CH-400-BK - Range hood Heinner - Free user manual and instructions
Find the device manual for free CH-400-BK Heinner in PDF.
| Brand | Heinner |
| Model | CH-400-BK |
| Product Type | Traditional cooker hood |
| Suction Power | 326.4 m³/h |
| Motor Power | 2 x 60W |
| Color Options | White, Black, Brown, Inox |
| Energy Efficiency Class | C |
| Annual Energy Consumption | 56.6 kWh |
| Fluid Dynamic Efficiency Class | E |
| Lighting Efficiency Class | A |
| Grease Filtering Efficiency Class | C |
| Airflow (Min/Max) | 151.9 / 326.4 m³/h |
| Noise Level (Min/Max) | 56 / 71 dB(A) |
| Power Consumption (Off Mode) | 0 W |
| Voltage / Frequency | 220-240V ~ 50Hz |
| Installation Distance | 65 – 75 cm above cooking surface |
| Filter Type | Metal grease filter |
| Filter Cleaning | Hand wash (40-50°C) or dishwasher (60°C) |
| Light Type | Max 2W LED bulb |
| Control Type | Push buttons (Low, Medium, High, Light) |
| Ventilation Modes | Horizontal (back) and vertical (top) |
| Package Contents | Hood, user manual, warranty card |
| Weight | Not specified |
Frequently Asked Questions - CH-400-BK Heinner
User questions about CH-400-BK Heinner
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Range hood in PDF format for free! Find your manual CH-400-BK - Heinner and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CH-400-BK by Heinner.
USER MANUAL CH-400-BK Heinner
natural_image
Technical line drawing of a mechanical component on a brick wall (no text or symbols)Metoda B
natural_image
Technical line drawing of a mechanical device with two circular components and a central handle (no text or symbols)A

natural_image
Simple line drawing of a rectangular box with a circular hole and directional arrows, no text or symbols present.C
PIC5

natural_image
Technical line drawing of a device interior with two circular components and a red logo (no text or symbols)B

natural_image
Simple line drawing of a rectangular object with a circular hole and three vertical arrows pointing downward (no text or symbols)D
V. UTILIZARE
- Pozitia "0" – hota va fi oprita
- Butoanele "low", "middle" and "high" vor actiona motorul sa functionze la viteza mica, medie si, respectiv, mare
- Daca apasati o data butonul "light", lumina se va aprinde. Pentru a stinge lumina, mai apasati o data.

VI. CURATARE SI MENTENANTA
natural_image
Technical line drawing of a mechanical assembly with two internal components and directional arrows indicating motion (no text or symbols)natural_image
Technical line drawing of a mechanical assembly with internal components and a magnified inset showing rotational motion (no text or symbols)VII. FISA TEHNICA
| Capacitate absorbtie: | 326.4m3/h |
| Motor | 2x60W |
| Culoare: | Alb/maro/negru/inox |

MASURI PENTRU PROTECTIA MEDIULUI
Copyright © 2013 Network One Distribution. All rights reserved.
http://www.heinner.com, http://www.nod.ro

natural_image
White air conditioner unit with ventilation grille and control panel (no visible text or symbols)
natural_image
Black overhead air conditioner unit with ventilation slots and mounting bracket (no text or symbols visible)
natural_image
Brown industrial ventilation cover with ventilation slots and ventilation duct (no text or symbols visible)• Traditional cooker hood
• Suction power: 326.4 m³/h
• Color: white/ black/ brown/ inox
Thank you for purchasing this product!
I. INTRODUCTION
Before using the appliance, please read carefully this instruction manual and keep it for future reference.
This instruction manual is designed to provide you with all required instructions related to the installation, use and maintenance of the appliance.
In order to operate the unit correctly and safety, please read this instruction manual carefully before installation and usage.
II. CONTENT OF YOUR PACKAGE
▶ Traditional cooker hood
User manual
Warranty card
i
III. SAFETY PRECAUTIONS
If this product has arrived damaged please return for change or repair.
DO NOT INSTALL THIS APPLANCE IF YOU FOUND IT DANAGED.
Children should be supervised to ensure that they do not play with the appliance.
This appliance is designed for domestic use only.
Any installation work must be carried out by a qualified electrician or competent person.
There is a fire risk if cleaning is not carried out in accordance with the instructions.
Details concerning the method and frequency of cleaning are stated in the section.
"INSTALLATION AND MAINTENANCE".
Do not pull on the connection cord, but rather on the plug, to separate the appliance from the mains.
When cleaning the appliance, it must be off power first.
IV. INSTALLATION
INSTALLATION
Method A
- The cooker hoods should be placed at a distance of 65-75cm from the cooking surface for best effect.
- To install onto the wall, drill 4 holes of ∅ 8mm on a suitable place according with the center distance of hole in the back of the cooker hood.
- Insert the nut into the holes.
- Insert the screws into the nuts and tight
- Put up the cooker hood onto the fixed screws
- Then use the attached accessories enclosed to turn the screws into the two holes of inside the hood, and then fix the screws to tighten the hood onto the wall.
- Put the one way valve onto the cooker hood.

Pic 1

Pic 2

natural_image
Technical line drawing of a mechanical housing or enclosure with mounting holes and internal components (no text or symbols)Pic 3

natural_image
Line drawing of a flat-screen computer monitor with two ports and a grid background (no text or symbols)Pic 4
Method B
1) Drill 4 holes of ∅ 6mm at the bottom of the hanging Cup board.
2) Put the one way valve on the cooker hood, then install the cooker hood on the bottom of the cupboard, tighten the hood with enclosed 6 screws.
3) Install the adjusted board on the bottom of the hood in order to keep out the gap between hood back and cupboard.

Notice
There are 2 methods for ventilation, including 'horizontal ventilation' and 'vertical ventilation'. Please pay attention to the ventilation method when installation.
Horizontal ventilation: As shown in pic. 4A, please use the cover to seal the outlet on the top, then the air can be vented from back.
Vertical ventilation: As shown in pic 4B, please use the cover to seal the outlet on the back, then the air can be vented from top.

natural_image
Simple line drawing of a rectangular electronic device with two circular arrows indicating upward motion, labeled 'A' at bottom (no text or symbols on the device itself)
natural_image
Technical line drawing of a rectangular electronic device with a circular opening and labeled component B (no text or symbols beyond labels)Pic 6

natural_image
Diagram showing airflow or ventilation between two building walls, one with a pipe and arrow indicating direction (no text or symbols)Air ventilation setting
Outdoor air ventilation: Turn the adjuster to outdoor position (pic.5A), install the outlet, turn on the cooker hood, then the air will be vented from the outside outlet.
Indoor air ventilation: Turn the adjuster to indoor position (pic.5B), install the outlet cover, turn on the cooker hood, then the air can be vented from the inside outlet.

natural_image
Technical line drawing of a device with two circular components and directional arrows, labeled A and C (no text or symbols present)PIC5

natural_image
Technical line drawing of a device with labeled components and directional arrows (no text or symbols)V. OPERATION
The switch is operated as below (see pic. 6):
- Press "0", the motor will be off.
- Press the button to "low", "middle" and "high", the motor will be turned on at "low", "middle" and "high" speed respectively.
- Press "light", the light will be on. Press it again, the light will be off.

VI. CLEANING AND MAINTENANCE
Changing and cleaning the filter

natural_image
Technical line drawing of a mechanical or architectural component with internal compartments and directional arrows indicating motion (no text or symbols)- Put the filter into the water of 40-50°C, put some detergent in, and leave it for 2-3 minutes. Then use the soft brush to clean it with proper strength, in order not to damage the filter.
- The filter can be cleaned by dish washer. Put the filter into the dish washer and put some detergent in, then turn the temperature to 60^ C.
All the filters are made of metal. Please do not use any corrosive detergent when cleaning. Notice: Please unplug before cleaning.
Changing the light

natural_image
Technical line drawing of a mechanical assembly with internal components and a magnified inset showing internal flow direction (no text or symbols)*Before changing the lights, make sure that the appliance is plugged off.
*Open the filter, see beside picture.
*Change the bulb with Max. 2W LED bulb.
*Replace the filter to the original position.
AC 220-240V/50Hz

Environment friendly disposal
You can help protect the environment!
Please remember to respect the local regulations: hand in the non-working electrical equipment's to an appropriate waste disposal center.

HEINNER is a registered trademark of Network One Distribution SRL. Other brands and product names are trademarks or registered trademarks of their respective holders.
No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from NETWORK ONE DISTRIBUTION.
Copyright © 2013 Network One Distribution. All rights reserved.
www.heinner.com, http://www.nod.ro

This product is in conformity with norms and standards of European Community
Importer: Network One Distribution
Marcel Iancu Street, no 3-5, Bucharest, Romania
Tel: +40 21 211 18 56, www.heinner.com, www.nod.ro
| Product fiche | |
| Trademark | Heinner |
| Model | CH-400, CH-400-BK, CH-400-BRW, XCH-450S |
| Annual energy consumption (kWh/year) | 56.6 |
| Energy efficiency class | C |
| Fluid dynamic efficiency | 11.6 |
| Fluid dynamic efficiency class | E |
| Lighting efficiency (lux/W) | 35.5 |
| Lighting efficiency class | A |
| Grease filtering efficiency (%) | 75.6 |
| Grease filtering efficiency class | C |
| Airflow at minimum and maximum speed under normal conditions of use (m3/h) | 151.9/326.4 |
| Airborne acoustical A-weighted sound power emissions at minimum and maximum speed under normal conditions of use (dB(A)) | 56/71 |
| Power consumption in standby mode (W) | - |
| Power consumption in off mode (W) | 0 |
HEINNER
natural_image
White air conditioner unit with ventilation grille and control panel (no visible text or symbols)
natural_image
Black industrial air purifier with ventilation slots and mounting bracket (no text or symbols visible)
natural_image
3D rendering of a brown portable air vent or hood device with ventilation slots and ventilation grilles (no text or symbols visible)• Кухненски абсорбатор
• Засмукваща мощност: 326.4 m³/h
natural_image
Technical line drawing of a mechanical component mounted on a brick wall (no text or symbols)Метод Б
natural_image
Technical line drawing of a mechanical device with two circular components and a central housing (no text or symbols)A

natural_image
Technical line drawing of a rectangular electronic component with internal circular feature and mounting holes (no text or symbols)C
PIC5

natural_image
Technical line drawing of a mechanical device with two circular components and a central hub (no text or symbols)B

natural_image
Simple line drawing of a rectangular device with a circular top and three arrows pointing inward (no text or symbols)D
V. РАБОТА
VI. ПОДДРЬЖКА
natural_image
Technical line drawing of a mechanical or electronic component with internal compartments and directional arrows indicating movement (no text or symbols)natural_image
Technical line drawing of a mechanical assembly with internal components and a magnified inset showing rotational motion (no text or symbols)Copyright © 2013 Network One Distribution. All rights reserved.
http://www.heinner.com, http://www.nod.ro
CE
Marcel Iancu Street, 3-5, Bucharest, Romania
Tel: +40 21 211 18 56, www.heinner.com, www.nod.ro
HEINNER
HAGYOMÁNYOS GÓZELSZÍVÓ
Modell: CH-400/ CH-400-BRW/
CH-400-BK/ XCH-450S

natural_image
Exterior view of a white air conditioner unit with ventilation grille and control panel (no visible text or symbols)
natural_image
Black overhead air purifier with ventilation slots and control panel (no text or symbols visible)
natural_image
3D rendering of a brown portable air vent or fan device with ventilation slots and ventilation grilles (no text or symbols visible)natural_image
Simple line drawing of a ceiling-mounted device mounted on a brick wall, with no text or symbols present.B. lehetőség
natural_image
Technical line drawing of a rectangular electronic component with circular holes and mounting feet, labeled A (no text or symbols on the diagram itself)PIC4

natural_image
Simple line drawing of a rectangular box with two circular components and an arrow indicating direction (no text or symbols)
natural_image
Diagram showing airflow or ventilation between two brick walls, one with a pipe and arrow indicating direction (no text or symbols)Keringető üzemmód
natural_image
Technical line drawing of a mechanical device with two circular components and a central handle (no text or symbols)A

natural_image
Simple line drawing of a rectangular box with a circular hole and directional arrows, no text or symbols present.C
PIC5

natural_image
Technical line drawing of a mechanical device with two circular components and a central hub (no text or symbols)B

natural_image
Simple line drawing of a rectangular object with a circular hole and three vertical arrows indicating force or movement (no text or symbols)D
V. MÜKÖDTETÉS
natural_image
Line drawing of a mechanical or electronic component with internal compartments and directional arrows indicating motion (no text or symbols)natural_image
Technical line drawing of a mechanical assembly with internal components and a magnified inset showing rotational flow (no text or symbols)VII. MÜSZAKI ADATLAP
Copyright © 2013 Network One Distribution. All rights reserved.
http://www.heinner.com, http://www.nod.ro

natural_image
White air conditioner unit with ventilation grille and ventilation duct (no visible text or symbols)
natural_image
Black overhead air conditioner unit with ventilation slots and indicator lights (no text or symbols visible)
natural_image
Brown portable air conditioner unit with ventilation slots and ventilation duct (no text or symbols visible)natural_image
Diagram of a metal grate device mounted on a brick wall, with two circular components and a base plate (no text or symbols)Metoda B
natural_image
Technical line drawing of a rectangular electronic component with mounting holes and a circular feature (no text or symbols)A
PIC4

natural_image
Simple line drawing of a rectangular box with two circular objects on its side, no text or symbols present.B

natural_image
Diagram showing airflow or ventilation between two building walls, one with pipe and arrow indicating direction (no text or symbols)natural_image
Technical line drawing of a mechanical assembly with two circular components and a central valve (no text or symbols)A

natural_image
Simple line drawing of a rectangular box with a circular opening and two arrows pointing inward (no text or symbols)C
PIC5

natural_image
Technical line drawing of a mechanical device with two circular components and a central hub (no text or symbols)B

natural_image
Simple line drawing of a rectangular object with a circular hole and three vertical arrows pointing downward (no text or symbols)D
V. UŻYCIE
VI. CZYSZCZENIE I KONSERWACJA
natural_image
Technical line drawing of a mechanical or architectural component with internal compartments and directional arrows indicating flow or movement (no text or symbols)natural_image
Technical line drawing of a mechanical assembly with internal components and a magnified inset showing internal flow or movement (no text or symbols)VII. SPECYFIKACJA TECHNICZNA
Copyright © 2013 Network One Distribution. All rights reserved.
http://www.heinner.com, http://www.nod.ro