USER MANUAL SLE 320 D5 SILVERCREST

SLE 320 D5 Introduction Information about this short manual This document is a shortened print version of the complete operating instructions. Scanning the QR code will take you directly to the Lidl Service page (www.lidl-service.com), where you can view and download the full version of the operating instructions by entering the article number (IAN) 379890_2104. WARNING! Observe the information in the complete operating instructions and the safety instructions to avoid personal injury and damage to property. The short manual is an integral part of this product. Before using the product, please familiarise yourself with all operating and safety instructions. Keep the short manual in a safe place and hand over all documents when passing the product on to any future owner/user. Proper use The appliance is exclusively intended to dehumidify living spaces, basements or storage areas with an ambient temperature of 5°C to 32°C. The appliance may only be used indoors. The appliance is intended solely for personal and not commercial use. Usage other than as described above is not permissible and may result in injury and/or damage to the appliance. The manufacturer accepts no liability for damage caused by improper application or usage. The risk is borne solely by the user.GB

 3 ■ SLE 320 D5 Warnings and warning symbols used The following warnings are used in this short manual: DANGER A warning notice at this hazard level indicates an imminently hazardous situation. Failure to avoid this hazardous situation could result in serious injuries or even death. ► Follow the instructions on this warning label to avoid the risk of death or serious injury. WARNING A warning at this hazard level indicates a potentially hazardous situation. Failure to avoid this hazardous situation could result in injury. ► Follow the instructions in this warning notice to prevent injuries. CAUTION A warning at this hazard level indicates a risk of property damage. Failure to avoid this situation could result in property damage. ► Follow the instructions in this warning notice to prevent property damage. NOTE ► A note provides additional information that will assist you in using the appliance. The following warning symbols are used on the appliance: Symbol Meaning Caution! Risk of fire! Observe operating instructions Instruction manual, operating instructions Service indicator, refer to the operating instructions■ 4 

SLE 320 D5 Safety This section contains important safety instructions for using the appliance. Im- proper use may result in personal injury and property damage. Risk of electrocution DANGER Risk of fatal injury from electrocution! Contact with live cables or components can result in a fatal injury! Please observe the following safety guidelines to prevent electrical hazards. ► Do not use the appliance if the power cable or the plug is damaged. ► There is a risk of electrocution if live connections are touched and the electrical and mechanical structure is changed. Risk of electrocution due to moisture DANGER ► Do not place the appliance in water, in water pooling areas or puddles. ► Never operate the appliance near a bath tub, a shower, a filled wash basin or similar structures. ► Do not immerse appliance, the cabling or the mains plug in water or other fluids. ► Protect the appliance from water droplets or spray. ► In the event that liquid enters the appliance (apart from in the water tank), disconnect the mains plug immediately. Ar- range to have the appliance checked before using it again. ► Do not handle the appliance with damp hands. ► If the appliance falls into water, disconnect the mains plug immediately. Do not attempt to remove the appli- ance before you have done so.GB

 5 ■ SLE 320 D5 Danger of explosion/fire DANGER ► Do not use the appliance in a potentially explosive environment containing combustible liquids, gases or dusts. Electrical appliances generate sparks that can ignite the dust or fumes. ► The appliance contains extremely flammable gas under pressure that may explode if heated. ► Keep the appliance away from heat, hot surfaces, sparks, naked flames and other sources of ignition. Do not smoke. RISK OF FIRE! ► Do not use any items other than those permitted by the manufacturer to speed up the defrosting process. ► The appliance may only be stored in rooms without permanent sources of ignition (e.g. open flames, a switched-on gas appliance or an electric heater). ► Do not drill or burn. ► Remember that refrigerants are odourless.■ 6 

SLE 320 D5 Risk of disease DANGER ► The collected water is not suitable for drinking or watering plants. There are potential health hazards.

WARNING: MATERIAL DAMAGE

► Do not use the appliance in swimming pools, wash rooms or similar facilities. ► The appliance is not suitable for drying lagging. If insu- lation or lagging materials are damp following a pipe burst, consult an expert. ► Never expose the appliance to temperatures of 0°C or lower. Residual water in the lines could freeze and damage the system. ► Do not use the appliance in a dusty or chlorinated environment.GB

 7 ■ SLE 320 D5 Basic safety instructions To ensure safe operation of the appliance, follow the safety guidelines set out below: ■ Check the appliance for visible external damage before use. Do not use an appliance that has been damaged or dropped. ■ To avoid potential risks, damaged mains cables should be replaced by the manufacturer, its customer service depart- ment or a similarly qualified person. ■ Do not operate the appliance outdoors. ■ During operation, always keep windows and doors closed so that the appliance can work effectively. ■ Do not operate the appliance in the proximity of highly inflammable gases or materials, near naked flames or in areas prone to oil and water splashing. ■ This appliance may be used by children aged 8 years and above and by persons with limited physical, sensory or mental capabilities or lack of experience and knowledge, provided that they are under supervision or have been told how to use the appliance safely and are aware of the poten- tial risks. Do not allow children to use the appliance as a toy. Cleaning and user maintenance tasks may not be carried out by children unless under supervision. ■ All repairs must be carried out by authorised specialist companies or by the Customer Service department. Improper repairs can pose significant risks to the user. It will also invalidate any warranty claims. ■ Do not expose the appliance to rain. Protect the appliance against moisture and the ingress of fluids and objects into the casing. Never immerse the appliance in water and do not place objects containing fluids (e.g. vases) on the appliance. The appliance could be irreparably damaged! ■ Do not place heavy objects on the appliance.■ 8 

SLE 320 D5 ■ Do not cover the appliance (e.g. with newspapers, cushions or blankets). ■ Do not insert any objects into the ventilation slits. ■ Avoid direct sunlight. ■ Do not place any naked flames, e.g. burning candles, on or directly next to the appliance. ■ In the event of malfunctions, and in bad weather, disconnect the plug from the mains power socket. ■ Ensure that the air inlet and air outlet opening remain free of soiling during operation. Never cover the appliance! ■ Always place the appliance on a solid, flat surface so that it cannot tip over. ■ Do not permanently install the appliance. Position the appli- ance so that its side panels have a clearance of at least 20 cm from walls or other objects and ensure a clearance of at least 50 cm from the front, rear and top panels of the appli- ance in order to ensure good air circulation. Take care not to obstruct the air inlet and outlet opening. ■ The appliance may only be operated in rooms with an ambi- ent temperature of 5°C to 32°C. ■ Use the appliance only in rooms up to 32 m². ■ The appliance must be installed, operated and stored in a room with a floor area greater than 4 m

■ If the appliance is operated in unventilated areas, these must be designed in such a way that the refrigerant cannot accumulate anywhere in the event of refrigerant leakage. Otherwise, a combustible mixture may be formed. ■ The appliance may only be stored in rooms without perma- nent sources of ignition (e.g. open flames, a switched-on gas appliance or an electric heater). ■ The appliance must be stored in a way that does not dam- age it.GB

 9 ■ SLE 320 D5 ■ Clean the air filter before it becomes heavily soiled. ■ While draining via a hose, ensure that it does not become blocked and that the open end of the hose is positioned at a lower level than the outlet aperture. The end of the hose must be positioned above a drain. ■ Operate the appliance only together with the water tank or with the hose installed. ■ Connect the safety plug only to a properly installed, easily accessible plug socket with protected contacts, the voltage of which corresponds to the specifications on the rating plate. The plug socket must remain easily accessible even after connection. ■ Before cleaning, always disconnect the mains plug from the mains power socket. ■ Always transport, operate and store the appliance upright! The water tank must be emptied before transport. Operation Package contents and transport inspection The appliance is supplied with the following components as standard: ▯ Dehumidifier ▯ Hose ▯ EU garden hose adapter ▯ This short manual NOTE ► Check the package for completeness and signs of visible damage. ► If the delivery is incomplete or damage has occurred as a result of defec- tive packaging or during transport, contact the Service hotline (see section Service). ♦ Remove all packaging materials and all carriage braces from the appliance. ♦ Remove the film from the control panel.■ 10 

k Hose l EU garden hose adapterGB

 11 ■ SLE 320 D5 Before initial use ♦ Place the appliance on a flat, dry and solid surface. ♦ Allow the appliance to remain in the usage position for approx. 30 minutes so that the coolant can settle. ♦ Check that the water tank 4 is correctly inserted. ♦ Insert the plug into a mains power socket. The OPERATION LED o flashes. Electrical connection CAUTION ► Before connecting the appliance, compare the specifications for the required input voltage on the rating plate with the intended voltage source for operation. This data must agree so that the appliance is not damaged. ► The power cable must always be easily accessible, so that the appliance can be quickly removed from the mains in the event of an emergency. ► Check whether the power cable is undamaged and that it is not routed over hot surfaces and/or sharp edges, otherwise it will become damaged. ► Ensure that the power cable is not taut or kinked. Guidelines for operation ■ If the air in your living spaces is constantly excessively humid, the cause should be identified and addressed. (Sustained - year-round - dehumidifying is generally not a good idea.) ■ The optimal ambient temperature for dehumidifying the air is 5°C to 32°C. Using a dehumidifier at temperatures below 5°C is redundant, as there is little humidity in the air. ■ During operation, room temperature can increase by between 1°C and 4°C, depending on the size of the room. This is normal. Automatic defrosting To ensure that the appliance does not ice up during sustained operation, it defrosts automatically. The defrosting function is activated automatically and cannot be switched on manually. The appliance cannot be switched off during defrosting. During defrosting, the AUTO DE-ICING LED j lights up. The lower the ambient temperature at which the appliance is operated, the earlier or more often the automatic defrosting is activated. Once the defrosting process is complete, the appliance resumes operation in the previous selected settings.■ 12 

SLE 320 D5 Handling and use This section provides you with important information on handling and using the appliance. Switching the appliance on/off ♦ Press the STAND-BY button i to turn on the appliance. You will hear a beep, and the OPERATION LED o lights up continu- ously. ♦ Press the STAND-BY button i to turn off the appliance. You will hear a beep, and the OPERATION LED o starts flashing. NOTE ► The appliance always starts up with the last-selected setting. ► If the appliance shuts down due to a power failure, it will automatically restart with the last–selected setting when power is restored. ♦ If a timer has been programmed, the appliance switches off permanently after the specified time has elapsed (1–24 hours). ♦ If the relative humidity value has been set in the TARGET HUMIDITY program, the appliance switches off as soon as the value is reached. If the value is exceeded, the appliance switches back on again. ♦ When the water tank 4 is full or removed, dehumidification stops. The fan continues to run for approx. 3 minutes and then switches off. If the water tank 4 has been removed or is not correctly inserted, the TANK FULL LED p lights up. If switched on, the appliance will also beep for approx. 20 seconds. NOTE ► The water tank 4 must be completely inserted into the appliance, other- wise the condensation water cannot be properly collected. Air outlet valve On the top of the appliance there is an adjustable flap 6 on the air outlet, which you must open during operation. You can adjust the flap 6 to different angles and thus determine the direction of the air flow. This can be helpful if you are using the appliance to dry washing, for example. In this way, you can direct the air flow towards the wet laundry.GB

 13 ■ SLE 320 D5 Operating status displays The different operating states are shown on the control panel 1 via LEDs and the display t. In addition, the appliance has a numeric LED panel 3 as well as an LED indicator light 2. It uses different colours to indicate the relative humidity range in the room. LED indicators LED lit Meaning TANK FULL p The water tank 4 is full or not inserted. TIMER r A switch-off time has been activated. DRY CLOTHES TARGET HUMIDITY FAN FUNCTION AUTOMATIC q Shows the selected programme. OPERATION o The appliance is switched on. AUTO DEFROST j Automatic defrosting is activated. Display indicator Display Meaning During operation, the current relative humidity value is permanently displayed in %. Hold the UP arrow z for approx. 3 seconds to display the current ambient temperature in °C. After approx. 5 seconds the display automatically changes back to the humidity value. LED indicator light Colour Meaning Red Relative humidity HIGH (> 70%) Green Relative humidity MID (≥ 50 to ≤ 70%) Yellow Relative humidity LOW (< 50%) NOTE ► Note that the values for the relative humidity have a tolerance of approx. ± 3 %, and switching on the appliance or dehumidification may be slightly delayed.■ 14 

SLE 320 D5 Selecting programmes The appliance has 4 distinct programmes. ♦ Press the MODE button w repeatedly to set the desired program. The programme LED q of the set programme lights up. DRY CLOTHES You can use this programme to dry damp laundry faster. Move the flap 6 on the air outlet so that the airflow is directed towards the garments to be dried. Changes regarding the desired air humidity and the fan level are not possible in this programme. TARGET HUMIDITY This programme offers you the option of setting the desired air humidity level that should be achieved yourself. ♦ Press the UP arrow z or DOWN arrow u to set the desired humidity in 5% steps between 30% and 80%. The set value flashes on the display t for approx. 5 seconds and then the current relative humidity value is shown again. As soon as the selected humidity is reached, the HUMIDITY REACHED LED a lights up. Additionally, you also have the option to select the setting if you want to make a setting below 30% relative humidity. This setting allows you to achieve a very low humidity as the dehumidification runs permanently. To achieve maximum dehumidification, the fan speed must be set high. To do this, press the FAN SPEED button e, until the LED h (high) lights up. NOTE ► The minimum humidity that can be achieved in mode is dependent on many factors, such as the room size or the ambient temperature, etc. Therefore, it is not possible to define a generally applicable minimum value.GB

 15 ■ SLE 320 D5 FAN FUNCTION No dehumidification takes place in this programme. The room air is drawn in through the air inlet, passes through the filter8 and is discharged back into the room via the air outlet. ♦ Press the FAN SPEED button e to select the desired fan level. The LEDs g (ype) and h (high) indicate which fan level is set. AUTOMATIC With this programme, the following functions are automatically activated or deactivated depending on the respective humidity in the room: Humidity Dehumidification Fan > 70% On Fan speed: High 55‒70% On Fan speed: Low < 55% Off Fan speed: Low Timer function The appliance is equipped with a timer function that can be used with any one of the 4 programmes. One of 24 switch-off times, ranging from 1 to 24 hours, can be selected. Once the set time has elapsed, the appliance switches off permanently. ♦ Press the TIMER button r during operation. The TIMER LED f lights up, and flashes on the display t. ♦ Press the UP arrow z or the DOWN arrow u to set a switch-off time from 1 to 24 hours. The selected switch-off time flashes on the dis- playt for approx. 5 seconds and then the current relative humidity value is displayed again. ♦ To end the timer prematurely, press the TIMERbuttonr twice. The TIMER LED f goes out and the display t shows the current relative humidity value.■ 16 

SLE 320 D5 Water tank The water tank 4 has a capacity of approx. 6.5 litres. The water level can be checked by means of the fill level indicator 0. The appliance can only be operated with the water tank 4 inserted. When the water tank4 is full, the TANK FULL LED p lights up. In addition, the appliance will also beep for approx. 20 seconds. The dehumidification stops; the fan continues to run for approx. 3 minutes and then switches itself off. ♦ Carefully pull the water tank 4 out of the appliance using the recessed grips on the side. Use the handle to transport the water tank 4 (see figure 1).

Fig. 1 ♦ Pour out the water through the opening in the lid (see figure 2) and replace the water tank 4 in the appliance. The appliance resumes operation with the previously selected programme. Fig. 2GB

 17 ■ SLE 320 D5 Hose drainage In very humid rooms, it often makes more sense to drain off the water directly via a hose rather than collect it in the water tank 4 . You can use the supplied hosek or the EU garden hose adapter l to set up a permanent drainage outlet. CAUTION ► When draining via the hose, the appliance runs continuously. When draining via the hose, make sure that it is not kinked and that it runs downwards along the entire length. Otherwise, the water may flow back into the appliance and damage it. ► Check the entire connection system regularly for leaks. ♦ Connect either the supplied hose k or the EU garden hose adapter l to the outlet opening 9 (see figures 3 + 4). ♦ When using the EU garden hose adapter l, screw a garden hose onto the EU garden hose adapter l (see figure 4). Fig. 3 Fig. 4 CAUTION ► Screw the EU garden hose adapter l hand-tight only. Do not use a wrench as this may damage the EU garden hose adapter l. NOTE ► Depending on the garden hose system you use, you may need an addition- al adapter. These are available from specialist stores. ♦ Set up the appliance so that the end of the hose is positioned over a drain. The open end of the hose must lie below the outlet opening 9 of the appli- ance (i.e. the hose must have a downwards gradient).■ 18 

SLE 320 D5 Protection against overheating The appliance has an overheating protection. It switches off automatically if there is a risk of overheating and switches back on once the appliance has fully cooled down. The appliance cannot be used during the cool-down phase. ♦ Check whether external conditions may have triggered the overheating protection (e.g. temperatures above 32°C or a closed air outlet flap 6). Disposal Never dispose of the appliance in your normal domestic waste. This product is subject to the provisions of the European WEEE (Waste Electrical and Electronic Equipment) Directive 2012/19/EU. Dispose of the appliance via an approved disposal company or your municipal waste facility. Please comply with all applicable regulations. Please contact your waste disposal facility if you are in any doubt. Your local community or municipal authorities can provide information on how to dispose of the product. The product is recyclable, subject to extended producer responsibility and is collected separately. Disposal of the refrigerant This appliance contains R290 (propane) as a refrigerant. The system is hermeti- cally sealed. The undamaged refrigerant must be disposed of professionally. Please contact your waste disposal facility if you are in any doubt. Disposal of the packaging The packaging materials have been selected for their environmental friendliness and ease of disposal, and are therefore recyclable. Dispose of packaging materi- als that are no longer needed in accordance with applicable local regulations. Dispose of the packaging in an environmentally friendly manner. Note the labelling on the packaging and separate the packaging material components for disposal if necessary. The packaging material is labelled with abbreviations (a) and numbers (b) with the following meanings: 1–7: plastics, 20–22: paper and cardboard, 80–98: composites.GB

 19 ■ SLE 320 D5 Appendix Technical data Input voltage 220–240 V ∼ (alternating current), 50 Hz Input power 320W (at 27°C/60% rh) Nominal current 1.7 A (at 27°C/60% rh) Max. output power 420W (at 32°C/90% rh) Max. nominal current 2.1 A (at 32°C/90% rh) Air flow rate 195m³/h Water tank approx. 6.5 l Intake pressure 1.2MPa Discharge pressure 2.5MPa Dehumidification performance/24h* 20l (at 30°C/80% rh) 10l (at 27°C/60% rh) Recommended room size approx. 32m

(at a ceiling height of 2.5m) Refrigerant R290 Fill level 0.06 kg Operating temperature 5°C to 32°C Dimensions approx. 57.8 x 34.0 x 23.8 cm Weight approx. 13 kg

  • The lower the ambient temperature and the colder the temperature outside becomes, the less moisture accumulates in the air and flows from outside into the room to be dehumidified. For this reason, dehumidification performance steadily decreases when temperatures drop and can come to a standstill. This does not mean that the appliance is defective. Notes on the EU Declaration of Conformity In terms of compliance with fundamental specifications and other relevant regulations, this appliance complies with the Low Voltage Directive 2014/35/EU, the Electromagnetic Compatibility Directive 2014/30/EU and the Ecodesign Directive 2009/125/EC. The complete EU Declaration of Conformity is available from the importer.■ 20