66901 - Humidifier Lund - Free user manual and instructions
Find the device manual for free 66901 Lund in PDF.
Frequently Asked Questions - 66901 Lund
Download the instructions for your Humidifier in PDF format for free! Find your manual 66901 - Lund and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 66901 by Lund.
USER MANUAL 66901 Lund
ORIGINAL INSTRUCTIONS DEVICE FEATURES The aroma diff user is a device which humidifi es the air while spraying the fragrances added to the water in the device’s tank. Steam is produced by means of ultrasound, so it is not hot and contact with it does not pose a risk of burns. Read the entire manual before the fi rst use of the device, and keep it for future reference. The supplier shall not be liable for any damage resulting from failure to comply with the safety instructions and recommendations specifi ed in this manual. ACCESSORIES The device is delivered complete but requires some preparatory activities before use. The device comes with a detachable power cord. The fragrances are not included. SAFETY INSTRUCTIONS Caution! Read all of the following instructions. Failure to do so may result in electrocution, fi re, or personal injury.
FOLLOW THE INSTRUCTIONS BELOW
Do not use the product in an explosive environment containing fl am- mable liquids, gases, or vapours. Make sure that the mains power parameters comply with the ones shown on the device’s nameplate before connecting the device to the power supply. Before starting the device for the fi rst time, make sure that the device, its accessories, and the power cord have not been damaged. Operating the device is forbidden if any damage is discovered. Any damaged components, including the power cord, must be replaced at an authorised facility. It is forbidden to repair the device on your own. The device is intended for indoor use only. Do not expose the device to any precipitation or moisture. The risk of electric shock is signifi cantly increased if water and moisture enters the device. Do not immerse the product in water or any other liquid. Set the device on fl at, even, and hard surfaces. The surface should be clean as the vents, through which the air is sucked in by the device, are located at the base of the device; situa- tions where any contaminants are sucked into the device together with air must be avoided. Contaminants can damage the device orGB
ORIGINAL INSTRUCTIONS cause fi re and/or electric shock. The location for setting the device should be chosen so that the steam jet can freely humidify the air in the room. Warning! The steam outlet must not be obstructed. A minimum of 0.5 m free space above the device must be maintained so that the steam jet can escape freely. Select the location which will ensure that the power cord does not pose a risk of tripping or moving the device. When fi lling and cleaning the device, remove the device’s power plug. Fill the device’s tank with cold water only – water temperature should not exceed 35
C. Filling with hot water can cause burns and deformation of the plastic tank. Do not use fl ammable substances such as alcohols or solvents to fi ll the tank. The device’s tank should be fi lled so that the water level does not exceed the maximum level marked on the tank wall. Overfi lling the tank is forbidden. Only pure water or water mixed with a fragrance may be poured into the tank. If fragrances are used, they must be added to water outside the device, mixed and then poured into the device’s tank. Use only fragrances designed for ultrasonic devices. The fragrances must be mixed with water in the proportions speci- fi ed in the instructions accompanying the fragrance. Read the entire content of the fragrance instructions before use. After each applica- tion, unplug the power cord plug from the socket. Always disconnect the device from the power supply, if it is left unattended, and before putting it away, disassembling, cleaning or fi lling with water. Do not leave the device unattended when it is connected to the power sup- ply. Do not overload the power cord. Do not use the power cord to carry the device, or connect or disconnect the plug from the socket. Avoid any contact between the power cord and heat sources, oil, sharp edges or moving parts. Damage to the power cord increases the risk of an electric shock. If the power cord is damaged (e.g. it is cut or its insulation is melted), immediately unplug it from the socket and return the device to an authorised service facility. It is forbiddenGB
ORIGINAL INSTRUCTIONS to use the product with a damaged power cord. Repairing the power cord is forbidden. It must be replaced with a new one at an autho- rised service centre. Use only with the attached power supply unit. Using other power supply units is not allowed. The product must be kept under supervision at all times during operation. Do not leave the device unattended if it is connected to the power supply. The device is not to be used by children. Keep the device and its power cord out of the reach of children. It is important to ensure that children do not see the device as a toy. Children should not be allowed to clean or perform maintenance activities on the device without supervision. This device cannot be used by people with impaired physical and/or mental abilities, or by people without experience in or understanding of the operation of the device, unless they are supervised or instruc- ted on how to safely operate the device so that they understand the relevant operating risks. The water tank cannot be opened during use. Do not use the device if it has been dropped, if there are visible signs of damage, or if it is leaking. It is important to be aware that high humidity levels can promote the growth of biological organisms in the surroundings. Do not allow the area around the humidifi er to become wet or damp. If moisture is discovered, turn off the humidifi er. Use the humidifi er in intervals if it cannot be switched off . Moisture-absorbing materials such as carpets, curtains, drapes or tablecloths should not be allowed to become damp. Do not leave water in the tank when the device is not operating. Empty and clean the humidifi er before storage. Clean the humidifi er before next use.
Preparing the device for use Unpack the device and remove all packaging components. It is recommended to keep the packaging for later storage. Clean the water tank, the lid, and housing according to the instructions found in the “Device maintenance” section. Put the power cord plug into the socket on the base of the device (II). Do not connect the plug at the other end of the cord to the power supply yet. Set the device in the location where it will be used. Remove / open the device’s lid (III). Fill the device’s tank with water or a mixture of water and fragrance. Reattach / close the lid soGB
ORIGINAL INSTRUCTIONS that it fi ts the device housing’s entire circumference (IV). Connect the device to the power supply by inserting the power cord plug into the socket. The device is ready for use. Warning! Never move the device with a fi lled tank. Using the device The device has two buttons. The button with “MIST” or “MIST/TIMER” written on it is used to start the emission of the steam jet. Pressing this button again will switch to the next steam jet emission mode, which will be indicated by lighting up the mode designation. WARNING! Do not exceed 6 hours of continuous steam emission. After this time, switch off the device for at least one hour. The device is switched off by pressing the “MIST” or “MIST/TIMER” button several times so that none of the operating modes are illuminated. The steam emission will be stopped and the quiet hum of the device’s fans will no longer be heard. The device has a sensor to check whether there is water in the tank. If a lack of water is detected in the tank, the device will not start the ultrasonic generator. The “LIGHT” button turns on the backlight and allows to control it. The fi rst press of the button activates the automatic backlight colour change mode, the next press stops the automatic backlight colour change and leaves the backlight in the selected colour. The next press of the “LIGHT” button changes the intensity and colour of the backlight. The backlight is switched off by pressing and holding the “LIGHT” button until the backlight is switched off . DEVICE MAINTENANCE Caution! All maintenance works must be carried out with the device’s electric power supply disconnected. Pull the plug from the power socket and disconnect the cord from the device. Carefully open/remove the lid and pour water out of the device’s tank. Water should be removed from the tank not less frequently than every three days. Do not keep the water in the tank due to the possibility of growth of microorganisms. Before refi lling, clean the tank with clean water. Remove any scale, sediments or fi lm which has accumulated on the walls or inside the tank. Then wipe the tank dry. Pour one tablespoonful of citric acid into the tank and 100 ml of warm water with the temperature not exceeding 70
C. Mix the acid and leave the solution in the tank for 5 minutes. Next, empty the tank, rinse with clean water, and wipe dry omitting the opening in the bottom of the tank under which the ultrasonic generator is mounted. This manner of maintaining the tank will allow to keep it clean, reduce the growth of microorganisms, and prevent the build-up of scale in the tank. Never use solvents, acids, or alcohol for cleaning. Clean the base and the lid with a soft, damp cloth. Never immerse the device in water or any other liquid. After cleaning, leave the lid and the base with the tank to dry completely. Store the device in a place protected from dust, moisture, and direct sunlight. Before fi rst use, wipe the inside of the tank with a damp cloth.GB
ORIGINAL INSTRUCTIONS TECHNICAL DATA Parameter Unit Value Catalogue No. 66901 Rated voltage [VDC] 24 Rated current [mA] 650 Container capacity [ml] 120 Steam emission capacity [ml/h] 30 Operation area [m
ManualGo.com