BEURER MG 1 R Sensitive+ - Massage device

MG 1 R Sensitive+ - Massage device BEURER - Free user manual and instructions

Find the device manual for free MG 1 R Sensitive+ BEURER in PDF.

📄 106 pages English EN 💬 AI Question
Notice BEURER MG 1 R Sensitive+ - page 14

Download the instructions for your Massage device in PDF format for free! Find your manual MG 1 R Sensitive+ - BEURER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MG 1 R Sensitive+ by BEURER.

USER MANUAL MG 1 R Sensitive+ BEURER

1. Warnings and safety notes ...................16

2. Included in delivery ............................... 17

6.1 Initial use/charging the battery ...............19

6.2 Selecting/changing the attachment .......20

6.3 Switching on the device/ selecting the

intensity level .........................................20

7. Cleaning and maintenance ..................21

8. What if there are problems? .................21

The device is only intended for domestic/pri- vate use, not for commercial use.

This device may be used by children over the age of 8 and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are super- vised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.

Children must not play with the device.

Cleaning and user maintenance must not be performed by children unless supervised.

If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed, the device must be disposed of.

Under no circumstances should you open or repair the device yourself. If you do so, it may no longer function correctly. Failure to comply will invalidate the guarantee.

Do not insert any objects into the opening in the device or into the moving parts. Ensure that the moving parts can move freely at all times.

Do not force or jam any part of your body, in particular your fingers, between the moving massage elements or their holders in the device.16

1. WARNINGS AND SAFETY

NOTES WARNING Do not use the device if you suer from a medical abnormality or injury in the area to be massaged (e.g. slipped disc, open wounds).

Do not use the device if you wear a pacemaker.

Do not use the device for massaging the area around the heart.

Do not use the device on swollen, burnt, inflamed or injured skin and body parts.

Do not use the device on cuts, capil- laries, varicose veins, acne, couperose, herpes or other skin diseases.

Do not use the device during pregnan- cy.

Do not use the device on your head or face (e.g. on the eyes), except for the jaw muscles, provided you do not have any dental implants or general dental treatments.

Do not use the device on the larynx, in the pubic area or other particularly sen- sitive body parts.

Do not use the device on the spine or directly on the bone.

Do not use the device while sleeping.

Do not use the device on animals.

Do not use the device after the con- sumption of medicines or alcohol (re- duced cognition!).

Do not use the device in a vehicle. You should consult your doctor before using the device, especially

if you suer from a severe illness,

if you suer from thrombosis,

if you are suering from pain, the cause of which is unknown. WARNING

Danger of suocation! Keep packaging material away from children.

Danger of suocation! Keep the attach- ments away from children.

Risk of electric shock! Make sure that the device does not come into contact with water or other liquids.

Risk of electric shock! Never pick up a device that has fallen into water.

Children must be supervised at all times whilst using the device.

There may be a risk of fire if the device is used improperly or these instructions for use are ignored.

Never leave the device unattended when it is in operation, particularly if there are children nearby.

Never operate the device underneath a cover, such as a blanket, pillow, etc.

Never use the device near petrol or oth- er highly flammable substances.

Only operate the device in dry indoor areas.

Never operate the device in the bath or a sauna. IMPORTANT

Before use, ensure that the device and the attachments show no visible dam- age. If you have any doubts, do not use the device and contact your retailer or the specified Customer Services ad- dress.

Never open the housing.

Keep the device away from pointed or sharp objects.

If the device has been dropped or has suered any other damage, it must no longer be used.17

Switch o the device after every use and before cleaning.

Never use the device for more than 15 minutes (risk of overheating). Allow the device to cool down for at least 15 min- utes before using it again.

Only use the device with the supplied accessories.

Protect the device and the attachments from knocks, dust, chemicals, drastic changes in temperature, electromag- netic fields and nearby sources of heat (ovens, heaters). WARNING Repairs

Never attempt to repair the device yourself!

Only specialist personnel may perform repairs on electrical devices. Under no circumstances should you open or repair the device yourself. If you do so, it may no longer function correct- ly. Improper repairs may put users in significant danger. For repairs, please contact Customer Services or an au- thorised retailer. Failure to comply will invalidate the guarantee. WARNING Notes on handling batteries

If fluid from a battery cell comes into contact with your skin or eyes, wash the aected areas with water and seek medical assistance.

Choking hazard! Small children could swallow and choke on batteries. There- fore, keep batteries out of the reach of small children!

If a battery has leaked, put on protec- tive gloves to dispose of the device.

Protect batteries from excessive heat.

Risk of explosion! Never throw batter- ies into a fire.

Do not disassemble, split or crush the batteries.

In order to achieve as long a battery service life as possible, fully charge the battery at least 2 times a year.

Always switch the device o in advance of charging.

Batteries must be charged correctly prior to use. The instructions from the manufacturer and the specifications in these instructions for use regarding correct charging must be observed at all times.

2. INCLUDED IN DELIVERY

Check that the exterior of the cardboard de- livery packaging is intact and make sure that all contents are present. Before use, ensure that the Deep Tissue Massager and the at- tachments show no visible damage.

1 copy of these instructions for use

WARNING Only use the Deep Tissue Massager with the attachments included in delivery. The Deep Tissue Massager and the attachments are not medical devices, but massage treat- ment devices. The Deep Tissue Massager is only suitable for personal use, not for med- ical or commercial purposes. The device may only be used for the purpose for which it is designed and in the manner specified in the instructions for use. Any form of improp- er use can be dangerous. The manufactur- er is not liable for damage resulting from improper or incorrect use. Do not use the Deep Tissue Massager if one or several of18 the listed warnings and safety notes applies to you. If you are unsure whether the Deep Tissue Massager is suitable for you, please consult your doctor.

4. SIGNS AND SYMBOLS

The following symbols are used on the de- vice, in these instructions for use, on the packaging and on the type plate for the device: DANGER Indicates an imminent danger. If it is not avoided, it will result in death or serious injury. WARNING Indicates a potentially impending danger. If it is not avoided, there is a risk of death or serious injury. CAUTION Indicates a potentially impending danger. If it is not avoided, slight or minor injuries may result. NOTICE Indicates a potentially harmful situation. If it is not avoided, the system or some- thing in its vicinity may be damaged. Read the instructions Product information Note on important information CE labelling This product meets the require- ments of the applicable Europe- an and national directives. For indoor use only. Manufacturer Do not use the Deep Tissue Massager on people with im- planted electrical devices (e.g. a pacemaker) Separate the packaging elements and dispose of them in accordance with local regulations. Do not dispose of batteries containing harmful substances with household waste Separate the product and pack- aging elements and dispose of them in accordance with local regulations. The products demonstrably meet the requirements of the Technical Regulations of the EAEU. Conformity assessed marking for the United Kingdom

Marking to identify the packag- ing material. A = material abbreviation, B = material number: 1–7 = plastics, 20–22 = paper and cardboard Disposal in accordance with the Waste Electrical and Elec- tronic Equipment EC Directive – WEEE Polarity of DC power con- nection19 Direct current The device is suitable for use with direct current only Importer symbol

The associated drawings are shown on page 3.

Attachment 4 dierent attachments are available

Attachment connection

Intensity indicator (3 LEDs) 3 LEDs, starting from left to right

Battery level indicator (1 LED) During operation: LED lights up white = battery level 25–100% LED flashes red = battery level 0–25% During charging: LED flashes white = battery charging LED lights up white = battery fully charged

Flat head Best suited for treating large areas on the entire body (e.g. the thigh).

Spiral head Best suited for treating deep muscle tissue and for targeted spot mas- sages (e.g. on the sole of the foot).

Air cushion head Best suited for sensitive parts of the body (e.g. the neck).

Curved head Best suited for areas of the body that are naturally rounded (e.g. arms, lower legs or thighs)

charging the battery The massage must feel pleasant at all times. Start the treatment at the lowest intensity level and then increase it according to your pref- erences if necessary. A slight hae- matoma may well occur – this is a positive therapeutic eect as the use of the device can selectively encourage your blood flow. In iso- lated cases, areas of redness may also occur on the skin. If you ex- perience excessive skin irritation, stop using the device and consult a doctor. Depending on the level of tension, a treatment time of ap- prox. 10 minutes is recommended for the desired area (neck, shoul- ders, back, arms, buttocks or legs). Before using the Deep Tissue Massager for the first time, charge it for a minimum of 1:30 hours. To do so, proceed as follows:

1. Remove all packaging material from the

Connect the sup- plied USB-C cable to the Deep Tis- sue Massager. The connection for the USB-C cable

is located on the un- derside of the handle.

3. Connect the USB-C cable to a USB-C

mains plug (not included in delivery). Insert the USB-C mains plug into a suitable socket. The battery level in- dicator

shows the current battery level. Battery level indicator

battery charging Battery level indicator

battery is fully charged

As soon as the battery level indicator

lights up white, remove the USB-C mains plug (not included in delivery) from the socket. The battery is now fully charged. The battery will last for approx. 3 hours of operation when fully charged. As soon as the battery level indicator

starts to flash red, you must recharge the Deep Tissue Massager; otherwise it will automatically switch o.

6.2 Selecting/changing the

attachment Select the appropriate attachment before starting the massage. To change an attach- ment, proceed as follows:

1. Pull the existing at-

tachment horizon- tally o the Deep Tissue Massager.

Slide your desired attachment firmly into the Deep Tissue Massager until you feel it click securely into place.

6.3 Switching on the device/

selecting the intensity level The Deep Tissue Massag- er comes with an automatic switch-o function. This means that the Deep Tissue Massag- er automatically switches o after a period of use of approx. 10minutes.

for 2 seconds. The battery level indi- cator

starts to light up. The device is now in standby mode.

to switch on the device. The left LED of the intensity indicator

starts to light up. The massage starts at intensity lev- el 1.

To switch between the intensity levels, briefly press the ON/OFF button

shows the cur- rent intensity level. Intensity level 1 (1700 rpm) → Intensity level 2 (2450 rpm) → Intensity level 3 (3200 rpm) → Standby.

You can switch o the device at any time during use by pressing and hold- ing the ON/OFF button

again at the third intensity level, the device switches o. The device is in standby mode. If the device stops during use, this may be due to excessive pressure. Make sure that you do not exert too much pressure on the Deep Tissue Massager when using it.21

Switch o the device each time before cleaning.

Do not clean the device in the dish- washer.

Clean the device only using a slightly damp cloth and a non-abrasive clean- ing product. For hygienic cleaning, clean the attachments

with water and a non-abrasive cleaning product.

Clean the device using only the meth- ods specified. Under no circumstances may liquid enter the device.

When using massage oils (recommend- ed for attachment

only), ensure that all residue is completely removed and cleaned.

Do not use the device or attachments again until all components are com- pletely dry. Care If you do not plan to use the Deep Tissue Massager for a long period of time, we recommend that you store it in the original packaging in a dry environment, ensuring it is not weighed down by additional items.

8. WHAT IF THERE ARE

PROBLEMS? Prob- lem The Deep Tissue Massager stops during use. Solu- tion Make sure that you do not exert too much pressure on the Deep Tissue Massager when using it. If you exert too much pressure, the device will stop briefly.

Battery disposal Empty, completely flat batteries must be disposed of in specially designated collec- tion boxes, at recycling points or at elec- tronics retailers. You are legally required to dispose of the batteries. The codes below are printed on batteries containing harmful substances: Pb = battery contains lead Cd = battery contains cadmium Hg = battery contains mercury Faulty or used batteries must be recycled in accordance with Directive 2006/66/EC and amendments thereto. Return the batteries and/or the device using the collection facil- ities provided. For environmental reasons, do not dispose of the device in household waste at the end of its service life. Dispose of the device at a suit- able local collection or recycling point in your country. Dispose of the de- vice in accordance with EC Directive Waste Electrical and Electronic Equipment (WEEE). If you have any questions, please contact the local authorities responsible for waste disposal.22 Subject to errors and changes

(without attach- ments) Weight Approx. 250 g (without attach- ments, without USB-C cable) Battery: Capacity Nominal voltage Type designation 1100 mAh

VEDLIKEHOLD Rengjøring ADVARSEL

Manual assistant
Powered by ChatGPT
Waiting for your message
Product information

Brand : BEURER

Model : MG 1 R Sensitive+

Category : Massage device