STN2000PTC - Heating STANLEY - Free user manual and instructions
Find the device manual for free STN2000PTC STANLEY in PDF.
| Product Type | Electric Fan Heater |
| Brand | Stanley |
| Model | STN2000PTC (equivalent ST-22-240-E) |
| Rated Power | 2.0 kW |
| Airflow | 158 m³/h |
| Recommended Heating Area | Up to 20 m³ / 7 m² |
| Voltage / Frequency | 220-240 V / 50 Hz |
| Heat Settings | 2 positions (medium and full power) + fan only |
| Thermostat | Mechanical adjustment knob |
| Overheat Protection | Yes, automatic shut-off with manual reset |
| Protection Rating | IP20 |
| Appliance Class | I (grounding required) |
| Weight | 1.7 kg |
| Dimensions (approx.) | 25 x 20 x 30 cm |
| Heating Element Material | Steel with protective coating |
| Protective Grille | Yes, front and rear |
| Carrying Handle | Yes, integrated |
| Adjustable Tilt | Yes, via side knobs |
| Use | Indoor only, well-insulated spaces |
| Maintenance | Clean with a soft cloth and mild detergent, do not immerse |
| Warranty | 2 years (according to local legislation) |
| Country of Manufacture | China (according to manufacturer information) |
Frequently Asked Questions - STN2000PTC STANLEY
1. The thermostat is set too low: turn it towards + to increase the set temperature.
2. The ambient temperature has already been reached: the thermostat cuts the heating element, this is normal.
3. The overheat protection has triggered: turn off the device, unplug it, check that the air inlets/outlets are not blocked, wait 10 minutes then plug back in.
User questions about STN2000PTC STANLEY
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Heating in PDF format for free! Find your manual STN2000PTC - STANLEY and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. STN2000PTC by STANLEY.
USER MANUAL STN2000PTC STANLEY
natural_image
Black STANLEY industrial power supply unit with yellow cord and mesh grille (no visible text or symbols on device body)Elektrische ventilatorkachel
text_image
Prohibition sign with crossed-out document and shield icon, indicating no document or shield usetext_image
Technical diagram of a portable air purifier with numbered parts labeled 1 through 8Pinnacle Climate Technologies, Inc. Sauk Rapids, MN 56379 VS
EC REP
Obelis S.A. Geregistreerd adres: Bd. Général Wahis, 53 1030 Brussels, Belgium
STANLEY®
ST-22-240-E / ST-23-240-E / ST-25-400-E

natural_image
Black STANLEY industrial power heater with yellow cord and mesh grille (no visible text or symbols)text_image
Prohibition sign with crossed-out document and magnifying glass symbol, commonly used to indicate file or document restrictions.text_image
Technical diagram of a portable air conditioner with numbered parts labeled 1 through 8
Pinnacle Climate Technologies, Inc. Sauk Rapids, MN 56379 USA
EC REP
Obelis S.A. Domiciliation : Bd. Général Wahis, 53 1030 Brussels, Belgium
STANLEY®
ST-22-240-E / ST-23-240-E / ST-25-400-E

natural_image
Black STANLEY industrial power supply unit with yellow cord and mesh grille (no visible text or symbols on device body)text_image
Prohibition sign with crossed-out document and shield icon, indicating no document or shield usetext_image
Technical diagram of a portable air purifier with numbered parts labeled 1 through 8Pinnacle Climate Technologies, Inc.
Sauk Rapids, MN 56379 USA
EC REP
Obelis S.A.
1030 Brussels, Belgium
STANLEY®
ST-22-240-E / ST-23-240-E / ST-25-400-E

natural_image
Black STANLEY industrial power supply unit with yellow cord and mesh grille (no visible text or symbols on device body)text_image
Prohibition sign with crossed-out document and shield icon, indicating no document or shield usetext_image
Technical diagram of a portable air conditioner with numbered parts labeled 1 through 8natural_image
Black STANLEY industrial power supply unit with yellow handle and mesh grille (no visible text or symbols on device body)text_image
Prohibition sign with a diagonal line crossing over a document icon, indicating no text or document.text_image
Technical diagram of a portable air purifier with numbered parts labeled 1 through 8ES
Pinnacle Climate Technologies, Inc. Sauk Rapids, MN 56379 USA
EC REP
Obelis S.A. Registered Address: Bd. Général Wahis, 53 1030 Brussels, Belgium
STANLEY®
ST-22-240-E / ST-23-240-E / ST-25-400-E

natural_image
Black STANLEY industrial power supply device with yellow handle and mesh grille (no visible text or symbols on body)text_image
Prohibition sign with crossed-out document and shield icon, indicating no liability or exclusiontext_image
Technical diagram of a portable air conditioner with numbered parts labeled 1 through 8natural_image
Black STANLEY industrial power supply unit with yellow cord and mesh grille (no visible text or symbols on device body)Electric Fan Heater
This product is only suitable for well insulated spaces or occasional use.
CE

text_image
RoHS

NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
GB
PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE USING THE APPLIANCE.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
- CAUTION: Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The heater must not be located immediately below a socket-outlet.
- Do not use this heater in the immediate surroundings of a bath, a shower or a swimming pool.
- Do not use the appliance for other than its intended use. For domestic indoor use only.
- Place the appliance on a flat, stable, heat-resistant surface. Operating the product in any other position could cause a hazard.
- There may be trace of odour during the first few minutes of initial use. This is normal and will quickly disappear.
- Do not attempt to repair, disassemble or modify the appliance. There are no user-serviceable parts inside.
- CAUTION – if using an extension lead please ensure you do not exceed the maximum rated running wattage/load of the extension lead.

Read the instruction manual: When this symbol is marked on a product, it means that the instruction manual must be read.
Do not use the appliance for other than its intended use. For domestic indoor use only.

text_image
Prohibition sign with crossed-out document and shield icon, indicating no document or shield useWARNING: In order to avoid overheating, do not cover the heater.
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO A POWER SOURCE
ST-22-240-E / ST-23-240-E / ST-25-400-E

text_image
Technical diagram of a portable air conditioner with numbered parts labeled 1 through 8GB
- Front Guard
- Fan
- Heat Coil
- Power Light
- Function Selector
- Handle
- Thermostat
- Adjustment Knob (x2)
NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
GB
SPECIFICATIONS
Specifications subject to change without notice
| ST-22-240-E ST-23-240-E ST-25 | 400-E | ||
| RATED POWER INPUT (kW) 2.0 3.0 5.0 | |||
| AIR FLOW ( m^3/h ) 158 217 300 | |||
| HEATING AREA ( m^3/m^2 ) 20/7 40/12 60/15 | |||
| RATED VOLTAGE/FREQUENCY (V/Hz) | 220-240/50 220-240/50 | 400/50 | |
| HEAT SETTINGS 2 | 2 | 2 | |
| WEIGHT (kg) | 1.7 | 2.9 | 4.2 |
| APPLIANCE CLASS | 1 | 1 | 1 |
| INGRESS PROTECTION RATING (IP) | IP20 | IP20 | IP20 |
| FUNCTIONS / SETTINGS | |||
| Unit is Off | ○ | ○ | ○ |
| Fan Runs - No Heating | ◎ | ◎ | ◎ |
| Fan Runs - Half Power Heating | ◎ | ◎ | ◎ |
| Fan Runs - Full Power Heating | ◎ | ◎ | ◎ |
| NOTE: The fan will run continuously while the heater is operating. | |||
NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
Safety Information
IMPORTANT: Read and understand all of the safety information and instructions in this manual before operating your heater.
DANGER
RISK OF EXPLOSION! Do Not operate this heater where there are harmful, explosive or flammable gasses, fumes or hazardous substances.
WARNING
RISK OF FIRE! Do Not operate this heater near combustible materials.
WARNING
ELECTRIC SHOCK HAZARD! Do not use this heater in the immediate surroundings of a bath, a shower, or a swimming pool.
WARNING
BURN HAZARD! Do Not touch the front of heater while it is operating. This heater is hot while operating.
WARNING
Risk Of injury! Do Not move heater while it is operating.
WARNING
RISK OF ELECTRIC SHOCK! DISCONNECT FROM POWER BEFORE MAINTENANCE.
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO A POWER SOURCE
Children should be supervised so they do not play with the appliance.
ALWAYS use only the electrical power (voltage and frequency) specified on the model plate of the heater.
ALWAYS use an extension cord properly rated for this appliance.
ALWAYS ensure that all cords are protected against short circuit and overload.
ALWAYS keep power cord away from hot air outlet.
ALWAYS disconnect heater from power source when not in use.
NEVER place the heater on a small, uneven or unstable surface that may cause the heater to fall.
NEVER connect other appliances to the same electrical outlet as the fan heater.
NEVER operate heater with heater guards removed.
NEVER block hot air outlet while heater is operating.
NEVER cover or obstruct heater.
NEVER use ducting with heater.
NEVER pull or carry heater by the power cord.
NEVER use heater with an external switching device: such as a timer.
If heater is damaged, do not use it. The heater must be serviced by a qualified person or service agent.
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO A POWER SOURCE
Operation
- Position the fan heater so that it stands upright on a firm, level surface and at a safe distance from wet environments and flammable objects.
- Connect the fan heater to the proper electrical power.
- Set the thermostat dial to “+”.
- The fan heater will switch on when the function selector dial is set to one of the power settings.
- Once the room reaches the desired temperature, turn the thermostat dial back until heating element turns off.
- Before you switch off the heater, please turn the thermostat to “-” and turn the switch to the fan position. Let the appliance cool down for two minutes, and only then turn off the heater and pull out the plug from the power supply.
Automatic Overheat Safety Control
- This heater is equipped with safety internal heat limiting thermostat and overheat protection circuit. When a potential overheat temperature is reached, the system will automatically shut the heater off.
Thermostat Instructions
- At first, set the thermostat to “+” and let the heater operate with full power input. When the room temperature reaches the required value, turn the thermostat to the left until it switches off.
- The thermostat will then switch on and off automatically to control the room temperature according to the preset value and keep the room temperature constant.
- When using the heater for the first time, you may notice a slight emission of smoke. This is quite normal and it stops after a short time. The heating element is made of steel and was coated with a layer of protective oil during production. The smoke is caused by the leftover oil as it is heated.
Cleaning and Maintenance
- Before cleaning the appliance, disconnect it from the outlet and let it cool down.
- The enclosure is easy to get dirty. Wipe it often with a soft sponge. For very dirty parts, wipe with a sponge dipped in <50^ C water and mild detergent, then dry the heater enclosure with a clean cloth. Be careful not to let the water enter the inside of the appliance
- In order to protect the enclosure, don't splash water onto the heater, and never use a solvent like gasoline, isoamyl acetate, toluene, etc. to clean the heater.
- When you store the heater, let it cool down first and, keep it dry. Then cover it with a plastic bag, put it in the packing box and store it in a dry, ventilated place.
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO A POWER SOURCE
Plug Replacement
WARNING
RISK OF ELECTRIC SHOCK! DISCONNECT FROM POWER BEFORE MAINTENANCE.
NOTE: This section only applies to heaters sold or used in Great Britain.
This appliance is supplied with a BS1363 3 pin plug fitted with a fuse. Should the fuse require replacement, it must be replaced with a fuse with the proper amp rating. (see Technical Specifications page 5) and approved to BS1362.
In the event the mains plug has to be removed/ replaced for any reason, please note:
IMPORTANT: The wires in the mains lead are colored in accordance with the following code:
Blue – Neutral Brown – Live
Green/Yellow – Earth
As the colors of the wires in the mains lead of this appliance may not correspond with the colored markings identifying the terminals in your plug, proceed as follows:
The blue wire must be connected to the terminal marked with an N or colored black. The brown wire must be connected to the terminal marked with an L or colored red. The green/ yellow wire must
be connected to the earthing terminal which is marked with an E or with the earth symbol.
NOTE: If a moulded plug is fitted and has to be removed take great care in disposing of the plug and severed cable, it must be destroyed to prevent engaging into a socket.
WARNING
Never connect live or neutral wires to the earth terminal of the plug.
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO A POWER SOURCE
Plug Replacement Wiring Diagram

text_image
GREEN / YELLOW Earth BROWN Live BLUE Neutral FUSE 13 Amps CORD CLAMP E L NFigure 3
NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
Troubleshooting
| Problem Cause Solution | ||
| The heater does not run, even when it is plugged in and the thermostat is switched on | 1. The plug is loose, bad connection. | 1. Pull out the plug, check the connection of the plug and socket. Then connect again. |
| The heating element is glowing | 1. The input voltage is too high or too low2. The air inlet grill is blocked. | 1. Use correct power supply stated on the rating label.2. Keep the heater away from items such as; plastic bags, paper, and other items that can cover the air inlet. |
| The appliance didn't heat up, only the ventilator worked. | 1. The switch was not on a heat setting2. Desired room temperature reached3. The self-resetting cut-out initiated | 1. Turn the switch to the desired heat setting2. Thermostat will shut off once desired room temperature is reached.Heater is operating correctly.3. Turn the heater off and inspect the blockage of inlet or outlet. Disconnect the plug and wait at least 10 minutes for the protection system to reset before attempting to restart the heater. |
| Abnormal noise. | 1. The appliance is not standing upright. | 1. Place the heater on a level surface. |
NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
Information requirements for electric local space heaters
| Model identifier(s): PT-02-240-EU; ST-02-240-E; ST-52-241-E; ST-22-240-E | ||||||
| Item | Symbol | Value | Unit | Item | Unit | |
| Heat output | Type of heat input, for electric storage local space heaters only (select one) | |||||
| Nominal heat output | P_nom | 2.0 | kW | manual heat charge control, with integrated thermostat | NO | |
| Minimum heat output (indicative) | P_min | 1.0 | kW | manual heat charge control with room and/or outdoor temperature feedback | NO | |
| Maximum continuous heat output | P_max,c | 2.0 | kW | fan assisted heat output | NO | |
| Auxiliary electricity consumption | Type of heat output/room temperature control (select one) | |||||
| At nominal heat output | el_max | N/A | kW | single stage heat output and no room temperature control | NO | |
| At minimum heat output | el_min | N/A | kW | two or more manual stages, no room temperature control | NO | |
| In standby mode | ek_B | N/A | kW | with mechanic thermostat room temperature control | YES | |
| with electronic room temperature control | NO | |||||
| electronic room temperature control plus day timer | NO | |||||
| electronic room temperature control plus week timer | NO | |||||
| Other control options (multiple selections possible) | ||||||
| room temperature control, with presence detection | NO | |||||
| room temperature control, with open window detection | NO | |||||
| with distance control option | NO | |||||
| with adaptive start control | NO | |||||
| with working time limitation | NO | |||||
| with black bulb sensor | NO | |||||
| Contact details | Name and address of the manufacturer or its authorised representative Obelis S.A Bd. General Wahis, 53 1030 Brussels, Belgium | |||||
NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
Information requirements for electric local space heaters
| Model identifier(s): PT-03-240-EU; ST-03-240-E; ST-53-241-E; ST-23-240-E | ||||||
| Item | Symbol | Value | Unit | Item | Unit | |
| Heat output | Type of heat input, for electric storage local space heaters only (select one) | |||||
| Nominal heat output | P_nom | 3.0 | kW | manual heat charge control, with integrated thermostat | NO | |
| Minimum heat output (indicative) | P_min | 1.5 | kW | manual heat charge control with room and/or outdoor temperature feedback | NO | |
| Maximum continuous heat output | P_max,c | 3.0 | kW | fan assisted heat output | NO | |
| Auxiliary electricity consumption | Type of heat output/room temperature control (select one) | |||||
| At nominal heat output | el_max | N/A | kW | single stage heat output and no room temperature control | NO | |
| At minimum heat output | el_min | N/A | kW | two or more manual stages, no room temperature control | NO | |
| In standby mode | ekB | N/A | kW | with mechanic thermostat room temperature control | NO | |
| with electronic room temperature control | NO | |||||
| electronic room temperature control plus day timer | NO | |||||
| electronic room temperature control plus week timer | NO | |||||
| Other control options (multiple selections possible) | ||||||
| room temperature control, with presence detection | NO | |||||
| room temperature control, with open window detection | NO | |||||
| with distance control option | NO | |||||
| with adaptive start control | NO | |||||
| with working time limitation | NO | |||||
| with black bulb sensor | NO | |||||
| Contact details | Name and address of the manufacturer or its authorised representative Obelis S.A Bd. General Wahis, 53 1030 Brussels, Belgium | |||||
NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
Information requirements for electric local space heaters
| Model identifier(s): PT-05-400-EU; ST-05-400-E; ST-55-401-E; ST-305-401-E; ST-25-400-E | ||||||
| Item | Symbol | Value | Unit | Item | Unit | |
| Heat output | Type of heat input, for electric storage local space heaters only (select one) | |||||
| Nominal heat output | P_nom | 5.0 | kW | manual heat charge control, with integrated thermostat | NO | |
| Minimum heat output (indicative) | P_min | 2.5 | kW | manual heat charge control with room and/or outdoor temperature feedback | NO | |
| Maximum continuous heat output | P_max,c | 5.0 | kW | fan assisted heat output | NO | |
| Auxiliary electricity consumption | Type of heat output/room temperature control (select one) | |||||
| At nominal heat output | el_max | N/A | kW | single stage heat output and no room temperature control | NO | |
| At minimum heat output | el_min | N/A | kW | two or more manual stages, no room temperature control | NO | |
| In standby mode | el_SB | N/A | kW | with mechanic thermostat room temperature control | YES | |
| with electronic room temperature control | NO | |||||
| electronic room temperature control plus day timer | NO | |||||
| electronic room temperature control plus week timer | NO | |||||
| Other control options (multiple selections possible) | ||||||
| room temperature control, with presence detection | NO | |||||
| room temperature control, with open window detection | NO | |||||
| with distance control option | NO | |||||
| with adaptive start control | NO | |||||
| with working time limitation | NO | |||||
| with black bulb sensor | NO | |||||
| Contact details | Name and address of the manufacturer or its authorised representative Obelis S.A Bd. General Wahis, 53 1030 Brussels, Belgium | |||||
NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
STANLEY®
SERVICE
| Belgique et Luxemburg | E. Walschaertstraat 14 | www.stanleyworks.be | United Kingdom | 210 Bath Road; Slough, Berks SL1 3YD | www.stanleytools.co.uk |
| België en Luxembourg | 2800 Mechelen | Enduser.be@SBDinc.com | Tel: +44 (0)1753 511234 | ||
| Belgium | BE-NL=+32 15 47 37 65 | Fax: +44 (0)1753 512365 | |||
| BE-FR=+32 15 47 37 64 | |||||
| BE Fax: +32 15 47 37 100 | |||||
| Danmark Roskildevej 22 | 2620 Albertslund | www.stanleyworks.dk | Hungary Rotel Kft. | 1163 Budapest,Thököly út 17. | www.stanleyworks.hu |
| kundeservice.dk@sbdinc.com | service@rotelkft.hu | ||||
| Fax: 70224910 | Tel: +36 1 404-0014 | ||||
| Fax: +36 1 403-2260 | |||||
| Deutschland Richard Klinger Str. 11 | 65510 Idstein | www.stanleyworks.de | Czech Republic | BAND SERVIS CZ s.r.o. | www.stanleyworks.cz |
| info@sbdinc.de | K Pasekam 4440 | http://www.bandservis.cz | |||
| Tel: 06126-21-1 | 760 01 Zlin, Czech Republic | Tel.: +420 577 008 550 | |||
| Fax: 06126-21-2770 | Fax: +420 577 008 559 | ||||
| Ελλός Ημερος Τόπος 2 - Χάνι Αδάμ Ασπρόπυργος | -19300 -Αττική -Αττικής | www.stanley.gr | Slovakia | BAND SERVIS s.r.o. | www.bandservis.sk |
| Greece.Service@sbdinc.com | Paulinska 22 | Tel.: +421 335 511 063 | |||
| Tηλ: +30 210 8985208 | 917 01 Trnava, Slovakia | Fax: +421 335 512 624 | |||
| Φαξ: +30 210 5597598 | |||||
| España Parque de Negocios "Mas Blau" | Edificio Muntadas, c/Bergadá, 1, Of. A6 | www.stanleyworks.es | Poland Erpatech | ul. Bakaliowa 26 | www.stanleyworks.pl |
| respuesta.postventa@sbdinc.com | 05-080 Mościska | Tel.: +48 22 431 05 00 | |||
| 08820 El Prat de Llobregat (Barcelona) | Tel: 934 797 400 | Slovenia G-M&M d.o.o. | www.g-mm.si | ||
| Fax: 934 797 419 | Brvace 11 | gmm@g-mm.si | |||
| 1290 Grosuplje Slovenija | T: +386 01 78 66 500 | ||||
| France 5, allée des hêtres | BP 30084, 69579 Limonest Cedex | www.stanleyoutillage.fr | Cyprus | IOANNOU J. | ioannou.ioannis@cytanet.com.cy |
| scufr@sbdinc.com | 4A Ath.Diakou street | Tel: +357 22344302 | |||
| Tel: 04 72 20 39 77 | 1046- Nicosia -Cyprus | Fax: +357 22348098 | |||
| Fax: 04 72 20 39 00 | |||||
| Schweiz | In der Luberzen 42 | www.stanleyworks.ch | Bosnia-Herzegovina | G-M&M d.o.o. | www.g-mm.si |
| Suisse | 8902 Urdorf | verkaufch.sbd@sbdinc.com | Brvace 11 | gmm@g-mm.si | |
| Svizzera | Tel: 044 - 755 60 70 | 1290 Grosuplje | T: +386 01 78 66 500 | ||
| Fax: 044 - 730 70 67 | Slovenija | F: +386 01 78 63 023 | |||
| Ireland 210 Bath Road; Slough, Berks SL1 3YD UK www.stanleytools.co.uk | Tel: +44 (0)1753 511234 | Bulgaria | TASHEV-GALVING LTD | www.tashev-galving.com | |
| Fax: +44 (0)1753 512365 | 68 KLIMENT OHRIDSKI BLVD. | T: +359 2 700 45 45 4 | |||
| 1756 Sofia, Bulgaria | F: +359 (2) 439 21 12 | ||||
| Italia Energypark-Building 03 sud, Via Energy Park | 6 20871 Vimercate (MB) | www.stanley.it | Croatia G-M&M d.o.o. | Brvace 11 | www.g-mm.si |
| Tel: 039-9590-200 | 1290 Grosuplje | gmm@g-mm.si | |||
| Fax: 039-9590-313 | Slovenija | T: +386 01 78 66 500 | |||
| Nederlands Stanley Black & Decker Netherlands B.V. | Postbus 83 | www.stanleyworks.nl | F: +386 01 78 63 023 | ||
| 6120 AD Born | Enduser.NL@sBDinc.com | ||||
| Tel: +31 164 28 30 63 | Mustame tee 44, | www.tallmac.ee/est | |||
| NL Fax: +31 164 28 32 00 | EE-10621 Tallinn | T: +372 6562999 | |||
| Norge Postboks 4613, Nydalen | 0405 Oslo | www.stanleyworks.no | Latvia LIC GOTUS SIA | www.licgotus.lv | |
| kundeservice.no@sbdinc.com | Ulbrokas Str. | T: +371 67556949 | |||
| Fax: 45 25 08 00 | LT - 1021 Riga | F: +371 67555140 | |||
| Österreich Oberlaerstrasse 248 | A-1230 Wien | www.stanleyworks.de | Lithuania | UAB ELREMTA OU | info@elremta.lt |
| service.austria@sbdinc.com | Neries kr. 16E | T: +370-685-29035 | |||
| Tel: 01 - 66116 - 0 | LT - 48402 Kaunas | F: +370-37-406540 | |||
| Fax: 01 - 66116 - 14 | |||||
| Portugal Quinta da Fonte - Edificio Q55 D. Diniz | Rua dos Malhões, 2 e 2A - Piso 2 Esquerdo | www.stanleyworks.pt | Malta Energypark-Building 03 sud, Via Energy Park | 6 20871 Vimercate (MB) | www.stanley.it |
| 2770 - 071 Paço de Arcos | resposta.posvenda@sbdinc.com | Tel: 039-9590-200 | |||
| Tel: 214 66 75 00 | Fax: 039-9590-313 | ||||
| Fax: 214 66 75 75 | |||||
| Suomi PL 47 | 00521 Helsinki | www.stanleyworks.fi | Romania | Stanley Black & Decker | www.stanleyworks.ro |
| customerservice.fi@sbdinc.com | Phoenicia Business Center | T: +4021.320.61.04/05 | |||
| Puh: 010 400 4333 | Strada Turturelelor, nr 11A, Etaj 6, Modul 15, Sector 3 Bucuresti | F: +4037.225.36.84 | |||
| Sverige Box 94 | 431 22 Mölndal | www.stanleyworks.se | Serbia | G-M&M d.o.o. | www.g-mm.si |
| kundservice.se@sbdinc.com | Brvace 11 | gmm@g-mm.si | |||
| Fax: 31 68 60 08 | 1290 Grosuplje | T: +386 01 78 66 500 | |||
| Slovenija | F: +386 01 78 63 023 | ||||
STANLEY®
Pinnacle Climate Technologies, Inc. Sauk Rapids, MN 56379 USA
EC REP