Product type Anti-cellulite vibration massager
Brand Maxxmee
Model 04234
Power supply 12 V DC, 2 A (100-240 V, 50/60 Hz AC adapter)
Maximum power 28 W
Maximum vibration frequency 2300 rpm
Included patches 3 patches (white: gentle massage, blue: blood circulation, orange: anti-cellulite)
Intensity adjustment Continuous from ON to MAX via rotary knob
Application areas Arms, legs, abdomen (avoid head, neck, chest)
Usage duration per area Maximum 5 minutes per day
Cleaning the device Damp cloth, then dry with a dry cloth
Cleaning the patches Hand wash at 30°C, air dry (no tumble dryer, no ironing)
Safety conditions Do not use near water, on damaged skin, or in the presence of medical implants
Minimum age of use 12 years (adult supervision for persons with reduced capabilities)
Protection class (adapter) II
Protection rating IP20
Repairability Contact customer service; do not disassemble yourself
Original accessories Use only supplied or original accessories
Package contents 1 device, 1 AC adapter, 3 patches, 1 instruction manual

Frequently Asked Questions - 04234 Maxxmee

How to use the Maxxmee 04234 massager?
Choose the appropriate patch (white for relaxation, blue for circulation, orange for cellulite) and place it on the massage head. Plug in the adapter, turn on the device with the rotary knob and adjust the intensity. Apply to the desired area for a few minutes without applying strong pressure. After use, turn off and unplug.
What are the three included patches and what are they used for?
The white patch offers a gentle relaxing massage. The blue patch stimulates blood circulation and firms the skin. The orange patch is designed to treat early cellulite.
Can I use the device on my face or neck?
No, it is not recommended to use the device on the head, neck, and chest. Limit application to arms, legs, and abdomen.
Is the device waterproof?
No, the device is not waterproof. It should not be used near water (bathtub, shower) or immersed in water. The protection rating is IP20, meaning it is protected against solid objects but not against water.
How to clean the device and the patches?
Clean the device with a damp cloth then dry it with a dry cloth. The patches should be hand washed at 30°C and air dried. Do not use fabric softener, tumble dryer, or iron.
How long can I massage the same area?
Do not exceed 5 minutes per day on the same area to avoid overstimulating the skin and tissues.
Can I use the device if I am pregnant?
Pregnant women should only use the device after prior medical approval. In general, avoid use during pregnancy without medical advice.
What to do if the device falls into water?
If the device is still plugged in, do not touch it! Immediately remove the AC adapter from the outlet, then take the device out of the water. Do not reuse it until it has been checked by a specialized workshop.
Where can I find spare parts or accessories?
Contact customer service via the manufacturer's website to obtain spare parts or original accessories. Only use original accessories to ensure proper operation.
Is the device suitable for children?
The device is not suitable for children under 12 years. Children over 12 or persons with reduced capabilities should only use it under adult supervision.

User questions about 04234 Maxxmee

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Massage device in PDF format for free! Find your manual 04234 - Maxxmee and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 04234 by Maxxmee.

USER MANUAL 04234 Maxxmee

MAXXMEE Exxtra for you

natural_image Product photo of a MaxxMee brush and two circular powder brushes (no text or symbols visible on the brushes themselves)

DE

Gebrauchsanleitung

FR

Mode d'emploi

EN

Operating instructions

NL

When May the Device Not Be Used? 13

Safety Notices 14

General Notices 16

Use 16

Cleaning and Storage 17

Disposal 17

Technical Data 18

AT A GLANCE

Maxxmee 04234 - AT A GLANCE - 1

text_image 1 2 3 4 MAX PM

1 Grip
2 Knob for switching the device on and off and for setting the intensity
3 Socket for the connecting cable
4 Massage head

Dear Customer,

We are delighted that you have chosen the MAXXMEE cellulite massage device.

You can very simply apply this compact device to your arms, legs, abdomen etc. as you wish. Just place on one of the three enclosed pads and infinitely adjust the vibration intensity until it feels pleasant to you. With the white pad, for example, you can enjoy a gentle, relaxing massage, with the blue pad you can promote blood circulation in your skin, or with the orange pad you can target the onset of cellulite.

If you have any questions about the device and about spare parts/accessories, contact the customer service department via our website:

We hope you have a lot of fun with your MAXXMEE cellulite massage device.

Information About the Operating Instructions

Before using the device for the first time, please read through these operating instructions carefully and keep them for future reference and other users. They form an integral part of the device. The manufacturer and importer do not accept any liability if the information in these operating instructions is not complied with.

SYMBOLS

Maxxmee 04234 - SYMBOLS - 1

Danger symbols: These symbols indicate possible dangers. Read the associated safety notices carefully and follow them.

Maxxmee 04234 - SYMBOLS - 2

Maxxmee 04234 - SYMBOLS - 3

Maxxmee 04234 - SYMBOLS - 4

Maxxmee 04234 - SYMBOLS - 5

Maxxmee 04234 - SYMBOLS - 6

Maxxmee 04234 - SYMBOLS - 7

Maxxmee 04234 - SYMBOLS - 8

Maxxmee 04234 - SYMBOLS - 9

Maxxmee 04234 - SYMBOLS - 10

Supplementary information

Read operating instructions before use!

Symbol for direct current

Energy efficiency class VI

Only use indoors!

Protection class II

Polarity of the barrel connector

Maxxmee 04234 - SYMBOLS - 11

Switching power supply

Maxxmee 04234 - SYMBOLS - 12

Safe electrical isolation

SIGNAL WORDS

DANGER warns of serious injuries and danger to life

WARNING warns of possible serious injuries and danger to life

NOTICE warns of material damage

ITEMS SUPPLIED

1 x Massage device
1 x Connecting cable (mains adapter with mains cable)
1 x Blue pad
1 x White pad
1 x Orange pad
1 x Operating instructions

Check the items supplied for completeness and the components for transport damage. If you find any damage, do not use the device but contact our customer service department.

Remove any possible films, stickers or transport protection from the device.

Never remove the rating plate and any possible warnings!

INTENDED USE

■ This device is designed to be used to massage the body with vibrations.
■ The device is not designed for medical or therapeutic purposes.
■ The device is for personal use only and is not intended for commercial applications.
■ Use the device only for the specified purpose and as described in the operating instructions.

Any other use is deemed to be improper.

■ The warranty does not cover faults caused by incorrect handling, damage or attempted repairs. The same applies to normal wear and tear.

WHEN MAY THE DEVICE NOT BE USED?

■ This device is not suitable for children under 12 years of age.
■ Do not use the device if you have a fever or illness / dental problems.
■ Do not use the device while you are connected to medical equipment, e.g. an ECG machine.
■ Do not use the device if you have calf pain.
■ The following people may use the device only following consultation with a doctor:

o people who are fitted with a pacemaker or similar medical implants,
o people with heart disease or who suffer from epilepsy,
o people who have spinal disorders or back complaints,
- women who are pregnant or have just given birth,
- women during their period,
o people who suffer from circulation problems or thrombosis,
o people who have undergone an operation for which the treatment is not yet complete,
o people with physical abnormalities,
o people with a malignant tumour,
- people with nerve damage,
o people under the influence of medication,
- people who belong to a risk group or who have concerns about their health.

■ Do not use the device in the vicinity of or on:

  • regions which have recently been operated on or are scarred,
  • injuries and areas of swelling,

- acne, birthmarks and warts,

- the genital area,

- injured, inflamed, (sun-)burnt, irritated or very sensitive skin,

- body parts with no feeling.

- bones and joints,

If you are unsure whether the device may be used, consult a responsible

- the rib cage close to your heart, doctor.

SAFETY NOTICES

This device is not intended to be used by people (including children) with reduced sensory or mental abilities or a lack of experience and/or knowledge, unless they are supervised by a person who is responsible for their safety or have received instruction from this person on how to use the device safely.

■ Children must not play with the device.

■ Cleaning and user maintenance must not be carried out by children, unless they are supervised.

■ Children younger than 8 years of age and animals must be kept away from the device and connecting cable.

■ Children, people who are sleeping or unconscious and animals must not be treated with the device.

■ The device must always be disconnected from the mains power when left unattended and before cleaning it.

■ Do not use the mains adapter (XH1200-2000wG) with another device and never use the device with another mains adapter.

- Do not make any modifications to the device or the connecting cable. The device may only be taken apart and / or repaired by the manufacturer, customer service department or a similarly qualified person (e.g. specialist workshop) in order to avoid any hazards. If the mains connecting cable of this device is damaged, it must be replaced with a special connecting cable which is available from the manufacturer or its customer service department.

Maxxmee 04234 - SAFETY NOTICES - 1

DANGER – Danger of Electric Shock

Maxxmee 04234 - DANGER – Danger of Electric Shock - 1

WARNING: Do not use near a bathtub, shower or any vessel containing water. Never use while bathing or showering!

■ Use and store the device only in closed rooms.
■ Do not operate or store the device in rooms with high humidity.
■ Never immerse the device and the connecting cable in water or other liquids and ensure that these components cannot fall into water or become wet.
If the device falls into water while it is connected to the mains power, do not touch the device, but pull the mains adapter out of the plug socket immediately! Only after this should you retrieve the device from the water.
■ Never touch the device and the connecting cable with wet hands when the device is connected to the mains power.
- Do not use the device if it has malfunctioned, fallen into water or if there is visible damage on the device, accessory or on the connecting cable. Have it checked in a specialist workshop before putting it back into operation.

Maxxmee 04234 - DANGER – Danger of Electric Shock - 2

WARNING – Danger of Fire

  • Keep the device away from combustible materials and substances.
    ■ Do not cover the device during operation to ensure there is sufficient air circulation.

Maxxmee 04234 - WARNING – Danger of Fire - 1

WARNING – Danger of Injury

  • Keep children and animals away from the packaging material. There is a danger of suffocation.
    ■ Make sure that the connecting cable is always kept out of the reach of small children and animals. There is a danger of strangulation.
    ■ If you experience an unpleasant feeling while using the device, stop using it immediately!
    ■ Stop using the device if you experience skin redness or discolouration that lasts for more than 24 hours.
    If the colour of the skin on the hand holding the device changes, stop using it immediately! Persistent use could result in hand-arm vibration syndrome.
    ■ Make sure that the connecting cable does not present a trip hazard.

NOTICE – Risk of Damage to Material and Property

■ Use and store the device at room temperature. Protect the device from: fire and heat sources, extreme temperatures, temperature fluctuations or prolonged direct sunlight.
- Do not place heavy objects on the device, its connecting cable or the accessories. Protect the device from impacts.
■ Only connect the mains adapter to a plug socket that is properly installed and matches the technical data of the mains adapter. The plug socket must also be readily accessible after connection so that the connection to the mains can quickly be isolated.
■ Lay the connecting cable so that it is not squashed, bent or laid over

sharp edges and does not come into contact with hot surfaces.

■ Pull the mains adapter out of the plug socket before a thunderstorm.

In the event of damage / faults, switch the device off immediately / disconnect it from the mains power.

■ When you disconnect it from the mains power, always pull on the mains adapter and never the mains cable.

■ Do not pull or carry the device by the connecting cable.

■ Never wind the mains cable around the mains adapter.

■ Use only original accessories from the manufacturer in order to guarantee that there is no interference that may prevent the device from working and to avoid possible damage.

GENERAL NOTICES

■ The device should not be used before going to sleep.

Massages have a stimulating effect, which may lead to problems getting to sleep.

■ The skin may feel warm during the treatment. This is normal and not a cause for concern.

USE

Please Note!

■ Steer well clear of the head, the neck and the chest when using the device.

■ Do not use straight after eating.

■ Do not use the device on one area of skin for longer than 5 minutes per day so that no strain is placed on the skin and tissue.

3 pads for different massages are supplied with the device:

- White pad for gentle, relaxing massage

- Blue pad for stimulating blood circulation and natural tightening of the skin

- Orange pad for treating the onset of cellulite

  1. Select a pad depending on the treatment you want and pull it over the massage head (4). Do not pull the elastic band further than the edge of the massage head so that it is not hindered by the pad when turning.

  2. First connect the connecting cable that is supplied to the socket (3) of the massage device and then connect it to a plug socket.

  3. Use the knob (2) to switch on the device and set the intensity you want (from ON to MAX position).

  4. Hold the device by the grip (1) and place the massage head on each treatment area for a few minutes. Do not press on too firmly! The device vibrates and massages.

  5. After the treatment, switch off the device with the knob (OFF position) and disconnect it from the mains.

CLEANING AND STORAGE

Please Note!

- Do not use any sharp or abrasive cleaning agents or cleaning pads to clean the device. These may damage the surfaces.

Keep the pads and the device clean.

  • Wash the pads by hand at 30^ C and allow them to dry in the air. Do not use fabric softener. Do not wash with other colours, dry in a dryer, iron, bleach or dry-clean.
  • Wipe down the device with a damp cloth if necessary. Then wipe it with a dry cloth.
  • Store the device and accessories in a dry place that is protected from dirt and direct sunlight and cannot be accessed by children or animals.

DISPOSAL

Maxxmee 04234 - DISPOSAL - 1

Dispose of the packaging material in an environmentally friendly manner so that it can be recycled.

Maxxmee 04234 - DISPOSAL - 2

This device is governed by the European Directive 2012/19/EU on waste electrical and electronic equipment (WEEE). Do not dispose of this device as normal domestic waste, but rather in an environmentally friendly manner via an officially approved waste disposal company.

TECHNICAL DATA

Article number: 04234

ID of operating instructions: Z 04234 M DS V1.1 0620 md

Device:

Model number: BG-F-0066

Power supply: 12V DC; 2A

Power: max. 28W

Vibration: max. 2300 r/m

Mains adapter:

Type of protection: IP20

∅ efficiency in operation: 86.2%

Power consumption on no-load: max. 0.1 W

Maxxmee 04234 - TECHNICAL DATA - 1

SOMMAIRE

Aperçu général 19

Symboles 20

WAARSCHUWING – Brand- gevaar

WAARSCHUWING – Verwondingsgevaar

* Calls to German landlines are subject to your provider's charges.

FR

SERVICE APRÈS-VENTE IMPORTATEUR

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Maxxmee

Model : 04234

Category : Massage device