Welcome to the Danby family. We are proud of our quality products and we believe in dependable service. We suggest that you read this owner’s manual before plugging in your new appliance as it contains important operation information, safety information, troubleshooting, and maintenance tips to ensure the reliability and longevity of your appliance. You are entitled to the warranty coverage as described in the owner’s manual provided with your new appliance.

1. Please write down your appliance information below. You must keep the original proof

of purchase receipt to validate and receive warranty services.

2. Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION

after fi lling out a product survey, at www.danby.com/support/product-registration/ Need Help?

1. Read your Owner’s Manual for installation help, troubleshooting, and maintenance

2. Visit www.Danby.com to access self-service tools, FAQs and much more by searching

your model number in the search bar.

3. For the Quickest Customer Service, please fi ll out the web form at www.danby.com/

support. Your submission will go directly to an expert on your particular appliance. Our average response times are between 20 minutes and 2 hours, during EST business hours.

4. Call 1-800-263-2629 - please note that during peak hours, hold times can exceed one

Flammable refrigerant used. When maintaining or disposing of the air conditioner, the refrigerant must not be allowed to vent into the open air. WARNING Shows that the appliance uses a fl ammable refrigerant. If the refrigerant leaks and is exposed to an external ignition source, there is a risk of fi re. CAUTION Shows that the operation manual should be read carefully. CAUTION Shows that service personnel should be handling this equipment with reference to the installation manual. CAUTION Shows that the information is available such as the operating manual or the installation manual. Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS! SAFETY PRECAUTIONS WARNING

  • Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock or fi re.
  • Use only the included accessories and parts and specifi ed tools for the installation. Using non-standard parts can cause water leakage, electrical shock, fi re and injury or property damage.
  • Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord is equipped with a three-prong grounding plug to protect against shock. Voltage information can be found on the nameplate of the unit.
  • You unit must be used in a properly grounded wall receptacle. if the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse of circuit breaker needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the unit), have a qualifi ed electrician install the proper receptacle.
  • Install the unit on a fl at, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
  • The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
  • Do not modify the length of the power cord or use an extension cord to power the unit.
  • Do not share a single outlet with other electrical appliances. Improper power supply can cause fi re or electrical shock.
  • Do not install you air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
  • Do not install the unit in a location that may be exposed to combustible fas as this could cause fi re.
  • The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects as this could cause tipping.
  • Do not operate a unit that been dropped or damaged.
  • The appliance with the electric heater shall have at least 1 meter space from combustible materials.
  • Do not touch the unit with wet or damp hands or when barefoot.
  • If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged contact a technician or customer service for assistance.
  • In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
  • You air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store you air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately if this occurs.
  • All wiring must be performed strictly in accordance with the wiring diagram location inside the unit.
  • The units circuit board (PCB) is designed with a fuse to provide over current protection. The specifi cations of the fuse are printed on the circuit board.
  • When the water drainage function is not in use keep the upper and lower drain plugs fi rmly installed in the unit. The drain plugs can be a choking hazard to children. Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS! CAUTION
  • This appliance is not intended for use by persons (including children) whose physical, sensory or mental capabilities may be different or reduced, or who lack experience or knowledge, unless such persons receive supervision or training to operate the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Children must be supervised around the unit at all times.
  • If the power supply cord is damaged it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
  • Prior to cleaning or other maintenance, the appliance must be disconnected from the power supply.
  • Do not remove any fi xed covers. Never use this appliance if it is not working properly or if it has been dropped or damaged.
  • Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not route cord under furniture or appliances. Arrange cords away from traffi c and where it will not be tripped over.
  • Do not operate a unit with a damaged power cord, plug, power fuse or circuit breaker. Discard the unit or return to an authorized service facility for examination and/or repair.
  • To reduce the risk of fi re or electric shock do not use this air conditioner with any solid-state speed control device.
  • The appliance shall be installed in accordance with national wiring regulations.
  • Contact the authorized service technician for repair or maintenance of this unit.
  • Contact the authorized service installer for installation of this unit.
  • Do not cover or obstruct the inlet or outlet grilles.
  • Do not use this product for functions other than those described in this instruction manual.
  • Before cleaning turn off the power and unplug the unit.
  • Disconnect the power if strange sounds, smells or smoke comes from it.
  • Do not press the buttons on the control panel with anything other than your fi ngers.
  • Do not remove any fi xed covers. Never use this appliance if it is not working properly or if it has been dropped or damaged.
  • Do not operate or stop the unit by inserting or pulling out the power cord plug.
  • Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of infl ammable substances or vapour such as alcohol, insecticides, petrol, etc.
  • Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
  • Always contact a qualifi ed person to carry out repairs. If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired.
  • Hold the plug by the head of the power plug when removing it.
  • Turn off the appliance when not in use. Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS! Note about fl uorinated gasses
  • Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specifi c information on the type, the amount and the C02 equivalent in tonnes of the fl uorinated greenhouse gas on some models. Please refer to the relevant label on the unit itself.
  • Installation, service, maintenance and repair of this unit must be performed by a certifi ed technician.
  • Product installation and recycling must be performed by a certifi ed technician. WARNING for using R32 refrigerant
  • Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources for example, open fl ames, an operating gas appliance or an operating electric heater.
  • Do not pierce or burn.
  • Be aware that the refrigerants may not contain an odour.
  • The appliance should be installed, operated and stored in a room with a fl oor area according to the amount of refrigerant to be charged. For specifi c information on the type of gas and the amount, please refer to the relevant label on the unit itself. When there are differences between the label and the manual on the minimum room area description, the description on the label shall prevail.
  • Compliance with national gas regulations shall be observed.
  • Keep ventilation openings clear of obstruction.
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specifi ed for operation.
  • Any person involved with working on the refrigerant circuit should hold a current, valid certifi cate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specifi cation.
  • Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of fl ammable refrigerants.
  • Please follow the instruction carefully to handle, install, clear and service the air conditioner to avoid any damage or hazard. Flammable refrigerant R32 is used within this air conditioner. When maintaining or disposing of the air conditioner the refrigerant must be recovered properly and should not be allowed to discharge to the air directly.
  • No open fi re or device like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the fl ammable refrigerant used.
  • Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
  • Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard. For specifi c information on the type of gas and the amount, please to the relevant label on the unit itself.
  • The appliance shall be stored in a room without continuously operating open fl ames (for example an operating gas appliance) and ignition sources (for example an operating electric heater). Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS! Transport of equipment containing fl ammable refrigerants See transport regulations. Marking of equipment using signs See local regulations. Disposal of equipment using fl ammable refrigerants See national regulations. Storage of equipment / appliances The storage of equipment should be in accordance with the manufacturer’s instructions. Storage of packed (unsold) equipment Storage package protection should be constructed such that the mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations. Information on servicing

1. Checks to the area: Prior to beginning work on systems containing fl ammable refrigerants, safety

checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

2. Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of

a fl ammable gas or vapour being present while the work is being performed.

3. General work area: All maintenance staff and others working in the local area shall be instructed on

the nature of work being carried out. Work in confi ned spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the work area have been made safe by removing all fl ammable material.

4. Checking for the presence of refrigerant: The area shall be checked with an appropriate refrigerant

detector prior to and during work to ensure the technician is aware of potentially fl ammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with fl ammable refrigerants, i.e. non-sparking, adequately sealed and intrinsically safe.

5. Presence of fi re extinguisher: If any hot work is to be conducted on the refrigeration equipment or

any associated parts, appropriate fi re extinguishing equipment shall be available to hand. Have a dry powder or C0

fi re extinguisher adjacent to the work area. Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS!

6. No ignition sources: No person carrying out work in relation to a refrigeration system which involves

exposing any pipe work that contains or has contained fl ammable refrigerant shall use any sources of ignition in such a manner that it may lead to risk of fi re or explosion. All possible ignition sources including cigarette smoking, should be kept suffi ciently far away from the site of installation, repairing, removing and disposal during which fl ammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure there are no fl ammable hazards or ignition risks. No smoking signs shall be displayed.

7. Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking

into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferable expel it externally into the atmosphere.

8. Checks to the refrigeration equipment: Where electrical components are being changed, they shall

be fi t for the purpose and to the correct specifi cation. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using fl ammable refrigerants:

  • The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
  • The ventilation machinery and outlets are operating adequately and are not obstructed.
  • If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
  • Marking to the equipment continues to be visible and legible. Markings and signs that become illegible must be corrected.
  • Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitable protected against being corroded.

9. Checks to electrical devices: Repair and maintenance to electrical components shall include initial

safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include:

  • That capacitors are discharged. This shall be done in a safe manner to avoid possibility of sparking.
  • That no live electrical components and wiring are exposed while charging, recovering or purging the system.
  • That there is continuity of earth bonding. Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS! Repairs to sealed components

1. During repairs to sealed components, all electrical supplies shall be disconnected from the equipment

being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.

2. To ensure that by working on electrical components the casing is not altered in such a way that the level

of protection is affected, particular attention shall be paid to the following:

  • Damage to cables, excessive number of connections, terminals not made to original specifi cation, damage to seals, incorrect fi tting of glands, etc.
  • Ensure the apparatus is mounted securely.
  • Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of fl ammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifi cations. Note: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a fl ammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specifi ed by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak. Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. Detection of fl ammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch or any other detector using a naked fl ame shall not be used. Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS! Leak detection methods The following leak detection methods are deemed acceptable for systems containing fl ammable refrigerants:
  • Electronic leak detectors shall be used to detect fl ammable refrigerants but the sensitivity may not be adequate or may need recalibration. Detection equipment shall be calibrated in a refrigerant-free area. Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
  • Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confi rmed.
  • Leak detection fl uids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper or pipe-work.
  • If a leak is suspected, all naked fl ames shall be removed or extinguished.
  • If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that the best practice is followed since fl ammability is a consideration. The following procedures shall be adhered to:
  • Purge the circuit with inert gas.
  • Purge again with inert gas.
  • Open the circuit by cutting or brazing.
  • The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be fl ushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task.
  • Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fi ll until the working pressure is achieved, then venting to atmosphere and fi nally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the fi nal OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital is brazing operations on the pipe-work are to take place.
  • Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available. Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS! Charging procedures In addition to conventional charging procedures, the following requirements shall be followed:
  • Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
  • Cylinders shall be kept upright.
  • Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
  • Label the system when charging is complete, if not already labeled.
  • Extreme care shall be taken not to overfi ll the refrigeration system.
  • Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment in all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced. A. Become familiar with the equipment and its operation. B. Isolate system electrically. C. Before attempting the procedure ensure that:
  • Mechanical handling equipment is available if required for handling refrigerant cylinders.
  • All personal protective equipment is available and being used correctly.
  • The recovery process is supervised at all times by a competent person.
  • Recovery equipment and cylinders conform to the appropriate standards. D. Pump down refrigerant system, if possible. E. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system. F. Make sure that cylinder is situated on the scales before recovery takes place. G. Start the recovery machine and operate in accordance with the manufacturer’s instructions. H. Do not overfi ll cylinders. No more than 80% volume liquid charge.

I. Do not exceed the maximum working pressure of the cylinder, even temporarily.

J. When the cylinders have been fi lled correctly and the process is completed, make sure that the cylinders and the equipment are removed from the site promptly and all isolation valves on the equipment are closed off. K. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS! Labeling Equipment shall be labeled stating that it has been decommissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains fl ammable refrigerant. Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovers cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designed for the recovered refrigerant and labeled for that refrigerant, i.e. special cylinders for the recovery of refrigerant. Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of fl ammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that is it in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant leak. Consult the manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note shall be arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that fl ammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained form a system, it shall be carried out safely. Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONSINSTALLATION INSTRUCTIONS

7. Foam seal A (adhesive)

8. Foam seal B (adhesive)

9. Foam seal C (non-adhesive)

10. Security bracket and 2 screws

12. Power cord storage band

13. Remote control and batteries

1. Medium sized Phillips screwdriver

2. Tape measure or ruler

3. Knife or scissors

4. Saw (in the event that the window sliders need to

MOD E FAN LED SLEEPSWING

IMPORTANT WARNING Do not leave this appliance unattended in a space where people or animals who cannot react to a malfunction are located. A malfunction such as the exhaust hose becoming dislocated, can cause extreme overheating or death in an enclosed, unattended space.INSTALLATION INSTRUCTIONS

The instructions below can be used for either a hung window or a sliding window application.

1. Measure the window opening where the window kit will be

installed. Assemble as many sliders as necessary to fi t the window. If the window opening is less than the minimum length of a single slider, use the slider that has the hole in it and cut it to the correct length. Make sure not to cut the end that has the hole as this is necessary to attach the exhaust hose adapter. Cut the adhesive foam seals to the correct length for the window and attach them to the window sash and frame.

2. Connect the window slider adapter to the window slider by

gently pressing it into the hole in the slider until it clicks into place.

3. Attach the exhaust hose to the window slider adapter by

gently pressing it into the adapter until it clicks into place.

4. Install the slider kit and hose assembly and close the window

to hold it in place.

5. Attach the air outlet adapter to the back of the appliance

by sliding it down into the channel around the air outlet. Attach the hose to the air outlet adapter on the back of the appliance by gently pressing it into the adapter until it clicks into place.

6. Cut the non-adhesive foam seal to match the width of the

window and insert it between the glass and the window frame to prevent air and insects from getting into the room.

7. Install the security bracket in the window frame with the

provided screws. Note: Do not over extend or bend the hose as this will impede air fl ow.

2. Handle (both sides)

1. Upper air fi lter and air intake

2. Continuous drain outlet

3. Lower air fi lter and air intake

5. Power cord storage band

LOCATION Place the air conditioner on a smooth, level fl oor that is strong enough to support it and all included accessories. Make sure the appliance is level to minimize noise and vibration. The appliance must be installed near a grounded receptacle and the overfl ow drain outlet on the rear of the appliance must be accessible. Do not cover air inlets or outlets or the remote control receiver on the control panel. The appliance requires 30 cm (12 inches) of clearance on the front and sides and the horizontal louver blade should be 50 cm (20 inches) away from obstacles. The appliance requires at least 50 cm (20 inches) of clearance on the back.15 OPERATING INSTRUCTIONS CONTROL PANEL

1. Swing and wireless connect button:

  • Press to start the auto swing feature. When auto swing is activated, press again to stop the louver at the desired angle.
  • Press and hold for three seconds to start using the wireless connect feature.
  • Press to select fan speed. Light will indicate current speed.
  • Press and hold for 3 seconds to turn the continuous fan on or off.
  • Used to set the temperature and timer.
  • Press and hold both temperature control buttons for three seconds to change the temperature display from °C to °F.
  • Shows the set temperature in °C or °F.
  • Shows the timer settings.
  • While on dry mode, shows the relative humidity.
  • When on fan mode, shows the room temperature.

6. Sleep and fi lter button:

  • Press to start the sleep feature.
  • The fi lter light will illuminate after 250 hours of use as a reminder to clean the fi lter; to reset the fi lter after cleaning, press and hold the sleep button for three seconds.

7. Mode button: Press to select the desired mode. Modes will cycle in sequence with each press of the

button; auto, cool, dry, fan. Light will indicate current mode.

8. Power button: Press to turn the appliance on or off.

  • Use the temperature control buttons to choose the desired temperature.
  • Use the fan button to choose the desired fan speed.
  • The temperature can be set within a range of 17 - 30°C (62 - 86°F).
  • The exhaust hose should be installed during cool mode to ensure the best results. Dry Mode Choose dry mode to remove excess moisture from the air. Water will condense inside the appliance and drain out the back.
  • The humidity level and fan speed will be automatically set and cannot be modifi ed in dry mode.
  • The exhaust hose does not need to be installed during dry mode.
  • It may be necessary to install the continuous drain hose during dry mode to remove excess water. OPERATING INSTRUCTIONS OPERATING MODES Fan Mode Fan mode can be used to run the fan without engaging the cooling or dehumidifying functions.
  • Press the fan button to choose the desired fan speed.
  • The exhaust hose does not need to be installed during fan mode.
  • In cooling or dry mode, press and hold the fan button for 3 seconds to set the fan to run continuously. Press and hold the fan button for 3 seconds to disengage the continuous fan. During normal operation the fan will turn on and off with the compressor. Auto Mode Auto mode is a pre-set factory program that automatically defi nes the mode (cool or fan) and fan speed based on the set temperature and the ambient temperature. The exhaust hose should be installed during auto mode. 16OPERATING INSTRUCTIONS

1. When the air conditioner is turned on, press the

timer button to activate the auto off timer.

2. Press the temperature control buttons to change

the set time in 0.5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours. Auto On

1. When the air conditioner is turned off, press the

timer button to activate the auto on timer.

2. Press the temperature control buttons to change

the set time in 0.5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours. TIMER Using Auto On and Auto Off Together The auto on and auto off timers can be used at the same time by fi rst setting one and then the other. For example, if the air conditioner is running, you can set the auto off timer to let it run for a set amount of time before turning off and then set the auto on timer to turn it back on at a later time. Or, if the air conditioner is not running, you can set the auto on timer to turn it on at a later time and then set the auto off timer to shut it off after running for a period of time. Note: The timer will not cycle the air conditioner on and off indefi nitely. The auto on and auto off timers will function one time and then the air conditioner will return to regular functioning. Turning the air conditioner on or off at any time or changing the timer setting to 0.0 will cancel the timer settings.OPERATING INSTRUCTIONS

There is a temperature sensor built into the remote control that will continuously collect the current room temperature. Keep the remote control with you and the appliance will automatically adjust the set temperature based on the current temperature where you are located to reach the most comfortable condition and temperature. Press the follow me button to activate the follow me function. The remote will display the current temperature at its location. The remote will send a signal to the air conditioner every 3 minutes, so long as you remain within range of the appliance. The follow me light on the control panel of the appliance will illuminate for 5 seconds every three minutes to indicate that it has received a signal from the remote. If the appliance does not receive a signal from the remote during any 7 minute interval, it will beep to indicate that the follow me mode has ended. The maximum distance for the follow me feature is 8 meters (26 feet). This feature is available in cool and auto modes. SLEEP FUNCTION The sleep function can be used to conserve energy during sleeping hours. When selected, the set temperature will increase by 1°C/2°F every half hour for one full hour. The appliance will hold the new set temperature for 6 hours before automatically returning to normal operation. The sleep function can be canceled at any time by pressing the sleep button. SHORTCUT FUNCTION The shortcut function can be used to save a favourite setting. To set a favourite, set the appliance to the desired temperature and fan speed. Press and hold the shortcut button for 2 seconds. Press the shortcut button at any point in future to return to the favourite setting. If no favourite is set, pressing the shortcut button will cause the appliance to run in auto mode at 29°C (79°F), with fan speed set to auto. The shortcut function is only available on the remote control. WIRELESS CONNECTION This appliance can be controlled with a wireless application on your wireless device. Visit https://www.danby.com/support/#apps to download the application and learn about its operation.OPERATING INSTRUCTIONS

1. Power button: Press to turn the appliance on or

4. Sleep button: Press to start the sleep feature.

5. Swing button: Press to start the auto swing

feature. When auto swing is activated, press again to stop the louver at the desired angle.

9. Timer on button: Press to set the automatic on

10. Shor tcut button: Press to set and activate the

  • Used to set the temperature.
  • Press and hold both temperature control buttons for 3 seconds to change the temperature display from °C to °F.
  • Shows the set temperature in °C or °F or the auto-timer settings.
  • Shows whether the follow me function is active.

This air conditioner comes with two AAA batteries. Place the batteries in the remote control before use.

1. Slide the back cover from the remote downward to expose the battery compartment.

2. Insert the batteries, ensure to match the (+) and (-) symbols on the ends of the batteries with the symbols

inside the battery compartment.

3. Slide the battery cover back into place.

  • The air conditioner will not respond if curtains, doors or other materials block the signal from the remote control to the unit.
  • Prevent any liquid from contact with the remote control. Do not expose the remote control to direct sunlight or heat.
  • If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
  • Do not mix old and new batteries or batteries of different types.
  • Do not leave the batteries in the remote control if it is not going to be used for more than 2 months. IMPORTANT Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.OPERATING INSTRUCTIONS

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

1. Reorient or relocate the receiving antenna

2. Increase the separation between the equipment and receiver

3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

4. Consult the dealer or an experienced radio/TV technician for help

Changes or modifi cations not approved by the party responsible for FCC and Industry Canada compliance could void the user’s authority to operate the equipment. This appliance complies with Part 15 of the FCC Rules and license-exempt RSS standards. Operation is subject to the following conditions:

1. This device may not cause interference.

2. This device must accept any interference received, including interference that may cause undesired

operation. This equipment complies with FCC RF and IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm(8 inches) between the radiator and your body. This device complies with RSS-247 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. This device complies with Canadian CAN ICES-3 (B) / NMB-3 (B) This device contains:

WATER DRAINAGE When the internal drain pan becomes full the appliance will beep 8 times and the digital display will show error code P1. The air conditioning or dehumidifying action will stop but the fan may continue to operate. There are two methods to drain water from the appliance.

1. Turn the appliance off and unplug it from the power source.

2. Carefully move the appliance to a location where the water can

3. Remove the drain plug and allow the water to completely drain.

4. Replace the bottom drain plug, pressing fi rmly to ensure a tight fi t

5. The P1 error symbol will disappear and the appliance will

resume regular function once power is restored.

During the Dry mode, you may wish to set up the continuous drain option so that the appliance will automatically drain collected water. Remove the exhaust hose during Dry mode, it is not necessary. Ensure that the appliance is turned off and unplugged from the power source before setting up the drain hose. Remove the upper drain plug and attach the drain hose that was provided with the appliance. Ensure that there are no kinks or bends in the drain hose as this can stop water from draining. Place the open end of the drain hose over the receptacle that the appliance will drain into; this could be a basement fl oor drain, a sink or similar. Remember that there is no drain pump in this appliance, the continuous drain is activated by gravity only. Ensure that the drain hose goes straight down toward the fl oor from the drain connection. If the hose is not positioned directly downwards, water will not drain correctly.

  • Unplug the appliance before cleaning or servicing.
  • Clean the cabinet with a lukewarm damp cloth and neutral detergent. Dry the cabinet with a lint-free dry cloth.
  • Do not use gasoline, paint thinner or other chemicals to clean the appliance.
  • Do not wash the appliance directly under a tap or using a hose. It may cause electrical damage. AIR FILTERS There are three air fi lters in this appliance. Air fi lters should be cleaned every two weeks to ensure effi cient performance. In households with animals, the air fi lters may need to be cleaned more often and the external grills may need to be wiped to prevent blocked air fl ow.

1. Drain all water from the appliance.

2. Run the appliance on Fan mode for half a day in

a warm room to dry the inside of the appliance and prevent mold formation.

3. Turn off the appliance and unplug it, wrap the

cord and bundle it with tape.

4. Remove the batteries from the remote control.

5. Clean the air fi lters and reinstall them.

6. Store the appliance in a cool, dark place.

Prolonged exposure to direct sunlight or extreme heat can shorten the lifespan of the appliance. DISPOSAL This appliance should not be treated as regular household waste. Check for local regulatory compliance regarding the approved and safe disposal of this appliance. ERROR CODES E1 - room temperature sensor error E2 - evaporator temperature sensor error E4 - display panel communication error P1 - water tray is full - attach drain hose and drain excess water24

FREQUENTLY ASKED QUESTIONS

Can I leave my AC in place through the winter? This is not recommended. What are the standard wattage and amps used? Information pertaining to watts and amps can be found on the rating plate located on the side of the unit. When should I use the exhaust hose? The exhaust hose should be used in cool and auto modes. It is not required in fan and dry modes. Can I use an extension cord? No, an extension cord may not be used. Can I extend the length of the exhaust hose? No. The unit was designed with the length of the hose in mind and has only been tested under those conditions. Instead use an additional fan to blow the cool air to other locations. When should I use the drain hose? The drain hose should be used in dry mode or if using the continuous drain. Where do I drain water from? The water drains from the drainage port. If you are not using the continuous drain, the internal pan drains from the bottom outlet. Odors Odour is caused by the formation of mold or mildew on internal surfaces. This can happen when there is poor air circulation, a dirty fi lter or the air conditioner was not used for a period of time.

  • Ensure the fi lter is clean.
  • Run the unit on fan mode to remove any internal moisture.
  • Check for any blockages in the drain lines and ensure there are no obstructions. Please give your unit a hard reboot. Unplug it and plug it back in after 15-20 minutes. This allows the unit to warm and drain if there is any frost stopping draining and go back to factory settings For odour in a unit, we suggest using an algaecide tablet. You fi rst need to turn the unit off, remove the lower grill and fi lter from the grill at the base of the unit, and then place the tablet in base.TROUBLESHOOTING

Appliance will not operate

  • Plug is not fully inserted into the wall outlet
  • Blown fuse or circuit breaker Insuffi cient cooling
  • Appliance size is too small for application Noise
  • The ground is not level
  • The air fi lter is dirty or blocked
  • Gurgling sounds are normal, this is coolant moving inside the appliance Odors
  • Formation of mold or mildew on internal wet surfaces
  • Place an algaecide tablet in the base pan; ensure the appliance is unplugged, remove the upper grille and fi lter, place the tablet in the middle water tray and replace the grille and fi lterLIMITED IN-HOME APPLIANCE WARRANTY This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.TERMS OF WARRANTY Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided. First Year During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s option, at no charge to the ORIGINAL purchaser. To obtain Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance Service requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below. Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service must be performed by a qualied service technician. If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all obligations of Danby under this warranty shall be void. Boundaries of If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be In Home Service delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he responsibility of the purchaser. Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.EXCLUSIONS Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit. GENERAL PROVISIONS No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:

2) Damage in transit or when moving the appliance.

3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.

4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions (extremely high or low room temperature).

5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).

6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.

7) Service calls resulting in customer education.

8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application). Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our AUTHORIZED SERVICE DEPOT.Danby Products LimitedPO Box 1778, Guelph, Ontario, Canada N1H 6Z9Telephone: (519) 837-0920 FAX: (519) 837-0449Danby Products Inc.PO Box 669, Findlay, Ohio, U.S.A. 45840Telephone: (419) 425-8627 FAX: (419) 425-862904/09 1-800-263-2629 Warranty ServiceIn-home Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an authorized service depot. Any appliance requiring service outside the limited boundaries of “In Home Service”, will be the consumer’s responsibility to transport at their own expense to the original point of purchase or a service depot for repair. If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center, it must be delivered to the nearest authorized Danby Service Depot by the purchaser. Transportation charges to and from the service location are not protected by this warranty and are the responsibility of the purchaser. During the first twenty four (24) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s option, at no charge to the original purchaser. Contact the dealer where the unit was purchased, or contact the nearest authorized Danby service depot, where service must be performed by a qualified service technician. If service is performed on the unit by anyone other than an authorized service depot, all obligations of Danby under this warranty shall be void.First 24 monthsTo obtain service Boundaries ofin-home service

LIMITED “IN HOME” WARRANTY

This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.TERMS OF WARRANTY Plastic parts are warranted for thirty (30) days from the date of purchase, with no extensions provided. Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.EXCLUSIONS Save as herein provided, by Danby, there are no other warranties, conditions, representations or guarantees, express or implied, made or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditions, representations or guarantees under any Sale of Goods Act or like legislation or statute is hereby expressly excluded. Save as herein provided, Danby shall not be responsible for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or property caused by the unit.GENERAL PROVISIONS No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following: 1) Power failure.2) Damage in transit or when moving the appliance.3) Improper power supply such as low voltage, defective house wiring or inadequate fuses. 4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions (ie. extremely high or low room temperature).5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence). 6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.7) Service calls resulting in customer education. 8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor application, including but not limited to: garages, patios, porches or anywhere that is not properly insulated or climate controlled). Proof of purchase date will be required for warranty claims; retain bills of sale. In the event that warranty service is required, present the proof of purchase to our authorized service depot. Warranty Service In Home Danby Products Limited PO Box 1778, Guelph, Ontario, Canada N1H 6Z9 Telephone: (519) 837-0920 FAX: (519) 837-0449 Danby Products Inc. PO Box 669, Findlay, Ohio, U.S.A. 45840 Telephone: (419) 425-8627 FAX: (419) 425-8629 1-800-263-2629 04/1727 Bienvenue dans la famille Danby. Nous sommes fi ers de nos produits de qualité et nous croyons en un service fi able. Nous vous suggérons de lire ce manuel du propriétaire avant de brancher votre nouvel appareil car il contient des informations de fonctionnement importantes, des informations de sécurité, des conseils de dépannage et d’entretien pour assurer la fi abilité et la longévité de votre appareil. Vous avez droit à la couverture de la garantie décrite dans le manuel du propriétaire fourni avec votre nouvel appareil.

MOD E FAN LED SLEEPSWING

  • Placer un comprimé d’algicide dans la casserole de base; assurez-vous que l’appareil est débranché, retirez la grille supérieure et le fi ltre, placez la tablette dans le bac à eau du milieu et remplacez la grille et le fi ltreLIMITED IN-HOME APPLIANCE WARRANTY This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.TERMS OF WARRANTY Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided. First Year During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s option, at no charge to the ORIGINAL purchaser. To obtain Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance Service requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below. Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service must be performed by a qualied service technician. If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all obligations of Danby under this warranty shall be void. Boundaries of If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be In Home Service delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he responsibility of the purchaser. Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.EXCLUSIONS Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit. GENERAL PROVISIONS No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:

2) Damage in transit or when moving the appliance.

3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.

4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions (extremely high or low room temperature).

5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).

6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.

7) Service calls resulting in customer education.

MOD E FAN LED SLEEPSWING

  • Coloque una tableta de alguicida en la bandeja base; asegúrese de que el aparato esté desenchufado, retire la rejilla superior y el fi ltro, coloque la tableta en la bandeja de agua intermedia y reemplace la rejilla y el fi ltroLIMITED IN-HOME APPLIANCE WARRANTY This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.TERMS OF WARRANTY Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided. First Year During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s option, at no charge to the ORIGINAL purchaser. To obtain Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance Service requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below. Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service must be performed by a qualied service technician. If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all obligations of Danby under this warranty shall be void. Boundaries of If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be In Home Service delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he responsibility of the purchaser. Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.EXCLUSIONS Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit. GENERAL PROVISIONS No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:

2) Damage in transit or when moving the appliance.

3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.

4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions (extremely high or low room temperature).

5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).

6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.

7) Service calls resulting in customer education.