Güde GP 6035 - Water pump

GP 6035 - Water pump Güde - Free user manual and instructions

Find the device manual for free GP 6035 Güde in PDF.

📄 84 pages English EN Download 💬 AI Question
Notice Güde GP 6035 - page 17

User questions about GP 6035 Güde

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

L'email reste privé : il sert seulement à vous prévenir si quelqu'un répond à votre question.

No questions yet. Be the first to ask one.

Download the instructions for your Water pump in PDF format for free! Find your manual GP 6035 - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GP 6035 by Güde.

USER MANUAL GP 6035 Güde

Translation of the original instructions

35 °C IP X4 Read and understand the opera- ting instructions before using the appliance.Abide by all the safety measures stated in the service manual. Act responsib- ly toward third parties. In case of any doubts about connection and operati- on refer please to our customer center Specied Conditions Of Use The pump is solely used for drainage and for pum- ping into and out of containers in the house, garden, farm and agriculture and only for water.Respecting technical data and safety precautions. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages. The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sucient idle periods between cycles of operation. Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it. Do not use the pump for drinking water! The pump must not be connected to the existing water-supply network as a pressure- boosting device. Never use the pump as a pool circulation pump. Safety Instructions WARNING! Electric shock! There is a risk of an injury caused by electric shock! This device is not intended for use by persons (inclu

ding children) with limited physical, sensory or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device. Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorised persons out of reach of the appliance. Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA). Please ask your electrician. Before putting into operation, a qualied electrician must check whether electric safety measures required are in place.Any national regulations in this regard must be complied with. Electric connection to a socket. Do not expose the appliance to rain and do not use it in wet or moisture conditions.14 ENGLISH

It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity. Avoid installing the appliance in wet shafts (risk of short circuit, corrosion eects)! Check the voltage. Technical data given on the type label must correspond with electric network voltage. Only use splash proof extension cables approved for outdoor purposes. Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid! Check the cable and/or socket for damages before the appliance putting into operation. To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself. Protect the feeder cable from excessive temperatures, oil and sharp edges. If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.). The pump must not in any case run without llings. Do not leave the pump unattended while in operati

on in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it. The temperature of the drained liquid must not exceed +35 °C. When using the pump for domestic water supply, always observe the local regulations of water ma

nagement authorities and the waste water drainage. If the pump is used in ponds, wells, etc. and appropri

ate pumping stations, standards valid for pumps in the given country must unconditionally be observed. Do not use pump at outside temperatures over 40 °C or under 0 °C In cold weather, the pumping body motor should not be wrapped in a blanket or another piece of textile with intent to prevent the water freezing. The user is responsible to third parties if pump (dum

ping stations, etc.) is used. Requirements for operating sta The operating sta must carefully read the Opera- tingInstructions before using the appliance. Qualication : Apart from the detailed instructions by aprofessional, no special qualication is necessary forappliance using. Minimum age : Persons over 16 years of age can only workon the appliance.An exception includes youngsters trained in order to reachknowledge under supervision of the trainer duringoccupational education. Training : Using the appliance only requires corre- spondingtraining by a professional or the Operating Instructions. Nospecial training is necessary. Emergency procedure Conduct a rst-aid procedure adequate to the injury and summon qualied medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, inaccordance with DIN13164, a workplace has to be ttedwith a rst-aid kit. It isessential to replace any usedmaterial in the rst-aid kitimmedia- tely after it has been used. If you seek help,state the following pieces ofinformation::

3. Number of injured persons

Symbols Read the Operating Instructions Before carrying out any work on the machi- ne, disconnect the plug from the socket. Cable pulling / transport prohibited Not frost-resistant 35˚C

The temperature of the drained liquid must not exceed +35 °C. Caution!Not too strong and not tighten with pliers. Staying in the transportation medium prohibited15 ENGLISH

Guarantee Warranty period of 12 months applies to commercial use and 24 months applies to private use and com- mences on the day of purchase of the device. The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be sub

mitted for any claim in the guarantee period. The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the ope

rating and assembly instructions and common wear are also not included in the guarantee. GÜDE cannot be held responsible for damages incurred in consequence of unqualied installation or unskilled handling of the pump. The device has to be checked on a regular basis to ensure perfect functioning. Let us refer to the fact we do not assume any respon

sibility – according to standards in force – for damage eventually caused by our appliances in the below- mentioned cases:• Unprofessional repairs executed by unauthorised service centres;• Use in conict with the designed purpose, or failure to observe the use as designed;• Pump overload with a continuous run;• Damage as a result of icing or any other fault caused by climatic inuences; Identical regulations apply for accessory parts. To prevent damage (such as ooded rooms, etc.) as a result of faulty pump operation (failure or fault) the ow

ner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.). Disposal The disposal instructions are based on the icons placed on the appliance or on the package. Descrip- tion of the respective meanings can be found in the section „Marking“. Any damaged or disposed devices must be delivered to appropriate collection centres. Transport packaging disposal The packaging protects the machine against damage during transport. Packaging materials are usually chosen based on environment aspects and waste treatment principles and are therefore recyclable. Re

turning the packaging into material circulation saves raw materials and reduces waste production. Parts of packagings (e.g. foils, styropor®) can be dangerous for children. Warning against dangerous electric voltage Warning against automatic starting Accessories - not included in the supply; recommended equipment specied in the list of accessories Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres. Protect against humidity This side up Maintenance Before carrying out any work on the machine, disconnect the plug from the socket. Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug. The machine must not be used under any circum

stances if the machine or the safety devices are damaged. In case of a failure of the pump, a repair can only be executed by the GÜDE service centre. Original spare parts to be used only. Caution: Standing water may corrode (brownish colour) in the pump according to design. At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil). Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insucient mainte

nance and care can lead to unforeseen accidents and injuries.16 ENGLISH

Important information for the customer Please be sure to know that returning the product in or after the warranty period must be made in the original packaging. Inspection and maintenance plan Time interval Description Any other details As needed Clean the check valve and the prelter. Check the check valve function. Failures – causes - removal Failures Causes Removal Engine does not start No power supply. Blocked pump wheel Turn the engine shaft with screwdri- verthrough the fan cover (to release frictioncircles sealing that may be stuck together). Pump does not suck Missing, loose or blocked check valve Check valve is not in water. No water in the pump shell. Too high suction head. Air bubbles in the suction pipeline. Connections not sealed, pump sucks air, pump is not deaerated. Fix or clean the check valve. Immerse the check valve into water. Fill the pump shell with water. Check the suction head. Check the tighten of suction pipeline. Carefully repeat connection according to thechapter „Connection“! Thermal detector swit- ching the pump o

Pump is overheated and switched o by thethermal overloading protection. No electric power supply. Impurity particles (e.g. pebbles) have settleddown in the suction hole. Let the device getting cool! Check the voltage Saugschlauch reinigen, Ansaugen vonFremdstoen verhindern. Wasser-Fördermenge ungenügend Too high suction head. Water level drops quickly. Check the suction head. Clean the pump and replace worn parts. (qualied workshop) Risk of suocation! Keep parts of the packagings out of reach of children and dispose them as soon as possible. Service Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bure- aucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference Serial No.: Art. No: Year of production: F17 FRANÇAIS

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Güde

Model : GP 6035