Joycare JC132G - Thermometer

JC132G - Thermometer Joycare - Free user manual and instructions

Find the device manual for free JC132G Joycare in PDF.

📄 48 pages English EN Download 💬 AI Question
Notice Joycare JC132G - page 8
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about JC132G Joycare

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometer in PDF format for free! Find your manual JC132G - Joycare and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. JC132G by Joycare.

USER MANUAL JC132G Joycare

This digital electric thermometer model Joycare JC-132G is suitable to take body temperature for clinical and hospital use as well as for home use, as long as medical or paramedical staff are not required to be present at all times. The device was designed for oral use strictly in compliance with the instructions specified in this manual. Any use different from the use specified will be deemed improper use.

The product complies with the following standards: - EN 60601-1: + A1: + A2: + A13: - Electromedical Appliances. Part 1: General Safety Regulations; - EN 60601-1-2: -

Electromedical Appliances. Part 1: General Safety Regulations. Part 2 - Collateral Regulation: Electromagnetic Compatibility - Provisions and Tests; - UNI EN 12470-3: Clinical Thermometers - Compact Electric Thermometers Equipped with Maximum Temperature Device. The digital electric thermometer model Joycare JC-132 is a medical device belonging to Class IIa. Classification according to Clause 3.2, Section 3, Rule 10 of Directive 93/42/EEC.

WARNING

Check the bulb before use: do not use the thermometer if the rubber is torn. Do not use the product as an ordinary dummy. Do not drop the thermometer. Do not let the product come into contact with solvents. Avoid exposure to and contact with heat sources. Do not immerse the bulb in sweet substances. No not tie the thermometer to the baby's neck. Do not disassemble the product.

WHAT IS A “NORMAL” TEMPERATURE?

The generally accepted "normal" temperature for child is between 36.5 to 37.5^ / 97.7 to 99.5^

This pacifier thermometer is the most convenient equipment for you to measure your child's temperature. Never measure temperature within 30 minutes after the baby had intake hot or cold drink since it will inaccurate the measurement. Please follow the procedure list below to taking your baby temperature.Remove the protective cover; Wash the thermometer with mild soap and warm water.Rinse thoroughly with cool water. Press ON/OFF button to activate. The thermometer will beep once for about 0.5 second and the display will show icon Lo. below for around 2 seconds. Place the pacifier in the baby's mouth and leave it there until the thermometer beeps continuously. Remove the pacifier from the baby's mouth. Push the on/off button to switch off the thermometer as this will help to extend the life of the thermometer. The thermometer will switch off automatically around after 8 minutes of the measurement. Read and record the temperature and time after each measuring for reference. The reading will also automatically stored in the memory; Press the ON/OFF button to turn off the thermometer. The thermometer will switch off automatically after it is idle in 8 minutes. Clean the thermometer, cover the thermometer with the protective cover provided and store it out of reach of child. Turn thermometer off and back on. While turn on the thermometer again, press and hold ON/OFF button over 2 seconds, the temperature unit ^ & ^ will changed accordingly.

Now the thermometer can be used to measure temperature in the unit that shows on the upper right hand corner of the display window. Repeat the above process to reverse the measurement unit if desired.

The last temperature is always stored in the memory automatically; The last temperature will display on the display window when you switch on the thermometer again. It will show up on the display window after you heard the beep when you switch on the thermometer

CLEANING

The thermometer is water-proof. Clean it with warm AND NOT HOT water! Sterilise the teat with alcohol and rinse with cold water. Always check the bulb before use: do not use the thermometer if the rubber is torn.

INFORMATION ON ELECTROMAGNETIC COMPATIBILITY

This medical device needs special care as far as electromagnetic compatibility is concerned. It must be installed and used in compliance with the information given in the accompanying documents. Portable and mobile radiocommunication appliances may affect the operation of the thermometer.

MANUFACTURER'S GUIDE AND DECLARATION - ELECTROMAGNETIC EMISSIONS
The clinical thermometer JC-132G can be used in the following electromagnetic environment. The customer or user of the clinical thermometer JC-132G must make sure that the device is used in said environment.
EMISSION TEST COMPLIANCEGUIDE TO THE ELECTROMAGNETIC ENVIRONMENT
IRRADIATED EMISSIONS / CISPR11 Group 1The clinical thermometer JC-132 uses RF energy for its internal operation only. Consequently its RF emissions are very low and cause no interference close to electronic appliances.
MANUFACTURER'S GUIDE AND DECLARATION - ELECTROMAGNETIC IMMUNITY
The clinical thermometer JC-132G can be used in the following electromagnetic environment. The customer or user of the clinical thermometer JC-132G must make sure that the device is used in said environment.
EMISSION TEST COMPLIANCEGUIDE TO THE ELECTROMAGNETIC ENVIRONMENT
Electrostatic discharges (ESD)IEC/EN61000-4-2±6kV in contact±8kV in the airThe floors should be made of wood, cement or baked clay. If the floors are covered in synthetic material, relative humidity should not exceed 30%.
Magnetic fieldIEC/EN 61000-4-83 A/mThe magnetic field should be the typical magnetic field of a commercial or hospital environment.
Irradiated immunityIEC/EN61000-4-63 V/m 80 MHz at 2.5 GHz (in appliances that are not life equipment)

All the indications, specifications and drawings are based on the latest information available when this manual was printed. They can be subject to variations or changes with no notice required.

SYMBOL

Joycare JC132G - SYMBOL - 1

applied parts Type B

see attached documents

Joycare JC132G - SYMBOL - 2

The product conforms with the European directive 93/42/CEE dealing with medical devices, and to all the applicable European regulations.

Joycare JC132G - SYMBOL - 3

DISPOSAL

The device (including its removable parts and accessories) must not be disposed of together with municipal waste at the end of its life, but in compliance with European Directive 2002/96/EC. Since

it must be handled separately from household waste, either carry it to a separatelycollected waste disposal centre for electrical and electronic appliances or give it back to the retailer on purchasing a new device with the same purpose. Any infringement will be severely prosecuted. The batteries used in this device must be disposed of in the special bins at the end of their life.

Produced in P.R.C. by FARMIDOC TECHNOLOGY CO., LTD. 6/F G BUILDING, NO 14 LIUXIAN 1ST RD, 71 BLOCK, BAOAN DISTRICT, SHENZHEN, PRC Manufacturer Legal representative in UE : VSIOMED FRANCE 111 RUE DE STALINGRAD, 93100 MONTREUIL FRANCE Distributed with Joycare brand by JOYCARE S.p.A., Via Caduti del Lavoro, 40, 60131, Ancona (Italia)

TECHINAL SPECIFICATIONS

Measuring range 32.0^ 42.9^ (89.6°F - 109,2°F)

Display resolution 0.1^ / 1^

Water proof

Accuracy ± 0.2°F for reading 95.9°F-107,6°F

$$ \pm 0. 1 ^ {\circ} \mathrm {C} \text {f o r r e a d i n g} 3 5. 5 ^ {\circ} \mathrm {C} - 4 2, 0 ^ {\circ} \mathrm {C} $$

Measurement units C^ F^

Auto power off After approximate 8 min

Display LCD

Power supply Not replaceable battery for baby security

Life of battery Approximate 1000 temperatures taking

Operating condition Temp: +10 +35^ (50^ - 104^)

Hum: 15 95% RH

Storage condition Temp: -25 +55^ (-13^ - 131^)

Hum: 15~90%RH

BABY THERMOMÉTRE WATERPROOF JOYCARE JC-132G AFFECTATION ET NORME DE RÉFERENCE

Joycare S.p.A., a company with a sole shareholder, offers a period of 2 year warranty after the date of purchase. The warranty does not cover damage caused by accidental breakage, transportation, incorrect maintenance or cleaning, misuse, tampering or repairs carried out by non authorised third parties. The following is also excluded: damage caused by incorrect product installation, and damage caused by wear and tear, obviously including parts subject to wear and tear. In order to obtain the replacement/repair of products under warranty in cases other

than those mentioned above, but which are instead caused by manufacturing defects, please contact your local importer/distributor. Goods that are not held to be in good condition because of the aforesaid causes must be accompanied by this certificate, duly filled-in, as well as a receipt for the goods (invoices and transport documents) and purchasing documentation.

Please keep the original packaging of the product.

F: CARTE DE GARANTIE

PRODUCT/SERIAL NUMBER/MODEL

PRODUIT / NUMERO DE SERIE/MODELE PRODUCTION/OPERATION/INHERS /MODELS
PRODUXT/SERIENMONNER/MODELLB PRODUTO/NUMERO DE SERIES/MODELO
PRODUCTO/NUMERO DE SERIE/MODELO
IPOJyKT/CEPNEH/MOJEI

PRODUs/SER TERMEXK/SOR


m = 311 ;

INDIRIZZO SNEVER

SENDEREXPERTIDEL

EXPEDITEOR ABSEDER

ABSENDER REMITENTE

REMITENTE

AMPECENT

EXPERTITOR

EXPEDITON CIM

GIM

1

Joycare JC132G - F: CARTE DE GARANTIE - 1

REV.00-JUL2010

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Joycare

Model : JC132G

Category : Thermometer