USER MANUAL GEDP 7330 LL EINHELL

1. Safety regulations

2. Layout and items supplied

5. Before starting the equipment

8. Cleaning, maintenance and ordering of spare parts

9. Disposal and recycling

This equipment can be used by children of 8 years and older and by people with limited physical, sensory or mental capacities or those with no experience and knowledge if they are supervised or have re- ceived instruction in how to use the equipment safely and understand the dangers which result from such use. Children are not allowed to play with the equipment. Unless supervised, children are not allowed to clean the equipment and carry out user-level maintenance work. If the power cable for this equipment is damaged, it must be replaced by the manufacturer or its after-sales service or similarly trained per- sonnel to avoid danger. Danger! - Read the operating instructions to reduce the risk of inquiry Anl_GE_DP_7330LL_5220LL_SPK7.indb 17Anl_GE_DP_7330LL_5220LL_SPK7.indb 17 15.10.14 10:0715.10.14 10:07GB

Danger! When using the equipment, a few safety pre- cautions must be observed to avoid injuries and damage. Please read the complete operating instructions and safety regulations with due care. Keep this manual in a safe place, so that the in- formation is available at all times. If you give the equipment to any other person, hand over these operating instructions and safety regulations as well. We cannot accept any liability for damage or accidents which arise due to a failure to follow these instructions and the safety instructions.

1. Safety regulations

Danger! Read all safety regulations and instructions. Any errors made in following the safety regula- tions and instructions may result in an electric shock, fi re and/or serious injury. Keep all safety regulations and instructions in a safe place for future use. Danger! The pump must be powered via an earth-leakage circuit breaker (RCD) with a rated fault current of no more than 30 mA (according to VDE 0100

The equipment is not designed for use in swimming pools and paddling pools of any kind or other bodies of water in which people or animals may be present during operation. It is prohibited to operate the equipment if a person or animal is in the danger area. Ask your electrician!

Before you put the equipment into operation, arrange for a specialist to check that the earthing, protective multiple earthing or residual-current operated circuit-breaker circuit comply with the safety regu- lations of the power supply company and work correctly.

The electrical plug-in connec- tions must be protected from wet conditions.

If there is a risk of flooding, place the plug-in connections in an area which is safe from flooding.

Strictly avoid pumping aggres- sive liquids and abrasive sub- stances.

Protect the equipment from frost.

Protect the equipment from dry running.

Take suitable measures to keep the equipment out of the reach of children.

There is a risk of the liquid becoming contaminated by escaping lubricant.

2. Layout and items supplied

2.1 Layout (Fig. 1/2)

1. Universal hose connection

3. Screw for height adjustment

Please check that the article is complete as specifi ed in the scope of delivery. If parts are missing, please contact our service center or the sales outlet where you made your purchase at the latest within 5 working days after purchasing the product and upon presentation of a valid bill of purchase. Also, refer to the warranty table in the service information at the end of the operating Anl_GE_DP_7330LL_5220LL_SPK7.indb 18Anl_GE_DP_7330LL_5220LL_SPK7.indb 18 15.10.14 10:0715.10.14 10:07GB

Open the packaging and take out the equip- ment with care.

Remove the packaging material and any packaging and/or transportation braces (if available).

Check to see if all items are supplied.

Inspect the equipment and accessories for transport damage.

If possible, please keep the packaging until the end of the guarantee period. Danger! The equipment and packaging material are not toys. Do not let children play with plastic bags, foils or small parts. There is a danger of swallowing or suff ocating!

Universal hose connection

Original operating instructions

The equipment you have purchased is designed to pump water with a maximum temperature of 35 °C. This equipment must never be used for other liquids, especially not for engine fuels, cleaning agents and other chemically-based products! Before you use the pump, clarify any possible special conditions which need to be fulfi lled for the installation! For example, additional safety measures may be needed if damage to property could result from a power failure, soiling or a defective gasket. Examples of such safety measures: Pumps running in parallel on a separately protec- ted power circuit, moisture sensors for switching off the pumps, and similar safety arrangements. Be sure to consult a professional plumber if you have any doubt. The equipment can be used wherever you want to move water, e.g. in the house, in the garden, and for many other applications. It must not be used to operate swimming pools! If you want to use the equipment in bodies of wa- ter with a natural, muddy bottom, place the equip- ment in a slightly elevated position, e.g. on bricks. The equipment is not designed for continuous operation, e.g. as a circulating pump in a pond. In this case the equipment’s anticipated life will be greatly shortened because the equipment was not designed for continuous loading. The equipment is to be used only for its prescri- bed purpose. Any other use is deemed to be a case of misuse. The user / operator and not the manufacturer will be liable for any damage or inju- ries of any kind caused as a result of this. Please note that our equipment has not been de- signed for use in commercial, trade or industrial applications. Our warranty will be voided if the machine is used in commercial, trade or industrial businesses or for equivalent purposes. The water may be contaminated by escaping lub- ricating oil/lubricant.

5. Before starting the equipment

Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.

The equipment can be installed either:

Stationary with a rigid pipe line

Stationary with a flexible hose line The equipment must be fastened to the suspensi- on eyelet with a rope (Fig. 2/Item 6). The maximum pumping rate is possible only with the largest possible line diameter; if smaller hoses or pipes are connected, the pumping rate will be reduced. If the universal hose connection (Fig. 1/ Item 1) is used, it should be shortened (as shown in Fig. 9) to the connection actually used in order not to reduce the pumping rate unnecessarily. Flexible hoses must be fastened to the universal hose connection with a hose clip (not included in the scope of supply). Note! When installing, never hang the equipment by the discharge line or by the power cable. The equipment must be hung up by the provided carry handle or suspension eyelet, or it must rest on the bottom of the shaft. To ensure that the equipment works properly, the bottom of the shaft always must be free of sludge and other accumulations of dirt. If the water level is too low, the sludge in the shaft can quickly dry out and hinder the equipment from starting. It is necessary therefore to check the equipment regularly (carry out trial start-ups). The pump shaft should measure at least 50 x 50 x 50 cm so that the fl oating switch can move freely.

5.2 Mains connection

Danger! The equipment you have purchased comes with an earthing-pin plug. The equipment is designed for connection to a socket outlet with earthing contact for 230 V ~ 50 Hz. Make sure that the socket-outlet is suffi ciently fused (at least 6 A) and in good working order. Insert the power plug in the socket-outlet and the equipment is ready for operation. Danger! To rule out danger, this work must be left strictly to a specialist electrician or Customer Service.

You can put the equipment into operation after you have thoroughly read the installation and ope- rating instructions. Pay attention to the following points:

Make sure that the equipment is set up secu- rely.

Check that the discharge line is fitted correct- ly.

Make sure that the electrical connection is 230 V ~ 50 Hz.

Check that the electrical socket-outlet is in good working order.

Make sure that no moisture or water can ever reach the power connection.

Make sure that the equipment does not run dry.

To switch off the equipment, pull the power plug out of the socket outlet. Setting the On/Off switching point: The ON/OFF switching point can be infi nitely ad- justed with the height adjustment facility. For this purpose you must fi rst slacken the screw (Fig. 3, Item 3). The switching diff erential can be infi nitely adjusted by extending or shortening the fl oat cable (Fig. 3).

The floating switch must be fitted so that the switching point height: ON and the switch point height: OFF can be reached easily and with little force. Check this by placing the equipment in a container filled with water and carefully raising and lowering the floating switch with your hand. You can then see whe- ther the equipment switches on and off.

Make sure that the distance between the floa- ting switch head and the cable holder is not too smaller than 10 cm (Fig. 3). If the distance is too small, there is no guarantee that the equipment will work correctly.

When adjusting the floating switch, make sure that the floating switch does not touch the bottom before the equipment is switched off. Important! Risk of dry running. Anl_GE_DP_7330LL_5220LL_SPK7.indb 20Anl_GE_DP_7330LL_5220LL_SPK7.indb 20 15.10.14 10:0715.10.14 10:07GB

Manual operation: Mount the fl oating switch as illustrated in Fig. 1. The equipment will then run continuously. To pre- vent dry running, this operating mode is allowed only under supervision. The equipment must be switched off (pull out the power plug) as soon as no more water is emitted from the discharge line. Dirty water mode (Fig. 4/5):

Turn the equipment counter-clockwise up as far as the stop (Fig. 4/5). Shallow suction mode (Fig. 5):

Turn the equipment clockwise down as far as the stop (Fig. 5).

In shallow suction mode, water can be su- cked up down to a level of 1 mm.

Only clean water can be sucked up in shallow suction mode. Please note: For the equipment to suck up water in shallow suction mode there must be a minimum depth of 10 mm of water.

7. Replacing the power cable

Danger! If the power cable for this equip- ment is damaged, it must be replaced by the manufacturer or its after-sales service or similarly trained personnel to avoid dan- ger.

8. Cleaning, maintenance and

ordering of spare parts Danger! Always pull out the mains power plug before star- ting any cleaning work.

Keep all safety devices, air vents and the motor housing free of dirt and dust as far as possible. Wipe the equipment with a clean cloth or blow it with compressed air at low pressure.

We recommend that you clean the device immediately each time you have finished using it.

Clean the equipment regularly with a moist cloth and some soft soap. Do not use cleaning agents or solvents; these could at- tack the plastic parts of the equipment. Ensu- re that no water can seep into the device. The ingress of water into an electric tool increases the risk of an electric shock.

8.2 Cleaning the intake cage and pump

housing (Fig. 5/6/7/8):

1. Screw out the three screws (Fig. 6/Item B)

2. Turn the equipment up as far as the stop (Fig.

5). Note the position of the lug (Fig. 5/Item A) and remove the intake cage (Fig.7/Item 4).

3. Clean the intake cage (Fig. 7/Item 4) and the

pump impeller housing (Fig.7/Item C) with clean water.

4. Assemble in reverse order.

There are no parts inside the equipment which require additional maintenance.

8.4 Ordering replacement parts:

Please quote the following data when ordering replacement parts:

Article number of the machine

Identification number of the machine

9. Disposal and recycling

The equipment is supplied in packaging to pre- vent it from being damaged in transit. The raw materials in this packaging can be reused or recycled. The equipment and its accessories are made of various types of material, such as metal and plastic. Never place defective equipment in your household refuse. The equipment should be taken to a suitable collection center for proper disposal. If you do not know the whereabouts of such a collection point, you should ask in your local council offi ces.

Store the equipment and accessories in a dark and dry place at above freezing temperature. The ideal storage temperature is between 5 and 30 °C. Store the electric tool in its original packaging. Anl_GE_DP_7330LL_5220LL_SPK7.indb 22Anl_GE_DP_7330LL_5220LL_SPK7.indb 22 15.10.14 10:0715.10.14 10:07GB

Faults Cause Remedy The equipment does not start - Power supply not connected - Floating switch does trigger - Check power supply - Raise position of fl oating switch The equipment does not pump - Intake sieve clogged - Discharge hose kinked - Clean intake sieve with water jet - Unkink the hose The equipment does not cut out - Floating switch cannot sink - Place equipment correctly on shaft bottom Insuffi cient pumping rate - Intake sieve clogged - Performance reduced due to heavi- ly contaminated and abrasive water impurities - Clean intake sieve - Clean equipment and replace wear parts The equipment swit- ches off after briefl y running - Motor circuit-breaker switches the equipment off due to excessive wa- ter contamination - Water temperature too high; motor circuit-breaker switches the equip- ment off - Unplug power plug and clean equipment and shaft - Ensure that maximum permissible water temperature (35 °C) is not exceeded Anl_GE_DP_7330LL_5220LL_SPK7.indb 23Anl_GE_DP_7330LL_5220LL_SPK7.indb 23 15.10.14 10:0715.10.14 10:07GB

For EU countries only Never place any electric power tools in your household refuse. To comply with European Directive 2012/19/EC concerning old electric and electronic equipment and its implementation in national laws, old electric power tools have to be separated from other waste and disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot. Recycling alternative to the return request: As an alternative to returning the equipment to the manufacturer, the owner of the electrical equipment must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment. The old equipment can be returned to a suitable collection point that will dispose of the equipment in accordance with the national recycling and waste disposal regulations. This does not apply to any ac- cessories or aids without electrical components supplied with the old equipment. The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of the iSC GmbH. Subject to technical changes Anl_GE_DP_7330LL_5220LL_SPK7.indb 24Anl_GE_DP_7330LL_5220LL_SPK7.indb 24 15.10.14 10:0715.10.14 10:07GB

Service information We have competent service partners in all countries named on the guarantee certifi cate whose contact details can also be found on the guarantee certifi cate. These partners will help you with all service re- quests such as repairs, spare and wearing part orders or the purchase of consumables. Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also required for use as consumables. Category Example Wear parts* Impeller Consumables* Missing parts

  • Not necessarily included in the scope of delivery! In the eff ect of defects or faults, please register the problem on the internet at www.isc-gmbh.info. Ple- ase ensure that you provide a precise description of the problem and answer the following questions in all cases:

Did the equipment work at all or was it defective from the beginning?

Did you notice anything (symptom or defect) prior to the failure?

What malfunction does the equipment have in your opinion (main symptom)? Describe this malfunction. Anl_GE_DP_7330LL_5220LL_SPK7.indb 25Anl_GE_DP_7330LL_5220LL_SPK7.indb 25 15.10.14 10:0715.10.14 10:07GB

Warranty certifi cate Dear Customer, All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card. You can also contact us by telephone using the service number shown. Please note the following terms under which guarantee claims can be made:

1. These guarantee conditions regulate additional guarantee services. Your statutory guarantee claims

are not aff ected by this guarantee. Our guarantee is free of charge to you.

2. Our guarantee only covers defects suff ered by the device which have been verifi ably caused by a

material or manufacturing fault and is limited to the rectifi cation of such defects or the replacement of the device at our discretion. Please note that our devices are not designed for use in commercial, trade or professional applica- tions. A guarantee contract will not be created if the device has been used by commercial, trade or industrial business or has been exposed to similar stresses during the guarantee period.

3. The following are not covered by our guarantee:

- Damage to the device caused by a failure to follow the assembly instructions or due to incorrect installation, a failure to follow the operating instructions (for example connecting it to an incorrect mains voltage or current type) or a failure to follow the maintenance and safety instructions or by ex- posing the device to abnormal environmental conditions or by lack of care and maintenance. - Damage to the device caused by abuse or incorrect use (for example overloading the device or the use or unapproved tools or accessories), ingress of foreign bodies into the device (such as sand, stones or dust, transport damage), the use of force or damage caused by external forces (for ex- ample by dropping it). - Damage to the device or parts of the device caused by normal or natural wear or tear or by normal use of the device.

4. The guarantee is valid for a period of 24 months starting from the purchase date of the device. Gu-

arantee claims should be submitted before the end of the guarantee period within two weeks of the defect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are replaced. In such cases, the work performed or parts fi tted will not result in an extension of the guarantee period, and no new guarantee will become active for the work performed or parts fi tted. This also applies if an on-site service is used.

5. Please report the defective device on the following internet address to register your guarantee claim:

www.isc-gmbh.info. If the defect is covered by our guarantee, then the item in question will either be repaired immediately and returned to you or we will send you a new replacement device. Of course, we are also happy off er a chargeable repair service for any defects which are not covered by the scope of this guarantee or for units which are no longer covered. To take advantage of this service, please send the device to our service address. Also refer to the restrictions of this warranty concerning wear parts, consumables and missing parts as set out in the service information in these operating instructions. Anl_GE_DP_7330LL_5220LL_SPK7.indb 26Anl_GE_DP_7330LL_5220LL_SPK7.indb 26 15.10.14 10:0715.10.14 10:07F

= dB (A); guaranteed L