USER MANUAL ModuLine IV Nefit
Instructions for use
External Error Detection – EED
Instructions for use
External Error Detection (EED) 12
This appliance is in conformance with the requirements of the applicable European directives.
Conformity has been substantiated by the proper documents which - together with the declaration of conformity - are filed with the manufacturer.
text_image
Technical diagram of a mechanical assembly with numbered components and screwdriver toolFig. 2 Wandbevestiging van de EED-module
Aansluiten
line
| [V] | Temperature (°C) | | --- | ---------------- | | 0 | 15 | | 6 | 50 | | 9 | 75 |text_image
Technical diagram of a mechanical assembly with numbered components and screwdriver toolline
| [V] | Temperature (°C) | | --- | ---------------- | | 0 | 15 | | 6 | 50 | | 9 | 75 |Abb. 60 - 10 V Charakteristik
Instructions for use External Error Detection (EED)
Function of the EED
● The EED module can be connected to a central heating boiler with a UBA-control.
● The EED module displays a fault message in the event of boiler malfunction.
- The EED module also provides the option of transmitting an external signal by means of a potential-free port (make-and-break contact) in the event of that the appliance malfunctions and in case of a power failure.
● The EED module does not react to malfunctions in external controls connected to the boiler.
● The EED module can be connected to one boiler.
Switch SI "Lock" and "No Lock" (see figure 1)
In the "No Lock" position, a fault message is only displayed in the event of a malfunction in the locking mechanism.
The display on the boiler will flash. This can be reset with the UBA reset button.
The EED module will display a fault message in the "Lock" position in the event:
- of a malfunction in the locking mechanism. This can be reset by means of the UBA reset button.
- that the boiler is not activated within two hours of a heat demand. This malfunction can be reset with the EED reset button. The UBA reset does not influence this.
- that the boiler is blocked five times during these two hours. This malfunction can also be reset with the EED reset button.

text_image
LOCK No Loop Error RESET CON 2 CON 1 1 2 1 2 3 4 CON 3 3 2 1 UBAFig. 1 Switch "Lock" and "No Lock"
Fitting
The EED module is attached to the wall by two screws. Use the back plate to mark the position of the drill holes. Remove the transparent hood before fitting (see figure 2).

text_image
Technical diagram of a mechanical assembly with numbered components and screwdriver toolFig. 2 The wall attachment of the EED module
Connecting
The switching unit is connected to the terminal board of the boiler with a four-core cable (see figure 3).

WARNING!
Check UBA screw clamp connections 3 and 4; they must be bridged.
| From the EED module to the terminal board | ||
| No. | Description Number of the clamp | |
| 1. 2 | 4 VAC 9 | |
| 2. 0 | V 10 | |
| 3. UBA loop 6 | ||
| 4. UBA loop 5 | ||
Table 1 Connecting the four-core cable

flowchart
graph TD
A["CON 1"] -->|24VAC OV| B["UBA-LOOP"]
A --> C["3 4 5 6 9 10 11"]
A --> D["24 VAC 5 0 VAC 0V 6"]
style A fill:#f9f,stroke:#333
style B fill:#ccf,stroke:#333
style C fill:#cfc,stroke:#333
style D fill:#fcc,stroke:#333
Fig. 3 Connecting by means of the four-core cable

WARNING!
If the EED module is connected incorrectly, it could damage the EED module and the boiler!
Subject to changes due to technical improvements!
English External Error Detection (EED)
A potential-free port (make-and-break contact) CON3 is provided (see figure 4). This can be used for an electronic fault message.
1 and 2 are for normal operation
3 and 2 break the circuit
Fault message
When the malfunction light flashes at one second intervals, it means that the boiler is malfunctioning.
Press the reset button on the boiler for three seconds. The machine restarts. If it malfunctions immediately, press the reset button again. If it malfunctions again and these malfunctions continue, call your fitter.
● Slow flashing is one second on one second off.
● Rapid flashing is on and off several times a second.
0 - 10 V connection
It is possible to use a non-resident control voltage of 0 - 10V (decent voltage) for controlling the boiler.
Connect to the clamps 1 and 2 of the CON 2, see figure 5.

WARNING!
The external control voltage determines the supply water temperature. This is not affected by the UBA setting. The external control has to be adjusted to limit the supply water temperature. See the instructions with the external control.

text_image
LOCK No Loop Error RESET CON 2 CON 1 1 2 1 2 3 4 CON 3 3 2 1 UBAFig. 4 External fault message

text_image
LOCK No Loop Error RESET CON 2 CON 1 1 2 1 2 3 4 CON 3 3 2 1 UBAFig. 50 - 10V connection
Subject to changes due to technical improvements!
| Voltage Temperature supply water | |
| 0,6 V ± 15 °C boiler on | |
| 0,5 V | ± 14 °C boiler off |
| 5,0 V | ± 50 °C |
| 10,0 V | ± 90 °C maximum |
See for more information figure 6.

line
| [V] | Temperature (°C) | | --- | ---------------- | | 0 | 15 | | 6 | 50 | | 9 | 75 |Fig. 60 - 10 V charakteristik
| Malfunction light "No Loop" | Malfunction light "Error" | Type of malfunction Repairing the malfunction |
| Off Fast flashing Malfunction in the EED module Call the fitter | ||
| Off | Slow flashing | Blocking or locking malfunction in the boiler or activated hot water tank |
| On | Off | EED attempting to re-establish contact |
| On | Slow flashing | No loop between EED and boiler |
Table 2 Description of malfunctions
Subject to changes due to technical improvements!
text_image
Technical diagram of a mechanical assembly with numbered components and screwdriver toolline
| [V] | [°C] | | --- | ---- | | 0 | 15 | | 6 | 50 | | 9 | 75 |text_image
Technical diagram of a mechanical assembly with numbered components and screwdriver toolline
| [V] | °C | | --- | --- | | 0 | 15 | | 6 | 50 | | 9 | 75 |Fig. 60 - 10 V caratteristiche
Spínač SI "Lock" a "No Lock" (→ obr. 1)
Obr. 1 Spínač "Lock" a "No Lock"

text_image
Technical diagram of a mechanical assembly with numbered components and screwdriver for identificationline
| [V] | [°C] | | --- | ---- | | 0 | 15 | | 5 | 50 | | 9 | 80 |Obr. 6 Charakteristika 0 - 10 V
Prepínač SI "Lock" a "No Lock" (→ obr. 1)
text_image
Technical diagram of a mechanical assembly with numbered components and screwdriver, showing exploded view and assembly steps.Obr. 2 Pripevnenie modulu EED na stenu
Pripojenie
text_image
Warning sign with exclamation mark inside a trianglePOZOR:
line
| [V] | Temperature (°C) | | --- | ---------------- | | 0 | 15 | | 6 | 50 | | 9 | 75 |Obr. 6 Charakteristika 0 - 10 V