, keep it at room temperature for 30 minutes.
  • Use the humidifier at the room temperature from +5^ to +40^ , and relative humidity less than 80% .
  • Water temperature should not exceed +40°C.

Before connecting the humidifier to the mains make sure that the voltage of the electric network corresponds to the unit operating voltage.

  1. Take the handle (9) and remove the water tank (10) from the unit body (16).
  2. Turn over the tank (10), open the lid (13) rotating it counterclockwise. Fill the tank (10) with necessary amount of water, close the lid (13) rotating it clockwise.
  3. Place the filled water tank (10) on the unit body (16). Wait for some time, which is necessary to fill the operating chamber with water.
  4. Connect the humidifier to the mains, an icon (24) will flash on the display (7), the room

temperature (19) and humidity (25) will be shown.

  1. Switch on the humidifier pressing the "Power" on/off button (1), the icon (24) will go out, the display will switch to full brightness and the mist release intensity icon (26) will appear.

Note:

  • Every pressing of the control buttons is accompanied with a sound signal.
  • If no button has been pressed during 30 seconds on the control panel or on the remote control, the display brightness will decrease automatically.
  • To switch on the ionization mode, press "Ozone" button (2), an icon (21) will flash on the display (7). To switch off the ionization mode, press "Ozone" button (2) again, the icon (21) will go out.
  • You can set necessary intensity by pressing the "Max-Min" button for setting the mist release intensity (3), the intensity will be shown on the display (7) as a changing icon (26).
  • To switch on the water heating mode, press "Heating" button (4), an icon (23) will flash on the display (7). In this mode evaporable water is preliminarily heated, which helps to disinfect the water and facilitates its evaporation.

Note:

- Switching on this function may slightly change the room temperature (19) and humidity (25) indication on the display (7).

  1. To switch on the automatic humidity maintenance mode, press the "Humidity button (5), the icon Humid will be flashing on the display, press repeatedly the button (5) to set the required humidity in the room (from 45 to 90%, setting step is 5%). In this mode the icon "Humid" is flashing on the display (7), and the following settings are shown: temperature (19), humidity in the room (25) and mist release intensity (26). To view the preset humidity value press the "Humidity button (4) once, flashing value of the preset humidity will appear on the display (7), in 5 seconds the information on the display will return to the previous mode. To switch off the automatic humidity maintenance mode, press the "Humidity button (5) the required number of

ENGLISH

times, when the humidity value passes 90%, the current room air humidity will be shown on the display.

Note:

- If the humidifier operates in the automatic humidity maintenance mode, the mist release intensity control will be performed automatically.

  1. You can set the operation time of the humidifier with "Timer" button (6). By pressing the button (6) set the required operation time from 1 to 12 hours, which is shown as a digital indication (20) on the display (7).

  2. After finishing the operation switch off the unit by pressing the "Power" button (5), an icon (21) will appear on the display (7), and both room temperature (27) and humidity (28) will be shown.

  3. When the water tank (10) becomes empty, the humidifier will switch off automatically, the indication (22) will light up on the display (7) and you will hear sound signals.

Note:

- Illumination (15) will help you to evaluate the amount of water in the tank.

REMOTE CONTROL (17)

Use the remote control for convenient control of the humidifier.

If there is an isolation insert in the battery compartment, remove it, if the battery is supplied separately, remove the holder of the battery, by preliminary pressing the clamp, insert the battery in the holder, strictly following the polarity, insert the battery holder into the remote control.

Cleaning and care

Warning! Always switch off and unplug the unit before cleaning.

- Hard water causes the appearance of mineral scale on the sprayer, on the inner parts of the body and in the water tank; it leads to improper operation of the humidifier and appearance of white deposits on interior objects.

- To avoid this it is necessary to clean the sprayer weekly and change water as often as possible, as well as to perform cleaning of the cartridge filter.

- If you are not going to use the humidifier for a long time, pour out water from the tank and the operating chamber of the sprayer, wash

the water tank, wash and clean the operating chamber of the sprayer and the sprayer itself, dry the unit carefully and take it away for storage.

Weekly care

  1. Once a week wash the water tank (10) and the operating chamber under the tank carefully with a neutral detergent solution.
  2. Then carefully rinse them with water.
  3. Add 5-10 drops of the detergent on the sprayer (14); wait about 2-5 minutes. Remove the deposit from the sprayer surface (14) with a brush (18).

Note:

- As a cleaning agent for the sprayer you can use scale removal substances for kettles.

Do not immerse the humidifier body into water or other liquids.

Filter cleaning

  1. Clean the filter (12) after passing of about 500 l water through it, and more often, if using hard water or if white deposits appear on furniture.
  2. Take the handle (9) and remove the water tank (10) from the unit body (16).
  3. Turn over the tank (10), open the lid (13) rotating it counterclockwise, remove the cartridge filter (12), rotating it counterclockwise.
  4. Put the cartridge filter (12) into a container with vinegar for 10 minutes, then take the cartridge filter (12) out and rinse it with running water.
  5. Install the cartridge filter (12) back in the lid (13), rotating it clockwise.

Storage

  • If you are not going to use the unit for a long time and want to take it away for storage, make sure that all its parts are dry, including the operating chamber of the "sprayer".
  • Do not store the unit with water in the water tank or in the operating chamber of the sprayer.
  • Clean and dry the cartridge filter before taking it away for storage. Keep the cartridge filter in a cool darkened place.
    Keep the humidifier away from children in a dry cool place.

Troubleshooting

ENGLISH

Failure Possible causesTroubleshooting
The operation indicator doesn’t light up, no mist releaseNo voltage, no power supplyConnect the unit to the mains
Plug another, certainly operating appliance to the socket to make sure that the socket works properly
No mist release Water tankis empty Fill the water tank with water
Mist smells unpleasantly FFirst use of the unit Removethe water tank lid, pour out the water and leave the tank open for 12 hours in a cool darkened place
Dirty or stale water Unplug the unit, remove the water tank, pour out the water, wash the tank and fill it with clean or distilled water
Low mist release intensity Sprayer is dirty Unplug the unit and clean the sprayer
Foreign noise is heard during the operation of the humidifierThe unit is placed on an uneven or unstable surfaceUnplug the unit and level the unit body or set it in another place

Note:

Non-observance of rules for cleaning the sprayer from mineral deposits may affect the overall performance of the unit. In this case clean the unit. If used tap water is too hard, use water filters to clean water or mix it with distilled water in proportion 1:1.

Delivery set

Air humidifier -1 pc.

Removable water tank - 1 pc.

Removable water tank lid - 1 pc.

Instruction manual - 1 pc.

Technical specifications

Power supply: 220-240 V, \~ 50 Hz

Power consumption: 140 W

Water tank capacity: 5 L

Water flow: 300 ml/h

Humidified area: up to 50 m ^4

The manufacturer preserves the right to change the design and the specifications of the unit without a preliminary notification.

Unit operating life is 5 years

Guarantee

Details regarding guarantee conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.

Vitek VT-1767 BK - Guarantee - 1

This product conforms to the EMC-Requirements as laid down by the Council Directive 89/336/EEC and to the Low Voltage Regulation (73/23 EEC)

DEUTSCH

LUFTBEFEUCHTER

Beschreibung

A production date of the item is indicated in the serial number on the technical data plate. A serial number is an eleven-unit number, with the first four figures indicating the production date. For example, serial number 0606xxxxxxx means that the item was manufactured in June (the sixth month) 2006.

DE

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Vitek

Model : VT-1767 BK

Category : Humidifier