KH 311 HAND-HELD INFRARED MASSAGER - Massage device SILVERCREST - Free user manual and instructions

Find the device manual for free KH 311 HAND-HELD INFRARED MASSAGER SILVERCREST in PDF.

📄 50 pages English EN Download 💬 AI Question
Notice SILVERCREST KH 311 HAND-HELD INFRARED MASSAGER - page 4

User questions about KH 311 HAND-HELD INFRARED MASSAGER SILVERCREST

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

L'email reste privé : il sert seulement à vous prévenir si quelqu'un répond à votre question.

No questions yet. Be the first to ask one.

Download the instructions for your Massage device in PDF format for free! Find your manual KH 311 HAND-HELD INFRARED MASSAGER - SILVERCREST and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. KH 311 HAND-HELD INFRARED MASSAGER by SILVERCREST.

USER MANUAL KH 311 HAND-HELD INFRARED MASSAGER SILVERCREST

Safety instructions Intended use Technical data Appliance description Items supplied Utilisation Taking into use Unpacking.… Adijusting the rotatable parts of the massage appliance Equipping the massage head with accessories Usage Switching on. Massage. Ending usage

Switching off … Storage Cleaning Non-functionality Disposal Warranty & Service Nllollollollollenl i, lent, &,lenl À À À lnllinlcole||co||e Importer Read the operating instructions carefully before using the appliance for the first time and preserve this booklet for later reference. Pass the manual on to whomsoever might acquire the appliance at a later date.

IB_KH311 37679 LB3 14.09.2009 14:06 me e 2 HAND-HELD INFRARED MASSAGER KH311 Safety instructions PAN Danger of electric shock! +_ Connect the appliance only to correcily installed and properly earthed power sockets. Ensure that the rating of the local power supply tallies com- pletely with the details given on the rating plate ofthe appliance. +_ Always remove the plug from the wall socket when you attach accessories, in the case of malfunctions, before cleaning the appliance and when it is no longer required for use. + NEVER submerse the appliance in liquids. Should liquids nonetheless permeate into the appliance housing, immediately remove the plug from the wall socket. Arrange for it to be repaired by a qualified specialist. DO NOT use the appliance in the bath, in the vicinity of waterilled baths, swimming pools or washbasins. + NEVER grasp the appliance, power cable or power plug with wet hands. + Always remove the power cable from the socket by pulling on the plug, do not pull on the cable itself. Do not hold or carry the appliance with he power cable. + Do not fold or crush the power cable. Ensure that the power cable does not run over sharp edges. +_ Always check the power cable and plug before use. To reduce risks in the event of damage to the power cable, arrange for it to be examined and repaired as soon as possible by the manu- facturer, by Customer Services or by a similarly qualified person. À Risk of Fire! +_ Do not leave the appliance unattended when in use. To avoid a build-up of heat, NEVER cover the appliance or the ventilation openings when it is in use. Do not use the appliance under a blanket or at other poorly ventilated locations. Avoid the addition of heat from other sources e.g. from direct sunlight, heating appliances, other devices etc.l +. Do not use an extension cable. In the event of danger, the plug must be quickly and easily accessible. À Risk of personal injuries! +_ Do not allow individuals (including children) to use the appliance whose physical, sensorial or mental abilities or lack of experience and know- ledge hinder their safe usage of if they have not previously been supervised or instructed in its correct usage. Tell children about the appliance and its potenti- al dangers so that they do not play with it. +_ Lay the power cable in such a way that no one can tread on or trip over it. À Medical Warning Note This Infra Red Massage Appliance is intended for personal use and is not a substitute for physiothera- peutic or medicinal treatments. The appliance may not be used … by people fitted with heart pace-makers by people with heart problems or pains of unknown origin in the event of feverish colds, varicose veins, thrombosis, phlebitis, jaundice, diabetes, nerve ailments such as sciatica, acute inflammations or during pregnancy. on swollen, inflamed or injured body parts. for the massage of bones, especially the spine and the skull. close to the eyes or other sensitive body parts. on small children.

If you are unsure about your current medical condi- tion, obtain advice from your doctor before using the Infra Red Massage Appliance. À Notices regarding usage +_ Utilise the appliance exclusively for the purposes and usages described in these operating instructions. To avoid an overheating ofthe appliance, do not use it for more than 20 minutes continvously. Before re-using it, allow the appliance to cool down for approx. 15 minutes. Use the appliance exclusively with the supplied accessories. Do not use the appliance outdoors. Do not use the appliance on animals. Do not use the appliance to fall asleep in bed. There is a risk of suffering burns or causing a fire. À ATTENTION! The upper surface of the infra red lamp becomes warm when in use. Heat non-sensitive people must therefore handle the appliance with particular caution. Intended use This appliance is intended for the relaxation and stimulation of muscle mass through massage. The appliance is intended exclusively for domestic use. Technical data 220-240V- 50 Hz 13W 1/[E] Mains voltage: Power consumption: Protection class: Appliance description © Massage head with massage accessory @ Grip cavity to release accessory © Revolvable ring © Switch INFRARED @Æ © Switch MASSAGE @ Power cable @ Grip © Locking button for swing arm © Infra red lamp @ Roller accessory @ Nub accessory @ Surface accessory ©® Shiatsu accessory @ Knead-massage accessory ® Accessory for exacting massage Items supplied Infra Red Massage Appliance Roller accessory Nub accessory Surface accessory Shiatsu accessory Knead-massage accessory Accessory for exacting massage Operating instructions Before taking the appliance into use, check that all items are present and free of visible damage.

Utilisation In use, the infra red lamp @ creates warmth and it penetrates into the deeper layers of skin. This has a stimulating effect and is thus effective against tiredness and tensions. With vibration switched on in the massage head @, a relaxing and pain relieving effect can be achie- ved for tired muscles through gentle massage. Taking into use Unpacking + Take the Infra Red Massage Appliance and the accessories from the packaging. + Remove all packaging material. À Attention: Do not permit small children to play with plastic packaging. There is a risk of suffocationl Adjusting the rotatable parts of the massage appliance

+ With the revolvable ring @ the massage head © con be turned through a radius of 270°. The grip @ can be tumed in five levels over a radius of 90°. + For this, press the locking button on the swing arm @ down and move the grip @- +_ Release the locking button @ and turn the grip @ uniil it engages. Equipping the massage head with accessories Select, according to the application requirement, an accessory (®, ®. ®. ®, ®. E) for the massage: The roller accessory Q: Stimulates the blood circulation. Guide the roller accessory back and forth over the whole of the body. The nub accessory Q: The 21 nubs are suitable for deep massage and large muscle groups. The surface accessory @: Use this accessory on the whole body to relieve muscle pain and tensions. The Shiatsu accessory : The Shiatsu accessory simulates the finger posture of a masseur and is suitable for deep massage. The knead-massage accessory @: This accessory is suitable for kneading simulation and deep massage. The accessory for exacting massage @: Use this accessory for the massage of individual muscle groups.

1. Release a possibly fitted accessory from he

massage head @), in that you hold the grip cavity @ and pull it off. . Place the accessory (®, @. ®. ®. ®. E) cf your choice on the massage head @ and pay

attention that the round curbs of the massage head @ and the accessory (D, @. @. ®. ©. ©] lie one on top of the other. Thus either the infra red lamp @ or the massage 3. Push the accessory (@, ®. ®. ®. D. } onto head @ is directed at the body part to be treated. the massage head then check to make sure that it is irmly fixed. -4.

IB_KH311 37679 LB3 14.09.2009 14:06 me e 5 Usage +_ Insert the power plug into a wall power socket. Switching on +_ To switch on the Infra red lamp slide the switch INFRARED @Æ @ into the position "l". *_ Slide the switch MASSAGE @ into the position "l" for normal vibration. +. For a stronger vibration slide the switch MASSAGE @ into the position "Il". MASSAGE À ATTENTION! After an extended heating-up of the infra red lamp © without bodily contact, the temperature of the lamp can be perceived as unpleasantly high! Al- ways check the temperature of the infra red lamp © with the tip of a Finger before making contact With the body itself. A temperature that is too high can be reduced by switching the infra red lamp @ off for a short period. Massage + _ Hold the Infra Red Massage Appliance by the grip @ and, dependant on the application, place the infra red lamp @ or the massage head @ against the skin. + Guide the infra red lamp @ or the massage head @ in circular or straight movements slowly over the skin. + Massage without applying undue pressure. +_ To achieve an optimal effect, try to keep the skin taut. + Always start the massage at the position furthest from the heart and then slowly work towards the heart. Ending usage Switching off +_ After use, dependant on the application, return the switches INFRARED @% @ and MASSAGE @ back into the position "O". + Remove the plug from the wall power socket. À WARNING! After use do not lay the Infra Red Massage Appli ance down with the infra red lamp @ facing down- wards! lt could still be hot and there is still a grave risk of firel + When laying it down always ensure there is sufficient safety distance between the massage appliance and inflammable objects such as curtains, tablecloths etc. + _ Remove the accessories (®, ®. ®, ®. ©. ®) from the massage head @ and lay the massage appliance with the flat area of the massage head @ facing downwards. À ATTENTION! For approx. 15 minutes after the last usage do not leave the appliance without supervision. Storage + Allow the Infra Red Massage Appliance to cool sufficienily after the last usage then store it in a carton or in a cool and dry location.

IB_KH311 37679 LB3 14.09.2009 14:06 me e 6 À ATTENTION! When storing it, do not wrap the power cable around the appliance. The cable could become da- maged. Do not hang the appliance up by the cable. Cleaning The appliance and the accessories should be cleaned regularly and after each usage. À Danger of electrical shock! Before cleaning, ALWAYS remove the plug from the wall power socket. ŒDNiever submerge the appliance in water. À ATTENTION! Always wait until the infra red lamp @ has cooled down before cleaning the appliance. + Clean your Infra Red Massage Appliance only With neutral detergents and a moist, soft cloth. + Clean the accessories (D, D, . ®, ®. E) in a warm soapy solution. Before taking the appliance back into use, check to ensure that it and the accessories are completely dry. Non-functionality +_ Do not attempt to dismanile the appliance or to carry out repairs yourself. You could potentially damage the sensitive electronic components. + Repairs to your appliance are to be carried out exclusively by qualified service personnel or by Customer Services! + No liability will be accepted for damage resul- ting from improper use and/or the opening of the appliancel +_Inthe event of a malfunction please make con- tact with our service partner in your country. Disposal D: Do not dispose of the appliance in your normal domestic waste. This product is subject to the European guideline 2002/96/EC. Dispose of the appliance through an approved dis- posal centre or at your community waste facility. Observe the currently applicable regulations. In case of doubt, please contact your waste disposal centre. Dispose of all packaging materials in an environmentally responsible manner. Warranty & Service The warranty for this appliance is for 3 years from the date of purchase. This appliance has been manufactured with care and meticulously examined before delivery. Please retain your receipt as proof of purchase date. Should a claim need to be made under the warranty, please make contact by tele- phone with our service department. Only in this way can a postfree despatch for your goods be assured. The warranty covers ONLY claims for material and maufacturing defects, not for wearing or consuma- ble or for damage to fragile components. This pro- duct is for private use only and is not intended for commercial applications. The warranty will become void in the event of abusi- ve and improper handling, use of force and internal tampering not carried or approved by our authori- zed service branch. Your statutory rights are not restricted in any way by this warranty.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SILVERCREST

Model : KH 311 HAND-HELD INFRARED MASSAGER

Category : Massage device