EINHELL GC-GP 1170 Eco Plus - Pump

GC-GP 1170 Eco Plus - Pump EINHELL - Free user manual and instructions

Find the device manual for free GC-GP 1170 Eco Plus EINHELL in PDF.

📄 152 pages English EN Download 💬 AI Question
Notice EINHELL GC-GP 1170 Eco Plus - page 12
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about GC-GP 1170 Eco Plus EINHELL

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Pump in PDF format for free! Find your manual GC-GP 1170 Eco Plus - EINHELL and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GC-GP 1170 Eco Plus by EINHELL.

USER MANUAL GC-GP 1170 Eco Plus EINHELL

GB Original operating instructions Garden pump

natural_image Close-up of a black threaded pipe fitting with a labeled dimension '8' (no text or symbols beyond the number)

EINHELL GC-GP 1170 Eco Plus - 1

natural_image Simple line drawing of an open book with no text or symbols on the pages

-3-

EINHELL GC-GP 1170 Eco Plus - 2

EINHELL GC-GP 1170 Eco Plus - 3

D

Gefahr!

When using the equipment, a few safety precautions must be observed to avoid injuries and damage. Please read the complete operating instructions and safety regulations with due care. Keep this manual in a safe place, so that the information is available at all times. If you give the equipment to any other person, hand over these operating instructions and safety regulations as well. We cannot accept any liability for damage or accidents which arise due to a failure to follow these instructions and the safety instructions.

Explanation of the symbols used (see Fig. 3)

  1. Danger! - Read the operating instructions to reduce the risk of injury.

1. Safety regulations

Danger!

Read all safety regulations and instructions. Any errors made in following the safety regulations and instructions may result in an electric shock, fi re and/or serious injury.

Keep all safety regulations and instructions in a safe place for future use.

Danger!

In stagnant water bodies, garden ponds, swimming ponds and their surrounding areas the unit may only be used with an earth-leakage circuit breaker with an actuating rated current of up to 30 mA (according to VDE 0100 Part 702 and 738).

The equipment is not designed for use in swimming pools and paddling pools of any kind or other bodies of water in which people or animals may be present during operation. It is prohibited to operate the equipment if a person or animal is in the danger area. Ask your electrician!

Danger!

  • Always inspect the equipment visually before using it. Do not use the equipment if safety devices are damaged or worn. Never disable safety devices.
    • Use the equipment only for the purposes indicated in these operating instructions.
  • You are responsible for safety in the work area.
  • If the cable or plug is damaged by external influences, the cable may not be repaired. The

cable must be replaced by a new one. This work may only be carried out by a trained electrician.

  • The voltage of 220-240 V alternating voltage specified on the rating plate must be the same as the mains voltage.
  • Never use the power cable to lift, transport or secure the equipment.
  • Ensure that the electrical plug connections are in areas that are not at risk of flooding or protect them from moisture.
  • Pull the mains plug before starting any work on the equipment.
  • Do not expose the equipment to a direct jet of water.
  • The operator is responsible for complying with local safety and installation regulations. (Ask an electrician if you are in any doubt.)
  • Consequential damage caused by flooded rooms in the event of the equipment suffering faults must be prevented by the user by means of suitable measures (for example installing alarm systems or a reserve pump, etc.).
  • In the event of a failure, repair work may only be carried out by an electrician or by after sales service personnel.
  • The equipment must never run dry or be used when the intake line is closed fully. The manufacturer's warranty does not cover damage caused to the equipment as a result of running it dry.
  • The pump must not be used to operate swimming pools.
  • The equipment must not be installed in the drinking water pipe line.

This equipment can be used by children of 8 years and older and by people with limited physical, sensory or mental capacities or those with no experience and knowledge if they are supervised or have received instruction in how to use the equipment safely and understand the dangers which result from such use. Children are not allowed to play with the equipment. Unless su-

GB

pervised, children are not allowed to clean the equipment and carry out user-level maintenance work.

2. Layout and items supplied

2.1 Layout

  1. Filling level indicator
  2. Suction connection
  3. Water filler screw
  4. Pressure connection
  5. Carry handle
  6. Power switch
  7. Water drain screw
  8. Connection adapter approx. 33.3 mm (R1 male thread)

2.2 Items supplied

Please check that the article is complete as specified in the scope of delivery. If parts are missing, please contact our service center or the sales outlet where you made your purchase at the latest within 5 working days after purchasing the product and upon presentation of a valid bill of purchase. Also, refer to the warranty table in the service information at the end of the operating instructions.

  • Open the packaging and take out the equipment with care.
  • Remove the packaging material and any packaging and/or transportation braces (if available).
  • Check to see if all items are supplied.
  • Inspect the equipment and accessories for transport damage.
  • If possible, please keep the packaging until the end of the guarantee period.

Danger!

The equipment and packaging material are not toys. Do not let children play with plastic bags, foils or small parts. There is a danger of swallowing or suff ocating!

  • Garden pump
    • Connection adapter approx. 33.3 mm (R1 male thread)
    • Original operating instructions

3. Proper use

Applications:

  • Irrigation and watering of green areas, vegetable beds and gardens.
    • Operation of lawn sprinklers.
  • Drawing of water (with pre-filter) from ponds, streams, rain barrels, rainwater cisterns and wells.
    • For supplying service water

Transport media:

  • For the pumping of clear water (fresh water), rainwater or light suds/service water.
  • The maximum temperature of the fluid must not exceed +35°C if the equipment is operated permanently.
  • Do not use the equipment to pump inflammable, gassing or explosive fluids.
  • The pumping of aggressive liquids (acids, alkalis, silo seepage etc.) as well as liquids with abrasive substances (sand) must likewise be avoided.
  • This equipment is not designed to pump drinking water.

The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user / operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.

Please note that our equipment has not been designed for use in commercial, trade or industrial applications. Our warranty will be voided if the machine is used in commercial, trade or industrial businesses or for equivalent purposes.

4. Technical data

Mains connection .....220-240 V \~ 50 Hz
Power consumption 1100 W
Max. pumping rate 7000 l/h
Delivery head max. 50 m
Delivery pressure max. 0.50 MPa (5.0 bar)
Suction height max. 8 m
Pressure connection ..... approx. 33.3 mm (R1IG)
Suction connection ... approx. 42 mm (R1 ¼ AG)
Water temperature max. 35°C
Sound power level 80.98 dB (A)
Uncertainty 1.66 dB

GB

Protection type IPX4

5. Before starting the equipment

Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.

Warning!

Always pull the power plug before making adjustments to the equipment.

As a basic principle, we recommend the use of a preliminary filter and a suction set with suction hose, suction strainer and non-return valve, in order to prevent long priming periods and unnecessary damage to the pump as a result of stones and solid foreign bodies.

5.1 Connecting the intake line

  • Fasten the suction hose (at least approx. 19 mm ( 3/4" ) plastic hose with spiral reinforcement) to the suction connection (approx. 42 mm / R1 14 male thread) of the equipment either directly or via a threaded nipple.
  • Use the connection adapter (8) to reduce the thread of the suction connection to approx. 33.3 mm (R1 male thread).
  • The suction hose used should be equipped with an intake valve. If the intake valve cannot be used, a non-return valve should be installed in the intake line.
  • Position the intake line so that it rises from the water withdrawal point to the equipment. Avoid positioning the suction pipe higher than the pump, as this would delay the escape of air bubbles from the suction pipe and impede the priming process.
    • Install the intake and discharge lines in such a way that they do not exert any mechanical pressure on the equipment.
  • The intake valve should be low enough in the water to ensure that if the water level falls, the equipment will not run dry.
    • A leaking intake line will draw in air and therefore not draw in any water.
  • Prevent the intake of foreign bodies (sand etc.). If necessary, install a coarse filter for this purpose.

5.2 Connecting the discharge line

- The discharge line approx. 19 mm (3/4") must be connected to the approx. 33,3 (R 1IG) discharge line connector of the equipment either directly or with the aid of a threaded

nipple.

  • With the right couplings it is also possible, of course, to use a approx. 13 mm (½ " ) delivery hose. The smaller delivery hose results in a lower delivery rate.
  • During the priming operation, fully open any shut-off mechanisms (spray nozzles, valves, etc.) in the pressure line so that the air can escape without obstruction.

5.3 Electrical connections

  • Connect the appliance to a 220-240 V \~ 50 Hz socket-outlet with earthing contact. Minimum fuse 10 ampere.
  • A built-in thermostat protects the motor from overloading and blocking. The pump is switched off automatically by the thermostat if overheating occurs and is switched on again automatically after cooling.

6. Operation

• Install the equipment on a solid and level surface.
- Fill the pump housing with water via the water filler screw (3). Filling the intake line accelerates the intake process.
- All the shut-off devices in the discharge line (spray nozzle, valves etc.) must be fully opened during intake in order to permit all air to escape from the intake line.
- Connect the power cable.
- The intake process starts automatically once you press the ON/OFF switch (6). – The intake process can take up to 5 minutes for the maximum suction height.
- If the pump is removed after use, it is essential that it is filled with water again the next time it is connected and started.

After use, switch the pump back off again by pressing the ON/OFF switch again (6) and allow the pump to cool down. Then disconnect the power plug.

7. Replacing the power cable

Danger!

If the power cable for this equipment is damaged, it must be replaced by the manufacturer or its after-sales service or similarly trained personnel to avoid danger.

GB

8. Cleaning, maintenance and ordering of spare parts

The equipment is almost completely maintenance free. In order to ensure a long service life, however, we recommend that you regularly check and care for the product.

Danger!

The equipment must be disconnected from the power supply (pull the power plug) prior to performing any maintenance.

8.1 Servicing

  • If the equipment becomes clogged, connect the discharge line to the water line and disconnect the suction hose. Open the water line. Switch on the equipment several times for approx. two seconds. This should resolve the majority of clog-related problems.
  • There are no parts inside the equipment which require additional maintenance.

8.2 Ordering replacement parts:

Please quote the following data when ordering replacement parts:

• Type of machine
• Article number of the machine
• Identification number of the machine
- Replacement part number of the part required For our latest prices and information please go to www.Einhell-Service.com

9. Disposal and recycling

The equipment is supplied in packaging to prevent it from being damaged in transit. The raw materials in this packaging can be reused or recycled. The equipment and its accessories are made of various types of material, such as metal and plastic. Never place defective equipment in your household refuse. The equipment should be taken to a suitable collection center for proper disposal. If you do not know the whereabouts of such a collection point, you should ask in your local council offices.

10. Storage

  • Store the equipment and its accessories in a dark and dry place above freezing temperature. The ideal storage temperature is between 5 and 30°C. Store the equipment in its original packaging.
  • If the pump is not going to be used for a long time or has to be removed for the winter months, rinse it out with water, empty it completely and allow it to dry.
  • The equipment must be completely drained before it is subjected to frost.
    • After long stoppages, make sure the rotor turns correctly by briefly switching the pump on and off.

11. Troubleshooting guide

Faults CauseRemedy
Motor fails to start up- No mains voltage- Pump rotor blocked -thermostat switched off- Check voltage- Dismantle and clean pump
No intake - Intake valve- Immerse intake valve in water- Fill water into intake- Air in intake line air-tight- Intake valve leaks- Strainer (intake valve) blocked- Max. suction height exceeded- Make sure intake line is close- Clean intake valve- Clean strainer- Check suction height
Inadequate delivery rate- Suction height too high- Strainer dirty- Water level falling rapidly- Pump performance diminished by contaminants part- Check suction height- Clean strainer- Immerse intake valve deeper- Clean pump and replace wearing
Thermostat switches pump off- Motor overloaded - friction caused by foreign substances too high- Dismantle and clean pump. Prevent intake of foreign substances (fi liter)

GB

Disposal

EINHELL GC-GP 1170 Eco Plus - Disposal - 1

Power tools, rechargeable batteries, accessories and packaging should be sorted for environmental-friendly recycling.

Do not dispose of power tools and batteries/rechargeable batteries into household waste!

Only for EU countries:

According to the Directive 2012/19/EU on waste electrical and electronic equipment and its transposition into national law, power tools that are no longer usable, and, according to the Directive 2006/66/EC, defective or drained batteries must be collected separately and disposed of in an environmentally correct manner.

If disposed incorrectly, waste electrical and electronic equipment may have harmful effects on the environment and human health, due to the potential presence of hazardous substances.

Only for United Kingdom:

According to The Waste Electrical and Electronic Equipment Regulations 2013 (SI 2013/3113) (as amended) and the Waste Batteries and Accumulators Regulations 2009 (SI 2009/890) (as amended), products that are no longer usable must be collected separately and disposed of in an environmentally friendly manner.

The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of the Einhell Germany AG.

Subject to technical changes

GB

Service information

We have competent service partners in all countries named on the guarantee certificate whose contact details can also be found on the guarantee certificate. These partners will help you with all service requests such as repairs, spare and wearing part orders or the purchase of consumables.

Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also required for use as consumables.

Category Example
Wear parts*Coarse filter, filter cartridge
Consumables*
Missing parts

* Not necessarily included in the scope of delivery!

In the effect of defects or faults, please register the problem on the internet at www.Einhell-Service.com. Please ensure that you provide a precise description of the problem and answer the following questions in all cases:

• Did the equipment work at all or was it defective from the beginning?
• Did you notice anything (symptom or defect) prior to the failure?
• What malfunction does the equipment have in your opinion (main symptom)?
Describe this malfunction.

F

Danger!

Pumpetryk maks. 0,50 MPa (5,0 bar)

X 2006/42/EC
Annex IV
Notified Body:
Reg. No.:

X 2000/14/EC_2005/88/EC

X Annex V

□ Annex VI

Noise: measured L_WA = 80,98 dB (A); guaranteed L_WA = 83 dB (A)

P = kW; L/∅ = cm

Notified Body:

2012/46/EU_(EU)2016/1628 Emission No.:

Standard references: EN 60335-1; EN IEC 60335-2-41; EN 62233; EN IEC 55014-1; EN IEC 55014-2; EN IEC 61000-3-2; EN 61000-3-3

Subject to change without notice

Archive-File/Record: NAPR029984

Documents registrar: Helmut Bauer

Wiesenweg 22, D-94405 Landau/Isar

* GRI Garden pump - P Panpa de jardin - J Panpa por girdino - UKW Aumpampa - ST Bérdigerpump - CZ Bestoneka pumppa - SK Zárznańó čerpedlo - NL Timpomp - E Bomba da jardin - PN Puhratnapumpa - SLO Vltna čpakia - H Korti škynytá - RO Panpa do grádín - GR Armla knysu - P Bomba do jardín - NR/H9H Vltna pumppa - RS Bistloneka pumppa - PL Panpa ogrisnowa - TR Bárpo portpos - RUS Cedero-ogorodni valnočnýho nocs - EE Aéirpmp - LV Garza súltus - LT Sodo súltus - BG Gradinica nomska - UKM Cadranič oscos - MK Pyma za građina - NO Haperupmpa IS Girafvatinselki

EINHELL GC-GP 1170 Eco Plus - Standard references: EN 60335-1; EN IEC 60335-2-41; EN 62233; EN IEC 55014-1; EN IEC 55014-2; EN IEC 61000-3-2; EN 61000-3-3 - 1

Declaration of conformity

We, Einhell UK Ltd

Champions Business Park, First Floor Unit 10, Arrowe Brook Rd, Upton, Wirral CH49 0AB, United Kingdom

declare the conformity to UK standards and legislation was assessed for:

Garden Pump GC-GP 1170 ECO PLUS (Einhell)

UK legislation

□ Simple Pressure Vessels (Safety) Regulation
□ Electrical Equipment (Safety) Regulation
□ Radio Equipment Regulation
□ Personal Protective Equipment Regulation
☐ The Ecodesign for Energy-Related Products and Energy Information Regulation
X The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulation
X Noise Emission in the Environment by Equipment for use Outdoors Regulation
X Electromagnetic Compatibility Regulation
□ Measuring Instruments Regulation
☐ Pressure Equipment (Safety) Regulation

X Annex V

Annex VI

Noise:measuredL w = 80.98 dB (A); guaranteed L w = 83 dB (A)
P = kW; L/∅ = cm
UK Approved Body:

X Supply of Machinery (Safety) Regulation

Annex IV

UK Approved Body:

UKTE Certifi cate No.:

Standards: BS EN 60335-1; BS EN IEC 60335-2-41; BS EN 62233; BS EN IEC 55014-1; BS EN IEC 55014-2; BS EN IEC 61000-3-2; BS EN 61000-3-3

Wirral, 2024.07.25

EINHELL GC-GP 1170 Eco Plus - UK legislation - 1

Archive-File/Record: NAPR029984

Article Number: 41.802.20 I.-No.: 21014

Subject to change without notice Wiesenweg 22, 94405 Landau/Isar, Germany

Documents registrar: Helmut Bauer

EH 10/2024 (01)

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : EINHELL

Model : GC-GP 1170 Eco Plus

Category : Pump