Product TypeUltrasonic Humidifier
BrandLund
Model66906
Tank Capacity1000 ml
Steam Output Efficiency70 ml/h
Recommended Coverage Area50 m²
Weight0.5 kg
Input Voltage (Adapter)110-240 V~, 50-60 Hz
Output Voltage (Device)24 V DC
Rated Current (Device)650 mA
Output Current (Adapter)500 mA
Control TypeTouch screen with 3 buttons (On/Off, Intensity, Backlight)
FunctionsContinuous or timed emission (3H, etc.), steam intensity adjustment, multicolor LED backlight with automatic color change
Water SupplyCold water only, temperature ≤ 35 °C
Use of FragrancesUltrasonic fragrances only, mix with water before filling
MaintenanceClean every 3 days with citric acid and hot water (70 °C) to descale
SafetyDo not immerse, avoid excessive humidity, unplug before cleaning, do not obstruct steam outlet
Power CordDetachable, replacement by a qualified professional
Recycling InstructionsDo not dispose of with household waste, deposit at WEEE collection point

Frequently Asked Questions - 66906 Lund

What type of water to use in the humidifier?
Use cold tap water at a temperature not exceeding 35 °C. Never pour hot water to avoid burns and deformation of the tank.
Can I add essential oils or fragrances?
Yes, but only fragrances specially designed for ultrasonic humidifiers. Mix them with water outside the device before filling the tank, respecting the proportions indicated on the fragrance packaging.
How to adjust the steam intensity?
Press the button marked with a droplet after starting the device. A single beep increases intensity, a double beep decreases it.
What does the timed mode (3H, etc.) mean?
The button with the clock symbol allows you to choose an operating duration. Press successively to switch to continuous mode (LED ON) or timed mode (e.g., 3H, 6H…). The device switches off automatically after the selected time.
How to turn off the LED backlight?
Press and hold the button marked with a sun until the backlight turns off. A single press changes the color or activates automatic mode.
How often to clean the humidifier?
Empty and clean the tank at least every 3 days to prevent microbial growth. Use a tablespoon of citric acid diluted in 100 ml of hot water (70 °C) for 5 minutes, then rinse with clean water.
What to do if the device no longer produces steam?
Check that the tank is filled with water, the lid is properly closed, and the water level does not exceed the maximum. If the problem persists, unplug and clean the ultrasonic generator at the bottom of the tank with a soft cloth (without tools).
Can I use the humidifier in a humid room (bathroom)?
No, the device is designed for indoor use only in dry rooms. Avoid excessive humidity around the device and do not place it near water or rain.
How to clean the exterior of the humidifier?
Use a soft, slightly damp cloth to wipe the base and lid. Never immerse the device in water and do not use solvents, alcohol, or abrasive products.
The device has fallen or is leaking, what to do?
If the device has fallen, shows visible damage, or is leaking, stop using it immediately. Unplug it and contact an authorized service center. Do not attempt to repair it yourself.

User questions about 66906 Lund

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Humidifier in PDF format for free! Find your manual 66906 - Lund and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 66906 by Lund.

USER MANUAL 66906 Lund

natural_image Close-up of a white ceramic appliance with a cable inserted into the base (no visible text or symbols)

Lund 66906 - 1

natural_image Close-up of a transparent dome-shaped device with a label '4' pointing to it, no visible text or symbols on the device itself.

Lund 66906 - 2

natural_image Close-up of a white cylindrical electronic device with indicator lights and a label 'IVIII' in the corner (no readable text or symbols on the device itself)

Lund 66906 - 3

Czyścić zbiornik wodny co trzy dni Clean the water tank every three days Reinigen Sie den Wassertank alle drei Tage Очищайте резервуар для воды каждые три дня Очищайте резервуар для води кожні три дні Vandens baką valykite kas tris dienas Tīriet ūdens tvertni ik pēc trijām dienām Čistěte nádrž na vodu každé tři dny Nádobu na vodu čistite aspoň raz za 3 dni A víztartályt három naponta tisztítsa Curătați rezervorul de apă la fiecare trei zile Limpie el tanque de agua cada tres días Nettoyer le bac à eau tous les trois jours Pulire il serbatoio dell'acqua ogni tre giorni Maak de watertank om de drie dagen schoon Kaθαρίστε τη δεξαμενή νερού κάθε τρεις ημέρες

Lund 66906 - 4

Read the operating instruction

  1. base
  2. lid
  3. steam outlet
  4. water tank
  5. control buttons
  6. power cord
  7. power supply
  8. measuring cup

D

This symbol indicates that waste electrical and electronic equipment (including batteries and storage cells) cannot be disposed of with other types of waste. Waste equipment should be collected and handed over separately to a collection point for recycling and recovery, in order to reduce the amount of waste and the use of natural resources. Uncontrolled release of hazardous components contained in electrical and electronic equipment may pose a risk to human health and adverse effects for the environment. The household plays an important role in contributing to reuse and recovery, including of waste equipment. For more information about the appropriate recycling methods, contact your local authority or retailer.

Lund 66906 - D - 1

The aroma diffuser is a device which humidifies the air while spraying the fragrances added to the water in the device's tank. Steam is produced by means of ultrasound, so it is not hot and contact with it does not pose a risk of burns.

Read the entire manual before the first use of the device, and keep it for future reference.

The supplier shall not be liable for any damage resulting from failure to comply with the safety instructions and recommendations specified in this manual.

ACCESSORIES

The device is delivered complete but requires some preparatory activities before use. The device comes with a detachable power cord. The fragrances are not included.

SAFETY INSTRUCTIONS

Caution! Read all of the following instructions. Failure to do so may result in electrocution, fire, or personal injury.

FOLLOW THE INSTRUCTIONS BELOW

Do not use the product in an explosive environment containing flammable liquids, gases, or vapours. Make sure that the mains power parameters comply with the ones shown on the device's nameplate before connecting the device to the power supply. Before starting the device for the first time, make sure that the device, its accessories, and the power cord have not been damaged. Operating the device is forbidden if any damage is discovered. Any damaged components, including the power cord, must be replaced at an authorised facility. It is forbidden to repair the device on your own. The device is intended for indoor use only. Do not expose the device to any precipitation or moisture. The risk of electric shock is significantly increased if water and moisture enters the device. Do not immerse the product in water or any other liquid. Set the device on flat, even, and hard surfaces.

The surface should be clean as the vents, through which the air is sucked in by the device, are located at the base of the device; situations where any contaminants are sucked into the device together with air must be avoided. Contaminants can damage the device or

GB

cause fire and/or electric shock. The location for setting the device should be chosen so that the steam jet can freely humidify the air in the room. Warning! The steam outlet must not be obstructed. A minimum of 0.5 m free space above the device must be maintained so that the steam jet can escape freely. Select the location which will ensure that the power cord does not pose a risk of tripping or moving the device. When filling and cleaning the device, remove the device's power plug. Fill the device's tank with cold water only – water temperature should not exceed 35°C. Filling with hot water can cause burns and deformation of the plastic tank. Do not use flammable substances such as alcohols or solvents to fill the tank. The device's tank should be filled so that the water level does not exceed the maximum level marked on the tank wall. Overfilling the tank is forbidden. Only pure water or water mixed with a fragrance may be poured into the tank. If fragrances are used, they must be added to water outside the device, mixed and then poured into the device's tank. Use only fragrances designed for ultrasonic devices. The fragrances must be mixed with water in the proportions specified in the instructions accompanying the fragrance. Read the entire content of the fragrance instructions before use. After each application, unplug the power cord plug from the socket. Always disconnect the device from the power supply, if it is left unattended, and before putting it away, disassembling, cleaning or filling with water. Do not leave the device unattended when it is connected to the power supply. Do not overload the power cord. Do not use the power cord to carry the device, or connect or disconnect the plug from the socket. Avoid any contact between the power cord and heat sources, oil, sharp edges or moving parts. Damage to the power cord increases the risk of an electric shock. If the power cord is damaged (e.g. it is cut or its insulation is melted), immediately unplug it from the socket and return the device to an authorised service facility. It is forbidden

GB

to use the product with a damaged power cord. Repairing the power cord is forbidden. It must be replaced with a new one at an authorised service centre. Use only with the attached power supply unit. Using other power supply units is not allowed. The product must be kept under supervision at all times during operation. Do not leave the device unattended if it is connected to the power supply. The device is not to be used by children. Keep the device and its power cord out of the reach of children. It is important to ensure that children do not see the device as a toy. Children should not be allowed to clean or perform maintenance activities on the device without supervision. This device cannot be used by people with impaired physical and/or mental abilities, or by people without experience in or understanding of the operation of the device, unless they are supervised or instructed on how to safely operate the device so that they understand the relevant operating risks. The water tank cannot be opened during use. Do not use the device if it has been dropped, if there are visible signs of damage, or if it is leaking. It is important to be aware that high humidity levels can promote the growth of biological organisms in the surroundings. Do not allow the area around the humidifier to become wet or damp. If moisture is discovered, turn off the humidifier. Use the humidifier in intervals if it cannot be switched off. Moisture-absorbing materials such as carpets, curtains, drapes or tablecloths should not be allowed to become damp. Do not leave water in the tank when the device is not operating. Empty and clean the humidifier before storage. Clean the humidifier before next use.

USING THE DEVICE

Preparing the device for use

Unpack the device and remove all packaging components. It is recommended to keep the packaging for later storage. Clean the water tank, the lid, and housing according to the instructions found in the “Device maintenance” section.

Put the power cord plug into the socket on the base of the device (II). Do not connect the plug at the other end of the cord to the power supply yet. Set the device in the location where it will be used. Remove / open the device's lid (III). Fill the device's tank with water or a mixture of water and fragrance. Reattach / close the lid so

GB

that it fits the device housing's entire circumference (IV). Connect the device to the power supply by inserting the power cord plug into the socket. The device is ready for use.

Warning! Never move the device with a filled tank.

Using the device

The device has a touch panel with three buttons. The button with the clock symbol is used to start the emission of steam. The "ON" LED will light up to indicate continuous emission of steam. The subsequent pressing of the button will start the timed steam emission mode. The mode is described by the number and letter H (e.g. 3H) and indicates the number of hours after which the device will automatically switch the steam emission off. The device is switched off after touching the button the number of times required for all of the LEDs to stop illuminating the operating mode. The steam emission will stop.

The button with the droplet symbol is used to increase and decrease steam emission. The steam jet's intensity can only be set after the emission has started. If a single sound signal is heard after touching the button, it means a higher intensity of the steam jet. A double sound signal means less intense steam jet.

The button with the sun symbol turns on the backlight and allows to control it. The first touch of the button activates the automatic backlight colour change mode, the next touch stops the automatic backlight colour change and leaves the backlight in the selected colour. The next touch of the button changes the intensity and colour of the backlight. The backlight is switched off by touching and holding the button until the backlight is switched off.

DEVICE MAINTENANCE

Caution! All maintenance works must be carried out with the device's electric power supply disconnected. Pull the plug from the power socket and disconnect the cord from the device.

Carefully open/remove the lid and pour water out of the device's tank. Water should be removed from the tank not less frequently than every three days. Do not keep the water in the tank due to the possibility of growth of microorganisms. Before refilling, clean the tank with clean water. Remove any scale, sediments or film which has accumulated on the walls or inside the tank. Then wipe the tank dry. Pour one tablespoonful of citric acid into the tank and 100 ml of warm water with the temperature not exceeding 70°C. Mix the acid and leave the solution in the tank for 5 minutes. Next, empty the tank, rinse with clean water, and wipe dry omitting the opening in the bottom of the tank under which the ultrasonic generator is mounted. This manner of maintaining the tank will allow to keep it clean, reduce the growth of microorganisms, and prevent the build-up of scale in the tank. Never use solvents, acids, or alcohol for cleaning. Clean the base and the lid with a soft, damp cloth. Never immerse the device in water or any other liquid. After cleaning, leave the lid and the base with the tank to dry completely. Store the device in a place protected from dust, moisture, and direct sunlight. Before first use, wipe the inside of the tank with a damp cloth.

TECHNICAL DATA

Parameter Unit Value
Catalogue No. 66906
Rated voltage [VDC] 24
Rated current [mA] 650
Container capacity [ml] 1000
Steam emission capacity [ml/h] 70
Operation area [m] ^2 ]50
Weight [kg] 0,5
Power supply
Rated input voltage [V~] 110 – 240
Rated frequency[Hz]50 – 60
Rated current[A]0,4
Rated output voltage [VDC] 24
Output current[mA] 500
Protection classII