RCLK-C380GB - Fridge Royal Catering - Free user manual and instructions
Find the device manual for free RCLK-C380GB Royal Catering in PDF.
User questions about RCLK-C380GB Royal Catering
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Fridge in PDF format for free! Find your manual RCLK-C380GB - Royal Catering and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RCLK-C380GB by Royal Catering.
USER MANUAL RCLK-C380GB Royal Catering
natural_image
Silhouette of a lion-like creature on a blue background (no text or symbols)| Deutsch | 3 |
| English | 10 |
| Polski | 17 |
| Česky | 25 |
| Français | 32 |
| Italiano | 39 |
| Español | 46 |
| Magyar | 53 |
| Dansk | 60 |
| PRODUKTNAME | GLASTURKUHLSCHRANK | LAGER-KUHLSCHRANK | GEFFIERSCHRANK |
| PRODUCT NAME | CHILLER | CHILLER | FREEZER |
| NAZWA PRODUKTU | CHLODZIARKA ZE SZKLANYMI DRZWAMI | CHLODZIARKA | ZAMRAZARKA |
| NAZEV VYROBKU | CHLADNIČKA SE SKLENĚNYMI DVERMI | CHLADNIČKA | MRAZNIČKA |
| NOM DU PRODUIT | PORTE EN VERRE DE REFRIGÉRATEUR | RETRIGÉRATEUR DE STOCKAGE | CONGELATEUR |
| NOME DEL PRODOTTO | VETRINA FRIGO | FRIGORIFERO | CONGELATORE |
| NOMBRE DEL PRODUCTO | PUERTA DE CRISTAL PARA FRIGÓRÍFICO | FRIGORÍFICO | CONGELADOR |
| TERMĚK NEVE | HÚTÓGĚP ÚVEGAJTÓVAL | HÚTÓGĚP | FAGYASZTÓ |
| PRODUKTNAVN | KOLESKAB MED GLASDÓR | KOLESKAB | FRYSER |
| MODELL | RCLK-F590S | ||
| PRODUCT MODEL | RCGK-W200 | RCLK-W800 | RCLK-F590-G |
| MODEL PRODUKTU | RCLK-C590GB | RCLK-F590GB | |
| MODEL VYROBKU | RCLK-C590 | RCLK-F590 | |
| MODELT | RCLK-C580GB | RCLK-F380S | |
| MODELLO | RCLK-C580G | RCLK-F380G | |
| MODELO | RCLK-C170 | RCLK-F380GB | |
| MODEL | RCLK-F380 | ||
| HERSTELLER | RCLK-F170S | ||
| MANUFACTURER | EXPONDO POLSKA SP. Z O.O. SP. K. | ||
| PRODUCENT | |||
| VÝROBCE | |||
| FABRICANT | |||
| PRODUTTORE | |||
| FABRICANTE | |||
| TERMELÓ | |||
| PRODUCENT | |||
| ANSCHIRIFT DES HERSTELLERS | UL, NOWY KISIELIN-INNOWACYJNA 7, 66002 ZIELONA GÓRA | POLAND, EU | ||
| MANUFACTURER ADDRESS | |||
| ADRES PRODUCENTA | |||
| ADRESA VÝROBCE | |||
| ADRESSE DU FABRICANT | |||
| INDIRIZZO DEL PRODUTTORE | |||
| DIRECCIÓN DEL FABRICANT | |||
| A GYÁRTO CIME | |||
| PRODUCENTENS ADRÈSSE | |||
text_image
Diagram of two refrigerator units with numbered labels pointing to different interior compartmentsModell RCGK W200, RCKG W400, RCLK F590 G.
RCLK-F590GB, RCLK-F380G, RCLK-F380GB, RCLK-C590GB
The operation manual must be reviewed.
Never dispose of electrical equipment together with household waste.

This machine conforms to the CE declarations.

ATTENTION! Risk of accident

WARNING: Risk of fire. Isobutene Isobutene.

ATTENTION! Electric shock warning!
Only use indoors

PLEASE NOTE! Drawings in this manual are for illustration purposes only and in some details it may differ from the actual machine.
The original operation manual is in German. Other language versions are translations from German.
USER MANUAL
SAFETY INSTRUCTIONS
General safety information for the use of electrical devices. To avoid any risk of injury from fire or electric shock, please follow the basic safety instructions when using this device. Please read the instructions carefully and make sure that you have understood them well. Keep the manual near the equipment to be able to read it at any time. Always use current sources connected to the ground that provide the correct voltage (indicated on the label on the device), if you have any doubts let an electrician check that the connection is properly grounded. Never use a defective power cable. Do not open the unit in damp or wet environment, or if your hands or body arc damp or wet Protect the unit from solar radiation. Use the device in a protected place to avoid damaging the equipment or putting at risk others. Make sure the device is able to cool and avoid placing it too close to other devices that produce heat. Before cleaning the machine, disconnect it from the power source. Use a soft damp cloth for cleaning. Avoid using detergents and make sure that no liquid enters the unit. No internal element of this device needs to be maintained by the user. Opening the device without our approval leads to a loss of warranty.
SAFETY GUIDELINES
- Please read and understand these instructions carefully before using the device! Please observe the safety guidelines carefully in order to prevent damages through improper use!
- Please keep this manual available for future reference. If this device is passed on to third parties, the manual must be passed on with it.
- Only use this device indoors and for its intended use.
- We do not offer any warranty for damages resulting from improper use or incorrect operation.
- Before using this device for the first time, please check whether the main voltage type and current comply with the indicated data on the type plate.
-
This device is not intended to be used by persons (including children) with limited physical, sensory or mental capabilities or lack of experience and/or knowledge, unless they are supervised by a person responsible for their safety or have received instruction as to how the device is used.
-
ELECTRIC SHOCK HAZARDI Do not try to repair the unit yourself. In case of device failures, repairs must be done by qualified experts.
- Please check the main plug and the power cable regularly. If the power cable for this device is damaged, it has to be replaced by the manufacturer or its customer service or another qualified person in order to prevent hazards.
- It is necessary to prevent damage to the power table due to its crushing, breaking or abrasions on sharp edges and to keep it away from hot surfaces and open sources of fire. It may also not hang or be immersed in water.
- ATTENTION! DANGER TO LIFE! While cleaning, never immerse the device in water or other liquids.
- Under no circumstances should the housing be opened.
- Do not store heavy, poisonous or corrosive objects in the device.
- In order to avoid damaging the compressor during transport, the fridge should not be tilted by more than 45°
- Do not use the appliance in unheated rooms and in locations with high air humidity.
- ATTENTION! The ventilation openings of the appliance should always be free from blockages.
- ATTENTION! Do not use any electrical appliances or machines in order to accelerate defrosting.
- ATTENTION! Pay special attention not to damage the elements of coolant circuit.
- ATTENTION! Do not use any electrical appliances inside the chamber of the appliance which serves to store food.
- ATTENTION! The appliance in its design contains flammable gases serving for insulation. For this reason at the end of its service life the appliance should be handed over for disposal by professionals.
- ATTENTION: The plug of the appliance should be connected to the socket in a place enabling its easy and quick disconnection.
- ATTENTION! Installation of the appliance must be carried out by a qualified person.
- Children may not play with the appliance.
- It is not allowed to store potentially explosive substances in the appliance, e.g., cans containing compressed flammable gas.
- Do not use malfunctioning or damaged device.
- Parts or accessories not recommended by the manufacturer cannot be used in the device. The act of using parts not recommended by the manufacturer, resulting in loss of warranty and can lead to a direct threat to the life or health of the user.
- It is forbidden to move, adjusting and rotating the device in the course of work.
- It is forbidden to place the device on a combustible surface.
- It is forbidden to place the device near an open flame, electric stoves, coal stoves or other heat sources, as well as near direct sunlight. High temperatures can damage the cooling capacity and rise the consumption of electricity.
-
The device must not be connected to the outlet other than wall-mounted socket, do not use a multiple outlet adapter or multiple sockets.
-
In case the power supply is cut off from the appliance it is necessary to wait about 5 minutes before reconnecting the appliance to the electricity in order to avoid damage to the appliance.
-
Do not expose the device to rain.
-
Do not place any containers with liquids that can freeze in the freezer.
Failure to follow safety recommendations and instructions may result in serious injuries or death!
TECHNICAL DATA
| Product name | Chiller | Chiller | |
| Model | RCGK-W200 | RCGK-W400 | RCLK-W600 |
| Rated input power [W] | 180 | 215 | 235 |
| Rated current [A] | 1,4 | 2 | |
| Power consumption [kWh/24h] | 1,5 | 1,7 | 1,5 |
| Energy class | B | C | |
| Power supply [V]/ Frequency [Hz] | 230-/50 | ||
| Refrigerant | R600a/ 54g | R600a/ 128g | R600a/145g |
| Temperature (°C) | 0~8 | ||
| Net volume (l) | - | - | 376 |
| Gross volume (l) | 170 | 391 | 590 |
| Electric shock protection class | 1 | ||
| Emitted noise level | 39dB | 48,7dB | 43,4dB |
| AEC (Annual Energy Consumption) [kWh/Year] | 569 | 836 | 567 |
| Climate class | 4 | ||
| Weight [kg] | 45 | 73.5 | 89.3 |
| Dimensions [mm] | 595x680 x870 | 680x600 x1870 | 725x777 x1885 |
| Height adjustment | Yes | ||
| Basket/shelves | 3 shelves | 4 shelves | |
| Lock | Yes | ||
| Product name | Freezer | ||
| Model | RCLK-F590S | RCLK-F590-G | RCLK-F590GB |
| Rated input power [W] | 492 | ||
| Rated current [A] | 2,8 | - | |
| Power consumption [kWh/24h] | 6.2 | - | |
| Energy class | D | C | |
| Power supply [V]/ Frequency [Hz] | 230~/50 | ||
| Refrigerant | R290 / 110g | ||
| Temperature [°C] | -22÷ -18 | -22÷ -13 | |
| Net volume [l] | 321 | - | |
| Gross volume [l] | 590 | ||
| Electric shock protection class | I | ||
| AEC (Annual energy Consumption) [kWh/Year] | 2260 | 3015 | |
| Climate class | 4 | ||
| Weight [kg] | 105 | 127 | 123 |
| Dimensions [mm] | 775x723 x1850 | 775x705 x1850 | |
| Height adjustment | Yes | ||
| Baskct/shelves | 7 shelves | ||
| Lock | Yes | ||
| Product name | Freezer | ||
| Model | RCLK-F590 | RCLK-F380S | RCLK-F380G |
| Rated input power [W] | 492 | 425 | |
| Rated current [A] | 2,8 | 2,6 | - |
| Power consumption [kWh/24h] | 3,2 | 5,0 | - |
| Energy class | D | C | |
| Power supply [V]/ Frequency [Hz] | 230~/50 | ||
| Refrigerant | R290 / 110g | R290 / 120g | |
| Temperature [°C] | 22: -16 | 13: -21 | |
| Net volume [l] | 321 | 206 | - |
| Gross volume [l] | 590 | 380 | |
| Electric shock protection class | I | ||
| AEC (Annual Energy Consumption) [kWh/Year] | 2260 1816 2237 | ||
| Climate class 4 | |||
| Weight [kg] 105 89 102 | |||
| Dimensions [mm] 775x723 x1850 | 595x653 x1850 | 595x635 x1850 | |
| Height adjustment Yes | |||
| Basket/shelves 7 shelves | |||
| Lock | Yes | ||
| Product name | Freezer | ||
| Model | RCLK-F380GB | RCLK-F380 | RCLK-F170S |
| Rated input power [W] | 425 | 215 | |
| Rated current (A) | - | 2.6 | 2 |
| Power consumption [kWh/24h] | - | 4.9 | - |
| Energy class | C | D | - |
| Power supply [V] Frequency [Hz] | 230~750 | ||
| Refrigerant | R290 / 120g | R600a/65g | |
| Temperature [°C] | -13+ -21 | -22+ -18 | -20+ -18 |
| Net volume [l] | - | 200 | - |
| Gross volume [l] | 380 | 170 | |
| Electric shock protection class | I | ||
| AEC (Annual Energy Consumption) [kWh/Year] | 2237 1816 | ||
| Climate class 4 | |||
| Weight [kg] 101 | 85 | 46 | |
| Dimensions [mm] | 595x635 x1850 595x653 x860 | ||
| Height adjustment Yes | |||
| Basket/shelves | 7 shelves | 3 shelves | |
| Lock | Yes | ||
| Product name | Chiller | ||
| Model | RCLK-C590GB | RCLK-C590 | RCLK-C380GB |
| Rated input power [W] | 228 | 215 | |
| Rated current [A] - | |||
| Power consumption [kWh/24h] | - | ||
| Energy class | B | D | B |
| Power supply [V]/ Frequency [Hz] | 230~/50 | ||
| Refrigerant | R600a/145g | R600a/ 100g | |
| Temperature [°C] 0~5 | 0~8 | 0~5 | |
| Net volume [l] | - | 376 | - |
| Gross volume [l] | 590 | 380 | |
| Electric shock protection class | I | ||
| ASC (Annual Energy Consumption) kWh/Year | 1296 | 896 | 1071 |
| Climate class 4 | |||
| Weight [kg] | 95 | 89 | 78 |
| Dimensions [mm] 775x705 x1850 | 775x723 x1850 | 595x635 x1850 | |
| Height adjustment Yes | |||
| Basket/shelves 4 shelves | |||
| Lock | Yes | ||
| Product name | Chiller | ||
| Model | RCLK-C380G | RCLK-C170 | |
| Rated input power [W] | 215 | 187 | |
| Rated current [A] | - | 1.4 | |
| Power consumption [kWh/24h] | - | - | |
| Energy class | D | - | |
| Power supply [V]/ Frequency [Hz] | 230~/50 | ||
| Refrigerant | R600a/ 100g | R600a/ 54g | |
| Temperature [°C] | 0~8 | 0~8 | |
| Net volume [l] | 239 | - | |
| Gross volume [l] | 380 | 170 | |
| Electric shock protection class | 1 | |
| AEC (Annual Energy Consumption) [kWh/Year] | 603 | - |
| Climate class | 4 | |
| Weight [kg] | 75 | 43 |
| Dimensions [mm] 595x635 x1850 | 595x653 x860 | |
| Height adjustment | Ja | |
| Basket/shelves | 4 shelves | 3 shelves |
| Lock | Ja | |
SCOPE OF THE APPLICATION
The chillers are designed for refrigerating and storing food. The freezers are intended for freezing and frozen storage of food.
The user is liable for any damage resulting from nonintended use of the device!
BEFORE THE FIRST USE
Upon receipt of the goods, check the packaging for defects and open the packaging if there are no damages. If the packaging is damaged, please contact your transport company and distributor within 3 days, and document the damages as detailed as possible. Do not turn the package upside down! When transporting the package, please ensure that it is kept horizontal and stable.
DISPOSING OF THE PACKAGING
Please keep all packaging materials (cardboard, plastic tapes and Styrofoam), so that in case of a problem, the device can be sent back to the service centre in accurate condition!
GENERAL HINTS FOR THE USER
The appliance must be cleaned after unpacking and before its connection to the power supply network. Once the appliance has reached the set temperature, it can be filled. It is forbidden to fill the appliance with warm liquids and food and any food products put into the appliance should be covered. Food products and drinks should be stored in sealed airtight containers. In order to ensure adequate air circulation inside the appliance it is recommended to place products be in such a manner in order to maintain distance between them. If the door is opened too often, there is increased energy consumption, which could lead to possible damage. Maximum loading of a single shelf 30 kg. Always close the door of the appliance when it is not in use. Do not use screwdrivers or other metal tools in order to remove ice layers that are formed on the walls of the appliance during its use. In case of you do not use the appliance for a longer time, in order to save electricity, it is necessary to disconnect the cleaned appliance from the electricity to clean and leave the door open in order to prevent gathering of unpleasant odours inside the appliance.
DEVICE DESCRIPTION RCGK-W200
RCGK-W400, RCLK-F590-G, RCLK-F590GB, RCLK-F380G, RCLK-F380GB, RCLK-C590GB

text_image
Diagram of two refrigerator units with numbered labels pointing to each panel-
Backlight or/off button
-
Lock
-
Control panel
-
Glass doc
-
Schelves
- Adjustable feet
RCLK-W600, RCLK-F590S, RCLK-F590, RCLK-F380S, RCLK F380, RCLK F170S, RCLK C590, RCLK C380G, RCLK-C170

text_image
1. Lock 2. Control panel 3. Door 4. Adjustable feetAll models come with two wheels in the rear part of the device to facilitate moving to another position.
INSTALLATION AND ASSEMBLY OF THE APPLIANCE Always carry and transport the device in an upright position. Grab by the base. If the device was stored or transported in a position other than its working position, before use stand the device in the correct position for 12h. If there are any doubts, let it stand for the required period of time.
EN
EN
CAUTION! Correct connection of the device to the single socket with earth is the guarantee of proper work. In the case of inappropriate installation, the machine may cause injury. Place the appliance on a flat, stable surface that will withstand its weight together with its contents. In order to provide adequate ventilation, keep at least 20 cm of space between the appliance and the wall or other objects. Poor ventilation caused by insufficient space around the device may adversely impact the refrigeration process and reduce fridge lifetime.
First start up.
-
Unpack the whole appliance.
-
Make sure that no packing material has been left in the compressor chamber.
-
Remove all documents and other accessories from the inside of the appliance.
-
Install all additional components of the appliance.
-
Set the height and level the device.
-
Clean and dry the interior
-
Close the door of the appliance.
-
Connect the appliance plug to the socket.
-
Set refrigeration according to requirements.
-
Load the device once the pre-set temperature has been reached.
Height adjustment / levelling
In order to adjust the height or level of the chiller, it is necessary to unscrew or screw in the feet of the appliance.
FITTING SHELVES
-
Align one set of shelf brackets on each side of the interior at the required height.
-
Slide shelf into place
-
Repeat for the remaining shelves.
Shelf malignant is significant for correct water drainage
Assembling the outside panel:
Attach the outside panel to the lower part of the device, under the doors as shown on the diagram below:

SWITCHING THE DEVICE ON
Models RCGK-W200, RCKG-W400, RCLK-F590-G, RCLK F590GB, RCLK F380G, RCLK F380GB, RCLK C590GB
-
Close the appliance door
-
Make sure that the backlight on/off button is set to "O" and plug the appliance power cord into a mains outlet.
-
The appliance will start. See the control panel settings further in this manual.
-
You can turn the appliance backlight on and off with the backlight on/off button
RCLK-W600 model
-
Close device doors.
-
The device will start automatically once connected to a POWER SOURCE
The device will start refrigerating to the set temperature and will regularly run a defrost a few times a day depending on controller settings (usually every 4 hours).
DEFROSTING
AUTOMATIC DEEROST
The device shall require a defrost if internal ice build-up occurs. This may happen due to too frequent opening of the doors for long periods. The device automatically activates its auto defrost cycle every four hours. To manually activate defrost.
MANUAL DEFROST
Press and hold down the button for at least 5 seconds – defrost will start and an appropriate message will appear in the display. Defrost takes a maximum of 30 minutes. ATTENTION: Manual defrost resets the automatic defrost schedule. The next automatic defrost will start 4 hours after manual defrost ends.
ATTENTION! Do not use electrical devices (such as a hair dryer) or open fire to defrost the device. Plastic elements of the interior may melt and a spark or flame may ignite the fumes. The device floor includes an opening with a cap used to discharge larger quantities water outside of the device. Wipe dry small quantities of condensed water with a soft cloth or sponge.
DOOR LOCK
To prevent unauthorized opening the device doors may be locked.
| SET | Displaying settings. In service programming mode – select parameter and conform changes |
| Start manual defrost. | |
| Scroll list of parameters (in service programming model/ Increase set value | |
| Scroll list of parameters (in service programming model/ Decrease set value | |
| BUTTON COMBINATIONS | |
| Lock/unlock buttons | |
| SET+▽ | Initiate service programming mode = ATTENTION IT IS RECOMMENDED NOT TO INITIATE THE SERVICE MODE - all the factory parameters were set in this mode and changes may result in incorrect device operation. | |
| SET+△ | Return to ambient temperature display. | |
| SYMBOL | MODE DESCRIPTION | |
| ON Compressor is active | ||
| Flashing Prevention of short operation periods activated | ||
| ON Active defrosting | ||
| Flashing Active dripping | ||
| ON Fan ON | ||
| Flashing Delayed ventilator activation after defrosting | ||
| ○C | ON Unit of temperature | |
| Flashing Programming mode | ||
| °F | ON Unit of temperature | |
| Flashing Programming mode | ||
DISPLAYING SETTINGS
-
Briefly press the SET button and the current setting will be displayed.
-
To return to the standard screen briefly press SET or wait for approximately 5 seconds.
CHANGING SETTINGS
-
Press and hold down the SET button for approximately 3 seconds
-
The current setting will be displayed and °C or °F diode will flash
-
Change the setting using or
- To accept changes press the SET button.
LOCKING BUTTONS
Press and hold down the ▼ and △ buttons for at least 3 seconds. "OP" will be displayed – the buttons are now locked.
UNLOCKING BUTTONS
Press and hold down the ▼ and △ buttons for at least 3 seconds, "on" will be displayed – the buttons are now active.
TRANSPORTATION AND STORAGE
During transport, the machine should be protected from shaking, falling and turning upside down. Store it in a properly ventilated place with dry air and without any corrosive gas.
CLEANING AND MAINTENANCE
It is recommended to wash the appliance regularly. Before start of cleaning of the appliance or before performance of any repair or maintenance work, it is necessary to disconnect the appliance from the power supply and wait until it has cooled down. Do not use for washing any caustic cleaners, such as cleaning powders, agents with alcohol content, thinners, diluents, etc., and do not allow water to enter the appliance interior. Never immerse the appliance, cord or plug in water or any other liquid. It is forbidden to clean the device with a water jet. The interior of the device should be cleaned with a disinfectant suitable for the food industry. To clean, use a damp, soft cloth and then dry thoroughly. Dry the surface with a soft, dry cloth. The following actions should be taken if the machine is not used for a long period of time. Disconnect the appliance completely from the power supply and remove all food products from it. Then wash the entire appliance with a damp, soft cloth and mild cleaning agent, rinse with clean water and dry thoroughly, for some time leave the door open, so that the appliance will be completely dry. From time to time, check that the cable is not damaged. Do not use the appliance if the cable is damaged. A damaged cable must be replaced by a service or a qualified electrician. In the event of damage or malfunction, please contact your dealer or our service. Maintenance and repair work must be done only by qualified personnel using original spare parts and accessories. Attempts to make repairs on your own can lead to a direct threat to life or health, and will void the warranty!
CHECK REGULARLY THE DEVICE
Check regularly that the device doesn't present any damage. If there is any damage, please stop using the device. Please contact your customer service to solve the problem.
What to do in case of a problem?
Please contact your customer service and prepare following information:
• Invoice number and serial number (the latter is to be
found on the technical plate on the device).
- If relevant, a picture of the damaged, broken or defective part.
- It will be easier for your customer service clerk to determine the source of the problem if you give a detailed and precise description of the matter. The more detailed your information, the better the customer service will be able to answer your problem rapidly and efficiently!
CAUTION: Never open the device without the authorization of your customer service. This can lead to a loss of warranty!
TROUBLESHOOTING
| Problem | Probable cause | Action |
| The appliance is not working | The unit is not switched on | Check the unit is plugged in correctly and switched on |
| Plug and lead are damaged | Call your agent or qualified technician | |
| Fuse in the plug has blown | Replace the fuse | |
| Problem Probable cause Action | ||
| The appliance is not working | Power supply Check power supply | |
| Internal wiring fault C | Call your agent or qualified technician | |
| The appliance turns on, but the temperature is too high/ low | Too much ice on the evaporator | Defrost the appliance |
| Condenser blocked with dust | Call your agent or qualified technician | |
| Doors are not shut properly | Check doors are shut and seals are not damaged | |
| Appliance is located near a heat source or air flow to the condenser is being interrupted | Move the appliance to a more suitable location | |
| Ambient temperature is too high | Increase ventilation or move appliance to a cooler position | |
| Unsuitable foodstuffs are being stored in the appliance | Remove any excessive hot foodstuffs or blockages to the fan | |
| Appliance is overloaded | Reduce the amount of food stored in the appliance | |
| The appliance is unusually loud | Loose nut/screw Check | Check installation position and change if necessary |
| The appliance has not been installed in a level or stable position | ||
| The appliance is leaking water | The appliance is not properly levelled | Adjust the screw feet to level the appliance (if applicable) |
| The discharge outlet is blocked | Clear the discharge outlet | |
| Movement of water to the drain is obstructed | Clear the floor of the appliance (if applicable) | |
| The water container is damaged | Call your agent or qualified technician | |

text_image
Diagram of two refrigerator units with numbered labels pointing to different interior compartments1. Przycisk On/Off
text_image
Diagram of two refrigerator doors with numbered labels pointing to each interior panelModely RCGK-W200, RCKG-W400, RCLK-F590-G, RCLK-F590GB, RCLK-F380G, RCLK-F380GB, RCLK-C590GB
RCLK-F590GB, RCLK-F380G,
RCLK-F380GB, RCLK-C590GB

text_image
Diagram of two refrigerator units with numbered labels pointing to each paneltext_image
Diagram of two refrigerator units with numbered labels pointing to different interior compartmentsRCLK-F590GB, RCLK-F380G,
RCLK-F380GB, RCLK-C590GB

text_image
Diagram of two refrigerator doors with numbered labels pointing to each panelRCLK W600, RCLK F590S, RCLK F590, RCLK F380S.
RCLK-F380, RCLK-F170S, RCLK-C590, RCLK-C380G
RCLK C170

- Cerradura
- Panel de control
- Puerta
- Pies regulables