USER MANUAL CoverOne 1500 AUT T.I.P.
EC declaration of conformity We, T.I.P. Technische Industrie Produkte GmbH, Siemensstr. 17, D-74915 Waibstadt, declare in our sole responsibility that the products identified below comply with the basic requirements imposed by the EU directives specified below including all subsequent amendments: 2014/35/EU, 2014/30/EU, 2011/65/EU.
1. General safety information
Please read through these operating instructions carefully and make yourself conversant with the control elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of the non-observance of instructions and provisions of the present operating instructions. Any damage caused as a result of the non-observance of the instructions and regulations contained in the present operating instructions shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand them on together with the device should you ever dispose of it. Persons not conversant with the contents of these operating instructions must not use this device. The pump must not be used by children. The pump may be used by persons with reduced physical, sensory or mental capabilities or lack of experience and / or knowledge if they have been supervised or instructed in the safe use of the equipment and have understood the resulting hazards. Children are not allowed to play with the device. Keep the appliance and its cord out of reach of children. The pump must not be used when people or animals are in the water. The pump must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Notes and instructions with the following symbols require particular attention:
Any non-observance of these instructions involves the danger of bodily harm to people and/or damage to property.
Any non-observance of this instruction bears the risk of an electrical shock which may cause damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be informed immediately, at the latest within 8 days after the date of purchase.
This device from T.I.P. is a highly efficient electric pump for pumping clear, clean or moderately dirty water which contains solids up to the maximum size specified in the technical data. This product is intended for private use in the home area and not for commercial or industrial purposes or for continuous circulating.
The pump is not suited to discharge saltwater, faces, inflammable, etching, explosive or other hazardous liquids. Please observe the max. temperature of the liquids to be discharged stated in the technical data.
Inside the pump, lubricants are used which may contaminate the liquids being discharged in case of any improper operation or damage of the device. The lubricants used are biologically degradable and non- hazardous to health.
1,6 m Max. submersion depth 1 m Max. size of the solids being pumped 2 mm Max. fluid temperature (T max
The values were determined with free, unreduced outlet.
4. Scope of delivery
The scope of the delivery of this product includes: One pump with connection cable, one connection port, one operating manual. Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional accessories may be necessary (please refer to the chapters titled "Installation" and “How to order spare parts“). If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an environmental-friendly manner.
During the entire process of installation, the device must not be connected to the electrical mains.
The pump and the entire connection system have to be protected from frost.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and cause considerable damage. If required, please use a suitable sealant to make the installation airtight. When tightening threaded connections, please do not apply excessive force which may cause damage. When laying the connection pipes, you should make sure that the pump is not exposed to any form of weight, vibration or tension. Moreover, the connection lines must not contain any kinks or an adverse slope.
5.2. Installation of the pressure line This pump is equipped with a garden hose adapter as standard. Connect the garden hose to the pump's adapter with a quick coupling (Fig. 1) to drain the waste water from the pool. This allows the pump to be mounted and disassembled quickly and easily.
Fig. 1 To avoid flow losses, it is advisable to use a pressure line with a diameter equal to that of the pump pressure connection as a minimum. Use a flexible hose suitable for this purpose, e.g. a commercially available garden hose or similar, as a pressure line.
5.3. StatiPositioning the pump
Place the pump in the deepest part of the water on your pool cover. The pump must be installed in a horizontal position. Point the open end of the pool's garden hose away from the pool. Connect the pump to the electrical circuit (Fig.2). In addition, when positioning the pump, make sure that the maximum immersion depth specified in the technical data is not exceeded. During subsequent operation, the water level will then be reduced to the minimum suction level (Fig. 3).
6. Electrical connection
The unit is equipped with a mains connection cable and a mains plug. It must only be replaced by qualified staff to avoid any danger. Please do not use the mains connection cable to carry the pump, and do not use this cable to pull off the plug from the socket, either. Protect the mains connection cable and mains plug from heat, oil or sharp edges.
The values stated in the technical details have to correspond to the mains voltage. The person responsible for the installation has to make sure that the electrical connection is earthed in compliance with the applicable standards.
The electrical connection has to be equipped with a highly sensitive residual current circuit- breaker (FI switch): ∆ = 30 mA (DIN VDE 0100-739).
If extension cables are used, their cross-section must not be smaller than that of rubber- sheathed cables of the H05RN-F (3 x 0.75 mm²) short code. The mains socket and the plug- and-socket elements have to be in splash water-proof design.
7. Putting into operation
Please make sure that the electrical plug connections are in the flood-proof area.
As long as the device is connected to the electrical mains, one must never reach with one’s hands into the opening of the pump.
Please inspect the pump visually prior to each use. This applies in particular to the mains connection line and the mains plug. Make sure that all screws are firmly tightened, and verify the perfect condition of all connections. A damaged pump must not be used. In any case of damage, the pump has to be inspected by qualified service staff. Each time the pump is put into operation, please make sure that the pump is set up securely and firmly standing. To put the unit into operation, please plug the mains plugs into a 230V AC socket. If the water level has reached or exceeded the cut-in level, the pump will start to run immediately. To stop the operation of the pump, please pull the mains plug off the socket. The electrical pumps are equipped with an integrated thermal motor protection feature. In the case of overload, the motor will switch off independently and on again after cooling down. For possible causes and their elimination, please refer to the “Maintenance and troubleshooting” section.
8. Maintenance and troubleshooting
Prior to carrying out any maintenance work, the pump must be separated from the electrical mains. If you fail to separate the unit from mains, there is a risk of an inadvertent start of the pump.
We decline any liability for damage caused by inappropriate repair attempts. Any damage caused by inappropriate repair attempts will avoid all warranty claims. Observing the conditions of use and the ranges of application of the present device will reduce the risk of possible operational malfunction and contribute to extend the lifetime of your unit. Sand and other abrasive matters contained in the liquid discharged will speed up the process of wearing and tearing and accelerate the drop in performance. If the unit is operated properly, it will not require any maintenance. Where applicable, you may clean the hydraulic part from sediments and dirt. This can be done by counter-flushing the unit with clear water using a hose to be connected through the pressure port of the pump. This pump is additionally equipped with a filter mat, which prevents dirt from clogging the pump chamber and possibly damaging it. The filter insert should be cleaned regularly – depending on the degree of soiling. Water left in the pump may freeze in case of frost and thus cause considerable damage. Therefore, the pump must be removed from the liquid being discharged and fully drained when temperatures are below the freezing point of the liquid. Please store the pump in a dry, frost-protected place. In the case of malfunction, you should first of all check whether it was caused by an operating error or some other reason which cannot be attributed to a defect of the device - for instance a power failure. The list below shows some possible malfunctions of the device, possible causes and tips on their elimination. All the measures referred to may only be carried out with the pump being separated from the electrical mains. If you yourself feel unable to eliminate any of these malfunctions, please contact the customer service department or your point of sales. Any repair beyond the scope specified below must only be performed by qualified staff. Please bear in mind that all warranty claims will become void in the case of damage caused by inappropriate repair attempts, and that we decline any liability for any ensuing damage.
MALFUNCTION POSSIBLE CAUSE ELIMINATION
discharging any liquid, the motor is not running.
2. Thermal motor protection feature has
3. The Motor is defective.
4. The pump wheel is blocked.
5. The floating switch is defective.
1. Please use a device complying with GS (German
technical supervisory authority) to check for the presence of voltage (safety information to be observed!). Please verify the correct position of the plug.
2. Separate the pump from the electrical mains,
allow the system to cool down, eliminate cause.
3. Please contact the customer service department.
4. Eliminate blocking of pump wheel.
5. Please contact the customer service department.
2. The motor is running,
but the pump is not discharging any liquid.
1. The intake openings are clogged.
2. The pressure line is clogged.
3. Air penetrates into the pump body.
4. The min. suction level was fallen short of;
possibly motion of floating switch restricted, floating switch defective.
1. Remove possible congestion.
2. Remove possible congestion.
3. Start pump several times so that the entire air will
4. Make sure that the minimum suction level is not
fallen short of; if necessary, make sure that it can move freely; in the case of a defective floating switch, please contact customer service.
discharged by pump is inadequate.
3. Please contact the customer service department.
4. The pump does not cut
1. Floating switch cannot move freely.
2. Floating switch defective.
1. See that floating switch can move freely.
2. Please contact the customer service department.
The present device was manufactured and inspected according to the latest methods. The seller warrants for faultless material and workmanship in accordance with the legal regulations of the country in which the device was purchased. The warranty period begins with the day of the purchase and is subject to the provisions below: Within the period of warranty, all defects which are to be attributable to defective materials or manufacturing will be eliminated free of charge. Any complaints are to be reported immediately upon their detection. The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third parties. Damage resulting from improper handling or operation, incorrect setting-up or storage, inappropriate connection or installation or Acts of God or other external influences are excluded from warranty. Parts being subject to wear and tear, such as the pump wheel (impeller) and mechanical shaft seals are excluded from warranty. All parts were manufactured using maximum care and high-quality materials and are designed for a long lifecycle. It should be understood, however, that the wear and tear depends on the kind of use, the intensity of use and the internals of maintenance. Complying with the installation and maintenance information contained in the present operating instructions will therefore considerably contribute to a long lifecycle of these wearing parts. In case of complaints, we reserve the option of repairing or replacing the defective parts or replace the entire device. Replaced parts will pass into our property. Claims for liquidated damages are excluded unless they are caused by willful acts or negligence on the side of the manufacturer. The warranty does not provide for any claims beyond those referred to above. The warranty claim has to be evidenced by the purchaser in the form of the submission of the sales receipt. The present warranty commitment is valid in the country in which the device was purchased. Please note:
1. Should your device fail to function properly, please verify first whether an operating error or another cause is
present which cannot be attributed to a defect of the device.
2. In case you have to take or send in your defective device for repair, please be sure to enclose the following
documents: − Sales receipt (sales slip). − A description of the occurring defect (a description as accurate as possible will expedite the repair work).
3. In case you have to take or send in your defective device for repair, please remove any attached parts which
do not belong to the original condition of the device. If any attached parts of this kind should be missing upon the return of the device, we shall not be liable for them.
10. How to order spare parts
The fastest, most simple and cheapest way of ordering spare parts is through the internet. On our website www.tip-pumpen.de you will find a convenient spare part shop where you can order spare parts with just a couple of clicks. In addition, this is also the place where we publish comprehensive information and valuable tips on our products and accessories, introduce new devices and present current trends and innovations in the range of pump technology.
In the case of warranty claims or malfunction, please contact your point of sale. A current operating manual is available as required as a PDF file via e-mail: service@tip-pumpen.de.
For EC countries only Please do not dispose of electrical appliances in the regular domestic waste! According to the European Directive 2012/19/EU regarding waste electrical and electronic equipment and the implementation of that directive into national law, electrical devices have to be collected separately and disposed of in an environmental-suitable manner after the end of their life cycle. Should you have any questions, please contact your local waste disposal company.