MAKITA UT1200 - Hand blender

UT1200 - Hand blender MAKITA - Free user manual and instructions

Find the device manual for free UT1200 MAKITA in PDF.

📄 48 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice MAKITA UT1200 - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Brand Makita
Model UT1200
Product type Immersion blender / Mixer beater
Power consumption (230 V~) 960 W
Rated voltage 230 V~ single-phase
Frequency 50 Hz
No-load speed 0-400 rpm
Max capacity Approx. 30 kg
Max beater diameter 120 mm
Tool holder Female thread M14
Weight 3.2 kg
Protection class II (double insulation)
Protection degree IP20
Sound pressure level 86 dB(A)
Sound power level 97 dB(A)
Hand-arm vibration 0.5 m/s²
Main functions Stirring and mixing paints, adhesives, tile adhesives, mortar, etc.
Start-up On/Off button with lock for continuous operation
Tool change 22 mm open-end wrench (not supplied)
Maintenance and cleaning Clean the ventilation slots regularly; keep the tool clean; have it serviced by a specialist
Spare parts and repairability Repairs exclusively by an authorized Makita service center
Safety Double insulation, protection against electric shock, use with 30 mA residual current device outdoors
Intended use Only for mixing non-explosive and non-flammable materials

Frequently Asked Questions - UT1200 MAKITA

How to change the tool of the Makita UT1200 mixer?
Before any intervention, unplug the device. Use a 22 mm open-end wrench to loosen the beater by turning it counterclockwise. Hold the tool holder spindle with another wrench if necessary. Wear protective gloves to avoid injury during the change.
What types of materials can be mixed with the UT1200?
The UT1200 is designed for stirring and mixing paints, adhesives, tile adhesives, mortar, plasters, leveling compounds, and similar materials, up to a maximum quantity of approximately 30 kg. Never use the device for explosive or flammable materials.
What is the start and stop procedure?
For instant operation, press the On/Off button and release to stop. For continuous operation, press the On/Off button and then lock it with the stop button (lock button). To stop, press the On/Off button again and release.
How to clean and maintain the mixer?
Keep the device and ventilation slots clean. Use a dry cloth or soft brush. Avoid introduction of foreign objects. Have the tool checked by a qualified electrician after each repair. Do not use abrasive products or solvents.
What safety precautions should be observed?
Wear personal protective equipment (goggles, gloves, hearing protection). Hold the device by the insulated gripping surfaces. Never carry the device by the cable. Check the condition of the cable and plug before each use. Outdoors, use a 30 mA maximum residual current circuit breaker.
Can the mixer be used outdoors?
Yes, provided it is connected to a socket protected by a residual current circuit breaker of 30 mA maximum. Avoid any exposure to moisture or rain. Never use the device in a humid environment.
What to do in case of overload or unexpected stop?
If the machine stops for any reason, switch it off immediately by releasing the On/Off button. Let it cool down before restarting. Avoid jamming the tool in the material. If the problem persists, take the device to an authorized Makita service center.
How to interpret vibration and noise levels?
The hand-arm vibration is 0.5 m/s² (uncertainty 1.5 m/s²) and the sound level is 86 dB(A). These values are measured according to EN 60745. Wear hearing protection. To reduce vibration exposure, take breaks and keep the tool in good condition.
Where to get the mixer repaired in case of failure?
Repairs must be carried out exclusively by an authorized Makita service center or a qualified specialist. Never attempt to repair the device yourself, as this could compromise safety. Visit the Makita website to find a service center near you.
Which accessories are compatible with the UT1200?
Use only beaters recommended by Makita, with an M14 thread and a maximum diameter of 120 mm. The beater must be mounted using a 22 mm open-end wrench. Do not use damaged or unsuitable accessories.

User questions about UT1200 MAKITA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Hand blender in PDF format for free! Find your manual UT1200 - MAKITA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UT1200 by MAKITA.

USER MANUAL UT1200 MAKITA

UT 1200UT 1400
Rated voltage:110 V ~230 V ~110 V ~230 V ~
Power input:850 W960 W1050 W1300 W
Rated speed:0-400 rpm0-360 rpm0-560 rpm0-580 rpm
Frequency: 50 Hz
Tool holder:M 14
Safety class: II
Safety degree: IP 20
Weight according to EPTA Procedure 01/2003:3,2 kg5,2 kg

This manual shall be subject to modification without prior notice in the course of developments and technical progress.

Note: The technical data may differ depending on the country.

Symbols

The following symbols are used for the equipment. It is important to know their meaning before you use the tool.

Read instructions
Work with concentration and care. Keep your workplace clean and avoid hazardous situations.
Precautions shall be taken to protect operators.
Double protective insulation

Intended use

The mixer UT 1200 is used to stir and mix p aint, glue, tile adhesive etc. up to an amount of approximately 30kg . The diameter of the stirrers that are used should not exceed 120mm .

The mixer UT 1400 is suitable for stirring and mixing paints, plaster, mortar, tile adhesive, levelling and smoothing compounds, and similar materials up to a quantity of 50kg . The diameter of the mixing agitators must not exceed a value of 140mm .

The user shall be responsible for damages caused by inappropriate use.

Generally accepted accident prevention regulations and the safety instructions enclosed shall be observed.

Power supply

The machine shall only be connected to the voltage stated on the type plate and it only works with single-phase AC voltage. It is provided with double protective insulation according to European standards and thus, it may be also connected to sockets without ground cable.

Do only use extension cables with sufficient cross section. A cross section that is too small may lead to excessive loss of power and overheating of the tool and the cable.

Safety Instructions

WARNING!

Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future reference.

ADDITIONAL SAFETY RULES FOR THIS MACHINE:

  1. If the connecting cable is damaged or cut during work, do not touch it and immediately disconnect the power plug. In any case, do not work with the tool if the connecting cable is damaged.
  2. The tool should not be humid and it should not be operated in a humid environment.
  3. Do not use the tool to mix explosive or easily inflammable substances and do not use it in areas close to these substances.
  4. Do not use the cable to carry the tool.
  5. Do always inspect the tool, the cable and the plug before using it. Repairs shall only be carried out by an expert. The plug shall only be connected to the socket if the tool is switched off.
  6. Do only operate the tool outdoor with a residual current circuit breaker with a maximum of 30mA .
  7. Do not leave the hand-held mixer running unattended.
  8. Do disconnect the power plug and check if the hand-held mixer is switched off when it is left unattended, e.g. during assembly and disassembly work, voltage drop, insertion and/or assembly of accessories.
  9. Do switch off the tool if it stops to operate due to whatever cause in order to avoid a sudden start of operation when it is unattended.
  10. Do always lead the cable away behind the tool.
  11. Do not use the tool if a part of the housing and/or the switch, cable or plug is damaged.
  12. Power tools shall be inspected by an expert regularly.
  13. Do not touch rotating parts.
  14. Be careful with long hair. Do not wear loose clothing.
  15. Do not manipulate the tool.
  16. Do ensure that the handle bars are dry, clean and free from oil and grease.
  17. When the tool is operated manually, make sure that you always hold the tool with both hands and you stand in a firm position. Be aware of the reaction moment of the tool.

  18. Hold power tool by insulated gripping surfaces, when performing an operation where the cutting accessory may contact hidden wiring or its own cord. Cutting accessory contacting a "live" wire may make exposed metal parts of the power tool "live" and could give the operator an electric shock.

Operating the machine

Wrong use may result in damages. Therefore, the following instructions shall always be observed:

Use stirrers recommended by the manufacturer (maximum diameter: 120 mm (UT1200), 140 mm (UT1400) with M14 thread).

Do not overload the machine in a way that causes a standstill.

Tool change

Caution!

Do always remove the power plug before carrying out any work on the tool.

You may catch your fingers when inserting the tool. Therefore, do always wear protective gloves when changing tools.

The work spindle of the tool is provided with a M14 internal thread.

Keep thread and front surfaces clean. Do use a SW 22 spanner to remove the stirrer and to hold up the work spindle.

Switching the machine on and off

Short-Time Operation

Starting the machine: Press on/off switch

Stopping the machine: Release on/off switch

Permanent Operation

Starting the machine: Press on/off switch and while keeping it pressed, engage the lock button

Stopping the machine: Press on/off switch again and release it

The mixer has an electronic switch in order to regulate the speed level by keystrokes.

It is recommended to only use it when the machine is started or stopped in order to avoid splashing material. If the continuous mode is operated with reduced speed, it leads to overstress because the machine is not provided with enough cooling air and overheating will occur significantly faster.

Care and Maintenance

Repairs shall only be carried out by qualified staff trained and experienced in this area. The tool shall be inspected by a skilled electrician after every repair. The power tool is designed to require only a minimum of maintenance and care. However, the following work shall be carried out and/or the following parts shall be inspected regularly:

  • Do always keep the power tool and the ventilation slots clean.
  • Make sure that no foreign objects get into the power tool.
  • If the tool breaks down, the repair shall only be carried out by an authorised shop.

Information on noise and vibration

Measured values determined according to EN 60745

The A-weighted noise level of the tool is typically:

UT 1200UT 1400
Sound pressure level (LPA) 86 dB(A)86 dB(A)
Sound power level (LWA) 97 dB(A)97 dB(A)
Uncertainty K 3 dB3 dB

Wear ear protection!

UT 1200UT 1400
Hand-arm vibration: 1,05 m/s20,5 m/s2
Uncertainty K 1,5 m/s21,5 m/s2

Measured values determined according to EN 60745

The vibration emission level indicated in these instructions has been measured in accordance with a standardised test method given in EN 60745 and can be used to compare one tool with another. It is also suitable for a preliminary evaluation of the vibration emission level.

The vibration emission level set out in these instructions presents the main applications of the power tool. If the power tool is used for other applications or with different tools or if maintenance is not sufficient, the vibration emission level may vary. This may lead to a significantly higher vibration emission level during the whole working period.

In order to be accurate, an estimation of the level of exposure to vibration should also take into account the times when the tool is switched off and when it is running but not actually used. This may significantly reduce the level of exposure to vibration during the whole working period.

Additional protective measures in order to protect the operator from vibration effects, e.g. maintenance of power tools and tools, keeping hands warm, organisation of work processes, shall be determined.

Environmental Protection

MAKITA UT1200 - Environmental Protection - 1

Only for EU countries

In observance of the European Directive 2012/19/EC on waste electrical and electronic equipment and its implementation in accordance with national law, electric tools that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility.

EC Declaration of Conformity

We Makita Corporation as the responsible Manufacturer declare that the following Makita Machine(s):

Designation of Machine: Hand-Held Mixer

Model No / Type: UT 1200 / UT 1400

Are of series production and

Conforms to the following European Directives:

2006/42/EC

And are manufactured in accordance to the following standards or standardised

Documents:

EN 60745

In observance of European Directive on waste electrical and electronic equipment and its implementation in accordance with national law.

The Technical Documentation is kept by:

Makita International Europe Ltd,

Technical Department

Michigan, Drive, Tongwell,

Milton Keynes, Bucks MK15 8JD, England.

01.04.2013

MAKITA UT1200 - Conforms to the following European Directives: - 1

Tomoyasu Kato

Director

Responsible manufacturer

Makita Corporation

3-11-8, Sumiyoshi-cho, Anjo, Aichi, 446-8502 JAPAN

Authorised representation in Europe:

Makita International Europe Ltd.

Michigan Drive, Tongwell, Milton Keynes

Milton Keynes Bucks MK15 8JD, England

FRANÇAIS

\section*{Caracteristiques techniques}

Technical Department

Michigan, Drive, Tongwell,

Milton Keynes, Bucks MK15 8JD, England.

01.04.2013

MAKITA UT1200 - FRANÇAIS - 1

Tomoyasu Kato

Director

Fabricant responsible

Makita Corporation

3-11-8, Sumiyoshi-cho, Anjo, Aichi, 446-8502 JAPAN

Michigan Drive, Tongwell, Milton Keynes

Milton Keynes Bucks MK15 8JD, England

DEUTSCH

Technische Daten

Technical Department

Michigan, Drive, Tongwell,

Milton Keynes, Bucks MK15 8JD, England.

01.04.2013

MAKITA UT1200 - DEUTSCH - 1

Tomoyasu Kato

Direktor

Michigan Drive, Tongwell, Milton Keynes

Milton Keynes Bucks MK15 8JD, England

ITALIANO

Technical Department

Michigan, Drive, Tongwell,

Milton Keynes, Bucks MK15 8JD, England.

01.04.2013

MAKITA UT1200 - ITALIANO - 1

Tomoyasu Kato

Direttore

Michigan Drive, Tongwell, Milton Keynes

Milton Keynes Bucks MK15 8JD, England

NEDERLANDS

Technische specificaties

UT 1200UT 1400
Nominate spanning:110 V ~230 V ~110 V ~230 V ~
Opgenomen vermogen:850 W960 W1050 W1300 W
Belast snelheid:0-400 min-10-360 min-10-560 min-10-580 min-1
Frequentie: 50 Hz
Gereedschapsopname:M 14
Beschermingsklasse:II
Beschermingsniveau:IP 20
Gewicht in overeenstemming met EPTA-procedure 01/2003:3,2 kg5,2 kg

Technical Department

Michigan, Drive, Tongwell,

Milton Keynes, Bucks MK15 8JD, England.

01.04.2013

MAKITA UT1200 - NEDERLANDS - 1

Tomoyasu Kato

Director

Michigan Drive, Tongwell, Milton Keynes

Milton Keynes Bucks MK15 8JD, England

ESPAÑOL

Datasétécnicos

Michigan, Drive, Tongwell,

Milton Keynes, MK15 8JD, Inglaterra.

01.04.2013

MAKITA UT1200 - ESPAÑOL - 1

Tomoyasu Kato

Director

Fabricante responsible

Makita Corporation

3-11-8, Sumiyoshi-cho, Anjo, Aichi, 446-8502 JAPON

Michigan Drive, Tongwell, Milton Keynes

Milton Keynes Bucks MK15 8JD, Inglaterra

PORTUGUES

Dados技术和

Michigan, Drive, Tongwell,

Milton Keynes, MK15 8JD, Inglaterra.

01.04.2013

MAKITA UT1200 - PORTUGUES - 1

Tomoyasu Kato

Diretor

Fabricante responsavel

Makita Corporation

3-11-8, Sumiyoshi-cho, Anjo, Aichi, 446-8502 JAPAO

Michigan Drive, Tongwell, Milton Keynes

Milton Keynes Bucks MK15 8JD, Inglaterra

DANSK

Tekniske data

Technical Department

Michigan, Drive, Tongwell,

Milton Keynes, Bucks MK15 8JD, England.

01.04.2013

MAKITA UT1200 - DANSK - 1

Tomoyasu Kato

Direktør

Ansvarlig fabrikant

Makita Corporation

3-11-8, Sumiyoshi-cho, Anjo, Aichi, 446-8502 JAPAN

Autorisernet afdeling i Europa:

Makita International Europe Ltd.

Michigan Drive, Tongwell, Milton Keynes

Milton Keynes Bucks MK15 8JD, England

EAAHNIKA

TEXNIKA XAPAKTHPIETIKA

Michigan, Drive, Tongwell,

Milton Keynes, MK15 8JD, England.

01.04.2013

MAKITA UT1200 - EAAHNIKA - 1

Tomoyasu Kato

△εuθuvtns

Yπεúθuvoc kataακεuaatnc

Makita Corporation

3-11-8, Sumiyoshi-cho, Anjo, Aichi, 446-8502 JAPAN

EouoiobotnuevoeKtpooswtoC otny Eupwn:

Makita International Europe Ltd.

Michigan Drive, Tongwell, Milton Keynes

Milton Keynes Bucks MK15 8JD, England

Makita Corporation

Anjo, Aichi, Japan

www.makita.com

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : MAKITA

Model : UT1200

Category : Hand blender