Duronic SADT2 - Lamp

SADT2 - Lamp Duronic - Free user manual and instructions

Find the device manual for free SADT2 Duronic in PDF.

📄 75 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Duronic SADT2 - page 7
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Light therapy lamp
Brand Duronic
Model SADT2
Dimensions (L x W x H) 260 x 150 x 17 mm
Weight 500 g
Power supply 12 V DC, 1 A
Light intensity > 10,000 lux at 10 cm
Light elements LED
Treatment surface Approx. 400 cm²
Recommended usage distance 20 to 30 cm from eyes
Recommended exposure time (high intensity at 30 cm) Approx. 2 hours
Recommended exposure time (low intensity at 30 cm) Approx. 2.5 hours
Main function Treatment of seasonal affective disorder (SAD)
Intensity adjustment Two levels (high/low) by pressing the switch
Maintenance and cleaning Damp cloth once a month, unplug before
Storage Dry place, out of reach of children
Protection rating IP20
Electrical class Class II
Warranty 1 year (Shine-Mart Ltd)
Included accessories Stand, power adapter

Frequently Asked Questions - SADT2 Duronic

What is the ideal distance between the lamp and my eyes?
The recommended distance is 20 to 30 cm. The closer you are, the shorter the required exposure time.
How long should I use the lamp each day?
About 1 to 2 hours depending on intensity and distance. For example, at 30 cm and high intensity, expect 2 hours.
Can I read or work while using it?
Yes, you can read, write, make calls, or work. Ensure to maintain the recommended distance.
What are the possible side effects?
Headaches, eye strain, insomnia, or nausea may occur. If discomfort, move the lamp away or take a break.
How to clean the lamp?
Turn off and unplug the device. Clean with a damp cloth (no water inside). Possible once a month.
Is the lamp suitable for everyone?
No. Consult a doctor if you suffer from severe depression, eye problems, high blood pressure, or if you take certain medications.
Can I use the lamp in a bathroom?
No, avoid humid environments. Do not immerse or use near a shower.
What to do if the lamp does not turn on?
Check that the switch is pressed and the adapter is properly plugged. If the problem persists, contact customer service.
How to replace the LEDs?
The LEDs are not user-replaceable. In case of failure, contact Duronic or your retailer.
Does the lamp emit UV?
No, it simulates daylight without UV rays. The light intensity is >10,000 lux without UV.

User questions about SADT2 Duronic

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Lamp in PDF format for free! Find your manual SADT2 - Duronic and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SADT2 by Duronic.

USER MANUAL SADT2 Duronic

Creative Consumer Products

Duronic SADT2 - 1

natural_image White electronic device with a green indicator button and 'DURONIC' branding (no additional text or symbols visible)

SADT2 - SAD Light

Duronic SADT2 - 2

Duronic SADT2 - 3

Duronic SADT2 - 4

Duronic SADT2 - 5

Duronic SADT2 - 6

Contents

English Manual 2

Instructions for Use

Congratulations on the purchase of your new "SAD Light". The product will offer many years of reliable usage if handled correctly. Please keep your receipt, these instructions and the original packaging safe in case of future requirement.

Please read the instructions carefully to gain the most benefit from your new "SAD Light", although the usage guidelines in this document do not replace the advice of your qualified medical advisor.

Intended Use:

Medical intended use of this appliance is to treat the symptoms of SAD (seasonal affective disorder) or winter depression. "SAD Light" is intended to boost people's energy levels, to adjust circadian rhythms and make people feel more awake.

"SAD Light" is safe and medically proven to provide relief from the symptoms of SAD.

How does the "SAD Light" work?

In autumn and winter, the seasons with the least sunlight because of shorter days the lack of sunlight and a problem with certain brain chemicals stops the hypothalamus working properly. The lack of light is thought to affect the production of the hormone melatonin (that makes you sleepy).

"SAD Light" uses bright lights to simulate the sunlight during the darker autumn and winter, whilst eliminating the dangerous UV rays contained in sunlight. The additional light helps adjust the levels of melatonin that can help the symptoms of SAD.

Seasonal Affective Disorder:

Seasonal Affective Disorder (SAD) as known as winter depression or winter blues It may cause people to:

• Feel low, restless and fatigued
• Have trouble concentrating
- Lack energy

Need more sleep

Less active than normal

Symptoms occur during the same season each year.

Most people with SAD start to have symptoms during winter, and feel better in the summer.

Contradiction

The following conditions may be in contradiction for use of this appliance:

  • suffer(ed) from severe depression
  • recent eye surgery or a diagnosed eye condition whereby doctor has advised you to avoid bright light
    • on specific medication (i.e. certain antidepressants, psychotropic drugs or malaria tablets);
    • have high blood pressure with vitreous hemorrhage;
  • skin sensitive to light, such as systemic lupus erythematosus

Always consult your doctor before your start using this appliance if you have any of the above conditions.

Possible Side effects:

Eyestrain• Headaches

- Sleeping

Problems

Nausea

Measures to avoid, minimize or alleviate these side effects:

  • Increase the treatment distance
  • Avoid using the appliance during the late evening or before sleep
  • Stop using the appliance for a few days to make the side effects disappear and then try again.

Safety and performance standards

The “SAD Light” has been designed and manufactured to conform to the highest standards of safety and performance including electromagnetic compatibility (EMC).

The "SAD Light" conforms to the applicable requirements of the following:

CE 0123

This appliance meets the requirement of

Medical Device Directive 93/42/EEC for medical appliances.

Emissions Test StandardCompliance
RF emissions CISPR 11Group 1
RF emissions CISPR 11Class B
Harmonic emissions IEC 61000-3-2Class A
Voltage fluctuations/ flicker emissions IEC 61000-3-3Comply
Guidance and manufacturer's declaration - electromagnetic Immunity
Radiated RF IEC61000-4-3 (Test specification for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment)Test Frequency (MHz)Band (MHz)Service Modulation ModulationModulation Modulation(W)Distance (m)Immunity Test Level (V/m)
385 380-390TETRA 400Pulse modulation 18Hz1.8 0.3 27
450 430-470GMRS 460 FRS 460FM +5kHz deviation 1kHz sine2 0.3 28
710 745 780704 - 787LTE Band 13, 17Pulse modulation 217Hz0.2 0.3 9
810 870 930800 - 960GSM 800/900 TETRA 800, iDEN 820 CDMA 850 LTE Band 5Pulse modulation 18Hz2 0.3 28
1720 1845 19701700 - 1990GSM 1800 CDMA 1900 GSM 1900 DECT; LTE Band 1 3,4,25 UMTSPulse modulation 217Hz2 0.3 28
2450 240-2570Bluetooth WLAN 802.11 b/g/n RFID2450 LTE Band 7Pulse modulation 217Hz2 0.3 28
5240 5240 57855100 - 5800WLAN 802.11 a/nPulse modulation 217Hz0.2 0.3 9
Immunity Test Standard IEC60601-1-2 Test Level Compliance Level
Electrostatic discharge (ESD)IEC 61000-4-2±8kV contact±2kV, ±4kV, ±8kV,±15kV air±8kV contact±2kV, ±4kV, ±8kV,±15kV air
Electrical fast transient/burstIEC 61000-4-4±2kV, for power supply lines±1kV signal input/ output 100kHzrepetition frequency±2kV, for power supply linesNot applicable100 kHz repetition frequency
Surge IEC 61000-4-5 ±0.5kV, ±1kV differential lines±0.5kV, ±1kV,±1kV common mode±0.5kV, ±1kV differential linesNot Applicable
Voltage dips,interruptions and variations onpower supply input linesIEC 61000-4-110% UT; 0.5 cycle. At 0°, 45°,90°, 135°, 180°, 225°, 270° and315°.0% UT; 1 cycle and 70% UT;25/30 cycles; Single phase:at 0°.0% UT; 250/300 cycle0% UT; 0.5 cycle. At 0°, 45°,90°, 135°, 180°, 225°, 270° and315°.0% UT; 1 cycle and 70% UT;25/30 cycles; Single phase: at0°. 0% UT; 250/300 cycle
Power frequency (50/60 Hz)magnetic fieldIEC 61000-4-830 A/m50Hz/60Hz30 A/m50Hz/60Hz
Conducted RF IEC 61000-4-6 3 V0,15 MHz – 80 MHz6 V in ISM and amateur radiobands between 0,15 MHz and80 MHz80 % AM at 1 kHz3 V0,15 MHz – 80 MHz6 V in ISM and amateur radiobands between 0,15 MHz and80 MHz 80 % AM at 1 kHz
Radiated RF IEC 61000-4-3 10 V/m80 MHz – 2,7 GHz 80 % AM at1 kHz10 V/m80 MHz – 2,7 GHz 80 % AM at1 kHz

The following symbols appear in this manual, on the "SAD Light" or on its accessories:

Duronic SADT2 - Safety and performance standards - 1Warning instruction indicating a risk of injury or damage to healthDuronic SADT2 - Safety and performance standards - 2Read operating instructions before use
Duronic SADT2 - Safety and performance standards - 3Safety note indicating possible damage to the appliance/ acces-Duronic SADT2 - Safety and performance standards - 4Caution: Consult accompanying documents
Duronic SADT2 - Safety and performance standards - 5Specifies serial number of the “Daylight”Duronic SADT2 - Safety and performance standards - 6Class II Equipment
Duronic SADT2 - Safety and performance standards - 7OFF/ ONDuronic SADT2 - Safety and performance standards - 8Date of Manufacture
Duronic SADT2 - Safety and performance standards - 9Authorized Representative in the European CommunityDuronic SADT2 - Safety and performance standards - 10Manufacturer
Duronic SADT2 - Safety and performance standards - 11Ingress Protection RatingDuronic SADT2 - Safety and performance standards - 12Keep Dry

Notes

Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.

- Do not use this appliance in wet surroundings (e.g. in the bathroom or near a shower). Do not immerse appliance in water or any other liquid.

- Before use, ensure that all packaging materials are removed and that there is no visible damage to the appliance or accessories.

- When in doubt, do not use the appliance and contact your dealer or the customer service address provided.

- The adaptor contains a transformer. Do not cut off the adaptor to replace it with another plug, as this can cause a hazardous situation.

• This appliance is only intended for use on the human body.

- Close supervision in necessary when this appliance is used by,

• or near children or invalids.

• Children should be supervised to ensure that they do not play with the appliance.

- There is no need for any special training for this appliance.

- Keep the cord away from hot objects and open flames.

- Connect the appliance only to the mains voltage listed on the type plate.

• Always remove the mains plug and let the appliance cool off before you touch it.

- Do not touch the appliance with wet hands while it is plugged in; do not allow any water to be sprayed onto it.

- The appliance must be operated only when it is completely dry.

- Protect the appliance from strong impacts.

- Avoid pulling the cord when removing the plug from the socket. Instead, hold the plug.

- If the adaptor, cord or the appliance is damaged, contact customer service or the dealer, since special tools are needed to make repairs.

- Never try to repair the appliance yourself.

- Disconnection from the power supply network is only guaranteed when the mains part is unplugged.

- This appliance is not suitable for use in the presence of flammable anesthetic mixtures with air or with oxygen or nitrous oxide.

• This appliance requires no calibration, preventive inspection and maintenance.

- This appliance is not repairable and contains no user serviceable parts.

• The operator shall not touch the appliance and the patient simultaneously.

• The appliance is protected against unauthorized use.

- Do not modify this appliance without authorization of the manufacturer.

- If this appliance is modified, appropriate inspection and testing must be

• conducted to ensure continued safe use of the equipment.

- This appliance is not intended for commercial or clinical use, but only for individual, private household use.

- If you are taking medication such as pain relievers, antihypertensives or antidepressants, consult your doctor before using this appliance.

• People with retinal diseases as well as diabetics need to be examined by an ophthalmologist before using this appliance.

- Please do not use if you have an eye disease such as cataracts, glaucoma, diseases of the optic nerve in general and inflammation of the vitreous humour.

• If you have health concerns of any kind, contact your general practitioner.

- Use of this appliance adjacent to or stacked with other device should be avoided because it could result in improper operation. If such use is necessary, this appliance and the other device should be observed to verify that they are operating normally. If the appliance does not light on or flickering, it means that the appliance is not operating normally.

- Don't near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high.

- Do not change any cable without authorization of the manufacturer. Use of cables other than those specified or provided by the manufacturer of this appliance could result in increased electromagnetic emissions or decreased electromagnetic immunity of this appliance and result in improper operation.

- Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm to any part of this appliance, including power cable. Otherwise, degradation of the performance of this equipment could result.

- If the appliance does not light on or flickering due to the electromagnetic disturbances, do not use it and try to place the appliance in other location.

- For maintaining the basic safety and essential performance with regard to electromagnetic disturbances for the expected service life, please precaution to take if the use location is near (e.g. less than 1.5 km from) from AM, FM or TV broadcast antennas.

Maintenance and Repairs

  • Avoid exposing the screen to direct sunlight, spotlight or any other heat source.

- Do not use alcohol or ammonia base liquid to clean the screen. The cleaning information provided in the section “Cleaning and Storage”.

- Please do not attempt to repair the appliance yourself.

This could result in serious injuries.

Failure to observe this regulation shall void the warranty.

- If this appliance is damaged in any way or it is not working, it should not be operated.

Please try to fix the problem according to FAQ table.

- If the problem is still not resolved, please contact customer service or the dealer, since special tools are needed to make repairs.

Never try to repair the appliance yourself.

Unit Description
Duronic SADT2 - Maintenance and Repairs - 1
1. Light screen
2. On/off button
3. Stand hole
4. Stand
5. Socket for appliance plug
6. Stand storage cavity

Installation

  1. Remove the stand from the stand storage cavity.
  2. Insert the end of stand into the hole on the back of appliance.
  3. Place the appliance on a solid surface approximately
    20 - 30cm from your eyes, the light must bathe your face from the side.
  4. Connect the appliance only to the mains voltage listed on the type plate.
  5. Push the plug completely into the mains socket.
  6. Ensure that there is a socket near the place where the appliance will stand.
  7. Lay the mains cable in such a way that no one can trip over it.

DURONIC

Operation

Before use, please check the appliance for damage or faults. If you notice any damage or faults on the appliance, do not use it and contact customer services or your supplier.

1. Turning on

Press the ON/OFF button once of the appliance to turn on with higher intensity.

2. Choosing the light intensity

To choose a lower intensity, press the ON/OFF button again.

3. Taking the light

You can read, write, make telephone calls or work while you use the appliance. When using the appliance, try to maintain the recommended distance of 20 - 30 cm between your eyes and the appliance.

Usage guidelines are as follows:

Distance Duration of higher intensityDuration of lower intensity
30cm Approx. 2hours /
20cm Approx. 1hour Approx. 2 hours

In effect, the closer you are to the source of light, the less time you need to use it.

- Do not look directly into the light continuously! Some eye pain or mild headaches may be experienced during initial sessions but these should pass. If in doubt just lower your treatment times until comfortable again.

- Do not leave the appliance unattended in the duration.

4. Enjoying light over longer periods

During the darkest period of the year, repeat the treatment for at least 7 consecutive days, or longer, depending on your individual requirements.

5. Switching off

Press the ON/OFF button of the appliance to switch off.

DURONIC

Cleaning and Storage

  • Before you clean the appliance, always switch it off,
  • unplug it and let it cool off.
  • Do not touch the appliance with wet hands.
  • Clean using a damp cloth,

to which you can apply a little detergent if necessary.

  • Do not let water run into the appliance or spill water onto the appliance.
  • Cleaning can be done once per month.

When this appliance is not being used,

it should be stored in a dry location out of reach of children.

Do not keep the appliance connected to a power source.

Follow the storage instructions provided in the section "Technical Specification".

Disposal

Duronic SADT2 - Disposal - 1

natural_image Symbol of a trash bin crossed with no text or labels, accompanied by a black rectangular block below (no readable text or symbols)

Please note that this appliance is marked with the WEEE symbol on the left.

This means that this appliance must not be disposed of together with ordinary household waste, as electrical and electronic waste must be disposed of separately.

FAQ

ProblemPossible Causes Solutions
Device does not light upOn/ Off button switched offSwitch on the on/off button
No Power Connect the main plug correctly
No Power The main cable is defective. Contact customer services or your retailer
LEDs have reached the end of its service lifeIf you need to have the appliance repaired, contact customer service or an authorized dealer.
LEDs faulty

Technical Specification

Model LND018915V2
Dimension (WHD) 260 x 150 x 20mm
Weight 500g
Lighting elements LEDs
Power DC12V, 1A
Light intensity 10,000 lux in 10 cm
Mains connection 12V DC, 1.0A, only in adaptor model:HP24A-120100-AdV or HP24A-120100-AdB
Operating Environment 0 to +40 oC, and 30% to 90% relative humidity Atmospheric pressure:700-700-106
Storage and Transport Environment -10 to +60 oC, and 30% to 90% relative humidity Atmospheric pressure:700-1060hPa
Product Classification Class II equipmentNo applied partProtection against ingress of water:IP21Not category AP / APG equipmentMode of operation:Continuous operation
Maximum length of power cord 2000 mm
Location of emission aperture Screen
Treatment area Around 400 cm2
Risk Group of light source equipmentExempt Group
Product Service Life5 years

Subject to technical modification.

Maximum output of optical radiation for the “SAD Light”:
Radiance Output Risk group classified by IEC 60601-2-57:2011Max. value
EUVA: Eye UV-A ExemptGroup 1.0×10-4 W·m-2
ES: Actinic UV skin & eyeExempt Group 1.0×10-4 W·m-2
EIR: Infrared radiation hazard exposure limits for the eyeExempt Group 1.0×101 W·m-2
EH: Thermal hazard for the skinExempt Group 2.0×101 W·m-2
LB: Blue light Exempt Group5.0 ×101 W·m-2·sr-1
LR: Retinal thermal ExemptGroup 5.0 ×101 W·m-2·sr-1

Contact information

Model Number: SADV1

Brand: Duronic

Details:

Shine-mart Ltd, trademark owners of Duronic products.

1 Spilsby Road

Romford, RM3 8SB,

United Kingdom

The "SAD Light" is manufactured by:

Zero-Plus International Limited

Room 1004, 10/F., Join-In Hang Sing Centre, 71-75 Container Port Road,

Kwai Chung, New Territories, Hong Kong

European Authorised Representative:

Globalmind Consumer Electronics GmbH Ernst-Mantius-Str.11,

21029 Hamburg,

Germany

If this appliance is damaged in any way or it is not working and you cannot find the answer to your question in FAQ. Please contact customer service or the retail-er for assistance.

DURONIC

Warranty

1 Year Guarantee from Shine-Mart Ltd, Trademark owners of Duronic Products. NOTE: THESE STATEMENTS DO NOT AFFECT YOUR STATUTORY RIGHTS AS A CONSUMER

This product has been manufactured under the strictest or quality control procedures, and using the highest quality of materials, to ensure excellent performance and reliability. It will give very good and long lasting service, provided it is properly used and maintained. The product is guaranteed for 1 years from the date of original purchase. If any defect arises due to a faulty materials or poor workmanship, the faulty product must be returned to the original place of purchase. Refund or replacement is at the discretion of that company. Duronic Products are offered with a 1 year guarantee under the following conditions:

  1. he product must be returned to the retailer with original proof of purchase.
  2. he product must be installed and used in accordance with the instructions contained in this operating manual.
  3. t must be used only for domestic purposes.
  4. t does not cover wear and tear, malicious damage, misuse, neglect, inexpert repairs or consumable parts.
  5. hine-Mart Ltd has no responsibilities for accidental or consequential loss or damage.
  6. hine-Mart Ltd are not liable to carry out any type of servicing work, under the guarantee
  7. alid in the UK only

Duronic SADT2 - Warranty - 1

This product is fitted with CE:1363 plug and fuse Imported by Shine-Mart Ltd, RM3 8SB

Duronic SADT2 - Warranty - 2

Information on waste Disposal for Consumers of Electrical & Electronic Equipment.

This mark on a product and/or accompanying documents indicates that when it is to be disposed of, it must be treated as Waste Electrical & Electronic Equipment, (WEEE).

Any WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and recycling of the materials used. For proper treatment, recovery and recycling; please take all WEEE marked waste to your Local Authority Civic waste site, where it will be accepted free of charge.

If customers dispose of Waste Electrical & Electronic Equipment correctly, they will be helping to save valuable resources and preventing any potential negative effects upon human health and the environment, of any hazardous materials that the waste may contain.

Follow Us

Duronic SADT2 - Follow Us - 1

duronic.com

Duronic SADT2 - Follow Us - 2

duronic

Duronic SADT2 - Follow Us - 3

@duronicmedia

Duronic SADT2 - Follow Us - 4

Duronic

Duronic SADT2 - Follow Us - 5

@duronicmedia

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Duronic

Model : SADT2

Category : Lamp