ULTIMATE SPEED UOP 12 B1 - Pump

UOP 12 B1 - Pump ULTIMATE SPEED - Free user manual and instructions

Find the device manual for free UOP 12 B1 ULTIMATE SPEED in PDF.

📄 58 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice ULTIMATE SPEED UOP 12 B1 - page 4
View the manual : Français FR Dansk DA Deutsch DE English EN Nederlands NL
Pick your language and provide your email: we'll send you a specifically translated version.
Product type 12V Oil pump
Brand Ultimate Speed
Model UOP 12 B1
Input voltage 12 V DC
Power consumption 60 W
Max. operating duration 30 continuous minutes
Max. oil temperature 60 °C
Flow rate (diesel) approx. 1,5 l/min
Flow rate (engine oil at 60°C) approx. 0,2 l/min
Max. delivery head 0,7 m
Max. pressure 0,3 MPa / 3 bar
Protection class III
Protection rating IPX4
Weight (including accessories) approx. 890 g
Sound pressure level approx. 70 dB(A)
Included accessories Suction hose (ø 6 mm), discharge hose (ø 12 mm), 2 hose clamps
Intended use Pumping engine oil or diesel for private use
Warranty 3 years
Customer service France Tel. 0800 919270, Email: grizzly@lidl.fr
Safety symbols Caution, wear eye protection, gloves, respiratory protection, pumping direction, class III, do not dispose of with household waste

Frequently Asked Questions - UOP 12 B1 ULTIMATE SPEED

What oil can be pumped with the UOP 12 B1 pump?
The pump is intended for pumping engine oil and diesel for private use. Do not pump gearbox oil, water, flammable liquids like gasoline, or food, chemicals, acids, alkalis, varnishes or paints.
How long can I use the pump continuously?
The maximum continuous operating time is 30 minutes. After that, let the pump cool down for at least 10 minutes before using it again to avoid overheating.
How to connect the pump to the vehicle battery?
Make sure the device is switched off (switch to 0). Connect the red terminal (+) to the positive pole of the battery and the black terminal (-) to the negative pole. Only connect to a 12 V battery.
What to do if the pump does not deliver oil?
Check that the hoses are not kinked or blocked. Make sure the suction hose is immersed in the oil and the pump is properly connected. If the problem persists, the oil may be too viscous: warm up the engine for a few minutes (oil max. 60°C).
How to clean the pump after use?
After each use, pump new oil to rinse the device. Clean the contact terminals with a dry cloth. Wipe the housing and hoses with a soft cloth, without aggressive solvents. Never clean under running water.
Can I pump gasoline or flammable liquids?
No, this is strictly forbidden. The pump is not designed for flammable liquids such as gasoline, kerosene or solvents. Pumping such liquids poses a fire and explosion hazard.
What is the maximum temperature for the pumped oil?
The oil temperature must not exceed 60 °C. Oil that is too hot can cause burns and damage the pump. Warm up the engine for 5 to 10 minutes before pumping, but do not pump hot oil.
How to store the pump?
Store the pump in a dry place, frost-free and out of reach of children. Store used oil in suitable, leak-proof containers.
What is the warranty on this product?
This product comes with a 3-year warranty from the date of purchase. For any claims, keep the receipt and contact customer service (0800 919270 or grizzly@lidl.fr).
Where can I find spare parts?
Spare parts (hoses, hose clamps) are available at www.grizzly-service.eu or by contacting customer service. References: suction hose (30230131), discharge hose (30230132), clamps (30230130).

User questions about UOP 12 B1 ULTIMATE SPEED

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Pump in PDF format for free! Find your manual UOP 12 B1 - ULTIMATE SPEED and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UOP 12 B1 by ULTIMATE SPEED.

USER MANUAL UOP 12 B1 ULTIMATE SPEED

OIL PUMP 12V UOP 12 B1

GB IE NI

OIL PUMP 12V

Translation of the original instructions

FR BE

POMPE À HUILE 12V

Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device.

DK

Areas of Application ....5

General Description......5

Scope of Delivery......5

Overview....5

Technical Data......5

Notes on Safety 6

Symbols on the device....6

Symbols in the manual....6

General notes on safety 6

Operational start-up ......9

Fitting the hoses 9

Operation....9

Cleaning/Maintenance......10

General cleaning instructions......10

General maintenance instructions.....10

Storage....10

Waste Disposal/Environmental

Protection ....10

Replacement parts/Accessories ..11

Guarantee 11

Repair Service....12

Service-Center......12

Importer 12

Translation of the original

EC declaration of conformity .....53

Introduction

Congratulations on the purchase of your new device. With it, you have chosen a high quality product.

During production, this equipment has been checked for quality and subjected to a final inspection. The functionality of your equipment is therefore guaranteed. It cannot be ruled out that residual quantities of water or lubricants will remain on or in the equipment/hose lines in isolated cases. This is not a fault or defect and it represents no cause for concern.

ULTIMATE SPEED UOP 12 B1 - Introduction - 1

The operating instructions constitute part of this product. They contain important information on safety, use and disposal.

Before using the product, familiarise yourself with all of the operating and safety instructions. Use the product only as described and for the applications specified.

Keep this manual safely and in the event that the product is passed on, hand over all documents to the third party.

Areas of Application

The oil pump is intended for pumping out engine oil or diesel for private use. It is not intended for commercial use.

The appliance is not suitable for pumping out transmission oil, water or flammable liquids such as gasoline and petroleum.

Sucking up food, chemicals, acids, alkalis, paints and varnishes is prohibited.

The appliance may be used a maximum of 30 minutes at a time; it is not designed for continuous operation.

Any other use that is not expressly permitted in these instructions may result in damage to the appliance and pose a serious hazard to the user.

The operator or user is responsible for accidents or damage to other people or their property. The manufacturer shall not be liable for damages caused by use other than for which the equipment is intended or by incorrect operation.

General Description

ULTIMATE SPEED UOP 12 B1 - General Description - 1

The illustration of the principal functioning parts can be found on the foldout page.

Scope of Delivery

Carefully unpack the appliance and check that it is complete. Dispose of the packaging material correctly.

  • Oil pump with a battery connection cable
  • Suction hose
  • Drain hose
  • 2 hose clamps
  • Instructional manual

Overview

Appliance

1 On/off switch
2 Pump housing
3 Battery connection cable
4 Positive pole terminal (+) (red)
5 Negative pole terminal (-) (black)
6 Drain hose connection (OUT)
7 Protective caps
8 Suction pipe connection (IN)

Accessories

9 Suction hose (ø 6 mm)
10 Hose clamps
11 Drain hose (ø 12 mm)

Technical Data

Oil pump......UOP 12 B1

Input voltage U 12 V =

Power input P 60 W

Max. running time t_max .....30 min

Max. temperature _ 60 °C

Safety class .... III

Protection category ......IPX4

Output (pump capacity)*

diesel .... approx. 1.5 l/min engine oil (60 °C) .... approx. 0.2 l/min Max. discharge head .... 0.7 m

Max. permissible pressure .. 0.3 MPa / 3 bar Weight (incl. accessories).....approx. 890 g Sound pressure level .....approx. 70 dB(A)

* The capacity may vary depending on the type and temperature of the drained oils.

Technical and optical changes can be carried out in the course of further development without notice. All dimensions, references and information of this instruction manual are therefore without guarantee.

Legal claims, which are made on the basis of the instruction manual, cannot thus be considered as valid.

GBIENI

Notes on Safety

This section describes the basic safety rules when working with the device.

Symbols on the device

ULTIMATE SPEED UOP 12 B1 - Symbols on the device - 1

Caution!

ULTIMATE SPEED UOP 12 B1 - Symbols on the device - 2

Read and follow the operating instructions provided for the device.

ULTIMATE SPEED UOP 12 B1 - Symbols on the device - 3

Wear eye protection.

ULTIMATE SPEED UOP 12 B1 - Symbols on the device - 4

Wear hand protection.

ULTIMATE SPEED UOP 12 B1 - Symbols on the device - 5

Wear breathing protection.

Pumping direction

ULTIMATE SPEED UOP 12 B1 - Symbols on the device - 6

Safety class III

ULTIMATE SPEED UOP 12 B1 - Symbols on the device - 7

Electric appliances should not be disposed of in the domestic garbage.

Symbols in the manual

ULTIMATE SPEED UOP 12 B1 - Symbols in the manual - 1

Warning symbols (the danger can be explained at the place of the exclamation mark) with information on damage and injury prevention.

ULTIMATE SPEED UOP 12 B1 - Symbols in the manual - 2

Instruction symbols (the instruction can be explained at the place of the exclamation mark) with information on preventing damage.

ULTIMATE SPEED UOP 12 B1 - Symbols in the manual - 3

Help symbols with information on improving tool handling.

General notes on safety

- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children must not play with the device.

- Ensure that there are no children or pets are in the vicinity of the working area.

• People who are not familiar with the operating instructions may not use the appliance. Local regulations may specify the

- minimum age of the operator. - Check the appliance, battery cables and terminals for damage before each use. Use only original accessories. Do not work with a damaged or incomplete appliance or one which has been converted without the permission of the manufacturer. Ensure that damage to your appliance is made good by a specialist or by customer service (see "Service Center"). This ensures the safety of the appliance is maintained.

- Make sure before use that the appliance is properly assembled. Always fasten the hoses with hose clamps to prevent the release of the hoses and oil spills.

- The appliance may only be powered with SELV (Safety Extra Low Voltage) as indicated by the label on the appliance.

- Keep the appliance away from rainy or wet conditions. Penetration of water into the electrical appliance increases the risk of electric shock.

- Pay attention as well to the operating instructions of your vehicle manufacturer regarding the pumping of oil.

- Wear personal protective equipment such as work clothes, breathing protection, goggles and gloves. We recommend the use of acid

and alkali-resistant protective gloves. The wearing of personal protective equipment reduces the risk of injury.

- Be attentive and use common sense when working with this appliance. Never leave the appliance unattended during the pumping operation. A moment of inattention while operating the appliance may result in injury.

- Fuels and lubricants can damage health. Avoid direct skin contact and inhalation of fumes. Rinse wetted skin areas with soap and water and consult a doctor if necessary.

- Be especially careful when working on a vehicle battery. Battery acid may leak and cause serious injury. Rinse the affected skin or eyes with water and consult a doctor if necessary.

- Do not park your vehicle on an inclined surface, as a complete drainage is not possible then.

- Grasp the terminals only by the insulated handles. Connect the positive pole terminal to the positive pole of the vehicle battery and the negative terminal to the negative pole (see "Operational start-up"). The possibility of an electrical short circuit is thereby avoided.

- The connection cable of this appliance cannot be replaced. If the cable is damaged, the

GBIENI

appliance must be scrapped.

- Do not pump when the engine is switched on or hot. Do not start the vehicle engine during the pumping process. There is a risk of burning.

- Never pump for longer than 30 minutes in continuous operation in order to prevent overheating and damage to the appliance.

- Do not pump oil at a temperature over 60°C. There is a risk of burning and appliance damage.

- Do not use the appliance near flammable liquids or gases. Do not smoke during the drainage process. Make sure there is good ventilation in the work area. There is a risk of fire or explosion if this advice is not heeded.

- Do not pump flammable materials or gasoline. There is a risk of fire or explosion if this advice is not heeded.

- Do not run the appliance dry. Do not pump water or aqueous solutions. The appliance can become damaged as a result of insufficient lubrication.

- Collect the pumped off oil only in designated containers. Do not pump different oils into the same container.

- Disconnect from the vehicle battery terminals after the pumping process.

- Do not carry the appliance by means of the battery connection cable or the hoses and keep the connection cable and hoses away from hot vehicle parts or sharp edges. The appliance could be damaged.

- Keep the appliance and the used oil in a dry place and out of reach of children.

- Dispose of used oil and soaked rags properly (see "Waste Disposal/Environmental Protection"). In order to protect the environment, do not let oils or diesel drain into the ground or empty them into drains.

- Please read about the guidance relating to the topics "Cleaning/Maintenance" and "Storage" in the operating instructions. All other measures, and opening the appliance in particular, must be carried out by a qualified electrician. Always contact our service centre in the case of repairs. Many accidents are caused by poorly maintained appliances.

ULTIMATE SPEED UOP 12 B1 - GBIENI - 1

Operational start-up

Fitting the hoses

  1. Remove the protective caps (7).

  2. Unroll the suction hose (9) and the drain hose (11) and bend them straight.

  3. Push the suction hose (ø 6 mm) (9) onto the suction hose connection (8).

ULTIMATE SPEED UOP 12 B1 - Fitting the hoses - 1

  1. Slide the drain hose (ø 12 mm) (11) onto the drain hose connection (6).

ULTIMATE SPEED UOP 12 B1 - Fitting the hoses - 2

  1. Attach both hoses (9, 11) with the supplied hose clamps (10).

ULTIMATE SPEED UOP 12 B1 - Fitting the hoses - 3

Note the pumping direction → → of the appliance.

ULTIMATE SPEED UOP 12 B1 - Fitting the hoses - 4

Ensure that the hoses (9, 11) are not bent or kinked to avoid damage.

Operation

ULTIMATE SPEED UOP 12 B1 - Operation - 1

Let the vehicle engine run for 5-10 minutes before pumping in order to warm up (oil temperature max. 60 °C). This reduces the viscosity of the oil and it can pump out better.

ULTIMATE SPEED UOP 12 B1 - Operation - 2

Turn off the car engine before you start pumping.

  1. In the case of vehicles, feed the suction hose (ø 6 mm) (9) through the oil level test aperture. Gently slide the hose to the lowest point of the oil pan.

  2. Insert the drain hose (ø 12 mm) (11) into a suitable container (e.g. oil collecting tray) to collect the used oil.

  3. Make sure that the appliance is switched off (on/off switch (1) in position "○").

  4. Connect the positive pole terminal (red) (4) to the positive pole (+) of the vehicle battery.

  5. Connect the negative pole terminal (black) (5) to the negative pole (-) of the vehicle battery.

  6. Switching on:

On/off switch (1) in position "I".

After a suction period the pump begins to extract.

  1. Switching off:

On/off switch (1) in position "O".

Turn the power off

- as soon as the oil ceases to be extracted, - or after a continuous running time of 30 minutes.

  1. Clean the appliance after each use by pumping through some fresh oil.

  2. Remove the terminals (4, 5) from the vehicle battery.

ULTIMATE SPEED UOP 12 B1 - Operation - 3

Never pump for longer than 30 minutes in continuous operation in order to prevent overheating and damage to the appliance. Turn off the appliance and allow it to cool for at least 10 minutes between the run cycles.

ULTIMATE SPEED UOP 12 B1 - Operation - 4

Change the oil filter and replenish with fresh oil according to the instructions of your vehicle manufacturer.

ULTIMATE SPEED UOP 12 B1 - Operation - 5

Dispose of used oil in an environmentally-responsible way (see "Waste Disposal/Environmental Protection").

Cleaning/Maintenance

Clean and maintain your equipment regularly. This will guarantee its performance and long durability.

ULTIMATE SPEED UOP 12 B1 - Cleaning/Maintenance - 1

Ask our service centre to carry out any work that is not described in these instructions. Use only original parts. There is a risk of injury!

ULTIMATE SPEED UOP 12 B1 - Cleaning/Maintenance - 2

Do not clean the appliance under running water. There is a risk of electric shock and the appliance could be damaged.

General cleaning instructions

  • Clean the appliance after each use by pumping through some fresh oil.
  • Clean the terminals ( A 4, 5) after the operation. Wipe away any adhering battery fluid with a dry cloth.
  • Keep the pump housing (A 2) and the hoses (A 9, 11) clean. Use a cloth for this but no aggressive cleaning agents or solvents.
  • Mop up spilled oil with a soft cloth or paper towel.

General maintenance instructions

  • Check appliance, hoses (9A11), battery connection cable (A3) and terminals (A4, 5) for visible damage.
  • Check before each use that the hose clamps (A 10) are tight.

Storage

  • Store the appliance cleaned in a dry, frost-free place, and where children cannot gain access to it.
  • Store used oil and diesel in suitable and approved containers.

Waste Disposal/Environmental Protection

ULTIMATE SPEED UOP 12 B1 - Waste Disposal/Environmental Protection - 1

Electrical appliances and waste oils do not belong in household waste.

  • The appliance, accessories and packaging should be properly recycled.
  • Dispose of your appliance at a recycling point. The plastic and metal parts used on your appliance can be properly sorted according to materials and grades and efficiently recycled.
  • Dispose of used oil at a disposal site and do not pour onto the ground, into sewers or down the drain.
  • Please contact our service centre for more information.
  • Defective units returned to us will be disposed of for free.

Replacement parts/Accessories

Spare parts and accessories can be obtained at www.grizzly-service.eu

If you do not have internet access, please contact the Service Centre via telephone (see "Service-Center" page 12). Please have the order number mentioned below ready.

B 9 Suction hose ( 6 mm) 30230131

B 10 Hose clamps (2 pieces) 30230130

B 11 Drain hose (ø 12 mm) 30230132

Guarantee

Dear Customer,

This equipment is provided with a 3-year guarantee from the date of purchase. In case of defects, you have statutory rights against the seller of the product. These statutory rights are not restricted by our guarantee presented below.

Terms of Guarantee

The term of the guarantee begins on the date of purchase. Please retain the original receipt. This document is required as proof of purchase.

If a material or manufacturing defect occurs within three years of the date of purchase of this product, we will repair or replace – at our choice – the product for you free of charge. This guarantee requires the defective equipment and proof of purchase to be presented within the three-year period with a brief written description of what constitutes the defect and when it occurred.

If the defect is covered by our guarantee, you will receive either the repaired product or a new product. No new guarantee period begins on repair or replacement of the product.

Guarantee Period and Statutory Claims for Defects

The guarantee period is not extended by the guarantee service. This also applies for replaced or repaired parts. Any damages and defects already present at the time of purchase must be reported immediately after unpacking. Repairs arising after expiry of the guarantee period are chargeable.

Guarantee Cover

The equipment has been carefully produced in accordance with strict quality guidelines and conscientiously checked prior to delivery.

The guarantee applies for all material and manufacturing defects. This guarantee does not extend to cover product parts that are subject to normal wear and may therefore be considered as wearing parts (e.g. hoses) or to cover damage to breakable parts (e.g. switches).

This guarantee shall be invalid if the product has been damaged, used incorrectly or not maintained. Precise adherence to all of the instructions specified in the operating manual is required for proper use of the product. Intended uses and actions against

GBIENI

which the operating manual advises or warns must be categorically avoided. The product is designed only for private and not commercial use. The guarantee will be invalidated in case of misuse or improper handling, use of force, or interventions not undertaken by our authorised service branch.

Processing in Case of Guarantee

To ensure quick handling of you issue, please follow the following directions:

  • Please have the receipt and identification number (IAN 279419) ready as proof of purchase for all enquiries.
  • Please find the item number on the rating plate.
  • Should functional errors or other defects occur, please initially contact the service department specified below by telephone or by e-mail. You will then receive further information on the processing of your complaint.
  • After consultation with our customer service, a product recorded as defective can be sent postage paid to the service address communicated to you, with the proof of purchase (receipt) and specification of what constitutes the defect and when it occurred. In order to avoid acceptance problems and additional costs, please be sure to use only the address communicated to you. Ensure that the consignment is not sent carriage forward or by bulky goods, express or other special freight. Please send the equipment inc. all accessories supplied at the time of purchase and ensure adequate, safe transport packaging.

Repair Service

For a charge, repairs not covered by the guarantee can be carried out by our service branch, which will be happy to issue a cost estimate for you.

We can handle only equipment that has been sent with adequate packaging and postage.

Attention: Please send your equipment to our service branch in clean condition and with an indication of the defect.

Equipment sent carriage forward or by bulky goods, express or other special freight will not be accepted.

We will dispose of your defective devices free of charge when you send them to us.

Service-Center

GB Service Great Britain Tel.: 0871 5000 720 (£ 0.10/Min.) E-Mail: grizzly@lidl.co.uk IAN 279419

IE Service Ireland Service Northern Ireland NI Tel.: 1890 930 034 (0,08 EUR/Min., (peak)) (0,06 EUR/Min., (off peak)) E-Mail: grizzly@lidl.ie IAN 279419

Importer

Please note that the following address is not a service address. Please initially contact the service centre specified above.

Service-Center......21

Importør 21

Service Réparations ......32

Service-Center......32

Importeur 32

Service-Center......42

Importeur 42

Service-Center....51

Importeur ....51

ULTIMATE SPEED UOP 12 B1 - Importer - 1Translation of the original EC declaration of conformity
We hereby confirm that the Oil pump 12V model UOP 12 B1 Serial number 201611000001 - 201611265624 conforms with the following applicable relevant version of the EU guidelines:
2014/30/EU • 2006/42/EC • 2011/65/EU*
In order to guarantee consistency, the following harmonised standards as well as national standards and stipulations have been applied:
EN 60335-1:2012/A11:2014 • EN 60335-2-41:2003/A2:2010 • EN 62233:2008 EN 50498:2010 • EN 62321-1:2013
This declaration of conformity is issued under the sole responsibility of the manufacturer:
Grizzly Tools GmbH & Co. KG Stockstädter Straße 20 63762 Großostheim, GERMANY 08.12.2016 ULTIMATE SPEED UOP 12 B1 - Importer - 2ULTIMATE SPEED UOP 12 B1 - Importer - 3

Translation of the original EC declaration of conformity

* The object of the declaration described above satisfies the provisions of Directive 2011/65/EU of the European Parliament and the Council of 8 June 2011 on limiting the use of certain harmful substances in electrical and electronic appliances.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ULTIMATE SPEED

Model : UOP 12 B1

Category : Pump