BLUEPALM BPPAC12000FW - Air Conditioning

BPPAC12000FW - Air Conditioning BLUEPALM - Free user manual and instructions

Find the device manual for free BPPAC12000FW BLUEPALM in PDF.

📄 179 pages English EN Download 💬 AI Question
Notice BLUEPALM BPPAC12000FW - page 154
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about BPPAC12000FW BLUEPALM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Conditioning in PDF format for free! Find your manual BPPAC12000FW - BLUEPALM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BPPAC12000FW by BLUEPALM.

USER MANUAL BPPAC12000FW BLUEPALM

natural_image Front view of a white industrial air conditioner unit with control panel and digital display (no visible text or symbols)

HERZLICHEN GLÜCKWUNSCH!

VIELEN DANK, DASS SIE SICH FÜR EIN PRODUKT VON BLUEPALM ENTSCHIEDEN HABEN.

text_image QR code image containing encoded data, no visible human-readable text
text_image Warning symbols including no hand, flame, open book, and warning triangle

https://www.schuss-home.at/downloads

text_image Diagram of a portable air conditioner unit with numbered parts labeled 1 to 5

BLUEPALM BPPAC12000FW - HERZLICHEN GLÜCKWUNSCH! - 1

natural_image Technical line drawing of a coiled spring or hose component with no visible text or symbols

BLUEPALM BPPAC12000FW - HERZLICHEN GLÜCKWUNSCH! - 2

BLUEPALM BPPAC12000FW - HERZLICHEN GLÜCKWUNSCH! - 3

text_image Technical diagram of a portable air conditioner unit with numbered labels pointing to components

BLUEPALM BPPAC12000FW - HERZLICHEN GLÜCKWUNSCH! - 4

text_image Diagram of a mobile device control panel with labeled icons and labels 1 through 7

BLUEPALM

Installation

natural_image Technical line drawing of a mechanical device with coiled tubing and housing (no text or symbols)
natural_image Line drawings of two different air purifiers with ventilation ducts and a window frame (no text or symbols)

Falsche Installation

natural_image Technical line drawing of a mechanical device with a cross-shaped component (no text or symbols)

Bemerkung:

natural_image Line drawing of a portable air conditioner unit with a cup beside it (no text or symbols)

BLUEPALM

gestartet).

natural_image Line drawing of a portable industrial fan with ventilation grille and control panel (no text or symbols)
natural_image Line drawing of a vintage portable air conditioner unit with fan and control panel (no text or symbols)

BLUEPALM BPPAC12000FW - BLUEPALM - 1

natural_image Diagram of a portable air conditioner unit with cooling fan and heating panel (no text or symbols)

SAISONALE REINIGUNG

text_image QR code with a blue home icon in the center, likely linking to a digital service or application.

Scan QR code

Registrierung

text_image 09:17 Add Device Turn on Bluetooth Bluetooth makes your device more disassembled. Add Device Select 2.4 GHz Wi-Fi Network and enter password. If your WIFI 5GHz, please set it to be 2.4GHz. Common router setting method X Wi-Fi - 5GHz ✓ Wi-Fi - 2.4GHz XK001 Select Wi-Fi 123456789 Add Manually Electrical Air Conditioning Lighting Sensors Air Condour (BLDefA) Air Condour (BL-Fl) Air Condour (Zdsm) Large Home Appliances Next 09:17 Reset the device Press and hold the RESET button for 5 seconds will the indicator white (subject to the user morning) Select the status of the indicator light or hear the beep: Think Slowy Think Quickly 09:21 Connect your mobile phone to the device's hotspot Connect your phone to the hotspot shows below: WLAN? ✓ SmartLife-XXXX ✓ SL-XXXX “请勿” Wants to Join WLAN Network "SmartLife-E760"? Cancel Join Go to Connect 10:12 Add Device (see this) added weekly by: Portascift Air Conditioner... Add successful Done
text_image My Home Cable Notification All Devices Shortcut center Wireless Settings Browse Ultra Sensor Magic Black Mode Scan Kiachi 12 Pro Flareght Bluetooth Speech ID Unknown Mode Data network All Devices Devices to be added: 1 Air Conditioner Add Enter Wi-Fi Information Choose Wi-Fi and enter password Xiaomi 12 Pro 1234567890 Next

BLUEPALM BPPAC12000FW - Registrierung - 1

text_image Add Device 1 daily being added Air Conditioner Being added Add Device 1 devices asked successfully Air Conditioner Added successfully Done 14:20 my home 30°C Good Good 51.0% Outside PM2.5 Outdoor in the Outside Humidity Calls Notification All Devices Air Conditioner

BLUEPALM BPPAC12000FW - Registrierung - 2
works with the Google Assistant

natural_image Front view of a white outdoor air conditioner unit with control panel and digital display (no visible text or symbols)

FÉLICITATIONS! MERCI D'AVOIR CHOISI UN PRODUIT BLUEPALM.

BLUEPALM BPPAC12000FW - Registrierung - 3

text_image QR code image containing encoded data, no visible human-readable text

VEUILLEZ LIRE ATTENTIVEMENT LE MODE D'EMPLOI AVANT DE PROCÉDER AU MONTAGE, À L'INSTALLATION, À L'UTILISATION OU À L'ENTRETIEN. PROTÉGEZ-VOUS ET PROTÉGEZ LES AUTRES EN RESPECTANT LES CONSIGNES DE SÉCURITÉ. LE NON-RESPECT DES INSTRUCTIONS POURRAIT ENTRAÎNER DES DOMMAGES CORPORELS ET/OU MATÉRIELS ET/OU LA PERTE DU DROIT À LA GARANTIE !

INFORMATIONS IMPORTANTES SUR LA SÉCURITÉ, ET À L'ÉLECTRICITÉ RACCORDEMENT.

BLUEPALM BPPAC12000FW - Registrierung - 4

text_image Warning symbols including no hand, flame, open book, and warning triangle

DÉCLARATION DE CONFORMITÉ

https://www.schuss-home.at/downloads

text_image Technical diagram of a portable air conditioner unit with numbered parts labeled 1 to 5

BLUEPALM BPPAC12000FW - DÉCLARATION DE CONFORMITÉ - 1

natural_image Diagram of a coiled spring with labeled component (no text or symbols present)

BLUEPALM BPPAC12000FW - DÉCLARATION DE CONFORMITÉ - 2

BLUEPALM BPPAC12000FW - DÉCLARATION DE CONFORMITÉ - 3

text_image Technical diagram of a portable air conditioner unit with numbered labels pointing to components

BLUEPALM BPPAC12000FW - DÉCLARATION DE CONFORMITÉ - 4

PANNEAU DE COMMANDE ET TÉLÉCOMMANDE
BLUEPALM BPPAC12000FW - DÉCLARATION DE CONFORMITÉ - 5

flowchart
graph TD
    A["TIMER"] --> B["5"]
    C["FAN"] --> D["4"]
    E["▲"] --> F["3"]
    G["▼"] --> H["2"]
    I["MODE"] --> J["1"]

BLUEPALM

natural_image Technical line drawing of a mechanical device with coiled tubing and a housing (no text or symbols)
natural_image Technical line drawing of two different air conditioning machines with ventilation ducts and control panel (no text or symbols)
natural_image Technical line drawing of a mechanical device with a cross-shaped component (no text or symbols)

Remarque:

natural_image Line drawing of a portable air purifier with fan and bucket (no text or symbols)

BLUEPALM

Remarque :

natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

NETTOYAGE ET ENTRETIEN

natural_image Line drawing of a portable electric fan with cooling fins and a handle, no text or symbols present

BLUEPALM BPPAC12000FW - NETTOYAGE ET ENTRETIEN - 1

natural_image Line drawing of a portable air conditioner unit with cooling fan and ventilation slots (no text or symbols)
text_image QR code with a blue house icon in the center, likely linking to a digital service or application.

Scan QR code

Inscription

text_image 09:17 Add Device Turn on Bluetooth Bluetooth makes your device more accessible. All Devices Edit Add Manually Electrical Air Conditioning Lighting Sensors Air Control (INTe-FF) Air Control (RF-YY) Air Control (Zidem) Large Home Appliances Select 2.4 GHz Wi-Fi Network and enter password. If your WiFi is 5GHz, please set it to be 2.4GHz. Common router setting method X Wi-Fi - 5GHz ✓ Wi-Fi - 2.4GHz XK001 Select Wi-Fi 1234E6789 Next 09:17 Reset the device Press and hold the RESET button for 5 seconds will the indicator while (subject to the user memory). Select the status of the indicator light or hear the beep: Blink Slowy Blink Quickly 09:21 Connect your mobile phone to the device's hotspot Connect your phone to the hotspot when below: WLAN ✓ SmartLife-XXXX ✓ SL-XXXX "便利" Wants to Join WLAN Network "SmartLife-E760"? Cancel Join Go to Connect 10:12 Add Device I recommend(s) added successfully. Portascift Air Conditioner(L... Ask successfuls Done
text_image My Home Daily Modification All Devices Outdoor center Wireless Cablegate Bluetooth One Game Music One Mode Smart TV App Bluetooth Switch Us Windows Mode Autophones Daily Modification All Devices Devices to be added: 1 Air Conditioner Add Enter Wi-Fi Information Choose Wi-Fi and enter password) Xiaomi 12 Pro 1234567890 Add

BLUEPALM BPPAC12000FW - Inscription - 1

text_image Add Device Air Conditioner Doing selected Done Add Device Air Conditioner Added successfully Done 14:20 my home 30°C Good Good SLR Outdoor PMI 5 Outdoor air to the Outdoor normal Caily Modification All Devices Air Conditioner

BLUEPALM BPPAC12000FW - Inscription - 2
works with the Google Assistant

natural_image Front view of a white BLUOIC air conditioner unit with control panel and digital display (no visible text or symbols on main body)

CONGRATULAZIONI! GRAZIE PER AVER SCELTO UN PRODOTTO BLUEPALM.

BLUEPALM BPPAC12000FW - Inscription - 3

text_image QR code image containing encoded data, no visible human-readable text

LEGGERE ATTENTAMENTE LE ISTRUZIONI PER L'USO PRIMA DI INIZIARE IL MONTAGGIO, L'INSTALLAZIONE, IL FUNZIONAMENTO O LA MANUTENZIONE. PROTEGGERE SE STESSI E GLI ALTRI SEGUENDO LE ISTRUZIONI DI SICUREZZA. LA MANCATA OSSERVANZA DELLE ISTRUZIONI PUÒ CAUSARE LESIONI PERSONALI E/O DANNI MATERIALI E/O LA PERDITA DELLA COPERTURA DELLA GARANZIA!

IMPORTANTI INFORMAZIONI SULLA SICUREZZA, E ALL'IMPIANTO ELETTRICO COLLEGAMENTO.

BLUEPALM BPPAC12000FW - Inscription - 4

text_image Warning symbols including no hand, flame, open book, and warning triangle

https://www.schuss-home.at/downloads

text_image Diagram of a portable air conditioner unit with numbered parts labeled 1 to 5

BLUEPALM BPPAC12000FW - Inscription - 5

natural_image Diagram of a coiled spring with labeled components (no text or symbols present)

BLUEPALM BPPAC12000FW - Inscription - 6

BLUEPALM BPPAC12000FW - Inscription - 7

text_image Technical diagram of a portable air conditioner unit with numbered labels pointing to components

BLUEPALM BPPAC12000FW - Inscription - 8

PANNELLO DI CONTROLLO E TELECOMANDO
BLUEPALM BPPAC12000FW - Inscription - 9

flowchart
graph TD
    A["TIMER"] --> B["1"]
    C["FAN"] --> D["4"]
    E["△"] --> F["3"]
    G["▽"] --> H["2"]
    I["MODE"] --> J["1"]
    K["POWER"] --> L["1"]
    B --> F
    D --> F
    H --> F
    J --> F

BLUEPALM

natural_image Technical line drawing of a mechanical device with coiled tubing and ventilation grilles (no text or symbols)
natural_image Technical line drawings of two different air conditioning machines with ventilation ducts and control panel (no text or symbols)
natural_image Technical line drawing of a mechanical device with a cross-shaped component (no text or symbols)

Osservazione:

natural_image Line drawing of a portable air conditioner unit with a cup and fan (no text or symbols)

BLUEPALM

natural_image Line drawing of a portable air conditioner unit with fan and control panel (no text or symbols)
natural_image Line drawing of a portable electric fan with ventilation grille and cooling fins (no text or symbols)

BLUEPALM BPPAC12000FW - BLUEPALM - 1

natural_image Line drawing of a portable air conditioner unit with cooling fan and heating panel (no text or symbols)

PULIZIA STAGIONALE

text_image QR code with a blue house icon in the center, likely linking to a digital service or application.

Scan QR code

Registrazione

text_image 09:17 Add Device Turn on Bluetooth Bluetooth makes your device more accessible. All Devices Edit Add Manually Electrical Air Conditioning Lighting Sensors Air Control (INTe-FF) Air Control (AC-YY) Air Control (Zidem) Large Home Appliances Select 2.4 GHz Wi-Fi Network and enter password. If your WiFi is 5GHz, please set it to be 2.4GHz. Common router setting method X Wi-Fi - 5GHz ✓ Wi-Fi - 2.4GHz XK001 Select Wi-Fi 1234E6789 Next 09:17 Reset the device Press and hold the RESET button for 5 seconds will the indicator while (subject to the user memory). Select the status of the indicator light or hear the beep: Blink Slowy Blink Quickly 09:21 Connect your mobile phone to the device's hotspot Connect your phone to the hotspot when below: WLAN ✓ SmartLife-XXXX ✓ SL-XXXX "便利" Wants to Join WLAN Network "SmartLife-E760"? Cancel Join Go to Connect 10:12 Add Device I recommend(s) added successfully. Portascift Air Conditioner(L... Ask successfuls Done
text_image My Home Daily Modification All Devices Outdoor center Wireless Cablegate Bluetooth One Game Music One Mode Smart TV App Bluetooth Switch Us Windows Mode Autophones Daily Modification All Devices Devices to be added: 1 Air Conditioner Add Enter Wi-Fi Information Choose Wi-Fi and enter password) Xiaomi 12 Pro 1234567890 Add

BLUEPALM BPPAC12000FW - Registrazione - 1

text_image Add Device Air Conditioner Doing selected Done Add Device Air Conditioner Added successfully Done 14:20 my home 30°C Good Good SLR Outdoor PMI 5 Outdoor air to the Outdoor normal Caily Modification All Devices Air Conditioner

BLUEPALM BPPAC12000FW - Registrazione - 2
works with the Google Assistant

natural_image Front view of a white blue and white air conditioner unit with control panel and digital display (no visible text or symbols)

GEFELICITEERD! BEDANKT OM VOOR EEN BLUEPALM PRODUCT TE KIEZEN.

BLUEPALM BPPAC12000FW - Registrazione - 3

text_image QR code image containing encoded data, no visible human-readable text

LEES DE BEDIENINGSINSTRUCTIES ZORGVULDIG DOOR VOORDAT U BEGINT MET DE MONTAGE, INSTALLATIE, BEDIENING OF HET ONDERHOUD. BESCHERM UZELF EN ANDEREN DOOR DE VEILIGHEIDSINSTRUCTIES OP TE VOLGEN. HET NIET OPVOLGEN VAN DE INSTRUCTIES KAN LEIDEN TOT PERSOONLIJK LETSEL EN/OF MATERIËLE SCHADE EN/OF VERLIES VAN DE GARANTIEDEKKING!

BELANGRIJKE

VEILIGHEIDSINFORMATIE, LOCATIE EN NAAR DE ELEKTRISCHE VERBINDING.

BLUEPALM BPPAC12000FW - Registrazione - 4

BLUEPALM BPPAC12000FW - Registrazione - 5

BLUEPALM BPPAC12000FW - Registrazione - 6

BLUEPALM BPPAC12000FW - Registrazione - 7

BLUEPALM BPPAC12000FW - Registrazione - 8

text_image Technical diagram of a portable air conditioner unit with numbered parts labeled 1 to 5

BLUEPALM BPPAC12000FW - Registrazione - 9

natural_image Diagram of a coiled spring with labeled component (no text or symbols present)

BLUEPALM BPPAC12000FW - Registrazione - 10

BLUEPALM BPPAC12000FW - Registrazione - 11

text_image Technical diagram of a portable air conditioner unit with numbered labels pointing to components

BLUEPALM BPPAC12000FW - Registrazione - 12

BEDIENINGSPANEEL EN AFSTANDSBEDIENING
BLUEPALM BPPAC12000FW - Registrazione - 13

flowchart
graph TD
    A["TIMER"] --> B["1"]
    C["FAN"] --> D["4"]
    E["▲"] --> F["3"]
    G["▼"] --> H["2"]
    I["MODE"] --> J["1"]
    K["POWER"] --> L["1"]

BLUEPALM

1. Aan- en uitknop

PLAATSING EN INSTALLATIE

Line-up

natural_image Technical line drawing of a mechanical device with coiled tubing and housing (no text or symbols)
natural_image Technical line drawing of two air conditioning machines with ventilation ducts and control panel (no text or symbols)
natural_image Technical line drawing of a mechanical device with a cross-shaped component (no text or symbols)

Opmerking:

natural_image Line drawing of a portable electric heater with fan and cup (no text or symbols)

BLUEPALM

natural_image Line drawing of a portable electric fan with ventilation grille and control panel (no text or symbols)

REINIGING EN ONDERHOUD

natural_image Line drawing of a portable electric heater with fan and cooling fins (no text or symbols)

BLUEPALM BPPAC12000FW - REINIGING EN ONDERHOUD - 1

natural_image Diagram of a portable air conditioner unit with cooling fan and heating panel, showing internal structure and airflow direction (no text or labels)

SEIZOENSGEBONDEN SCHOONMAAK

text_image QR code with a blue house icon in the center, likely linking to a digital service or application.

Scan QR code

Registratie

text_image 09:17 我的家... Learn abeu DIT Homep 2011 02:00:48 Add Device Create Scene Add Quick Toggle Card Scan Take way All Devices Edit Add Device Turn on Bluetooth? Bluetooth makes your device more disassembled. Add Manually Electrical Air Conditioning Lighting Sensors Air Cool out (BLDefA) Discharge (AC-5) Cool out (Zdsm) Large Home Appliances Select 2.4 GHz Wi-Fi Network and enter password. If your WLAN is 5GHz, please set it to be 2.4GHz. Common router setting method X Wi-Fi - 5GHz ✓ Wi-Fi - 2.4GHz XK001 Select Wi-Fi 123456789 Next 09:17 Reset the device Press and hold the RESET button for 5 seconds will the indicator white (subject to the user morning) Select the status of the indicator light or hear the beep: Think Slowy Think Quickly 09:21 Connect your mobile phone to the device's hotspot Connect your phone to the hotspot shows below: WLAN ✓ SmartLife-XXXX ✓ SL-XXXX “请勿”Wants to Join WLAN Network "SmartLife-E760"? Cancel Join Go to Connect 10:12 Add Device Lemon(s) added network only Portascift Air Conditioner(L)... Add successful Done
text_image My Home Daily Modification All Devices Outdoor center Wireless Cablegate Bluetooth One Game Music One Mode Smart TV App Bluetooth Switch-U Windows Mac Autophones Daily Modification All Devices Devices to be added: 1 Air Conditioner Add Enter Wi-Fi Information Choose Wi-Fi and enter password) Xiaomi 12 Pro 1234567890 Add

BLUEPALM BPPAC12000FW - Registratie - 1

text_image Add Device Air Conditioner Doing selected Done Add Device Air Conditioner Added successfully Done 14:20 my home 30°C Good Good SLR Outdoor PMI 5 Outdoor air to the Outdoor normal Caily Modification All Devices Air Conditioner
text_image WORKS WITH amazon alexa works with the Google Assistant
Technische gegevens WiFi
Draadloze technologie:Wifi (WLAN)
Radiofrequentie2412 MHz-2472 MHz
BLE-frequentie2402 MHz-2480 MHz
Modulatietype802.11b: DSSS802.11g: OFDM802.11n (20 MHz): OFDM
Vaste frequentie-softwareSecureCRT.exe
Antenneversterking2,5 dBi
AntennetypePCB
Zendvermogen:520dBm

BLUEPALM

FOUT

Foutdetectie

natural_image White industrial air conditioner unit with digital display and control buttons (no visible text or symbols on main body)

GRATULERAR! TACK FÖR ATT DU VALDE EN PRODUKT FRÅN BLUEPALM.

BLUEPALM BPPAC12000FW - FOUT - 1

text_image QR code image containing encoded data, no visible human-readable text

LÄS BRUKSANVISNINGEN NOGGRANT INNAN DU PÅBÖRJAR MONTERING, INSTALLATION, DRIFT ELLER UNDERHÅLL. SKYDDA DIG SJÄLV OCH ANDRA GENOM ATT FÖLJA SÄKERHETSANVISNINGARNA. UNDERLÄTENHET ATT FÖLJA ANVISNINGARNA KAN LEDA TILL PERSONSKADA OCH/ELLER EGENDOMSSKADA OCH/ELLER GÖRA GARANTIN OGILTIG!

VIKTIG SÄKERHETSINFORMATION, PLATS OCH TILL DEN ELEKTRISKA ANSLUTNING.

BLUEPALM BPPAC12000FW - FOUT - 2

text_image Warning symbols including no hand, flame, open book, and warning triangle

https://www.schuss-home.at/downloads

text_image Technical diagram of a portable air conditioner unit with numbered parts labeled 1 to 5

BLUEPALM BPPAC12000FW - FOUT - 3

natural_image Diagram of a coiled spring with labeled component (no text or symbols present)

BLUEPALM BPPAC12000FW - FOUT - 4

BLUEPALM BPPAC12000FW - FOUT - 5

text_image Technical diagram of a portable air conditioner unit with numbered labels pointing to components

BLUEPALM BPPAC12000FW - FOUT - 6

KONTROLLPANEL OCH FJÄRRKONTROLL
BLUEPALM BPPAC12000FW - FOUT - 7

flowchart
graph TD
    A["TIMER"] --> B["1"]
    C["FAN"] --> D["4"]
    E["▲"] --> F["3"]
    G["▼"] --> H["2"]
    I["MODE"] --> J["1"]
    K["POWER"] --> L["1"]

BLUEPALM

text_image Diagram of a refrigerator control panel with labeled icons and temperature settings

UPPSTÄLLNING OCH INSTALLATION

Installation

natural_image Technical line drawing of a mechanical device with coiled tubing and housing (no text or symbols)
natural_image Technical line drawing of two air conditioning machines with ventilation ducts and control panel (no text or symbols)

Felaktig installation

natural_image Technical line drawing of a mechanical device with a cross-shaped component (no text or symbols)

Anmärkning:

natural_image Line drawing of a portable air conditioner unit with a cup beside it (no text or symbols)

Obs!

natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

RENGÖRING OCH UNDERHÅLL

natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

BLUEPALM BPPAC12000FW - RENGÖRING OCH UNDERHÅLL - 1

natural_image Line drawing of a portable air conditioner unit with cooling fan and heating element (no text or symbols)

SÄSONGSBETONAD STÄDNING

text_image QR code with a blue house icon in the center, likely linking to a digital service or website.

Scan QR code

BLUEPALM

Registrering

text_image 09:17 我的家... Learn about DIY homep Add Device Create Scene Add Quick Toggle Card Scan All Devices Edit 09:17 Add Device Turn on Bluetooth Bluetooth makes your device more discoverable. 09:17 Select 2.4 GHz Wi-Fi Network and enter password. If your Wi-Fi is 5GHz, please set it to be 2.4GHz. Common router setting method × Wi-Fi - 6Ghz ✓ Wi-Fi - 2.4Ghz XK001 Select Wi-Fi 123456789 Add Manually Electrical Air Conditioning Lighting Sensor: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Condition: Air Directional Large Home Appliances Next

BLUEPALM

BLUEPALM BPPAC12000FW - BLUEPALM - 1

text_image 09:17 Reset the device Press and hold the RESET button for 5 seconds and the indicator while (subject to the user manual) Select the status of the indicator light or hear the beep: Blink Slowly Blink Quickly 09:21 Connect your mobile phone to the device's hotspot Connect your phone to the hotspot shown below: WLAN ✓ SmartLife-XXXX ✓ SL-XXXX "请将" Wants to Join WLAN Network "SmartLift-E758"? Cancel Join Go to Connect 10:12 Add Device Electricity added successfully Portasoft Air Conditioner... Made successfully Done
text_image My Home Cable Notification All Devices District center Wireless Settings Browser Ultra Store Mobile Black Mode Scan Kiaomi 12 Pro Bluetooth SpeedUp Bluetooth Mode Data Network my Home Cable Notification All Devices Devices to be added: 1 Air Conditioner Add Enter Wi-Fi Information Choose Wi-Fi and enter password Xiaomi 12 Pro 1234567890 Next

BLUEPALM

BLUEPALM BPPAC12000FW - BLUEPALM - 1

text_image Add Device Air Conditioner Air Conditioner Air Conditioner Air Conditioner Air Conditioner Air Conditioner Done 14:10:27 € 5.37 € 6% 14:10:27 € 5.37 € 6% 14:20:27 € 5.37 € 6% My North Cash increase 30°C Good Good $1.0% Options Hold to Check up for next Customer Closing Cash Notification All Devices Air Conditioner

WORKS WITH amazon alexa

BLUEPALM BPPAC12000FW - BLUEPALM - 2

works with the Google Assistant

Tekniska data WiFi
Trådlös teknik:Wifi (WLAN)
Radiofrekvens2412 MHz–2472 MHz
BLE-driftfrekvens2402 MHz–2480 MHz
Modulationstyp802.11b: DSSS802.11g: OFDM802.11n (20 MHz): OFDM
FastfrekvensprogramvaraSecureCRT.exe
Antennförstärkning2,5 dBi
AntennPCB
Överföringseffekt:520 dBm

FEL

Detektering av fel

natural_image Front view of a white industrial air conditioner unit with control panel and digital display (no visible text or symbols)

GRATULUJEME! DĚKUJEME, ŽE JSTE SI VYBRALI PRODUKT BLUEPALM.

BLUEPALM BPPAC12000FW - FEL - 1

text_image QR code image containing encoded data, no visible human-readable text

PŘED ZAHÁJENÍM MONTÁŽE, INSTALACE, PROVOZU NEBO ÚDRŽBY SI POZORNĚ PŘEČTĚTE NÁVOD K OBSLUZE. DODRŽOVÁNÍM BEZPEČNOSTNÍCH POKYNŮ CHRAŇTE SEBE I OSTATNÍ. NEDODRŽENÍ POKYNŮ MŮŽE MÍT ZA NÁSLEDEK ZRANĚNÍ OSOB A/NEBO POŠKOZENÍ MAJETKU A/NEBO ZTRÁTU ZÁRUKY!

DŮLEŽITÉ BEZPEČNOSTNÍ INFORMACE, UMÍSTĚNÍ A K ELEKTRICKÉMU SPOJENÍ.

BLUEPALM BPPAC12000FW - FEL - 2

text_image Warning symbols including no hand, flame, open book, and warning signs

https://www.schuss-home.at/downloads

text_image Diagram of a portable air conditioner unit with numbered parts labeled 1 to 5

BLUEPALM BPPAC12000FW - FEL - 3

natural_image Diagram of a coiled spring with labeled components (no text or symbols present)

BLUEPALM BPPAC12000FW - FEL - 4

BLUEPALM BPPAC12000FW - FEL - 5

text_image Technical diagram of a portable air conditioner unit with numbered parts labeled 7, 8, 9, and 10

BLUEPALM BPPAC12000FW - FEL - 6

OVLÁDACÍ PANEL A DÁLKOVÉ OVLÁDÁNÍ

BLUEPALM BPPAC12000FW - OVLÁDACÍ PANEL A DÁLKOVÉ OVLÁDÁNÍ - 1

flowchart
graph TD
    A["TIMER"] --> B["1"]
    C["FAN"] --> D["4"]
    E["△"] --> F["3"]
    G["▽"] --> H["2"]
    I["MODE"] --> J["1"]
    K["POWER"] --> L["1"]
    B --> F
    D --> F
    H --> F
    J --> F

BLUEPALM

natural_image Technical line drawing of a mechanical device with coiled tubing and ventilation grilles (no text or symbols)
natural_image Technical line drawings of two different air conditioning machines with ventilation ducts and control panel (no text or symbols)

Nesprávná instalace

natural_image Technical line drawing of a mechanical device with a cross-shaped component (no text or symbols)

Poznámka:

natural_image Line drawing of a portable electric heater with fan and cup (no text or symbols)

BLUEPALM

Nápověda:

natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

ČIŠTĚNÍ A ÚDRŽBA

natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

BLUEPALM BPPAC12000FW - ČIŠTĚNÍ A ÚDRŽBA - 1

natural_image Line drawing of a portable air conditioner unit with cooling fan and heating element (no text or symbols)

SEZÓNNÍ ÚKLID

text_image QR code with a blue house icon in the center, likely linking to a digital service or application.

Scan QR code

Registrace

text_image 09:17 Add Device Turn on Bluetooth Bluetooth makes your device more accessible. All Devices Edit Add Manually Electrical Air Conditioning Lighting Sensors Air Control (INTe-FF) Air Control (AC-YY) Air Control (Zidem) Large Home Appliances Select 2.4 GHz Wi-Fi Network and enter password. If your WiFi is 5GHz, please set it to be 2.4GHz. Common router setting method X Wi-Fi - 5GHz ✓ Wi-Fi - 2.4GHz XK001 Select Wi-Fi 1234E6789 Next 09:17 Reset the device Press and hold the RESET button for 5 seconds will the indicator while (subject to the user memory). Select the status of the indicator light or hear the beep: Blink Slowy Blink Quickly 09:21 Connect your mobile phone to the device's hotspot Connect your phone to the hotspot when below: WLAN ✓ SmartLife-XXXX ✓ SL-XXXX "便利" Wants to Join WLAN Network "SmartLife-E760"? Cancel Join Go to Connect 10:12 Add Device I recommend(s) added successfully. Portascift Air Conditioner(L... Add successfuls Done
text_image Add Device Air Conditioner Being added Add Device Air Conditioner Added successfully Done 30°C Good Good 51.6% Speed PRU 2.0 Speed PRU 2.0 Speed PRU 2.0 Daily Modification All Devices Air Conditioner

Aplikace funguje také s Amazon Alexa a Google Assistant.
BLUEPALM BPPAC12000FW - Registrace - 1
WORKS WITH amazon alexa

BLUEPALM BPPAC12000FW - Registrace - 2
works with the Google Assistant

natural_image Front view of a white industrial air conditioner unit with control panel and digital display (no visible text or symbols)

GRATULUJEME! ĎAKUJEME, ŽE STE SI VYBRALI VÝROBOK BLUEPALM.

BLUEPALM BPPAC12000FW - Registrace - 3

text_image QR code image containing encoded data, no visible human-readable text

PRED ZAČATÍM MONTÁŽE, INŠTALÁCIE, PREVÁDZKY ALEBO ÚDRŽBY SI POZORNE PREČÍTAJTE NÁVOD NA OBSLUHU. DODRŽIAVANÍM BEZPEČNOSTNÝCH POKYNOV CHRÁŇTE SEBA AJ OSTATNÝCH. NEDODRŽANIE POKYNOV MÔŽE MAŤ ZA NÁSLEDOK ZRANENIE OSÔB A/ALEBO POŠKODENIE MAJETKU A/ALEBO STRATU ZÁRUČNÉHO KRYTIA!

DÔLEŽITÉ BEZPEČNOSTNÉ INFORMÁCIE, UMIESTNENIE A NA ELEKTRICKÚ PRÍSLUŠENSTVO.

BLUEPALM BPPAC12000FW - Registrace - 4

BLUEPALM BPPAC12000FW - Registrace - 5

BLUEPALM BPPAC12000FW - Registrace - 6

BLUEPALM BPPAC12000FW - Registrace - 7

BLUEPALM BPPAC12000FW - Registrace - 8

text_image Diagram of a portable air conditioner unit with numbered parts labeled 1 to 5

BLUEPALM BPPAC12000FW - Registrace - 9

natural_image Diagram of a coiled spring with labeled component (no text or symbols present)

BLUEPALM BPPAC12000FW - Registrace - 10

BLUEPALM BPPAC12000FW - Registrace - 11

text_image Technical diagram of a portable air conditioner unit with numbered labels pointing to components

BLUEPALM BPPAC12000FW - Registrace - 12

OVLÁDACÍ PANEL A DIAL'KOVÉ OVLÁDANIE
BLUEPALM BPPAC12000FW - Registrace - 13

flowchart
graph TD
    A["TIMER"] --> B["1"]
    C["FAN"] --> D["4"]
    E["▲"] --> F["3"]
    G["▼"] --> H["2"]
    I["MODE"] --> J["1"]
    K["POWER"] --> L["1"]

BLUEPALM

natural_image Technical line drawing of a mechanical device with coiled tubing and ventilation grilles (no text or symbols)

- Vložte hadicu na odvod vzduchu do tesniacej dosky, nastavte širku otvoru okna tak, aby bolo okno správne zarovnané s tesniacou doskou; dížka tesniacej dosky je nastavitelná.

BLUEPALM BPPAC12000FW - BLUEPALM - 1

natural_image Line drawings of two different air conditioning machines with ventilation ducts and control panel (no text or symbols)
natural_image Technical line drawing of a mechanical device with a cross-shaped X-shaped component (no text or symbols)

Poznámka:

natural_image Line drawing of a portable air conditioner unit with cooling fan and cup (no text or symbols)
natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

ČISTENIE A ÚDRŽBA

natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

BLUEPALM BPPAC12000FW - ČISTENIE A ÚDRŽBA - 1

natural_image Line drawing of a portable air conditioner unit with cooling fan and ventilation grilles (no text or symbols)

SEZÓNNE ČISTENIE

text_image QR code with a blue house icon in the center, likely linking to a digital service or application.

Scan QR code

Registrácia

text_image 09:17 Add Device Turn on Bluetooth Bluetooth makes your device more disassembled. Add Device Select 2.4 GHz Wi-Fi Network and enter password. If your WiFi is 5GHz, please set it to be 2.4GHz. Common router setting method X Wi-Fi - 5GHz ✓ Wi-Fi - 2.4GHz XK001 Select Wi-Fi 1234E6789 Add Manually Electrical Air Conditioning Lighting Sensors Air Control unit (INTe-FF) Air Control unit (INTe-FF) Large Home Appliances Next 09:17 Reset the device Press and hold the RESET button for 5 seconds will the indicator while (subject to the user memory). Select the status of the indicator light or hear the beep: Think Slowy Think Quickly 09:21 Connect your mobile phone to the device's hotspot Connect your phone to the hotspot when below: WLAN ✓ SmartLife-XXXX ✓ SL-XXXX "便利" Wants to Join WLAN Network "SmartLife-E760"? Cancel Join Go to Connect 10:12 Add Device I recommend(s) added successfully. Portascell Air Conditioner(L... Add successfuls Done

Automatické pridanie zariadenia

text_image Data Modification All Devices Desktop center Wireless Settings Smartphone Ultra-Service Watts One Mode Sensors Read TV App Speech UP Wireless Music Text Inference All Devices Devices to be added: 1 Air Conditioner Add Enter Wi-Fi Information Choose Wi-Fi and enter password) Xiaomi 12 Pro 1234567890 Next

BLUEPALM BPPAC12000FW - Automatické pridanie zariadenia - 1

text_image Add Device Air Conditioner Being added Add Device Air Conditioner Added successfully Done 30°C Good Good 51.6% Speed PR/CC Speed or on Speed normal Daily Modification All Devices Air Conditioner

Aplikácia funguje aj s Amazon Alexa a Google Assistant.
BLUEPALM BPPAC12000FW - Automatické pridanie zariadenia - 2
WORKS WITH amazon alexa

BLUEPALM BPPAC12000FW - Automatické pridanie zariadenia - 3
works with the Google Assistant

Technické údaje WiFi
Bezdrótová technológia:Wifi (WLAN)
Frekvencia rádiového prevádzky2412 MHz – 2472 MHz
Pracovná frekvencia BLE2402 MHz – 2480 MHz
Typ modulácie802.11b: DSSS802.11g: OFDM802.11n (20 MHz): OFDM
Softvér s pevnou frekvenciouSecureCRT.exe
Zosilnenie antény2,5 dBi
Typ antényPCB
Prenosový výkon:520 dBm

BLUEPALM

ERROR

Zist'ovanie chýb

natural_image Front view of a white industrial air conditioner unit with control panel and digital display (no visible text or symbols)

FELICITĂRI! VĂ MULȚUMIM CĂ AȚI ALES UN PRODUS BLUEPALM.

RO

BLUEPALM BPPAC12000FW - ERROR - 1

text_image QR code image containing encoded data, no visible human-readable text

VĂ RUGĂM SĂ CITIȚI CU ATENȚIE INSTRUCTIUNILE DE UTILIZARE ÎNAINTE DE A ÎNCEPE ASAMBLAREA, INSTALAREA, FUNCTIONAREA SAU ÎNTREȚINEREA. PROTEJAȚI-VĂ PE DUMNEAVOASTRĂ ȘI PE CEILALȚI RESPECTÂND INSTRUCTIUNILE DE SIGURANȚĂ. NERESPECTAREA INSTRUCTIUNILOR AR PUTEA DUCE LA VĂTĂMĂRI CORPORALE ȘI/SAU DAUNE MATERIALE ȘI/SAU PIERDEREA ACOPERIRII GARANTIEI!

INFORMATII IMPORTANTE PRIVIND SIGURANTA, LOCATIA SI LA INSTALATIA ELECTRICĂ CONEXIUNE.

BLUEPALM BPPAC12000FW - ERROR - 2

text_image Warning symbols including no hand, flame, open book, and warning triangle

https://www.schuss-home.at/downloads

text_image Diagram of a portable air conditioner unit with numbered parts labeled 1 to 5

BLUEPALM BPPAC12000FW - ERROR - 3

natural_image Diagram of a coiled spring with labeled component (no text or symbols present)

BLUEPALM BPPAC12000FW - ERROR - 4

BLUEPALM BPPAC12000FW - ERROR - 5

text_image Technical diagram of a portable air conditioner unit with numbered labels pointing to components

BLUEPALM BPPAC12000FW - ERROR - 6

PANOU DE CONTROL ŞI TELECOMANDĂ
BLUEPALM BPPAC12000FW - ERROR - 7

flowchart
graph TD
    A["TIMER"] --> B["1"]
    C["FAN"] --> D["4"]
    E["▲"] --> F["3"]
    G["▼"] --> H["2"]
    I["MODE"] --> J["1"]
    K["POWER"] --> L["1"]

BLUEPALM

text_image ① ② ③ ④ ⑤ ⑥ °C/°F

AMPLASARE ŞI INSTALARE

Alcătuire

natural_image Technical line drawing of a mechanical device with coiled tubing and housing (no text or symbols)
natural_image Technical line drawing of two different air conditioning machines with ventilation ducts and control panel (no text or symbols)
natural_image Technical line drawing of a portable air conditioner unit with a cross-shaped logo (no text or symbols)

Observatie:

natural_image Line drawing of a portable air conditioner unit with cooling fan and bucket (no text or symbols)

BLUEPALM

Sfat:

natural_image Line drawing of a portable electric fan with ventilation grille and cooling fins (no text or symbols)
natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

BLUEPALM BPPAC12000FW - Sfat: - 1

natural_image Line drawing of a portable air conditioner unit with cooling fan and ventilation grilles (no text or symbols)

CURĂTENIE SEZONIERĂ

text_image QR code with a blue house icon in the center, likely linking to a digital service or application.

Scan QR code

Înregistrare

text_image 09:17 我的家... Learn abeu DIT Homep 2011 02:00:48 Add Device Create Scene Add Quick Toggle Card Scan Take way All Devices Edit Add Device Turn on Bluetooth? Bluetooth makes your device more disassembled. Add Manually Electrical Air Conditioning Lighting Sensors Air Cool out (BLDefA) Discharge (AC-5) Cathout (Zdsm) Large Home Appliances Select 2.4 GHz Wi-Fi Network and enter password. If your WLAN is 5GHz, please set it to be 2.4GHz. Common router setting method X Wi-Fi - 5GHz ✓ Wi-Fi - 2.4GHz XK001 Select Wi-Fi 123456789 Next 09:17 Reset the device Press and hold the RESET button for 5 seconds will the indicator white (subject to the user morning) Select the status of the indicator light or hear the beep: Think Slowy Think Quickly 09:21 Connect your mobile phone to the device's hotspot Connect your phone to the hotspot shows below: WLAN ✓ SmartLife-XXXX ✓ SL-XXXX “请勿”Wants to Join WLAN Network "SmartLife-E760"? Cancel Join Go to Connect 10:12 Add Device Lemon(s) added network only Portascift Air Conditioner(L)... Add successful Done
text_image Data Modification All Devices Desktop center Wireless Settings Smartphone Ultra-Service Watts One Mode Sensors Read TV App Speech UP Wireless Music Text Inference All Devices Devices to be added: 1 Air Conditioner Add Enter Wi-Fi Information Choose Wi-Fi and enter password) Xiaomi 12 Pro 1234567890 Next

BLUEPALM BPPAC12000FW - Înregistrare - 1

text_image Add Device Air Conditioner Being added Add Device Air Conditioner Added successfully Done 30°C Good Good 51.6% Speed PR/CC Speed or on Speed normal Daily Modification All Devices Air Conditioner

BLUEPALM BPPAC12000FW - Înregistrare - 2
works with the Google Assistant

Mobile air conditioner BPPAC12000FW

BLUEPALM BPPAC12000FW - Mobile air conditioner BPPAC12000FW - 1

natural_image Front view of a white industrial air conditioner unit with control panel and digital display (no visible text or symbols)

CONGRATULATIONS! THANK YOU FOR CHOOSING A BLUEPALM PRODUCT.

BLUEPALM BPPAC12000FW - Mobile air conditioner BPPAC12000FW - 2

Latest operating instructions and other languages

Download the latest operating instructions in different languages by going to www.bluepalm.at/downloads or scanning the QR code shown. Follow the instructions on the website.

BLUEPALM BPPAC12000FW - Latest operating instructions and other languages - 1

text_image QR code image containing encoded data, no visible human-readable text

PLEASE READ THE INSTRUCTION MANUAL CAREFULLY BEFORE STARTING ASSEMBLY, INSTALLATION, OPERATION OR MAINTENANCE. PROTECT YOURSELF AND OTHERS BY FOLLOWING THE SAFETY INSTRUCTIONS. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONS AND / OR PROPERTY DAMAGES AND / OR LOSS OF THE WARRANTY CLAIM!

IMPORTANT INFORMATION ON SAFETY, LOCATION AND ELECTRICAL CONNECTION.

BLUEPALM BPPAC12000FW - Latest operating instructions and other languages - 2

text_image Warning symbols including no hand, flame, open book, and lightning warning signs
  1. Read all instructions carefully before using the device.
  2. Use this device only in accordance with the instructions in the manual. Any other use not recommended by the manufacturer could result in fire, electric shock, or personal injury.
  3. This device is intended for cooling in households and may not be used for any other purpose.
  4. The device is not suitable for continuous and precision operation and should not be used for cooling electrical systems (e.g: in server rooms).
  5. It is forbidden to modify the characteristics of this device in any way and only use replacement parts and accessories recommended by the manufacturer (failure to do so will void the warranty).
  6. For any repairs to the device, power plug or cable, always and exclusively contact authorized service centers. The customer service centers can be accessed online at www.bluepalm.at.
  7. Remove the packaging and make sure the air conditioner is not damaged. If in doubt, do not use the air conditioner and contact the service center or your seller.
  8. Keep children away from packaging material. If swallowed there is danger of suffocation!

BLUEPALM

  1. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service center to avoid all possible risks.
  2. The device must be installed in accordance with local electrical system installation and operating instructions.
  3. The electrical socket in which you connect the device must not be defective or loose and must be suitable for the required current load and above all be reliably earthed. If in doubt, have your electrical installation checked by a qualified electrician.
  4. Before connecting to the device to the electrical socket, you must check whether the type of current and the mains voltage comply with the information given on the back of the device.
  5. Avoid using an extension cord as it could overheat and cause a fire.
  6. Do not twist or bend the power cord.

  7. This device may only be used by adults.

  8. Children under the age of 8 and persons with limited physical, mental, sensory or mental abilities, and lack of experience and knowledge may only use this device if it is under appropriate supervision and provide detailed instructions for use of the device in a safe manner and how the existing dangers have been described.
  9. Do not let children play with the packaging and make sure that children do not play with the device. ●
  10. Do not use the air conditioner outdoors.
  11. Do not use the device with wet hands.
  12. Never operate the device in areas where gas, oil or sulfur are present.
  13. Do not place the device near sources of heat (e.g.: near heating systems and gas heaters) and avoid direct sunlight.
  14. Keep a minimum distance of at least 50cm to combustible materials (e.g., alcohol, etc.) or pressurized vessels (e.g., spray containers).
  15. Do not use the air conditioner near water or high humidity, e.g.: in the wet basement, next to swimming pool, bath or shower. Make sure that no water gets into the device.
  16. Do not place heavy or hot objects on the unit and never cover the unit.
  17. Never insert fingers, pins or other objects into the unit, being careful not to block the air inlet and outlet.
  18. Always turn off the power before unplugging the power cord.
  19. Do not pull the power cord to disconnect the device from the mains. Always pull on the plug to pull out the power cord. Do not handle the plug with wet hands to avoid electric shock.
  20. Unplug the device when not in use before cleaning, servicing or moving it from one location to another.
  21. If the device has a defect, switch it off with the on / off button on the control panel and contact the customer hotline.

  22. Maintain the air conditioner in good condition by caring for and cleaning the unit.

  23. The air filter should be cleaned at least once a week.

  24. Store the device vertically in a safe place, dry and out of the reach of children, when not in use. Do not cover the device with plastic packaging.

BLUEPALM

  1. Store the unit in a room with no ignition sources in operation (e.g.: open fire, service gas appliance or electric heater with open heat source).
  2. The air conditioner should be transported in an upright position or slightly sideways position. Empty the internal condensate tank first. Wait at least one hour after transporting the device before turning on the device.
  3. Always contact authorized service centers for repairs to the device, power plug, or cable.
  4. Do not use any means to accelerate or eliminate the defrost process, the device will do it on its own.
  5. If you have any questions about maintenance, you can contact the manufacturer's authorized hotline / service center.

WARNING

The main power switch and the on / off switch should not be used as the sole means of power disconnection. Always unplug the power cord before servicing or moving the unit.

To avoid the risk of electric shock, disconnect the plug from the power outlet when not in use - as well as before each cleaning.

SPECIFIC INFORMATION ON REFRIGERANT R290

  1. R290 is a refrigerant compliant with EU environmental regulations.
  2. The refrigerant is odorless.
  3. The device should be installed in a room where no ignition sources are active (e.g., open flames, operating gas or electric appliances with exposed heat sources).
  4. Do not puncture or burn the air conditioning unit.
  5. Ensure that the cooling circuit is not punctured.
  6. Non-ventilated rooms where the unit is installed, operated, or stored must be constructed to prevent the accumulation of potential refrigerant leaks. This helps to avoid fire or explosion risks caused by the ignition of refrigerant from electric heaters, stoves, or other ignition sources.
  7. Store the device in a way that prevents any mechanical damage.
  8. Personnel working on or intervening in a cooling circuit must hold a valid certificate issued by an authorized authority, certifying their expertise in handling refrigerants, in accordance with an industry-recognized assessment specification.
  9. Repairs must be carried out in accordance with the instructions of the device's manufacturer. Repair and maintenance tasks requiring additional personnel should be performed under the supervision of a qualified person responsible for handling flammable refrigerants.

BLUEPALM

BLUEPALM BPPAC12000FW - BLUEPALM - 1

BLUEPALM BPPAC12000FW - BLUEPALM - 2

RECYCLING

The packaging materials can be recycled. Therefore it is recommended to dispose of them in sorted waste.

DISPOSAL

The crossed-out bin symbol requires the separate disposal of waste electrical and electronic equipment (WEEE). Electrical and electronic equipment may contain hazardous and environmentally hazardous substances. Therefore, do not dispose of it in unsorted residual waste, but at a designated collection point for waste electrical and electronic equipment. This helps to protect resources and the environment. For more information, contact your dealer or the local authorities.

BLUEPALM BPPAC12000FW - DISPOSAL - 1

DISPOSAL OF BATTERIES

In accordance with Legislative Decree 188 of November 20, 2008, which implements Directive 2006/66/EC on batteries, accumulators and related waste, the symbol of the crossed-out wheelie bin on the battery indicates that it is prohibited to dispose of waste batteries in household waste. Batteries and accumulators contain substances that are highly harmful to the environment.

The user is obliged to dispose of used batteries at collection points in the community or in the appropriate containers. The service is free of charge. In this way, legal requirements are met and the environment is protected.

These symbols can be found on batteries:

Li = battery contains lithium

AI = battery contains alkali

Mn = battery contains manganese

CR 2025 (Li); AA (Al, Mn); AAA (Al, Mn)

BLUEPALM BPPAC12000FW - DISPOSAL OF BATTERIES - 1

DECLARATION OF CONFIRMITY

We hereby confirm that this article complies with the essential requirements, regulations and directives of the EU.

The detailed declaration of conformity can be viewed at any time under the following link:

www.bluepalm.at.at/downloads/doc/BPPAC12000FW.pdf

Errors and technical changes reserved.

www.bluepalm.at

BLUEPALM

PRODUCT INSTRUCTION

MAIN PART AND COMPONENTES

  1. Handle
  2. Air inlet (L)
  3. Control panel
  4. Wind guide bar
  5. Caster
  6. Remote controller
  7. Air inlet (R)
  8. Air outlet
  9. Dehumidification drainage nozzle
  10. Air inlet grille
  11. Exhaust duct assembly
  12. Window sealing plate assembly

BLUEPALM BPPAC12000FW - MAIN PART AND COMPONENTES - 1

text_image Diagram of a portable air conditioner unit with numbered parts labeled 1 to 5

BLUEPALM BPPAC12000FW - MAIN PART AND COMPONENTES - 2

natural_image Technical line drawing of a coiled spring or hose component with no visible text or symbols

BLUEPALM BPPAC12000FW - MAIN PART AND COMPONENTES - 3

BLUEPALM BPPAC12000FW - MAIN PART AND COMPONENTES - 4

text_image Technical diagram of a portable air conditioner unit with numbered components labeled 7, 8, 9, and 10.

BLUEPALM BPPAC12000FW - MAIN PART AND COMPONENTES - 5

CONTROL PANEL AND REMOTE CONTROLLER
BLUEPALM BPPAC12000FW - MAIN PART AND COMPONENTES - 6

flowchart
graph TD
    A["TIMER"] --> B["1"]
    C["FAN"] --> D["2"]
    E["▲"] --> F["3"]
    G["▽"] --> H["MODE"]
    I["POWER"] --> J["1"]
    B --> F
    D --> F
    H --> J

BLUEPALM

1. Power key

Press the key to turn ON/OFF the A/C.

2. Mode key

Press the key to choose cooling, wind, dehumidification and heating(cooling only model has no heating) mode.

3. Temperature/ time adjusting key

Press the key at cooling mode to increase/reduce the setting temperature; press it at timing mode to adjust timing ON/OFF time; press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature.

4. Fan key

Press the key to choose high/ low gear wind speed.

5. Timer Key

press this key to set a timer for auto start or auto stop.

6. Swing key

Press this key at any time after turning on the A/C to swingthe wind guide bar automatically.

7. °C/ °F switching key

Press the key to switch ^ C and ^ F.

PRODUCT OPERATION

PLACEMENT AND INSTALLATION

Placement

- Place it at even and dry place, and keep it at least 50cm away from its surrounding object.

BLUEPALM BPPAC12000FW - Placement - 1

text_image Diagram of a mobile device control panel with labeled icons and function keys

BLUEPALM
BLUEPALM BPPAC12000FW - Placement - 2

text_image 50cm

Installation

- Screw the exhaust duct assembly in the air outlet behind the panel (anticlockwise).

BLUEPALM BPPAC12000FW - Installation - 1

natural_image Technical line drawing of a mechanical device with coiled tubing and a housing (no text or symbols)

- Insert the air exhaust hose into the window sealing plate, adjust opening width of window so that the window can match with the sealing plate properly; length of the sealing plate is adjustable.

BLUEPALM BPPAC12000FW - Installation - 2

natural_image Technical line drawing of two air conditioning machines with ventilation ducts and control panel (no text or symbols)

BLUEPALM

Incorrect installation

- It's important to keep the exhaust duct smooth. Incorrect installation will affect work of the A/C.

• Prevent the exhaust duct from seriously bending.

• Ensure air can flow smoothly in the duct.

Warning:

The exhaust duct is designed especially for this model. Don't replace or lengthen it; otherwise, it will result in failure.

BLUEPALM BPPAC12000FW - Warning: - 1

natural_image Technical line drawing of a mechanical device with a grid base and X-shaped component (no text or symbols)

Notice:

Max. developed length of the exhaust duct is 1,500mm. It's better to shorten it while use and keep it horizontal while installation.

OPERATION METHOD

Cooling mode

- When the A/C enters cooling mode automatically or cooling mode is selected after power ON, the cooling indicator lamp lights up.

- Press Up/Down key to adjust setting temperature (16°C\~30°C).

• Press Speed key to choose High/Mid/Low speed.

Fan mode

- When pressing mode key or choosing Fan mode by pressing the remote controller, the wind indicator lamp lights up.

• Press Speed key to choose High/Mid/Low speed.

• Temperature can't be set.

Dehumidification mode

- When pressing mode key or choosing dehumidification mode by pressing the remote controller, the dehumidification indicator lamp lights up.

- Remove the dehumidification water wedge, insert water manifold, place the other end of the water manifold into the water vessel or drainage passage, as shown in the right figure.

- After entering the dehumidification mode, if room temperature≥17°C (62°F), the compressor is ON. Then control as follows: when room temperature ≤15°C(59°F)

BLUEPALM BPPAC12000FW - Dehumidification mode - 1

natural_image Line drawing of a portable air conditioner unit with cooling fan and bucket (no text or symbols)

the compressor is OFF; when temperature increases to room temperature≥17°C, the compressor is started again (in order to protect the compressor, it will be restarted 3min. later).

BLUEPALM

  • In dehumidification mode, the fan is defaulted to run at low speed, and wind speed can't be adjusted.
  • Temperature can't be set. (Note: when use dehumidify function, should remove exit pipe components, otherwise, it will cause worse dehumidify performance, and appear "FL" water full alarm)

Timer mode

  • In standby state, press the Timer key to set ON time. Press Up and Down keys to set ON time (1\~24H), and the timer indicator lamp lights up.
  • In ON state, pressure the timer key to set OFF time. Press Up and Down keys to set OFF time (1\~24H), and the timer indicator lamp lights up.

CLEAN AND MAINTENANCE

Drainage Methode

This product is equipped with automatic water vaporization system. The condenseris cooled with the circulating of condensing water, so as to improve cooling efficiency and save energy.

- If the internal vessel is full of water, the display screen will display "FL", and the compressor stops working automatically. After power off, unscrew the water cover, pull out the water wedge to drain off water, and it will become normal after being restarted.

BLUEPALM BPPAC12000FW - Drainage Methode - 1

natural_image Line drawing of a portable air conditioner unit with fan and cooling fins (no text or symbols)

MAINTENANCECE

Notice: in order to avoid electric shock, please turn off the A/C and unplug before maintenance or repair.

CLEANING

• Unplug before cleaning.
- Wipe with soft semi-dry cloth. Don't use chemical reagent, such as benzene, alcohol and gasoline etc; otherwise surface of the A/C and even the whole A/C will be damaged.
• Prevent water from spattering in the A/C.

BLUEPALM

FILTER SCREEN

  • Wash the filter screen once every two weeks. If it is blocked by dust, efficiency of the A/C will be reduced.
    Take out the air inlet grille and pull out the filter screen at both sides according to the direction shown in the following figures.
  • Put the filter screen into the warm water (about 40°C) added with neutral detergent, dry it at a shady place after cleaning.

BLUEPALM BPPAC12000FW - FILTER SCREEN - 1

natural_image Line drawing of a portable electric heater with fan and cooling fins (no text or symbols)

BLUEPALM BPPAC12000FW - FILTER SCREEN - 2

natural_image Line drawing of a portable air conditioner unit with cooling fan and heating element (no text or symbols)

SEASONAL CLEANING

If the A/C will not be used for a long time:

• Pull out the water wedge to drain.
• Run the A/C in fan mode for 2H till its inside is dry.
• Turn off the A/C and unplug.
• Wash the filter screen and reassemble it.
• Dismantle the exhaust duct and keep it properly.
• Cover the A/C with a plastic bag and place it at a dry place.

Smart Home Wi-Fi Connection Guide

IMPORTANT

Please note that only 2.4GHz networks are supported!

Transmission power: max. 100mW

App installation

Download the "Smart life" app from the Play Store (Android) or the App Store (iOS). The following QR code will take you directly to the app download:

BLUEPALM BPPAC12000FW - App installation - 1

text_image QR code with a blue house icon in the center, likely linking to a digital service or application.

Scan QR code

Registration

If you do not yet have a Smart Life account, you can register or log in with a verification code that will be sent to you via SMS.

To register:

  • Navigate to the registration area in the app.
  • The system will automatically detect your country or region. You also have the option of selecting the country code manually. Enter your mobile phone number or email address and tap "Continue."
  • If you choose the mobile phone number option, enter the verification code you received via SMS. Then set a password and tap "Confirm" to complete the registration.

Adding a device manually:

  • When the air conditioner is in standby mode, press and hold the FAN button on the control panel for 3 seconds to enter Wi-Fi connection mode. The Wi-Fi signal light will start flashing.
  • Open the Smart Home app and tap "+" in the upper right corner to add a new device via the network.
  • Make sure the operating light is flashing, tap "Confirm" that the light is flashing, and follow the instructions on the screen.
  • Select the Wi-Fi network (note: the network must be in the 2.4 GHz band) and enter the password. The device will start the pairing process and connect to the app.
  • Once the device has been successfully configured, the air conditioner will be displayed on the Smart Home page. Tap on it to access the device controls.

BLUEPALM

BLUEPALM BPPAC12000FW - BLUEPALM - 1

text_image 09:17 我的家... Learn abeu DIT Homep 2011 02:00:48 Add Device Create Scene Add Quick Toggle Card Scan Take way All Devices Edit Add Device Turn on Bluetooth? Bluetooth makes your device more disassembled. Add Manually Electrical Air Conditioning Lighting Sensors Air Cool out (BLDefA) Discharge (ACF) Cathout (Zdsm) Large Home Appliances Select 2.4 GHz Wi-Fi Network and enter password. If your WLAN is 5GHz, please set it to be 2.4GHz. Common router setting method X Wi-Fi - 5GHz ✓ Wi-Fi - 2.4GHz XK001 Select Wi-Fi 123456789 Next 09:17 Reset the device Press and hold the RESET button for 5 seconds will the indicator white (subject to the user morning) Select the status of the indicator light or hear the beep: Think Slowy Think Quickly 09:21 Connect your mobile phone to the device's hotspot Connect your phone to the hotspot shows below: WLAN ✓ SmartLife-XXXX ✓ SL-XXXX “请勿”Wants to Join WLAN Network "SmartLife-E760"? Cancel Join Go to Connect 10:12 Add Device Lemon(s) added network only Portascift Air Conditioner(L)... Add successful Done

Adding a device automatically

■ Make sure the device is in standby mode before connecting.
- Press the "FAN" button for 3 seconds to switch to Wi-Fi connection mode, and the Wi-Fi signal light will start flashing.
■ Activate Bluetooth on your phone.
- Open the app and wait a moment until the device is automatically detected and displayed.
- Click the "Add" button to connect.
- Enter the WiFi SSID (WiFi connection name), enter the WiFi password, and click "Next" to continue with the setup. (Note: The network must be in the 2.4 GHz band.)
- When the progress bar is complete, the device pairing interface will be displayed and the device will be successfully connected.
- Click the "Done" button to go to the device control interface.

BLUEPALM
BLUEPALM BPPAC12000FW - Adding a device automatically - 1

text_image Data Modification All Devices Desktop center Wireless Settings Smartphone Ultra-Service Watts One Mode Sensors Read TV App Speech UP Wireless Music Text Inference All Devices Devices to be added: 1 Air Conditioner Add Enter Wi-Fi Information Choose Wi-Fi and enter password) Xiaomi 12 Pro 1234567890 Next

BLUEPALM BPPAC12000FW - Adding a device automatically - 2

text_image Add Device Air Conditioner Being added Add Device Air Conditioner Added successfully Done 30°C Good Good 51.6% Speed PR/CC Speed or on Speed normal Daily Modification All Devices Air Conditioner

The application also works with Amazon Alexa and Google Assistant.

BLUEPALM BPPAC12000FW - Adding a device automatically - 3

WORKS WITH amazon alexa

BLUEPALM BPPAC12000FW - Adding a device automatically - 4

works with the Google Assistant

Technical Specifications WiFi
Wireless technology:WiFi (WLAN)
Radio operating frequency2412MHz-2472MHz
BLE operating frequency2402 MHz–2480 MHz
Modulation type802.11b: DSSS802.11g: OFDM802.11n (20 MHz): OFDM
Fixed frequency softwareSecureCRT.exe
Antenna gain2.5 dBi
Antenna typePCB
Transmission power:520dBm

COMMON FAILURES AND DIAGNOSIS

INTELLIGENT ERROR DETECTION

Error-detecting codeMulti-functional defection
E1Error of the coil's temperature sensor
E2Error of indoor temperature sensor
E4Anti-freezing protection: temperature of the coil is too low and the whole A/C is off. When temperature exceeds 8°C, the protection is released and previous working state is recovered.

TROUBLE-SHOOTING

In case of any of the following trouble, please contact professional maintenance personnel time.

TROUBLECAUSESOLUTION
The A/C doesn’t workNot plug inPlug in
The display panel displays “FL”Restart the A/C after power off and draining, then it will become normal
Time OFF function is startedThe A/C can be restarted 3 minutes after being turning off.
The A/C starts frequentlyDirect sunlightDraw the curtain
Doors and windows keep open; there are lots of people or heat source in roomClose doors and windows, remove heat source
Filter screen is very dirtyClean or replace it
Air inlet or air outlet is blockedRemove the stem
Big noise of the A/CThe A/C is placed unevenlyPlace it at even and firm ground, avoid shaking
The compressor doesn’t workIts delay protection is startedWait for 3min., turn on it after temperature decreases

Notice: When there is any abnormal to the A/C, turn it off and unplug, and then contact professional maintenance personnel.

The above technical parameters are subject to change without notice.

Technical information
Item no.BPPAC12000FW
Cooling performance12.000Btu
Max. power consumption1370W
Input voltage220-240V~
Frequency50Hz
WIFI transmission frequency:2.4 GHz
Transmitting power:max. 100 mW
Refrigerant/capacity/GWPR290/0.245kg/3
EER energy efficiency2.6
Energy efficiency classA
Air circulation350m3/h
Noise level (sound power level)65dB
Weight29 kg
Measurements443x830x340 mm
Contact addresses for further informationSchuss Home Electronic GmbHScheringgasse 3, A-1140 WienTel: +43 (1) 97 0 21 – 0Serviceline: +43 (1) 97 0 21 – 502www.bluepalm.atFB-Nr: 236974 t / FB-Gericht: Wien

BLUEPALM

Information requirements for single duct and double duct air conditionierP
Information to identify the model(s) to which the information relates to:
DescriptionSymbolValueUnit
Description P_rated for cooling3,420kW
Rated capacity for cooling P_rated for heating-kW
Rated capacity for heating P_EER 0.963kW
Rated power input for cooling P_COP -kW
Rated power input for heating EER_d 2.62-
Rated Energy efficiency ratio COP_d --
Information identifying the model(s) to which the information relates:
DescriptionSymbolValueUnit
Power consumption in thermostat-off mode P_TO N/AW
Power consumption in standby P mode P_SB 0.44W
Electricity consumption of single/double duct appliances (indicate for cooling and heating separately) Q_SD SD: 1.303 (cooling)kWh/h
Sound power level L_WA 63dB(A)
Global warming potentialGWP3kgCO2 eq.
Contact details for obtaining more informationSchuss Home Electronic GmbHScheringgasse 31140 Vienna, AustriaTel.: +43 (1) 97 0 21 – 0www.becool.at

BLUEPALM

WARRANTY

By purchasing a BLUEPALM quality product you have acquired an innovative, long lasting and reliable item.

For this BLUEPALM device we grant a warranty of 2 years from the date of purchase, valid in Austria only.

In the unlikely event that service work is required on your device in this period we warrant free repair (spare parts and labour) or (subject to Schuss's decision) to replace the product. In the event that neither repair nor exchange make sense from an economical perspective we reserve the right to issue a credit based on current value.

When dealing with air conditioning devices you should always contact the customer hotline first (see label on the device or the title page of the instruction manual), in case of fans contact your dealer or us directly. Please note that repair not performed by the authorised workshop in Austria immediately renders this warranty void.

This warranty does not include:

• Repair of replacement of parts due to normal wear
- Damage due to non-compliance with the instruction manual
• Devices that are used commercially – even in part
• Devices damaged by external forces (falling, impact, cracking, improper use etc.) as well as aesthetic wear
• Devices that have been used improperly
• Devices that were not opened by our authorised workshop.
- Damages caused by improperly closed condensation drains on air conditioning devices or improperly inserted water container.
- Unfulfilled customer expectations.
• Damage caused by force majeure, water, lightning and overvoltage.
• Devices on which type denomination and/or serial number on the device have been erased, rendered illegible or removed.
• Service work not performed by our authorised workshops, transport costs to an authorised workshop or us and back as well as associated risks.

Please note that within the warranty period we charge a flat rate of 60 € (indexed as per consumer price index 2010, June 2015) in case of operating errors or if no fault can be found.

The total warranty period of 2 years is not extended if warranty service is performed (repair or device replacement).

The 2 year warranty is only valid if the original invoice (must contain name and address of the dealer as well as full device name) and the respective warranty certificate are produced, on which the device type and serial number (can be found on the box and the device's rear or bottom) are to be noted! Only the statutory warranty coverage applies if the warranty certificate cannot be produced!

Please note that the statutory warranty coverage is not altered by this warranty and that it applies in full regardless.

Schuss Home Electronic GmbH and its vicarious agents are only liable for damages in case of gross negligence or intent. Liability for loss of profit, expected but not incurred savings, consequential damages and damages from third party claims is excluded in any case. Damages to or for recorded data are always excluded from the liability for damages.

Congratulations on your choice. We hope you will enjoy using your BLUEPALM device!

ADDRESS

Schuss Home Electronic GmbH

1140 Vienna, Scheringgasse 3

Tel.: +43 (0)1/ 970 21

Type designation: ....

Serial number: ....

Together with the device, this warranty certificate must be handed to the authorised workshop or dealer you bought the device from in the event of a warranty claim!

WICHTIG!

These instructions are only for the BLUEPALM-Service center!

BLUEPALM BPPAC12000FW - WICHTIG! - 1

A Service or repairing of the device must only be performed by a qualified technician who is allowed to handle the R290 refrigerant.

Do not attempt to repair or open the case of the air conditioner yourself, this leads to the immediate loss oft he warranty.

INSTRUCTIONS FOR REPAIRING APPLIANCES CONTAINING R290

1 GENERAL INSTRUCTIONS

1.1 Checks to the area

Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

1.2 Work procedure

Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed.

1.3 General work area

All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

1.4 Checking for presence of refrigerant

The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak section equipment being used is suitable for use with flammable refrigerants, i.e. non sparking, adequately sealed or intrinsically safe.

1.5 Presence of fire extinguisher

If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO 2 fire extinguisher adjacent to the charging area.

1.6 No ignition sources

BLUEPALM

No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including ecigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

1.7 Ventilated area

Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

1.8 Checks to the refrigeration equipment

Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: the charge size is in accordance with the room size within which the refrigerant containing parts are installed; the ventilation machinery and outlets are operating adequately and are not obstructed; if an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected; refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.

1.9 Checks to electrical devices

Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.

Initial safety checks shall include: Those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; that there no live electrical components and wiring are exposed while charging, recovering or purging the system; that there is continuity of earth bonding.

2 REPAIRS TO SEALED COMPONENTS

2.1 During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
2.2 Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected.

This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer's specifications.

NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.

3 REPAIR TO INTRINSICALLY SAFE COMPONENTS

Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.

Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

4 CABLING

BLUEPALM

Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.

5 DETECTION OF FLAMMABLE REFRIGERANTS

Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

6 LEAK DETECTION METHODS

The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need recalibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.

7 REMOVAL AND EVACUATION

When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to: remove refrigerant; purge the circuit with inert gas; evacuate; purge again with inert gas; open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be “flushed” with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipework are to take place.

Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.

8 CHARGING PROCEDURES

In addition to conventional charging procedures, the following requirements shall be followed.

  • Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
  • Cylinders shall be kept upright.
  • Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
  • Label the system when charging is complete (if not already).
  • Extreme care shall be taken not to overfill the refrigeration system.
  • Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak Tested on completion of charging but prior to commissioning. A follow up leak test shall be Carried out prior to leaving the site.

9 DECOMMISSIONING

Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.

  1. Become familiar with the equipment and its operation.
  2. Isolate system electrically.
  3. Before attempting the procedure ensure that :mechanical handling equipment is available, if required, for handling refrigerant cylinders; all personal protective equipment is available and being used correctly; the recovery process is supervised at all times by a competent person; recovery equipment and cylinders conform to the appropriate standards.

BLUEPALM

  1. Pump down refrigerant system, if possible.
  2. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
  3. Make sure that cylinder is situated on the scales before recovery takes place.
  4. Start the recovery machine and operate in accordance with manufacturer's instructions.
  5. Do not overfill cylinders. (No more than 80 % volume liquid charge).
  6. Do not exceed the maximum working pressure of the cylinder, even temporarily.
  7. When the cylinders have been filled correctly and the process completed, make sure 11. that the cylinders and the equipment are removed from site promptly and all isolation
  8. valves on the equipment are closed off.
  9. Recovered refrigerant shall not be charged into another refrigeration system
  10. unless it has been cleaned and checked.

10 LABELLING

Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.

11 RECOVERY

When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.

The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt.

The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.

If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

Competence of service personnel

General

Special training additional to usual refrigerating equipment repair procedures is required when equipment with flammable refrigerants is affected.

In many countries, this training is carried out by national training organizations that are accredited to teach the relevant national competency standards that may be set in legislation. The achieved competence should be documented by a certificate.

Training

The training should include the substance of the following:

Information about the explosion potential of flammable refrigerants to show that flammables may be dangerous when handled without care.

Information about potential ignition sources, especially those that are not obvious, such as lighters, light switches, vacuum cleaners, electric heaters.

Information about the different safety concepts:

Unventilated – (see Clause GG.2) Safety of the appliance does not depend on ventilation of the housing. Switching off the appliance or opening of the housing has no significant effect on the safety. Nevertheless, it is possible that

BLUEPALM

leaking refrigerant may accumulate inside the enclosure and flammable atmosphere will be released when the enclosure is opened.

Ventilated enclosure – (see Clause GG.4) Safety of the appliance depends on ventilation of the housing. Switching off the appliance or opening of the enclosure has a significant effect on the safety. Care should be taken to ensure a sufficient ventilation before.

Ventilated room – (see Clause GG.5) Safety of the appliance depends on the ventilation of the room. Switching off the appliance or opening of the housing has no significant effect on the safety. The ventilation of the room shall not be switched off during repair procedures. Information about the concept of sealed components and sealed enclosures according to IEC 60079-15:2010.

Information about the correct working procedures:

1. Commissioning

o Ensure that the floor area is sufficient for the refrigerant charge or that the ventilation duct is assembled in a correct manner.
o Connect the pipes and carry out a leak test before charging with refrigerant.
o Check safety equipment before putting into service.

2. Maintenance

o Portable equipment shall be repaired outside or in a workshop specially equipped for servicing units with flammable refrigerants.
o Ensure sufficient ventilation at the repair place.
o Be aware that malfunction of the equipment may be caused by refrigerant loss and a refrigerant leak is possible.
Discharge capacitors in a way that won't cause any spark. The standard procedure to short circuit the capacitor terminals usually creates sparks.
o Reassemble sealed enclosures accurately. If seals are worn, replace them.
o Check safety equipment before putting into service.

3. Repair o Portable equipment shall be repaired outside or in a workshop specially equipped for servicing units with flammable refrigerants.

o Ensure sufficient ventilation at the repair place.
o Be aware that malfunction of the equipment may be caused by refrigerant loss and a refrigerant leak is possible.
o Discharge capacitors in a way that won't cause any spark.
When brazing is required, the following procedures shall be carried out in the right order:

  • Remove the refrigerant. If the recovery is not required by national regulations, drain the refrigerant to the outside. Take care that the drained refrigerant will not cause any danger. In doubt, one person should guard the outlet. Take special care that drained refrigerant will not float back into the building.
  • Evacuate the refrigerant circuit.
  • Purge the refrigerant circuit with nitrogen for 5 min.
  • Evacuate again.
  • Remove parts to be replaced by cutting, not by flame.
    • Purge the braze point with nitrogen during the brazing procedure.
  • Carry out a leak test before charging with refrigerant.
  • Reassemble sealed enclosures accurately. If seals are worn, replace them. ☐ Check safety equipment before putting into service.

4. Decommissioning o If the safety is affected when the equipment is put out of service, the refrigerant charge shall be removed before decommissioning.

o Ensure sufficient ventilation at the equipment location.
o Be aware that malfunction of the equipment may be caused by refrigerant loss and a refrigerant leak is possible.
o Discharge capacitors in a way that won't cause any spark.
o Remove the refrigerant. If the recovery is not required by national regulations, drain the refrigerant to the outside. Take care that the drained refrigerant will not cause any danger. In doubt, one person should guard the outlet. Take special care that drained refrigerant will not float back into the building.

o Evacuate the refrigerant circuit.
o Purge the refrigerant circuit with nitrogen for 5 min.
o Evacuate again.
o Fill with nitrogen up to atmospheric pressure.
o Put a label on the equipment that the refrigerant is removed.

5. Disposal o Ensure sufficient ventilation at the working place.

BLUEPALM

Remove the refrigerant. If the recovery is not required by national regulations, drain the refrigerant to the outside. Take care that the drained refrigerant will not cause any danger. In doubt, one person should guard the outlet. Take special care that drained refrigerant will not float back into the building.

o Evacuate the refrigerant circuit.
o Purge the refrigerant circuit with nitrogen for 5 min.
o Evacuate again.
o Cut out the compressor and drain the oil.

Transportation, marking and storage for units that employ flammable refrigerants

Transport of equipment containing flammable refrigerants

Attention is drawn to the fact that additional transportation regulations may exist with respect to equipment containing flammable gas. The maximum number of pieces of equipment or the configuration of the equipment, permitted to be transported together will be determined by the applicable transport regulations.

Marking of equipment using signs

Signs for similar appliances used in a work area generally are addressed by local regulations and give the minimum requirements for the provision of safety and/or health signs for a work location.

All required signs are to be maintained and employers should ensure that employees receive suitable and sufficient instruction and training on the meaning of appropriate safety signs and the actions that need to be taken in connection with these signs.

The effectiveness of signs should not be diminished by too many signs being placed together. Any pictograms used should be as simple as possible and contain only essential details.

Disposal of equipment using flammable refrigerants See national regulations.

Storage of equipment/appliances

The storage of equipment should be in accordance with the manufacturer's instructions. Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.

DECLARATION OF CONFORMITY

This declaration of conformity is issued under the sole responsibility of the manufacturer.

Schuss Home Electronic GmbH

Scheringgasse 3

1140 Wien, AUSTRIA

Declares, that the product

Manufacturer

Hersteller

BC12KL2201FW BPPAC12000FW

is conformity with following directives, norms and/or regulations:

DIRECTIVE 2014/53/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCILof 16 April 2014

on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999/5/EC EU L 153/62 22.5.2014

Article 3.1(a) Safety:

EN 60335-2-40:2003+A11:2004+A12:2005+A1:2006+A2:2009+A13:2012

EN 60335-1:2012+A11:2014+A13:2017+A1:2019+A14:2019+A2:2019

EN62233: 2008

Article 3.1(a) Health:

EN 50665:2017, EN 62311:2020

Article 3.1(b) EMC:

EN 301 489-1 V2.2.3

EN 301 489-17 V3.2.4

EN 55014-1:2017+A11:2020, EN 55014-2:2015

EN IEC 61000-3-2:2019, EN IEC 61000-3-3: 2013+A1:2019

Article 3.2 Radio:

EN 300 328 V2.1.1

EMC Directive (EMC): 2014/30/EU Directive of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility; Official Journal of the EU L96, 29/03/2014, p. 79–106

Low Voltage Directive (LVD):2014/35/EU Directive of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits; Official Journal of the EU L96, 29/03/2014, p. 357–374

Ökodesign-Richtlinie Energy-Related-Products-Directive (ErP)2009/125/EC;

Official Journal EU L285/10-35 (31.10.2009) and associated regulation 2015/1188

RoHS Directive: 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment; Official Journal of the EU L174, 1/07/2011, p. 88–110

Reach SVHC(EC)NO. 1907/2006 Schuss Home Electronic GmbH hereby confirms that in the products we supply, there are no substances of very high concern (SVHC) in the candidate list (last ECHA update from June 14, 2023, 235 substances) above 0.1% in accordance with Article 33 of the REACH Regulation (EC) No .1907/2006 are included.

Place and date of issue:

Vienna, 2025-11-20

BLUEPALM BPPAC12000FW - Article 3.2 Radio: - 1

Senior product and purchasing manager i.V.

Name, Funktion / name, function

Unterschrift / signature

Declaration reference:

SCHUSS HOME ELECTRONIC GMBH

Scheringgasse 3, 1140 Wien, AUSTRIA

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : BLUEPALM

Model : BPPAC12000FW

Category : Air Conditioning