Product Type Ultrasonic Humidifier
Model VT-1760 W
Brand Vitek
Water Tank Capacity 4.0 L
Mist Output 300 mL/h
Coverage Area Up to 30 m²
Power Supply AC 220-240 V, 50 Hz
Power Consumption 25 W
Noise Level ≤ 35 dB
Dimensions (W x D x H) 220 x 200 x 330 mm
Weight 1.5 kg
Color White
Mist Adjustment Adjustable (Low/Medium/High)
Auto Shut-Off Yes, when water tank empty
Water Level Indicator Yes, transparent tank
Filter Type Demineralization cartridge (replaceable)
Cleaning Descale regularly with vinegar or citric acid
Replacement Parts Filter cartridge and atomizer available
Safety Features Overheat protection, auto shut-off
Certification CE, RoHS
Warranty 2 years

Frequently Asked Questions - VT-1760 W Vitek

How often should I clean the humidifier?
It is recommended to clean the water tank and atomizer at least once a week. Use a mixture of water and white vinegar or a descaling solution to remove mineral deposits.
Can I use tap water in the humidifier?
Yes, but using distilled or demineralized water reduces mineral buildup and extends the life of the filter and atomizer. Tap water may cause white dust.
Why is the humidifier not producing mist?
Check if the water tank is empty, the unit is level, or the atomizer is dirty. Clean the atomizer and ensure the water level is above the minimum.
How do I replace the filter?
Turn off and unplug the unit. Remove the water tank, open the filter compartment, and replace the old demineralization cartridge with a new one. Reassemble and run a rinse cycle.
Can the humidifier be used with essential oils?
No, this model is not designed for essential oils. Adding oils can damage the plastic parts and void the warranty.
What is the recommended humidity level?
For comfort and health, maintain indoor humidity between 40% and 60%. Use a hygrometer to monitor levels.
How long does the humidifier run on a full tank?
At maximum mist output, the 4-liter tank lasts approximately 13 hours. At lower settings, it can run up to 20 hours.
Is the humidifier safe for babies?
Yes, the ultrasonic operation is quiet and safe. Place it out of reach of children and use cool mist to avoid burns. Ensure regular cleaning to prevent bacterial growth.
What does the auto shut-off feature do?
The humidifier automatically turns off when the water tank is empty or if it tips over, preventing damage and ensuring safe operation.
How do I troubleshoot if the unit makes noise?
Check if the unit is level on a flat surface. A gurgling sound is normal during operation; if loud, ensure the water tank is properly seated and the atomizer is clean.

User questions about VT-1760 W Vitek

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Humidifier in PDF format for free! Find your manual VT-1760 W - Vitek and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. VT-1760 W by Vitek.

USER MANUAL VT-1760 W Vitek

ENGLISH

AIR HUMIDIFIER

Description

  1. On/Off illumination button
  2. On/Off knob (OFF/ON)/ mist release intensity control
  3. Illumination
  4. Front panel
  5. Lid with a mist release opening
  6. Water tank
  7. Water inlet
  8. Filter-cartridge
  9. Water tank lid
  10. Sprayer
  11. Humidifier body
  12. On/no water indication
  13. Cleaning brush

SAFETY MEASURES

Before using the air humidifier, please read this instruction carefully and keep it for the whole operation period.

  • Before switching on make sure that voltage of the electric network corresponds to unit operating voltage.
  • Place the unit on a flat, moisture-resistant surface. Distance to the walls should be at least 15 cm.
  • Do not place the humidifier in places exposed to direct sunlight, high temperatures, near computers or other sensitive electronic appliances.
  • Do not leave the unit unattended in a closed room, this can lead to appearance of condensation on furniture and walls. That's why we recommend keeping the door of the room, where the humidifier is used, half-opened.
  • Do not use the unit outdoors.
  • Use only removable parts supplied with the unit.
  • For children safety do not leave polyethylene bags, used as a packaging, unattended.

Attention! Do not allow children to play with polyethylene bags and film. Danger of suffocation!

  • Keep the unit out of reach of children.
  • Do not allow children to use the unit as a toy.
  • This unit is not intended for usage by children or disabled persons unless they are given all the necessary instructions by a person who

is responsible for their safety on safety measures and information about danger that can be caused by improper usage of the unit.

  • Do not switch on the humidifier without water, disconnect the unit from the power supply when the water tank becomes empty.
  • Do not use soda water or any perfume additives
  • Unplug the unit before removing the water tank.
  • Do not cover the mist release openings and avoid getting of foreign objects into them.
  • Do not immerse the unit, the power plug or the power cord into water or other liquids.
  • Do not move or tilt the unit during its operation.
  • Always unplug the unit and pour out water from the water tank before cleaning and if you do not use the humidifier.
  • Unplug the humidifier before moving it to another place.
  • Do not touch the power plug with wet hands.
  • Before using the unit, examine the power cord closely and make sure that it is not damaged. Do not use the unit if the power cord is damaged.
  • Do not dismantle the humidifier by yourself, if any malfunction is detected, apply to the nearest authorized service center.
  • Regularly clean the unit; do not allow scratches appear on the sprayer.

- Unpack the unit and remove package materials. Examine the humidifier for damages. Do not switch on the humidifier in case of damages.

Note:

  • If the unit was exposed to negative temperatures, keep it at room temperature for 30 minutes before switching it on for the first time.
  • Use the unit at the room temperature from +5^ to +40^ , and relative humidity less than 80% .
  • Water temperature should not exceed +40°C.

ENGLISH

- Before switching on the humidifier make sure that the voltage of electric network corresponds to the unit operating voltage.

Usage of the unit

  1. Remove the lid (5) from the water tank (6).
  2. Remove the water tank (6) from the unit body.
  3. Turn over the tank (6), open the lid (9) rotating it counterclockwise.
  4. Fill the tank (6) with necessary amount of water, close the lid (9) rotating it clockwise.
  5. Place the filled water tank (6) on the unit body.
  6. Insert the plug into the socket.
  7. Switch on the humidifier, turning the knob (2) clockwise, the operation indicator (12) will become blue.
  8. Set the mist release intensity turning the knob (2).
  9. You can switch on the illumination (3) by pressing the button (1), for example, at night-time.
  10. If the water tank (6) is empty, the indicator (12) will become red.
  11. In this case switch off the unit by setting the knob (2) to «OFF» position, the indicator (12) will go out, then unplug the unit. Fill the tank (6) with water, install it to its place and switch on the unit.
  12. After the humidifier finishes operation, switch it off by setting the knob (2) to «OFF» position, the indicator (12) will go out.

Cleaning and care

Attention! Always switch off and unplug the unit before cleaning.

  • Hard water causes the appearance of mineral scale on the sprayer, on the inner parts of the body and in the water tank; it leads to improper operation of the humidifier and appearance of white deposits on interior objects.
  • To avoid this it is necessary to clean the sprayer weekly and change water as often as possible, as well as to perform cleaning of the filter-cartridge.
  • If you are not going to use the humidifier for a long time, pour out water from the tank and the operating chamber of the sprayer, wash the water tank, wash and clean the operating

chamber of the sprayer and the sprayer itself, dry the unit and take it away for storage.

Weekly care

  1. Once a week wash the water tank (6) and the operating chamber under the tank (6) carefully with a neutral detergent solution.
  2. Then carefully rinse them with water.
  3. Add 5-10 drops of the detergent on the sprayer (10); wait about 2-5 minutes. Remove the deposit from the sprayer (10) with a brush (13).

Note: As a cleaning agent for the sprayer you can use scale removal substances for kettles.

- Do not immerse the humidifier body into water or other liquids.

Filter cleaning

  1. Clean the filter (8) after passing of about 500 l water through it, and more often, if using hard water or a white deposits appear on furniture,.
  2. Remove the lid (5) from the water tank (6) and remove the tank (6) from the unit body (11).
  3. Turn over the tank (6), open the lid (9) rotating it counterclockwise, remove the filter-cartridge (8), rotating it counterclockwise.
  4. Put the filter-cartridge (8) into a container with vinegar for 10 minutes, then take it out and rinse with running water.
  5. Install the filter-cartridge (8) back into the lid (9), rotating it clockwise.

Storage

  • If you are not going to use the humidifier for a long time, make sure that all its parts are dry, including the operating chamber of the sprayer.
  • Do not store the unit with water in the water tank and in the operating chamber of the sprayer.
  • Clean and dry the filter-cartridge before taking it away for storage. Keep the filter-cartridge in a cool darkened place.

Keep the humidifier away from children in a dry cool place.

Troubleshooting

FailurePossible causesTroubleshooting
The operation indicator doesn’t light up, no mist releaseNo voltage, no power supplyConnect the unit to the mains.
Plug another, certainly operating appliance to the socket to make sure that the socket works properly.

ENGLISH

The operation indicator flashes red, no mist releaseWater tank is empty Fill the water tank with water
Mist smells unpleasantlyFirst use of the unitRemove the water tank lid, pour out water and leave the tank open for 12 hours in a cool darkened place
Dirty or stagnant waterUnplug the unit, remove the water tank, pour out the water, wash the tank and fill it with clean boiled or distilled water
Low mist release intensitySprayer is dirtyUnplug the unit and clean the sprayer.
Foreign noise is heard during the operation of the humidifierThe unit is placed on an uneven or unstable surface.Unplug the unit and level the unit body or set in another place.

Note:

Non-observance of rules for cleaning the sprayer from mineral deposits may affect the overall performance of the unit. In this case clean the unit. If used tap water is too hard, use water filters to clean the water or mix it with distilled water in proportion 1:1

DELIVERY SET

Air humidifier - 1 pc.

Removable lid with nozzle - 1 pc.

Removable water tank - 1 pc.

Removable water tank lid - 1 pc.

Instruction manual - 1 pc.

TECHNICAL SPECIFICTAIONS

Power supply: 220-240 V, \~ 50 Hz

Power consumption: 30 W

Water tank capacity: 3 L

Water flow: 250 ml/h

Humidified area: up to 25 m²

The manufacturer preserves the right to change the design and the specifications of the unit without a preliminary notification.

Unit operating life is 5 years

Guarantee

Details regarding guarantee conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.

Vitek VT-1760 W - Guarantee - 1

This product conforms to the EMC-Requirements as laid down by the Council Directive 89/336/EEC and to the Low Voltage Regulation (73/23 EEC)

DEUTSCH

LUFTBEFEUCHTER

Beschreibung

A production date of the item is indicated in the serial number on the technical data plate. A serial number is an eleven-unit number, with the first four figures indicating the production date. For example, serial number 0606xxxxxxx means that the item was manufactured in June (the sixth month) 2006.