Product type Submersible pump
Brand Hillvert
Model HT-GP-007
Nominal voltage 230 V ~
Nominal frequency 50 Hz
Nominal power 1100 W
Protection class Class I
Protection rating IPX8
Dimensions (L x W x H) 15 x 15 x 60 cm
Weight 11.3 kg
Maximum pumping height 45 m
Maximum suction height 12 m
Maximum pumping pressure 4.5 bar
Maximum flow rate 100 L/min
Inlet diameter 30.3 mm
Maximum water temperature 35 °C
Maximum particle size 1 mm
Lowest suction level 50 mm
Recommended use Drainage, irrigation, water supply, basements and wells
Integrated protection Automatic standby mode, dry-running protection, leak detection and protection
Maintenance and cleaning Clean with clean water, soft brush and detergent; rinse with clear water

Frequently Asked Questions - HT-GP-007 Hillvert

What is the maximum pumping height of the Hillvert HT-GP-007 pump?
The maximum pumping height is 45 meters. This performance allows water to be drained from deep basements or wells.
What is the maximum flow rate of this submersible pump?
The maximum flow rate is 100 liters per minute. This flow is ideal for rapid drainage of large areas or irrigation.
How do I install the Hillvert HT-GP-007 pump?
Make sure you have an installation space of at least 20x20 cm. Immerse the pump to the specified depth, connect the pressure hose to the connection, then slowly lower the pump using a rope securely attached to the handle. Check that the suction opening is not obstructed.
How do I protect the pump against dry running?
The pump has built-in dry-running protection. If the water level is insufficient, it stops automatically. To restart, simply restore the power supply.
Can this pump be used with hot water?
The maximum water temperature must not exceed 35 °C. It is recommended not to use it with hot water above this limit to avoid damaging the pump.
What liquids are prohibited for this pump?
Do not use the pump with corrosive, flammable, or explosive liquids such as gasoline or oil. Also avoid wastewater or sludge with low mobility.
How do I clean and maintain the Hillvert HT-GP-007 pump?
Unplug the pump before maintenance. Clean the outside with clean water, a soft brush, and detergent if necessary. Briefly run the pump in clean water to rinse the system.
What should I do if the pump does not start?
First check the power supply and the fuses. Make sure the outlet valve is open to release pressure. Remove any blockages in the pipes or the pump. If the problem persists, contact a professional.
What is the IPX8 protection rating?
The IPX8 rating means that the pump is protected against continuous immersion in water, making it suitable for submersible use.
How should I store the pump in winter?
In case of frost risk, remove the pump, clean it thoroughly, and store it in a frost-free place. Make sure it is completely dry before storing it.

User questions about HT-GP-007 Hillvert

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Washing machine in PDF format for free! Find your manual HT-GP-007 - Hillvert and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HT-GP-007 by Hillvert.

USER MANUAL HT-GP-007 Hillvert

This User Manual has been translated for your convenience using machine translation. Reasonable efforts have been made to provide an accurate translation; however, no automated translation is perfect nor is it intended to replace human translators. The official User Manual is the English version. Any discrepancies or differences created in the translation are not binding and have no legal effect for compliance or enforcement purposes. If any questions arise related to the accuracy of the information contained in the User Manual, please refer to the English version of those contents which is the official version.

Technical data

Parameter descriptionParameter value
Product nameSubmersible pump
ModelHT-GP-007
Rated voltage [V~] / frequency [Hz]230/50
Rated power [W]1100
Protection classI
Protection rating IPIPX8
Dimensions [width x depth x height; cm]15 x 15 x 60
Weight [kg]11.3
Max height of pumping [m]45
Max water temp [°C]35
Lowest pump sucking level [mm]50
Max size of particles [mm]1
Max flow rate [L/min]100
Max suction [m]12
Max pumping pressure [bar]4.5
Diameter [mm]Inlet30.3
Outlet

Device description

Line drawing of a small industrial power shaver with coiled cable and plug (no text or symbols)

Preparing for Use and Installation of the Pump

Installation

1. Space Requirement:

- Ensure the installation area has a minimum cross-sectional area of 20x20 cm.

2. Immersion Depth:

- Immerse the equipment to the depth specified in the technical parameters.

3. Suction Opening:

○ Make sure the suction opening is free from any obstructions during installation to maintain equipment stability.

Caution!

• Risk of Equipment Damage:

Do not lift the pump using the cable or pressure hose, as these components are not designed to withstand the tensile force of the pump's weight.

Warning!

• Connection Integrity:

- Ensure that all connection lines and joints are sealed effectively. Leaks can cause frequent operation and reduce the equipment's lifespan.

Connect the Pressure Pipe

- Pipe Connection:

- Screw the pressure pipe securely into the pressure joint. All connections should be sealed with a threaded seal belt.

- Hose Adapter:

- If using a pressure hose, screw the appropriate pressure hose adapter into the pressure joint.

- Hose Attachment:

- Firmly attach the pressure hose to the hose adapter and secure it with a hose clip.

- Occasional Use:

- For occasional use, opt for appropriate plumbing. For fixed positions, rigid pipes with check valves are recommended to prevent fluid backflow when the machine is turned off.

Operation

- Rope Connection:

Use a strong rope to attach to the pump handle. Dip the pump into the liquid at an angle to prevent bubbles from forming under the device, which can interfere with suction.

- Placement:

- Lower the equipment slowly into the liquid container and adjust the position as necessary once submerged. Arrange the pump at the bottom of the container.

• Securing the Rope:

- After lowering, secure the rope's end to allow the pump to be handled safely while hanging.

• Power Connection:

Once the pump is in position, connect it to the main power source to initiate operation.

Device use and functionality

Functions

1. Automatic Standby Mode:

When the outlet valve is closed, the pump enters a standby mode, maintaining pressure in the pipeline. The pump remains stopped but is ready to activate automatically once the outlet valve is opened and pressure is released.

2. Dry Operation Protection:

If the pump is unable to pump water due to insufficient water levels, it enters dry operation protection mode, stopping operation. The pump will only restart when the power is reconnected.

3. Leakage Detection and Protection:

☐ In case of a minor leak in the pipeline that causes the pump to start frequently, the pump enters a protection mode and stops. It will only restart after the power is reconnected.

Operation Checklist

Before turning on the pump, ensure the following conditions are met:

  1. The pipeline includes a metal tube or pressure hose capable of withstanding pressure.
  2. All pipe joints are reliably sealed.
  3. The pump is securely fixed in its position.
  4. The diving depth does not exceed the technical parameter limits.
  5. All electrical connections comply with safety instructions.
  6. The outlet valve is open.

Attention for Rope Handling

  • Do not operate the pump without a pressure hose to prevent twisting around its axis.
  • Regularly check the condition of the rope if continuously used, as it may weaken over time.
  • Attach long, strong ropes to the handle before the first use for balancing when immersed.

Usable Range

The pump is suited for:

  • Basements and shafts to prevent water accumulation.
  • Automated water supply, drainage, and pressurized irrigation.
  • Applications in home, agriculture, gardening, plumbing, and similar contexts.

Cleaning and Maintenance

  • Prohibited Materials: Do not transport corrosive, flammable, or explosive substances, like gasoline or oil. Avoid use with high-temperature liquids, corrosive substances, sewage, or low-mobility mud.
    • Temperature Limit: The liquid's temperature must not exceed 35° C.
  • Cleaning Method: Clean equipment externally with clean water, softer brush and detergent for stubborn grime. Run the pump briefly in clean water to flush the system.

Storage

  • If frost is possible, remove and clean all equipment and store it in a frost-free environment.
  • Warning: Always unplug before maintenance and open the outlet valve to release pipeline pressure.

Additional Warnings and Precautions

  • Ensure the pump is free from dirt residues before reuse to prevent operational issues.
  • Frost can damage the pump and accessories; ensure they are dry and stored correctly in positive temperatures.

Troubleshooting

Error shootingReasonsResponse measures
The device cannot start or stops suddenly1. Unconnected power supply or defective power cord/plug2. Pressure state at rest due to blockages3. Impeller damage causing blockage4. Thermal circuit breaker activated5. Failing internal pressure signal switch1. Check the power supply and inspect safety devices. Consult a professional for electrical inspection if needed.2. Open the outlet valve to relieve pressure. Remove any blockages from pipes or the pump. Allow the pump to cool completely before recharging it with water.3. Have the impeller inspected and serviced by a qualified maintenance professional.4. Ensure ambient and water temperatures are below 35°C. Once temperatures normalize, restore power to the pump.5. Check the signal source through the appropriate traffic maintenance department.
Device frequently starts and stopsLeakage or cloggingMaintain or replace faulty pipes and joints. Cut off the power supply to clean the one-way valve.
Too small flow rate or no water flow1. Insufficient water supply2. Damaged pressure tube3. Dirty water or particulate sewage4. Inlet blockage1. Increase the water supply to ensure it reaches the impeller height.2. Adjust the hose and replace any damaged sections of the pipeline.3. Clean the inlet and replace any damaged components, such as worn impellers.4. Clean the inlet to ensure unimpeded water flow.
Pump cannot shut downDirt in one-way valveHave the one-way valve inspected and cleaned by maintenance professionals.

DISPOSING OF USED DEVICES

Do not dispose of this device in municipal waste systems. Hand it over to an electric and electrical device recycling and collection point. Check the symbol on the product, instruction manual and packaging. The plastics used to construct the device can be recycled in accordance with their markings. By choosing to recycle you are making a significant contribution to the protection of our environment. Contact local authorities for information on your local recycling facility.

Line drawing of a portable industrial water dispenser with coiled cable (no text or symbols)

Priprema za uporabu i ugradnja pumpe

Montaža

1. Potreban prostor:

○ Osigurajte da prostor za ugradnju ima minimalnu površinu poprečnog presjeka od 20x20 cm.

2. Dubina uranjanja:

○ Uronite opremu do dubine navedene u tehničkim parametrima.

3. Usisni otvor:

For the disposal of the device please consider and act according to the national and local rules and regulations.

CONTACT

expondo Polska sp. z o.o. sp. k.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Hillvert

Model : HT-GP-007

Category : Washing machine