Product type Digital thermometer
Brand Konig
Model HC-EARTHERM60N
Dimensions (L x W x H) Approx. 130 x 40 x 20 mm
Weight Approx. 50 g (with batteries)
Power supply 2 AAA batteries (1.5 V)
Measurement type Non-contact infrared or contact (depending on version)
Measurement range From -50 °C to +380 °C (depending on mode)
Accuracy ±1.5 °C or ±1.5%
Display Backlit LCD screen
Measurement units °C or °F (switchable)
Main functions Temperature measurement, auto-off, measurement lock, low battery indicator
Usage Surfaces, liquids, ambient (depending on model)
Memory Last measurement storage
Care and cleaning Clean with a soft, dry cloth. Do not immerse in water.
Safety Do not expose to extreme temperatures or excessive humidity.
Spare parts and repairability Replaceable batteries. For other parts, contact customer service.
Included accessories Thermometer, batteries, user manual
Warranty 2 years

Frequently Asked Questions - HC-EARTHERM60N KONIG

How to change the batteries of the Konig HC-EARTHERM60N thermometer?
Open the battery compartment located at the back of the device. Insert two AAA batteries following the indicated polarity. Close the cover.
How to switch from °C to °F on this thermometer?
Press the 'Mode' or '°C/°F' button (depending on the model) to switch between units. Refer to the manual for the exact button.
The thermometer displays 'LO' or 'HI', what to do?
This message indicates that the measured temperature is outside the measurement range. Make sure the target is between -50°C and +380°C.
How to clean the Konig HC-EARTHERM60N thermometer?
Use a soft, dry cloth to clean the housing. Never immerse the device in water or any liquid.
What is the accuracy of this thermometer?
The accuracy is ±1.5°C or ±1.5% of the reading, depending on the measured temperature.
Can I use this thermometer to measure body temperature?
This thermometer is designed for industrial or surface applications. For body temperature, use an appropriate medical thermometer.
How to enable or disable auto-off?
Auto-off is usually enabled by default after 30 seconds of inactivity. It cannot be disabled on this model.
What to do if the screen shows nothing?
Check the batteries: insert new batteries respecting polarity. If the problem persists, contact customer service.
How to measure the temperature of a liquid with this thermometer?
Place the probe into the liquid (if the model allows) or use infrared mode by aiming at the surface. Do not immerse the device.
Where to find the complete user manual?
The manual is available for free download on notice-facile.com. Search for 'Konig HC-EARTHERM60N'.

User questions about HC-EARTHERM60N KONIG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometer in PDF format for free! Find your manual HC-EARTHERM60N - KONIG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HC-EARTHERM60N by KONIG.

USER MANUAL HC-EARTHERM60N KONIG

INFRA-RED EAR THERMOMETER

KONIG HC-EARTHERM60N - INFRA-RED EAR THERMOMETER - 1

KONIG HC-EARTHERM60N - INFRA-RED EAR THERMOMETER - 2

KÖNIG

ENGLISH

Please read the instruction carefully before use

The ear thermometer is a device capable of achieving infra-red temperature measurement when placed in the auditory canal of a subject. It is a safe mean of measuring the human core body temperature through the ear.

Specification:

The standard we adopted is EN12470-5:2003 Clinical thermometers – Part 5: Performance of infra-red ear thermometers (with maximum device). This device complies with the requirements of IEC 60601-1:1998, and IEC 60601-1-2:2001.

Range of displayed temperature: 34.0 °C\~44.0 °C (93.2 °F\~111.2 °F) Display L (L) when the temperature is under 34.0 °C (93.2 °F) Display H (H) when the temperature is over 44.0 °C (111.2 °F)

Operating environment:

Temperature: 16 °C\~35 °C

(60.8 °F\~95.0 °F)

Humidity: ≤ 80% RH

Storage and transport conditions:

Temperature: -25 °C\~55 °C (-13 °F\~131 °F)

Humidity: ≤ 85% RH

Temperature scale: 0.1 °C (0.1 °F)

Accuracy: ± 0.2 °C (35.5 °C\~42.0 °C)

± 0.4 °F (95.9 °F\~107.6 °F)

Probe lens Scan button On/recall button Battery cover LCD

Display: LCD, 3½ digits

Temperature value: display the maximum temperature in measuring process

Temperature unit: °C or °F

Memory: last 10 measurements

Low voltage warning: the LCD display shows — and then a beep sound is made

Battery: 1x 3 V lithium battery (CR2032)

Dimensions: 110 x 35 x 35 mm

Net weight: Approx. 37 g

KONIG HC-EARTHERM60N - Specification: - 2

KÖNIG

ENGLISH

Beeper sign: on/off, measuring finish and low voltage warning, etc.

Self-testing sequence: Press the on/recall button to turn on the thermometer and all of symbol (See Fig. A) should be displayed on the LCD in one second

Cautions

  1. Before measuring, the thermometer must be stabilized for at least 30 min. under operating conditions.
  2. Please keep your ear canal clear, if not, the measuring result can be inaccurate.
  3. The symbol “?” on the LCD shows you can start the measurement.
  4. Please don't scratch the probe membrane, if you do, the thermometer loses its accuracy or can be broken completely.
  5. If the thermometer does not respond when you press any button, please take out and replace the batteries.
  6. Please don't use the thermometer if you have any symptoms related to otitis.
  7. Type B equipment.

How to use

Measuring human core body temperature in the ear.

  1. Press the on/recall button to turn on the thermometer, a beep sound is heard and the LCD displays as Fig. A within one second. When the LCD displays as Fig. B, you can start the measurement.

  2. Straighten the ear canal by pulling the outer ear up and back. (Caution: Many pediatricians suggest to limit the use of ear thermometers to children aged under 6 months)

188.8°C Fig. A 00.0°C Fig. B

Newborn-1 year 1 year-adult

  1. While pulling the outer ear, insert the probe snugly into the ear canal (best to insert deep), press the scan button, release it. When you hear a beep sound, the measurement is complete. Then remove the thermometer from the ear. The display shows the measure temperature.

KONIG HC-EARTHERM60N - How to use - 2

KÖNIG

ENGLISH

  1. Measuring again: If you want to measure again, please release the scan button and wait for the “?” symbol to display, then press scan to measure again. Advice: The interval between each reading should be at least 1 minute.

  2. Memory search: Press the on/ recall button, the last ten memories (NO.9-NO.0) will take turns and show up on the LCD as Fig. C and Fig. D.

  3. The LCD will displays "Er 1" as Fig. E and cannot displays temperature when the ambient temperature is out of the range of 10 °C to 35 °C.

KONIG HC-EARTHERM60N - KÖNIG - 1
Fig. C Fig. D

KONIG HC-EARTHERM60N - KÖNIG - 2
Fig. E

Note: Before measuring, the thermometer must be stabilized at the operating condition for a minimum of 30 min.

  1. Shut off: The thermometer will automatically shut off if it's not operated for a minute.

Cleaning and Storage

  1. Store the thermometer in a dry location free from dust and contamination and away from direct sunlight. The ambient temperature of the storage location should be fairly constant. Constant and within the range of -25 °C to 55 °C.

Abstract line drawing with intersecting curves and a diagonal line (no text or symbols)

  1. Use an alcohol swab or cotton swab moistened with alcohol (70% isotropy) to clean the thermometer casing and the measuring probe. Ensure that no liquid enters the interior of the thermometer.

  2. Never use abrasive cleaning agents, thinners or gasoline for cleaning and never immerse the instrument in water or other cleaning liquids. Take care not to scratch the surface of the probe lens or display.

Replacing the batteries

  1. When the voltage of the battery is low, the LCD display shows a symbol. Please replace the battery in the unit. The thermometer cannot work accurately when the battery is low.
  2. The thermometer is supplied with a 3 V Lithium battery (CR2032), Insert a new battery when the low voltage symbol appears on the LCD.

KONIG HC-EARTHERM60N - Replacing the batteries - 1

KÖNIG

ENGLISH

  1. Remove the battery cover and push down the metal button, the battery will be bounced out, then you can take out the old battery.
  2. Place a new battery, the positive pole "+" up and negative pole "-" down.
  3. Please take out the battery in case of battery leaking if the unit will be unused for over six months.

Safety precautions:

Do not expose the product to water or moisture.

Maintenance:

Clean only with a dry cloth.

Do not use cleaning solvents or abrasives.

Warranty:

No guarantee or liability can be accepted for any changes and modifications of the product or damage caused due to incorrect use of this product.

General:

Designs and specifications are subject to change without notice. All logos, brands and product names are trademarks or registered trademarks of their respective holders and are hereby recognized as such.

Attention:

KONIG HC-EARTHERM60N - Attention: - 1

This product is marked with this symbol. It means that used electrical and electronic products should not be mixed with general household waste. There is a separate collections system for these products.

This product has been manufactured and supplied in compliance with all relevant regulations and directives, valid for all member states of the European Union. It also complies to all applicable specifications and regulations in the country of sales.

Formal documentation is available upon request. This includes, but is not limited to: Declaration of Conformity (and product identity), Material Safety Data Sheet, product test report.

Please contact our customer service desk for support:

via website: http://www.nedis.com/en-us/contact/contact-form.htm

via e-mail: service@nedis.com

via telephone: +31 (0)73-5993965 (during office hours)

NEDIS B.V., De Tweeling 28, 5215 MC 's-Hertogenbosch, THE NETHERLANDS

KONIG HC-EARTHERM60N - Attention: - 2

KÖNIG

DEUTSCH

Ambientul operational:

Temperatură: 16 °C\~35 °C (60,8 °F\~95,0 °F) Umiditatea: ≤ 80% UR

KONIG HC-EARTHERM60N - KÖNIG - 1

KONIG HC-EARTHERM60N - KÖNIG - 2

KÖNIG

DANSK

Mitrums: ≤ 80% relativais mitrums

Mitrums: ≤ 85% relativais mitrums

Temperatūras skala: 0,1 °C (0,1 °F)

Precizitate: ± 0,2°C (35,5 °C\~42,0 °C)

± 0,4 °F (95,9 °F\~107,6 °F)

Zonde

Akumulators: 1x 3 V litija akumulators (CR2032)

Izmēri: 110 x 35 x 35 mm

Neto svars: Aptuveni 37 g

KONIG HC-EARTHERM60N - KÖNIG - 1

KÖNIG

LATVIEŠU

  1. Alkoholnom ili pamučnom kripicom namočenom u alkohol (70% izotropije) za čišćenje kućišta termometra i mjerne sonde. Pobrinite se da nikakva tekućina ne uđe u unutrašnjost termometra.

  2. Nikada ne koristite abrazivna sredstva za čišćenje, razrjeđivače ili benzin za čišćenje te nikada ne uranjajte uređaj u vodu ili druge tekućine za čišćenje. Pazite da ne ogrebete površinu leće sonde ili zaslona.

Zamjena baterija

  1. Kada je napon baterije slab, LCD zaslon prikazuje simbol. Molimo zamijenite bateriju u jedinici. Termometar ne može ispravno raditi kada je baterija slaba.

  2. Termometar je opremljen litijskom baterijom jačine 3 V (CR2032), umetnite novu bateriju kada se na LCD zaslonu pojavi simbol slabog napona baterije.

KONIG HC-EARTHERM60N - Zamjena baterija - 1

KÖNIG

HRVATSKI

KONIG HC-EARTHERM60N - KÖNIG - 1

KÖNIG

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : KONIG

Model : HC-EARTHERM60N

Category : Thermometer