TFA 30.5050.54 - Digital thermometer hygrometer

30.5050.54 - Digital thermometer hygrometer TFA - Free user manual and instructions

Find the device manual for free 30.5050.54 TFA in PDF.

📄 48 pages English EN Download 💬 AI Question ⚙️ Specs
Notice TFA 30.5050.54 - page 11
SKIP

Frequently Asked Questions - 30.5050.54 TFA

User questions about 30.5050.54 TFA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

L'email reste privé : il sert seulement à vous prévenir si quelqu'un répond à votre question.

No questions yet. Be the first to ask one.

Download the instructions for your Digital thermometer hygrometer in PDF format for free! Find your manual 30.5050.54 - TFA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 30.5050.54 by TFA.

USER MANUAL 30.5050.54 TFA

Thank you for choosing this instrument from TFA.

1. Before you use this product

  • Please make sure you read the instruction manual carefully. This information will help you to familiarize yourself with your new device, to learn all of its functions and parts, to find out important details about its first use and how to operate it and to get advice in the event of a malfunction.
  • Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
  • We shall not be liable for any damage occurring as a result of non-following of these instructions. Likewise, we take no responsibility for any incorrect readings or for any consequences resulting from them.
  • Please take particular note of the safety advice!
  • Please keep this instruction manual safe for future reference.

2. For your safety

The product should only be used as described within these instructions.

FUN-Digital thermo-hygrometer

GB

  • Unauthorized repairs, alterations or changes to the product are prohibited.

TFA 30.5050.54 - FUN-Digital thermo-hygrometer - 1

Caution! Risk of injury:

  • Keep this instrument and the batteries out of reach of children.
  • Batteries contain harmful acids and may be hazardous if swallowed. If a battery is swallowed, this can lead to serious internal burns and death within two hours. If you suspect a battery could have been swallowed or otherwise caught in the body, seek medical help immediately.
  • Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk of explosion!
  • Low batteries should be changed as soon as possible to prevent damage caused by leaking. Never use a combination of old and new batteries together, nor batteries of different types.
  • Wear chemical-resistant protective gloves and safety glasses when handling leaking batteries.

Important information on product safety!

  • Do not expose the device to extreme temperatures, vibrations or shocks.
  • Protect it from moisture.

3. Elements

3.1 Display (Fig. 1)

A 1: DCF reception symbol
A 2: Time
A3:Date
A 4: Smiley for the comfort level
A 5: Indoor humidity
A6:Automatic reset
A7:Max/min values
A 8: Manual reset
A 9:Indoor temperature
A 10: Battery symbol

FUN-Digital thermo-hygrometer

GB

3.2 Buttons (Fig. 2)

B1:SET button
B2:MIN/MAX button
B3: + button

3.3 Housing (Fig. 3)

C1: Stand (fold out)
C 2: Suspension de
C3: Battery compartment

4. Getting started

  • Remove the protective film from the display.
  • Open the battery compartment and insert two new AAA 1.5 V batteries, polarity as illustrated.
  • Close the battery compartment again.
    All segments will be displayed briefly.
    The device is ready for use.

4.1 Radio-controlled time reception

The clock will now scan the DCF frequency signal and the DCF symbol will be flashing on the display.

FUN-Digital thermo-hyrometer

GB

  • All other information disappears from the display. During the DCF time reception period, no button can be pressed.
  • When the time code is successfully received after 3-10 minutes, the radio-controlled time, the date and the DCF symbol will be shown steadily on the display.
  • The indoor temperature, the humidity and the corresponding smiley symbol appear on the display.
  • Interrupt the reception by pressing the SET button for 3 seconds.
  • The DCF reception always takes place daily at 1:00, 2:00 and 3:00 o'clock in the morning. If the reception is not successfully received, another DCF reception will take place the next full hour (up to 2 times).
  • You can also activate the DCF reception manually. Press the SET button. The DCF reception symbol flashes.
  • If the clock cannot detect the DCF-signal (e.g. due to interference, transmitting distance, etc.), the time can be set manually. The DCF reception symbol disappears and the clock will then work as a normal quartz clock (see: Manual settings).
  • Once the DCF time signal is successfully received and the DCF reception is activated (dcF ON), the manually set time is overwritten.

FUN-Digital thermo-hygrometer

GB

Note on radio-controlled time

The time base for the radio-controlled time is a caesium atomic clock operated by the Physikalisch Technische Bundesanstalt based in Braunschweig (Brunswick), Germany. It has a time deviation of less than one second in one million years. The time is coded and transmitted from Mainfingen near Frankfurt via the frequency signal DCF-77 (77.5 kHz) and has a transmitting range of approximately 1,500 km. Your radio clock receives the signal, converts it and always shows the exact time. The adjustment to Daylight Saving Time (summer/winter time) is automatic. The reception quality depends mainly on geographic location. Normally there should be no reception problems within a 1,500 km radius around Frankfurt.

Therefore, please note the following steps:

  • The recommended distance to any interfering sources like computer screens or TV sets is at least 1.5 - 2 meters.
  • Within concrete walls (reinforced with steel) such as basements, the received signal is naturally weakened. In extreme cases, please place the unit close to a window to improve reception.

FUN-Digital thermo-hyrometer

GB

  • During night-time, the atmospheric interference is usually less severe and reception is possible in most cases. A single daily reception is adequate to keep the accuracy deviation under 1 second.

5. Operation

The device will automatically quit the setting mode if no button is pressed for 20 seconds.

  • Press and hold the + button in the respective setting mode for quick setting.

5.1 Manual settings

  • Press and hold the SET button for 3 seconds to enter the setting mode.

5.1.1 Temperature unit setting

  • ^ C flashes in the display.
  • Press the + button to change between °C (Celsius) or °F (Fahrenheit) as temperature unit.
  • Confirm with the SET button.
  • If you set Fahrenheit as temperature unit, the time will be shown automatically in 12 hours system (AM/PM) and the date in month/ date sequence (American version).

FUN-Digital thermo-hygrometer

GB

5.2 Setting DCF reception

  • dCF on flashes. By default, the DCF reception is activated (on).
  • Press the + button if you want to deactivate the DCF reception (OFF) or activate again (on).
  • Confirm with the SET button.
  • Once the DCF time reception is deactivated the clock must be manually set. No time zone will appear.

5.3 Setting of the time zone

  • ZOnE 0 flashes.
    The time zone correction is needed for countries where the DCF signal can be received but the time zone is different from the DCF time (e.g. 1=one hour plus).
  • Press + button to correct the hours for the DCF time (+3/-3).

5.4 Setting of the time and date

  • Press the SET button to make the settings in the following sequence: Hours, minutes, year, month and day. Press + button to adjust it.
  • Confirm with the SET button.

FUN-Digital thermo-hyrometer

GB

5.5 Reset of the maximum-minimum values

MIN MAX MANUAL flashes.
- Press the + button to select the automatic (AUTO) or manual (MANUAL) reset mode of the maximum-minimum values.
- Confirm with the SET button.

5.5.1 Manual reset mode

5.5.2 Automatic reset mode

The maximum and minimum values are only reset manually.
- The maximum and minimum values are automatically reset at midnight. Manual reset is also possible.

6. Indication of maximum and minimum values

  • Press the MIN/MAX button in normal mode.
    MIN appears on the display.
    The minimum values measured since the last reset appear on the display.
  • Press the MIN/MAX button again.
    MAX appears on the display.
    The maximum values measured since the last reset appear on the display.

FUN-Digital thermo-hygrometer

GB

  • Press the MIN/MAX button again, to go back to the display of the present values.
    The device will automatically quit the MIN/MAX mode if no button is pressed for 5 seconds.
    To clear the recorded maximum or minimum readings, press and hold the MIN/MAX button for three seconds while the maximum or minimum values are displayed.

7. Comfort level

  • For the indication of the comfort level of the indoor climate on the display appears:
Laughing face Ideal values
19...25°C 40...55%
Neutral face 26...30°C 30...39%
56...60%
Sad face≤18°C, ≥31°C≤29%, ≥61%
Sad face
DRY too dry ≤ 29%

FUN-Digital thermo-hyrometer

GB

Sad face

WET too wet ≥61%

8. Positioning and fixing

  • The device can be placed onto any flat surface with the foldable stand found at the back of the unit. Press firmly with both thumbs until the stand is properly locked in place and a click is heard.
    The device can be wall mounted at a chosen location by the mounting hole found at the back of the unit.
  • Avoid radiators and direct sunshine.

9. Care and maintenance

Clean the device with a soft damp cloth. Do not use solvents or scouring agents.
- Remove the batteries if the device will not be used for an extended period of time.
- Keep the device in a dry place.

9.1 Battery replacement

  • When the batteries are used up, the low battery icon appears on the display.

FUN-Digital thermo-hygrometer

GB

  • Open the battery compartment and insert two new AAA 1.5 V batteries, polarity as illustrated.
  • Close the battery compartment again.

10. Troubleshooting

Problem Solution

No display Ensure the batteries' polarities are correct
Change the batteries

No DCF reception Activate DCF reception in setting mode (On)

Press the SET button to activate the DCF reception manually
Choose another place for your product
Wait for an attempt reception during the night
Check if there is any source of interference

FUN-Digital thermo-hyrometer

TFA 30.5050.54 - FUN-Digital thermo-hyrometer - 1

Restart the instrument according to the manual
Set the clock manually

Incorrect indication Change the batteries

11. Waste disposal

This product has been manufactured using high-grade materials and components which can be recycled and reused.

TFA 30.5050.54 - Waste disposal - 1

Never dispose of empty batteries and rechargeable batteries with ordinary household waste. As a consumer, you are required by law to take them to your retail store or to an appropriate collection site depending on national or local regulations in order to protect the environment.

The symbols for the contained heavy metals are: Cd = cadmium, Hg = mercury, Pb = lead

This product is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE).

FUN-Digital thermo-hygmometer

TFA 30.5050.54 - FUN-Digital thermo-hygmometer - 1

Please do not dispose of this product in ordinary household waste. As a consumer, you are required to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal.

12. Specifications

Power consumption: 2 × 1,5V AAA batteries (not included)

Measuring range - temperature 0^ + 50^ (+32 + 122^) Accuracy ± 1^

Measuring range humidity: 10% 99% RH Accuracy ± 5% @30...80%

Housing dimension 88 x 19 (44) x 88 mm

Weight 68 g (device only)

TFA 30.5050.54 - Specifications - 1

TFA 30.5050.54 - Specifications - 2

TFA 30.5050.54 - Specifications - 3

TFA 30.5050.54 - Specifications - 4

FUN-Digital thermo-hyrometer

GB

No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice.
The latest technical data and information about this product can be found in our homepage by simply entering the product number in the search box.
EU Declaration of conformity
Hereby, TFA Dostmann declares that the radio equipment type 30.5050 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following Internet address:
www.tfa-dostmann.de
E-Mail: info@ta-fadostmann.de
TFA Dostmann GmbH & Co.KG
Zum Ottersberg 12, D-97877 Wertheim, Germany 08/19

B1:Touche SET
B2:Touche MIN/MAX
B3:Touche+

3.3 Boitier (Fig. 3)

Visage neutre 26...30°C 30...39%
56...60%
Visage trist≤18°C, ≥31°C≤29%, ≥61%
Visage trist
DRY trop sec ≤ 29%
Visage trist
WET trop humide ≥61%
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : TFA

Model : 30.5050.54

Category : Digital thermometer hygrometer