USER MANUAL PACW212HP WHIRLPOOL

Instructions for use

FRANÇAIS NEDERLANDS Seite 4

BEFORE USING THE APPLIANCE Please ready all instructions carefully before using this product. When using this appliances, should always follow this instruction to reduce the risk of fire, electric shock, and injury to person.

Please keep this manual. If you deliver the appliance to other users, do handover this manual together. These instructions shall also be available on website: www.whirlpool.eu.

• The Installation and service/repair must be performed by a qualified technician, in compliance with the producer's instructions and following local safety norms. Do not repair or replace any parts of the appliance unless it is specifically written in the user instructions. • Do not pull the power supply cord to remove it from the socket. Do not twist or press the power supply cord, and make sure it is not broken. • Do not touch the power plug, circuit breaker and emergency button when your hands are wet. • Do not insert your fingers or foreign substances into the air inlet/outlet of indoor&outdoor unit. • Never block the air inlet or outlet of indoor and outdoor unit. • Physically or mentally disabled people, children and people without any experience with the product are only allowed to use

the appliance if they have had specific training on how to operate the appliance by a person responsible for their security and well-being. The appliance is not intended for use by disabled people and very young children without supervision.

• Children should be supervised to ensure that they do not play with the appliance (including remote control). • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

AIR CONDITIONER PRECAUTIONS Please strictly follow the below instructions:

• Long and direct exposure to cool air might be harmful to health. It is advisable to set the louvers in order to avoid direct cool air and deflect it within the room. • Upon malfunctioning first turn the appliance off by pressing the ON/OFF button on the remote control, then disconnect it from power supply. • Always turn off the air conditioner by remote control first. Do not use the power supply circuit breaker or pull off the plug to turn it off.

• Do not switch the appliance on and off too often as this can damage the appliance.

• Do not place any objects on the outdoor unit. • Disconnect the air conditioner from the power supply if it is to be left unused for a long period of time or during a thunder/lightning storm. • This product contains Fluorinated Greenhouse Gases covered by the Kyoto Protocol, the refrigerant gas being in a hermetically sealed system. Refrigerant gas: R410a has a Global Warming Potential (GWP) 2087.5.

SAFEGUARDING THE ENVIRONMENT SCRAPPING OF APPLIANCE

• This appliance is marked according to the European Directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE).

• This appliance has been made of recyclable or re-usable material. Scrapping must be carried out in compliance with local waste disposal regulations. Before scrapping it, make sure to cut off the mains cord so that the appliance cannot be re-used.

• For more detailed information on handling and recycling of this product, contact your local authorities who deal with the separate collection of rubbish or the shop where you bought the appliance.

• By ensuring that this product is disposed of correctly, you will help to prevent potentially negative consequences for the environment and for human health.

• The symbol on the product or on the documents accompanying the product indicates that this appliance should not be treated as household waste, but must be given to the appropriate local gathering place where electric and electronic appliances are stored and recycled.

SCRAPPING OF PACKAGING

• The packaging can be 100% recycled as confirmed by the recycling symbol . The various parts of the packaging must not be dispersed in the environment, but must be scrapped in line with local authority regulations.

This section explains proper local air conditioner operation.

NOTE: When the air conditioner is turned on for the first time after it is plugged in, it will run in the

6th Sense Mode control. When the air conditioner is turned on at all other times, it will run according to the previous settings. 6th Sense Mode can be selected with the remote control only. Only if the unit is operated in UNLIKELY VERY HUMID air, water will be collected in the container inside the unit. If the water container is full, the air conditioner will stop. The water container is full, the air conditioner will stop. The screen will display "E5" to inform you to empty the internal container.

• The air conditioner display shows the setting temperature. • Only in standby mode the display shows the ambient temperature • When changing modes while the air conditioner is operating, the compressor will stop for 3 to 5 minutes before restarting. If a button is pressed during this time, the compressor will not restart for another 3 to 5 minutes. • In Cooling or Dry mode, the compressor and condenser fan will stop when the room temperature reaches the set temperature. NOTE: In the event of a power failure, your air conditioner will operate at the previous settings when the power is restored. 1. Select the mode. See "Mode." 2. Select the fan speed. See "Fan Speed." 3. Set the temperature. See "Temperature." 4. Press ON/OFF button to start the air conditioner.

STORAGE AND TIPS FOR USING THE RC How to insert the batteries

1 Insert a pin and gently press down on the battery cover and push in the direction of the arrow to remove, as shown. 2 Insert 2 AAA batteries (1.5V) into the compartment. Ensure that "+" and "-" polarity is correctly positioned. 3 Close the battery cover on the remote control. How to remove the batteries Remove the battery cover in the direction of the arrow. Press the positive pole of the battery softly with your fingers, then draw the batteries out of the compartment. All this should be done by adults, children are forbidden to remove the batteries from the remote control in order to avoid danger of swallow. Disposal of the batteries To protect natural resources and to promote material reuse, please separate batteries from other types of waste and recycle them through your local, free battery return system. Precautions • When replacing the batteries, do not use new batteries with old batteries, or different types of batteries as this may cause the remote control to malfunction. • If you do not expect to use the remote control for some time, take the batteries out to prevent leakage of battery acid in the remote control. • Operate the remote control within effective range. Keep the remote control at least 1 meter from any TV set or HI-FI equipment. • If the remote control does not work normally, take the batteries out and reinstall after 30 seconds. If it still does not work install new batteries. • To operate the appliance by remote control, point the remote control at the receiving device on the indoor unit, to ensure receiving sensibility. • To send a message from remote control, the symbol will flash for 1 second. On receipt of the message, the appliance will emit a beep. • The remote control will operate the air conditioner at a distance of up to 7m. • Each time the batteries are replaced in the remote control, the remote control is pre-set at Heat mode.

OPERATING MODE DESCRIPTION Filter Reset

1. When the Filter Reset indicator light is lit, remove, clean and replace the air filter. See "Cleaning the Air Filter." 2. Press and release FILTER button after replacing the air filter.

1. Press and release MODE until you see the symbol glow for the desired setting

2. Choose Cooling, Dry, Fan Only or Heating.

• Cooling-Cools the room. Press FAN to select High, Mid or Low. Press the Plus or Minus button to adjust the temperature.

NOTE: After 360 hours of fan operating time, the

Filter indicator light will turn on. It will remain on for 180 hours or until you press FILTER button. After 180 hours, it will turn off automatically.

• Dry-Dries the room. The air conditioner automatically selects the temperature. The fan runs on Low speed only.

• Press the PLUS button to raise the temperature. Press the PLUS button once to increase the set temperature by 1°C.

NOTE: Dry mode should not be used to cool the room.

• Fan Only-Only the fan runs. Press FAN to select High, Mid or Low.

• Press the down Adjust button to lower the temperature. Press the down Adjust button once to decrease the set temperature by 1ºC, or press twice to decrease the set temperature by 2ºC.

• Heating-Heats the room. Press FAN to select

High, Mid or Low. Press the PLUS or MINUS button to adjust the temperature. NOTE: Heating is NOT available for cooling only air conditioner.

• In the Cooling and Heating mode, the temperature can be set between 18ºC and 32ºC. • In Fan Only mode, the temperature cannot be set. • In Dry mode, press the PLUS/MINUS botton the set temperature change by 2ºC.

1. Press and release FAN to choose the desired fan speed.

2. Choose High, Mid or Low.

• High-for maximum fan speed HIGH

• Low-for minimum fan speed

REMOTE CONTROL FUNCTIONS AND INDICATORS

ON/OFF BUTTON Starts and/or Stops the appliance by pressing this button.

2. MODE BUTTON Used to select the operation mode. 3. FAN BUTTON Used to select fan speed in sequence auto, high, medium or low. 4-5. TEMPERATURE BUTTON Used to select the room temperature. Used to set time in timer mode and real time clock. 6. 6TH SENSE BUTTON Sets or cancels 6th sense operation. 7. SWING BUTTON Stops or starts horizontal adjustment louver swinging and sets the desired up/down airflow direction. 8. SLEEP BUTTON Sets or cancels Sleep Mode operation. 9. AROUND U BUTTON Used to set or cancel Around U function. 10. JET BUTTON Used to start or stop the fast cooling or heating. 11. TIMER BUTTON Used to set or cancel the timer on operation. Used to set or cancel the timer off operation. 12. DIM BUTTON Used to turn on or turn off display light on indoor unit.

INDICATOR SYMBOLS ON RC DISPLAY Cooling indicator

Display set temperature

FUNCTION DESCRIPTIONS Power On or Off

Press ON/OFF button to turn on or off the unit.

The air conditioner automatically selects Cooling or Dry mode,depending on room temperature and sets the target temperature.

• Changing the mode during operation. Sometimes the unit does not response at once,wait 3 minutes • Wait 3 minutes before restarting the appliance.

Operation mode and temperature are determined by indoor temperature.

Indoor temperature 21°C or below

21°C-23°C Selecting mode

1. Press and release MODE until you see the symbol glow for the desired setting. Mode

2. Choose Cooling, Dry, Fan Only or Heating.

• Cooling-Cools the room. Press Fan to select Auto, High, Mid or Low. Press the up or down Adjust button to adjust the temperature.

HEATING FAN ONLY Target temperature

23°C-26°C DRY Room temperature decrease 2°C after operating for 3 minutes

26°C Electric Heat models

Indoor temperature 21°C or below

• Dry-Dries the room. The air conditioner automatically selects the temperature. Fan runs on Low speed only.

NOTE: Dry mode should not be used to cool the room. At "Dry" mode, the unit can decrease or rise 2ºC(3°F or 4°F) if you still feel uncomfortable.

FAN ONLY Target temperature

23°C-26°C DRY Room temperature decrease 2°C after operating for 3 minutes

26°C Cooling only models

NOTE: Temperature, airflow and direction are controlled automatically in 6th Sense mode. However, a decrease or rise of up to 2°C can be set with the remote control if you still feel uncomfortable.

• Fan Only-Only the fan runs. Press FAN to select

NOTE: Auto fan speed cannot be selected in Fan

• Heating- Heaters the room. Press FAN to select the fan speed. Press the up or down button to select the temperature.

2. In Fan Only mode, press Fan to select High, Mid or Low.

Jet button is used for fast cooling or heating. NOTE: 6th Sense mode button does not operate when Jet function is selected. 1. Press Jet in cooling mode. The air conditioner automatically sets the fan speed and the temperature to 18°C. Fast heating operates at auto fan speed, changing the set terperature to 32ºC.

• Press the DOWN adjust button to lower the temperature. Press the DOWN adjust botton to decrease the set temperature by 1ºC, or press twice to decrease the set temperature by 2ºC.

• In the Cooling or Heating mode, the temperature can be set between 18ºC and 32ºC. • In Fan Only mode, the temperature cannot be set. • In Dry mode, press the UP/DOWN botton the set temperature change by 2ºC.

2. To exit Jet mode press any button except Timer

Around U and Swing button. Fan Speed 1. Choose desired fan speed.

When you press this button,the remote control transmits signal of the actual room temperature around it to the unit, and the appliance will operate according to this temperature to let you feel more comfortable.

Please keep the remote control in a location where it can transmit the signal to the unit properly. Press once to set and press again to cancel.

2. Each time the "FAN" button is pressed, the fan speed is changed in sequence:

Auto → High → Mid → Low ↑ • Auto-automatically controls fan speed depending on current room temperature and temperature control setting. NOTE: Auto fan speed cannot be selected in Fan Only mode.

Press Sleep button on remote control and the indicator in LCD lights up, the appliance operates in sleep mode and the fan speed is automatically set to low speed.

• High - for maximum cooling

• Mid - for normal cooling

• The appliance will stop operation automatically after operating for 8 hours. • Fan speed is automatically set at low speed.. • In Cooling mode if the current room temperature is below 26ºC, the temperature will automatically increase 1°C during the first hour after Sleep control is activated, then remain the same. • In Heating mode, the setting temperature will decrease by 3ºC at most for 3 hours constantly, then keeps steady.

• Low - for minimum cooling

• Press the UP adjust button to raise the temperature. Press the UP Adjust button once to increase the set temperature by 1ºC, or press twice to increase the set temperature by 2ºC.

1. Press MODE to select Cooling, Dry or Heating.

NOTE: Sleep mode cannot be selected when Fan Only is selected.

• The range can be set is 1 hour to 10 hours. • After setting a switch-on timer when the appliance is off, the Timer light on the control panel lights and • Setting a switch-off timer when the unit working, the Timer light of the control panel lights up.

2. Press the or button to set the temperature.

3. Press SLEEP. After 10 seconds, the lights on the control panel display will dim. NOTE: The temperature and airflow direction may be adjusted during Sleep control. The fan speed is automatically set to Low speed. After 10 seconds, the lights on the control panel display will dim again. 4. To turn off Sleep control, press SLEEP, MODE, FAN, ON/OFF or wait 8 hours for Sleep control to turn off automatically.

Changing Air Direction

Press SWING once to change vertical airflow direction. Press again to stop airflow louver at desired airflow direction.

Press the DIM button to turn off the light and the display in the unit.

When your air conditioner is operating normally, you may hear sounds such as: • Air movement from the fan. • Clicks from the thermostat cycle. • Vibrations or noise due to poor wall or window construction. • A high-pitched hum or pulsating noise caused by the modern high-efficiency compressor cycling on and off.

NOTES: When the light is off, receive signal will turn on the light again.

TIMER function It's convenient to set the timer on with TIMER button before you leave so that you will come back to the comfortable room temperature you set. Press the TIMER button to set a switch-on button when the appliance is off. Press the TIMER button to set a switch-off timer during operation.

1. Set desired operating mode, temperature setting and fan speed firstly, then press the TIMER button and "01h" flashed on LCD. 2. Set desired operating mode, temperature setting and fan speed firstly, then press the TIMER button and "01h" flashed on LCD. 3. Point the remote control at the signal receptor of the unit, press the + or – button when"01h" flashes. Choose the timer you want, then press the TIMER button. • A "beep" can be heard. • Timer indicator on the control panel lights up. • "h" stops flashing. 4. To cancel the set timer: press the TIMER button again, a "beep" can be heard.

MAINTENANCE A Draining the Air Conditioner

(in accordance with the indication of Water Full under "Starting your local air conditioner".) 1. Press ON/OFF to turn off the air conditioner. 2. Unplug air conditioner or disconnect power. 3. Move the appliance gently and stably to a draining location or outside to drain water. Do not move the unit before water is drained out completely. 4. Remove the secondary drain plug and drain water completely. 5. Remove the primary drain hose from the drain hose clip. Remove the drain hose plug from the end of the primary drain hose and drain water completely.

B A. Secondary drain plug

NOTE: If air conditioner will be stored after use, see "Storing After Use."

6. Reinstall the drain hose plug and the secondary drain plug. 7. Reattach the primary drain hose to the drain hose clip. 8. Reposition the air conditioner. 9. Plug in air conditioner or reconnect power. 10. Press ON/OFF to start the air conditioner. Cleaning the Air Filter 1. Press ON/OFF to turn off the air conditioner. 2. Open the filter panel door on the back of the air conditioner and remove it. 3. Remove the air filter from the filter panel door. 4. Use a vacuum cleaner to clean the filter. If filter is very dirty, wash filter in warm water with a mild detergent.

A. Filter panel door

B. Air filter Storing After Use 1. Drain the water (see the "Draining the Air Conditioner") 2. Run the air conditioner set to Fan Only for approximately 12 hours to dry the air conditioner. 3. Unplug air conditioner. 4. Remove flexible exhaust hose and store with air conditioner in a clean, dry area. See "Installation Instructions." 5. Remove window kit and store with air conditioner in a clean, dry area. See "Installation Instructions." 6. Remove the filter and clean. See "Cleaning the Air Filter." 7. Clean the outside of air conditioner. See "Cleaning the Outside." 8. Reinstall filter. 9. Remove the batteries and store the remote control with air conditioner in a clean, dry area.

NOTE: Do not wash filter in the dishwasher or use any chemical cleaners.

5. Air dry filter completely before replacing to ensure maximum efficiency. 6. Reattach the air filter to the filter panel door. 7. Reinstall filter panel door. 8. Press ON/OFF to start the air conditioner. Cleaning the Outside 1. Unplug air conditioner or disconnect from power. 2. Remove the air filter and clean separately. See "Cleaning the Air Filter." 3. Wipe outside of the air conditioner with a soft, damp cloth. 4. Plug in air conditioner or reconnect power. 5. Press ON/OFF to start the air conditioner.

TROUBLESHOOTING Before calling for service, try the suggestions below to see whether you can solve your problem without outside help.

• The power supply cord is unplugged. Plug into a grounded outlet. See "Electrical Requirements." • A household fuse has blown, or a circuit breaker has tripped. Replace the fuse, or Air conditioner does reset the circuit breaker. See "Electrical Requirements." • The On/Off button has not been pressed. Press ON/OFF. not operate • The local power has failed. Wait for power to be restored. • Time-delay fuse or circuit breaker of the wrong capacity is being used. Replace with a time-delay fuse or circuit breaker of the correct capacity. See "Electrical Requirements." • Too many appliances are being used on the same circuit. Unplug or relocate appliances that share the same circuit. Air conditioner • You are trying to restart the air conditioner too soon after turning off air blows fuses or trips conditioner. Wait at least 3 minutes after turning off air conditioner before trying circuit breakers to restart it. • You have changed modes. Wait at least 3 minutes after turning off air conditioner before trying to restart the appliance.

Air conditioner seems to run too much

• Is there a door or window open? Keep doors and windows closed.

• In cooling mode: the air conditioner is in a heavily occupied room, or heat producing appliances are in use in the room. Use exhaust vent fans while cooking or bathing and try not to use heat producing appliances during the hottest part of the day. Local air conditioners are designed as supplemental cooling to local areas within a room. A higher capacity air conditioner may be required, depending on the size of the room being cooled. • In heating mode: the air conditioner is in a very cool room. Local air conditioners are designed as supplemental heating to local areas within a room. A higher capacity air conditioner may be required, depending on the size of the room being heated up.

Air conditioner runs for a short time

• Set temperature is close to room temperature. Lower or Higher set only, but room is temperature. See "Operating mode description". not cool or hot • If the unit display error code E5, it is water full in the unit, you should drain the Display error code water, see "Draining the air conditioner". After draining, you can operate the unit. • If the unit display error code E1/E2/E3/E6/E7/EA, please contact customer service. • The filter is dirty or obstructed by debris. Clean the filter. Air conditioner runs, • Air outlet is blocked. Clear air outlet. but does not • The setting temperature is not compatible. In cooling mode: set temperature is cool/hot too high. Lower set temperature. In heating mode: set temperature is too low. Higher set temperature. • The air conditioner is not properly sized for your room. Check the cooling/heating capabilities of your local air conditioner. Local air conditioners are designed as supplemental cooling/heating to local areas within a room. • The filter is dirty or obstructed by debris. Clean the filter. • In cooling mode there is excessive heat or moisture (open container cooking, Air conditioner showers, etc.) in the room. Use a fan to exhaust heat or moisture from the cycles on and off too room. Try not to use heat-producing appliances during the hottest part of the day. much In heating mode the temperature of the environment is too high. Do not use your air conditioner when the temperature of the environment is too high. • The louvers are blocked. Install the air conditioner in a location where the louvers are free from curtains, blinds, furniture, etc. • The outside temperature is below 18°C. Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 18°C.

INSTALLATION REQUIREMENTS Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. 1. Tools needed • Phillips screwdriver • Saw • Cordless drill and 1/8'' bit • Scissors • Pencil 2. Parts Supplied The company provides only one plan to install local air conditioner. See "Install local Air Conditioner".

A. Flexible exhaust hose

B. Window exhaust adapter C. Outer slider section D. Rain Cover E. Inner slider section

Location Requirements

NOTES: • The flexible exhaust hose allows placement of the air conditioner between 23¹⁄₂" and 67" (60 cm and 170 cm) from window or door. • Local air conditioners are designed as supplemental cooling to local areas within a room. • To ensure proper ventilation, keep the required distance from the return air outlet to the wall or other obstacles at least 23¹⁄₂" (60 cm). • Do not block air outlet. • Provide easy access to grounded outlet.

Vertical Slide Window

Electrical Requirements

• The local air conditioner should be connected to a 220-240V / 50Hz, 20-amp fused grounded outlet. • The use of a time-delay fuse or time-delay circuit breaker is recommended. • All wiring must comply with local and national electrical regulations and be installed by a qualified electrician. If you have any questions, contact a qualified electrician.

Horizontal Slide Window

Use your power supply cord: Plug power supply cord into a grounded outlet. NOTES: • A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.

INSTALLATION INSTRUCTIONS Unpack the Air Conditioner

Remove packaging materials • Remove and dispose of/recycle packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry. • Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner. Install Local Air Conditioner Install Exhaust Hose and Adapter 1. Open the window. 2. Measure the window opening. • If the window opening is too narrow for the window slider kit, remove the inner slider from the window slider kit.

4. Use a special plastic device with spring to fix the window brackets: Place the device to the position A, the pin may stretch out then lock the brackets, when place the device to position B, the pin will draw back and the brackets will be released the window slider kit.

• Using a saw, cut the inner slider section to fit the window opening.

• Slide the inner slider section into the outer slider section of the window slider kit. 3. Place the window slider kit into the window, extending it to fit the width of the window. Be sure the rain cover is on the outside of the window.

5. Close the window onto the window slider kit to secure.

A To local air conditioner

B Outdoors C Rain cover D Window slider kit E Window exhaust adapter F Flexible exhaust hose

NOTE: For casement window installation, the window slider kit may be installed vertically with the window slider kit opening at the bottom.

Install Exhaust Hose and Adapter

1. Roll the air conditioner to selected location. See "location Requirments". 2. Attach the window exhaust adapter to the flexible exhaust hose. Turn anticlockwise until securely locked into place.

Rain Cover Installation

Attach the rain cover to the holes of the outer slider section. Then slide the rain cover until securely locked place. Vertical Installation Horizontal Installation

B B B A. Out slider section

A Flexible exhaust hose

B Window exhaust adapter

Complete Installation

1. Place the window-lock bracket on top of the lower window and against the upper window sash. 2. Use 1/8" drill bit to drill a starter hole through the hole in the bracket. 3. Attach the window-lock bracket to the window sash with wood screw(provdie 4) to secure the window in place.

3. Insert the dummy coupling into the slot on the back of the air conditioner.

4. Put and rotate to lock the hose into place.

A B A. Flexible exhaust hose

Window Installation 1. Your window slider kit has been designed to fit most standard vertival and horizontal window applications. Roll the air conditioner to selected location. See "Location Requirements". 2. Insert the window exhaust adapter into the slot on the window slider kit.

A. Upper window sash

B. Window-lock bracket 4. Insert the foam seal behind the top of the lower window sash and against the glass of the upper window.

A A B B A.Window slider kit

B.Window exhaust adapter

A. Top of lower window sash

AFTER SALES SERVICE If repair work has to be carried out, contact the

Customer Care Centre (Use of original spare parts and a proper repair is guarenteed). You will need to present the original invoice. Failure to comply with these instructions could compromise the safety and quality of your product.

Before contacting the Customer Care Centre:

1. Try to solve the problem yourself based on the descriptions given in the "Troubleshooting". 2. Turn the appliance off and restart it to see if the fault persists. If after carrying out the above checks, the fault persists, contact the Customer Care Centre. Please give: • a short description of the fault; • the exact model of the air conditioner; • the service number (this is the number found after the word Service on the rating plate), located on the back of the appliance. The service number can also be found in the warranty booklet; • your full address; • your telephone number.

INDICATORSYMBOLEN OP DISPLAY AFSTANDSBEDIENING Indicator 6th Sense

Indicator Around U Spia “Around U”

STARTE DET LOKALE KLIMAANLEGGET FILTER HEAT

2. Velg High, Mid eller Low.

• High - for maks. viftehastighet HIGH

• Mid - for normal viftehastighet

MID Vis timer-innstilling

Middels viftehastighet

Indikator for Around U Indikator for Jet

KAUKOSÄÄTIMEN TOIMINNOT JA KUVAKKEET

FUNKCJE I WSKAŹNIKI PILOTA

(OGRZEWANIE) FAN ONLY (TYLKO WENTYLACJA)

Temperatura docelowa

23°C-26°C DRY (OSUSZANIE)

Whirlpool® Registered trademark/TM Trademark of Whirlpool group of companies - © Copyright Whirlpool Europe s.r.l. 2015. All rights reserved - http://www.whirlpool.eu