| Product Type | Ultrasonic Humidifier |
| Model | VT-1760 W |
| Brand | Vitek |
| Water Tank Capacity | 4.0 L |
| Mist Output | 300 mL/h |
| Coverage Area | Up to 30 m² |
| Power Supply | AC 220-240 V, 50 Hz |
| Power Consumption | 25 W |
| Noise Level | ≤ 35 dB |
| Dimensions (W x D x H) | 220 x 200 x 330 mm |
| Weight | 1.5 kg |
| Color | White |
| Mist Adjustment | Adjustable (Low/Medium/High) |
| Auto Shut-Off | Yes, when water tank empty |
| Water Level Indicator | Yes, transparent tank |
| Filter Type | Demineralization cartridge (replaceable) |
| Cleaning | Descale regularly with vinegar or citric acid |
| Replacement Parts | Filter cartridge and atomizer available |
| Safety Features | Overheat protection, auto shut-off |
| Certification | CE, RoHS |
| Warranty | 2 years |
Frequently Asked Questions - VT-1760 W Vitek
User questions about VT-1760 W Vitek
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Humidifier in PDF format for free! Find your manual VT-1760 W - Vitek and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. VT-1760 W by Vitek.
USER MANUAL VT-1760 W Vitek
ENGLISH
AIR HUMIDIFIER
Description
- On/Off illumination button
- On/Off knob (OFF/ON)/ mist release intensity control
- Illumination
- Front panel
- Lid with a mist release opening
- Water tank
- Water inlet
- Filter-cartridge
- Water tank lid
- Sprayer
- Humidifier body
- On/no water indication
- Cleaning brush
SAFETY MEASURES
Before using the air humidifier, please read this instruction carefully and keep it for the whole operation period.
- Before switching on make sure that voltage of the electric network corresponds to unit operating voltage.
- Place the unit on a flat, moisture-resistant surface. Distance to the walls should be at least 15 cm.
- Do not place the humidifier in places exposed to direct sunlight, high temperatures, near computers or other sensitive electronic appliances.
- Do not leave the unit unattended in a closed room, this can lead to appearance of condensation on furniture and walls. That's why we recommend keeping the door of the room, where the humidifier is used, half-opened.
- Do not use the unit outdoors.
- Use only removable parts supplied with the unit.
- For children safety do not leave polyethylene bags, used as a packaging, unattended.
Attention! Do not allow children to play with polyethylene bags and film. Danger of suffocation!
- Keep the unit out of reach of children.
- Do not allow children to use the unit as a toy.
- This unit is not intended for usage by children or disabled persons unless they are given all the necessary instructions by a person who
is responsible for their safety on safety measures and information about danger that can be caused by improper usage of the unit.
- Do not switch on the humidifier without water, disconnect the unit from the power supply when the water tank becomes empty.
- Do not use soda water or any perfume additives
- Unplug the unit before removing the water tank.
- Do not cover the mist release openings and avoid getting of foreign objects into them.
- Do not immerse the unit, the power plug or the power cord into water or other liquids.
- Do not move or tilt the unit during its operation.
- Always unplug the unit and pour out water from the water tank before cleaning and if you do not use the humidifier.
- Unplug the humidifier before moving it to another place.
- Do not touch the power plug with wet hands.
- Before using the unit, examine the power cord closely and make sure that it is not damaged. Do not use the unit if the power cord is damaged.
- Do not dismantle the humidifier by yourself, if any malfunction is detected, apply to the nearest authorized service center.
- Regularly clean the unit; do not allow scratches appear on the sprayer.
- Unpack the unit and remove package materials. Examine the humidifier for damages. Do not switch on the humidifier in case of damages.
Note:
- If the unit was exposed to negative temperatures, keep it at room temperature for 30 minutes before switching it on for the first time.
- Use the unit at the room temperature from +5^ to +40^ , and relative humidity less than 80% .
- Water temperature should not exceed +40°C.
ENGLISH
- Before switching on the humidifier make sure that the voltage of electric network corresponds to the unit operating voltage.
Usage of the unit
- Remove the lid (5) from the water tank (6).
- Remove the water tank (6) from the unit body.
- Turn over the tank (6), open the lid (9) rotating it counterclockwise.
- Fill the tank (6) with necessary amount of water, close the lid (9) rotating it clockwise.
- Place the filled water tank (6) on the unit body.
- Insert the plug into the socket.
- Switch on the humidifier, turning the knob (2) clockwise, the operation indicator (12) will become blue.
- Set the mist release intensity turning the knob (2).
- You can switch on the illumination (3) by pressing the button (1), for example, at night-time.
- If the water tank (6) is empty, the indicator (12) will become red.
- In this case switch off the unit by setting the knob (2) to «OFF» position, the indicator (12) will go out, then unplug the unit. Fill the tank (6) with water, install it to its place and switch on the unit.
- After the humidifier finishes operation, switch it off by setting the knob (2) to «OFF» position, the indicator (12) will go out.
Cleaning and care
Attention! Always switch off and unplug the unit before cleaning.
- Hard water causes the appearance of mineral scale on the sprayer, on the inner parts of the body and in the water tank; it leads to improper operation of the humidifier and appearance of white deposits on interior objects.
- To avoid this it is necessary to clean the sprayer weekly and change water as often as possible, as well as to perform cleaning of the filter-cartridge.
- If you are not going to use the humidifier for a long time, pour out water from the tank and the operating chamber of the sprayer, wash the water tank, wash and clean the operating
chamber of the sprayer and the sprayer itself, dry the unit and take it away for storage.
Weekly care
- Once a week wash the water tank (6) and the operating chamber under the tank (6) carefully with a neutral detergent solution.
- Then carefully rinse them with water.
- Add 5-10 drops of the detergent on the sprayer (10); wait about 2-5 minutes. Remove the deposit from the sprayer (10) with a brush (13).
Note: As a cleaning agent for the sprayer you can use scale removal substances for kettles.
- Do not immerse the humidifier body into water or other liquids.
Filter cleaning
- Clean the filter (8) after passing of about 500 l water through it, and more often, if using hard water or a white deposits appear on furniture,.
- Remove the lid (5) from the water tank (6) and remove the tank (6) from the unit body (11).
- Turn over the tank (6), open the lid (9) rotating it counterclockwise, remove the filter-cartridge (8), rotating it counterclockwise.
- Put the filter-cartridge (8) into a container with vinegar for 10 minutes, then take it out and rinse with running water.
- Install the filter-cartridge (8) back into the lid (9), rotating it clockwise.
Storage
- If you are not going to use the humidifier for a long time, make sure that all its parts are dry, including the operating chamber of the sprayer.
- Do not store the unit with water in the water tank and in the operating chamber of the sprayer.
- Clean and dry the filter-cartridge before taking it away for storage. Keep the filter-cartridge in a cool darkened place.
Keep the humidifier away from children in a dry cool place.
Troubleshooting
| Failure | Possible causes | Troubleshooting |
| The operation indicator doesn’t light up, no mist release | No voltage, no power supply | Connect the unit to the mains. |
| Plug another, certainly operating appliance to the socket to make sure that the socket works properly. |
ENGLISH
| The operation indicator flashes red, no mist release | Water tank is empty Fill the water tank with water | |
| Mist smells unpleasantly | First use of the unit | Remove the water tank lid, pour out water and leave the tank open for 12 hours in a cool darkened place |
| Dirty or stagnant water | Unplug the unit, remove the water tank, pour out the water, wash the tank and fill it with clean boiled or distilled water | |
| Low mist release intensity | Sprayer is dirty | Unplug the unit and clean the sprayer. |
| Foreign noise is heard during the operation of the humidifier | The unit is placed on an uneven or unstable surface. | Unplug the unit and level the unit body or set in another place. |
Note:
Non-observance of rules for cleaning the sprayer from mineral deposits may affect the overall performance of the unit. In this case clean the unit. If used tap water is too hard, use water filters to clean the water or mix it with distilled water in proportion 1:1
DELIVERY SET
Air humidifier - 1 pc.
Removable lid with nozzle - 1 pc.
Removable water tank - 1 pc.
Removable water tank lid - 1 pc.
Instruction manual - 1 pc.
TECHNICAL SPECIFICTAIONS
Power supply: 220-240 V, \~ 50 Hz
Power consumption: 30 W
Water tank capacity: 3 L
Water flow: 250 ml/h
Humidified area: up to 25 m²
The manufacturer preserves the right to change the design and the specifications of the unit without a preliminary notification.
Unit operating life is 5 years
Guarantee
Details regarding guarantee conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.

This product conforms to the EMC-Requirements as laid down by the Council Directive 89/336/EEC and to the Low Voltage Regulation (73/23 EEC)
DEUTSCH
LUFTBEFEUCHTER
Beschreibung
A production date of the item is indicated in the serial number on the technical data plate. A serial number is an eleven-unit number, with the first four figures indicating the production date. For example, serial number 0606xxxxxxx means that the item was manufactured in June (the sixth month) 2006.