Joycare JC138G - Thermometer

JC138G - Thermometer Joycare - Free user manual and instructions

Find the device manual for free JC138G Joycare in PDF.

📄 56 pages English EN Download 💬 AI Question
Notice Joycare JC138G - page 9
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about JC138G Joycare

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometer in PDF format for free! Find your manual JC138G - Joycare and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. JC138G by Joycare.

USER MANUAL JC138G Joycare

Thanks to its infrared sensors, the Joycare's thermometer detects heat of arterial rush in correspondence of forehead or of auricular canal. Forehead is supplied by temporal artery, which carries blood from heart to brain; if you slide the probe from the arch of forehead to temple, the thermometer will immediately detect body

temperature in a accurate and reliable way. This is an easy and an efficacious way to measure, with numerous advantages: it is rapid, ideal to be used with children, even when they are sleeping.

DESTINATION OF USE AND REFERENCE RULES

This electric digital Joycare's thermometer JC-138G is an instrument to measure body temperature for clinical and hospital use, and moreover for domestic use whenever it is not necessary continuous watch by medical and paramedical staff. The instrument can be used on forehead and it must be used

following scrupulously the indicated instructions in this manual: every use different from that prescribed is illegitimate. This is a product conformable to the following rules: - EN 60601-1: + A1: + A2: + A13: - electro medical devices.

Part 1: general rules for security; - EN 60601-1-2: -electro medical devices.

Part 1: general rules for security. Part 2 - collateral rule: electromagnetic compatibility - prescriptions and test; - UNI EN 12470-5: clinical thermometers.

Part 5: performance of infrared thermometer. Digital infrared thermometer Joycare JC-138G is a medical device of class IIa. Classification according to clause 3.2, section 3, rule 10 of directive 93/42/CEE.

GENERAL INFORMATION

Mean temperature varies from person to person depending on sex, age and different parts of the day. It can go from a minimum of 35.5^ ( 95.9^ ) to 37.8^ ( 100.4^ ). Thereby, when you are in good health, it is suggested to effect different consecutive measurements to state the range of your own mean temperature.

READ ACCURATELY USER MANUAL PRECAUTIONS

  • Use the device only with the aim it was built for.
  • To do accurate measurements, be sure that the probe is integral, clean and dry (see maintenance).
  • Avoid measuring your temperature for at least 30 minutes after having done an intense physical work, having eaten and having had a bath.
  • Don't expose the instrument to high temperature, to direct sunbeams and to dust.
  • Keep the thermometer in its holder.
  • Avoid to knock it off.
  • Be careful to follow the instructions for a correct position and use.
  • Don't try to open or repair the instrument alone: the guarantee would decay.
  • Don't disassemble the instrument, except to remove or substitute the battery.

  • In case of breakdown turn to a specialized centre.

  • Don't put fingers or objects into the probe.
  • To clean the instrument use a soft cloth soared with alcohol; never use aggressive chemicals or detergents.
  • To clean the probe use some cotton soared with alcohol.

HOW TO PROCEED TO MEASURE

  • Push the switching on button: to be sure of a correct operation, when you switch on the device check that display shows in order: all the segments lighted for few seconds the last temperature detected, then Lo^
  • Bring the thermometer's probe near to forehead in the centre, under the hairline, paying attention the probe not to come completely in contact with skin (distance less than 1 cm)
  • Slide the device toward to the temple with a continuous movement, up to the temple.
  • The temperature will be detected in 3-4 seconds and display will immediately visualize it.

Note: If you dry or wash your forehead, skin could become cooled. As a result measurement of the temperature could not be reliable anymore. In this case it is suggested to measure through the auricular canal: place the probe in the auricular canal and after 2-3 seconds the thermometer will detect temperature.
- If the detected temperature seems to be not reliable or instable, it is suggested to call the authorized service to check that the device works correctly or call our own doctor for a consulting.
- Push the button again to effect a new measurement.
- Before going on measuring, make sure your skin to be dry and clean (skin must be always clean, not sweaty, not wet of water or oil). Follow the instructions with attention and move delicately the thermometer, in light contact with skin.

PARTICULAR INSTRUCTIONS

  • The movement through the forehead is necessary to find the point of the highest temperature.
  • Read carefully the instruction manual before using.
  • When high temperature persists, turn to our own doctor.

AUTOMATIC SWITCHING OFF

The device switches off automatically when it is not in use for about 60 seconds.

MEMORY FUNCTION

The thermometer keeps in memory the last measurement done

MAINTENANCE

Cleaning the product

Before and after using always clean the thermometer with a soft cloth dampened of water or of alcohol diluted with water. Store the device in its plastic box. Do not dip the device in water or other liquids.

THE PARTS OF THE PRODUCT

Joycare JC138G - THE PARTS OF THE PRODUCT - 1

MEMORY FUNCTION

The thermometer stores the previous 8 measurements. The last measurement appears on the display when the thermometer is turned on.

Replacing the battery

Before using the product, remove the plastic film between the battery's poles and the contacts.

Joycare JC138G - Replacing the battery - 1

Replace the battery when the 'flat battery' icon display.

Joycare JC138G - Replacing the battery - 2

appears on the

Joycare JC138G - Replacing the battery - 3
Fig.9.3

Joycare JC138G - Replacing the battery - 4
Fig.9.4

Joycare JC138G - Replacing the battery - 5
Fig.9.5

1-Open the battery compartment
2-Remove the old battery
3-Replace with a new CR2032 battery

The symbols and their meanings

8888Display
Temperature measurement in progress
Temperature is above 38°C
Temperature test mode at front
M8Temperature memory
Flat battery
°ETemperature measurement unit (C° or F°)
Timer function
ErrRoom temperature is above 40°C or below 10°C
H1Body temperature measurement is above 42.9°C
LoBody temperature measurement is below 32°C
Room temperature

Configuring the time

Joycare JC138G - Configuring the time - 1

1-Press the TIME buttons once to enter time configuration mode. The hour digits start flashing.
2-Press the STATUS button to decrease and SET to increase
3-Press TIME again to configure the minutes
4-Press the STATUS button to decrease and SET to increase
5-Press TIME again to confirm configuration

MEASUREMENT UNIT

To change the measurement unit, open the battery compartment and set the small button at C^ or F^ (depending on which measurement unit you wish to have on the display)

RETRIEVING STORED TEMPERATURES

To retrieve one of the 8 saved temperatures:

1-Press the STATUS button to select the memory function (the memory icon appears on the display)

Joycare JC138G - RETRIEVING STORED TEMPERATURES - 1

e SET button to find the saved temperature you require

TECHNICAL FEATURES

Temperature range 34.0^ 42.0^

Division 0.1^

Precision 35.5^ 42.0^ ± 0.2^ others ranges ± 0.3^

Icons visualized on the display in normal conditions [from 35.5^ to 37.5^ ]

Icons visualized on the display in instable conditions [from 37.6^ to 37.9^]

Icons visualized on the display in case of fever [from 38.0^ to 42.0^ ]

Detection time About 3-4 seconds

Display LCD

Memories Last measurement

Power source Internal electric source: 1 X CR2032

Kind of sensor Infrared

Using conditions Temperature: +10^ 40^

humidity 10 80% RH

Transport and storage conditions Temperature: -20^ 60^

humidity 10 95% RH

INFORMATION ON ELECTROMAGNETIC COMPATIBILITY

This medical device needs special care as far as electromagnetic compatibility is concerned. It must be installed and used in compliance with the information given in the accompanying documents. Portable and mobile radiocommunication appliances may affect the operation of the thermometer.

MANUFACTURER'S GUIDE AND DECLARATION-ELECTROMAGNETIC EMISSIONS

The clinical thermometer JC-138G can be used in the following electromagnetic environment. The customer or user of the clinical thermometer JC-138G must make sure that the device is used in said environment.

EMISSION TEST COMPLIANCE GUIDE TO THE ELECTRO

MAGNETIC ENVIRONMENT
IRRADIATED EMISSIONS / CISPR11Group 1The clinical thermometer JC-138G uses RF energy for its internal operation only. Consequently its RF emissions are very low and cause no interference close to electronic appliances.

MANUFACTURER'S GUIDE AND DECLARATION-ELECTROMAGNETIC IMMUNITY

The clinical thermometer JC-138G can be used in the following electromagnetic environment. The customer or user of the clinical thermometer JC-138G must make sure that the device is used in said environment.

EMISSION TEST COMPLIANCE GUIDE TO THE ELECTRO

All the indications, specifications and drawings are based on the latest information available when this manual was printed. They can be subject to variations or changes with no notice required.

Joycare JC138G - MANUFACTURER'S GUIDE AND DECLARATION-ELECTROMAGNETIC IMMUNITY - 1

Consult attached documentation

Joycare JC138G - MANUFACTURER'S GUIDE AND DECLARATION-ELECTROMAGNETIC IMMUNITY - 2

Applied parts type B

Joycare JC138G - MANUFACTURER'S GUIDE AND DECLARATION-ELECTROMAGNETIC IMMUNITY - 3

0413

JC-138G is conformable to all applicable rules in accordance to directive 93/42/CEE

Joycare JC138G - MANUFACTURER'S GUIDE AND DECLARATION-ELECTROMAGNETIC IMMUNITY - 4

DISPOSAL

The device (including its removable parts and accessories) must not be disposed of together with municipal waste at the end of its

life, but in compliance with European Directive 2002/96/EC. Since it must be handled separately from household waste, either carry it to a separatelycollected waste disposal centre for electrical and electronic appliances or give it back to the retailer on purchasing a new device with the same purpose. Any infringement will be severely prosecuted.

The batteries used in this device must be disposed of in the special bins at the end of their life.

Produced in CHINA by FARMIDOC TECHNOLOGY CO., LTD. 6/F G BUILDING, NO 14 LIUXIAN 1ST RD, 71 BLOCK, BAOAN DISTRICT, SHENZHEN, CHINA

Manufacturer Legal representative in UE : VSIOMED FRANCE

111 RUE DE STALINGRAD, 93100 MONTREUIL FRANCE

Distribuited with Joycare brand by JOYCARE S.p.A.,

THERMOMÉTURE DIGITAL

FONCTIONNEMENT DU THERMOMÉTURE AUX INFRAROUGES.

JC-138G DIGITAL THERMOMETER

FUNKTIONSWEISE EINES INFRAROT THERMOMETERS

División 0.1^

Precisión 35.5 ~ 42.0°C ± 0.2°C;其中之一 intervalos ± 0.3°C

Visualización en conditiones normales [de 35.5^ a 37.5^]

Visualización en la pantalla [de 37.6^ a 37.9^]

Visualización la pantalla en caso de fiebre [de 38.0^ a 42.0^ ]

a a a a a a a a a a a a a a a a a a a a a a a

#

i

a a a a a a a a a a a a a a a a a a a a a a a a a a a a

Joycare JC138G - i - 1

aannnnn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn

jll jlae gJlal Jgliae laLd yll sla:

01

Joycare JC138G - i - 2

gialll 1

(2)

aJrall j (3)

(4)

(5)

(6)

(7)

Jilu Jilu Jiu jiyue li li (8)

(9)

jz (10)

(11)

(12)

S_ OBC = S_ COD + S_ BOC

a a a a a a a a a a a a a a a a a a a a a a a a a

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 1

J

juaa jaaai jae aai jae aai aai aai aai

y 1

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 2

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 3
Fig. 9.3

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 4
Fig.94

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 5
Fig.9.5

( 2) Sn = na1 + ( n - 1) 2

aaiy

2032CR

jggg Cdo

a1^2 + a2^2 + a_3^2 = 8

aallll lalll

a

aill 1000

a 2

A = A + B + C

()

aclwll a

  1. 1

4 19,9 jaojai jao jao jao jao jao

y j 1

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 1

1

2

(TIME)

SET) (STATUS

(TIME)

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 1

y 1

(1)

a 1

: 0jlll j 0j 0j 0j 0j 0j 0j

(STATUS)

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 1

(SET)

algal

4yjzjzj 1

4.2.1

0.3±gjCllbi 0.2±gjzj

[4yia 1V,0 yia yia a 10,0] aaii bll iil jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jai jali

[4] 12, 19, 20

J 1

LCD

0c1 jj j0c1 g g jlll a

2032x CR1 8

el jall cai aaiy jaii yjoi

a yio 1 + a yio 1 + j0: oJyai Jyai

% 1 : 43 此方法.

y 1

% 90 1.1 : 12a + b = 1

j

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 2

aee aee

i j

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 3

Joycare JC138G - S_ OBC = S_ COD + S_ BOC - 4

0413

EN93/42/CEB

gai gai y

jss (y) EMC y JOYCARE

e 1

Jaaall aal algall gall aal flln jssaall no

Joycare S.p.A., a company with a sole shareholder, offers a period of 2 year warranty after the date of purchase. The warranty does not cover damage caused by accidental breakage, transportation, incorrect maintenance or cleaning, misuse, tampering or repairs carried out by non authorised third parties. The following is also excluded: damage caused by incorrect product installation, and damage caused by wear and tear, obviously including parts subject to wear and tear. In order to obtain the replacement/repair of products under warranty in cases other than those mentioned above, but which are instead caused by manufacturing defects, please contact your local importer/distributor. Goods that are not held to be in good condition because of the aforesaid causes must be accompanied by this certificate, duly filled-in, as well as a receipt for the goods (invoices and transport documents) and purchasing documentation.

Please keep the original packaging of the product.

F: CARTE DE GARANTIE

PRODUCT/SERIAL NUMBER/MODEL

PRODUIT / NUMERO DE SÉRIE/ MODELE DU PRODUIT

PRODUKT / SERIENNUMMER / MODELL

PRODUTO / NUMERO DE SERIAL/ MODELO

PRODUCTO/NUMERO DESE

INPOJYKT/CEPNEH/MOJI

PRODUS/SEBIA NUMABUL/MODEL

TERMÉK/SOROZATSZÁM

111/1

INDIRZZC

SENDER

EXPEDITEUR

ABSENDER

BEMITENTE

BEMITENTE

ADPEC

EXPEDITOR

CIM

1

DATA DI ACQUISTO

DATE OF PURCHASE

DATE D'ACHAT

KAUFDATUM

DATA DE COMPRA

FECHA DE COMPRA

3AKYNYBAHE DATA

DATA CUMPÁRÁII

BESZERZÉS DátUMA

NOME E TIMBRO DEL RIVENDITORE

DEALER NAME AND STEMPEL

NOME ET TIMBRE DU REVENDEUR

NAME UND STEMPEL DES HANDLERS

REVENDEDOR NOMBRE

NOME DE NEGOCIANTE

IMEMIPEYAT HA TBPROBCKN IPEICTABNTEJI

NUMELE VANZATORULUI SI STAMPILA

A VISZONTELADO NEVE ES PECSETJE

#

Joycare JC138G - # - 1

REV.00-SEPT2010

MADE IN CHINA

154--45-gawla 4j

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Joycare

Model : JC138G

Category : Thermometer