USER MANUAL PMSHM 2 A1 PARKSIDE
BAU- UND HOLZFEUCHTEMESSGERÄT / MOISTUREMETER/HUMIDIMÉTRE PMSHM 2 A1
DE AT CH
BAU- UND HOLZFEUCHTEMESSGERÄT
Operation and safety notes
FR BE
HUMIDIMÉTRE
GB/IEOperation and safety notesPage 22
EXPLOSIONSGEFAHR! Laden
Intended use.. Page 23
Parts description.. Page 23
Technical data.. Page 24
Scope of delivery.. Page 25
General safety instructions
Safety instructions for batteries / rechargeable batteries... Page 26
Before use.. Page 27
Inserting / changing the batteries.. Page 27
Start-up Page 28
Before you take a measurement......Page 28
Taking a measurement.. Page 29
Battery display.. Page 31
Temperature display.. Page 31
Reset function . Page 31
Troubleshooting Page 32
Cleaning and care... Page 33
Storage Page 33
Disposal.. Page 33
Warranty.. Page 35
Warranty claim procedure......Page 35
Service.. Page 36
| List of pictograms used | |
| --- | Direct current/voltage |
| - +b | Batteries included |
Moisture Meter
Introduction
We congratulate you on the purchase of your new product. You have chosen a high quality product. The instructions for use are part of the product. They contain important information concerning safety, use and disposal. Before using the product, please familiarise yourself with all of the safety information and instructions for use. Only use the unit as described and for the specified applications. If you pass the product on to anyone else, please ensure that you also pass on all the documentation with it.
Intended use
This product is suitable for measuring wood and building moisture, for example in firewood, mortar, concrete or plaster. The product is only intended for use in private households, and not intended for commercial use. This product is only for indoor use.
Parts description
1 Protective cap 2 Measuring pins
3 M/°C/°F button (Material selection, °C or °F selection)
4 ton (ON/OFF, Freeze the measured value on the display)
5 RESET button
6 Battery compartment cover
7 Battery compartment
8 Display
9 Moisture indicator in %
10 Material number
11 Low battery indicator
12 Lock symbol (Measured value frozen)
13 Temperature display (^ or ^ F)
Technical data
Operating voltage: 3V
Battery type: 2 × LRO3 / AAA
Temperature accuracy: + / - 1^
Humidity accuracy: A: building material
below 1.4% + / - 0.3%
over 1.4% + / - 0.5%
B: wood material
below 30% .. + / - 2%
over 30% .. + / - 4%
Precision: see chapter "Making
measurements"
Operating temperature: 0^ to 40^
Protection class: IP 20
Resolution: 0.1%
Air humidity: up to a maximum of
80% (relative)
- Scope of delivery
Immediately after unpacking please check the package contents for completeness and if all parts and the product are in good condition.
1 Moisture Meter
2 LRO3/AAA batteries
1 Instructions for use

General safety instructions
Before using the product, please familiarise yourself with all the operating and safety instructions. Please include all documentation when passing this product on to others.
Check the product for damage before use. If the product is damaged do not use it.
Do not expose the product to moisture. Otherwise the product could be damaged.
This product may be used by children age 8 years and up, as well as by persons with reduced physical, sensory or mental capacities, or lacking experience and / or knowledge, so long as they are supervised or instructed in the safe use of the product and understand the associated risks. Children should not be allowed to play with the product. Cleaning and user maintenance should not be performed by children without supervision.
WARNING! The measuring pins are very sharp. Always be careful when using this product. Always attach the protective cap to the product when not in use. Otherwise there is a risk of injury!

Safety instructions for batteries/rechargeable batteries
DANGER TO LIFE! Keep batteries/rechargeable batteries out of reach of children. If accidentally swallowed seek immediate medical attention.
- Swallowing may lead to burns, perforation of soft tissue, and death. Severe burns can occur within 2 hours of ingestion.

DANGER OF EXPLOSION!
Never recharge non-rechargeable batteries. Do not short-circuit batteries/rechargeable batteries and/or open them. Overheating, fire or bursting can be the result.
Never throw batteries / rechargeable batteries into fire or water.
Do not exert mechanical loads to batteries / rechargeable batteries.
Risk of leakage of batteries / rechargeable batteries
Avoid extreme environmental conditions and temperatures, which could affect batteries / rechargeable batteries, e.g. radiators / direct sunlight.
If batteries / rechargeable batteries have leaked, avoid contact with skin, eyes and mucous membranes with the chemicals! Flush immediately the affected areas with fresh water and seek medical attention!

WEAR PROTECTIVE GLOVES!
Leaked or damaged batteries / rechargeable batteries can cause burns on contact with the skin. Wear suitable
protective gloves at all times if such an event occurs.
In the event of a leakage of batteries / rechargeable batteries, immediately remove them from the product to prevent damage.
Only use the same type of batteries / rechargeable batteries. Do not mix used and new batteries / rechargeable batteries.
Remove batteries / rechargeable batteries if the product will not be used for a longer period.
Risk of damage of the product
Only use the specified type of battery / rechargeable battery!
Insert batteries / rechargeable batteries according to polarity marks (+) and (-) on the battery / rechargeable battery and the product.
Use a dry lint-free cloth or cotton swab to clean the contacts on the battery / rechargeable battery and in the battery compartment before inserting!
Remove exhausted batteries/rechargeable batteries from the product immediately.
Before use
Before initial use, remove the protective film from the product display 8 and insert the enclosed batteries.
- Inserting / changing the batteries
If the low battery indicator 11 appears in the display 8, the inserted batteries are almost drained and
must be replaced. Empty batteries can falsify the measured result.
To insert the batteries proceed as follows:
Open the battery compartment cover on the back of the product.
Remove the used batteries.
Insert 2 pcs of LRO3 / AAA batteries with observe the correct polarity.
Insert the batteries in the battery compartment 7 and close the battery compartment cover 6 again, so that it audibly latches into place.
Note: No button should be pressed while inserting the batteries.
- Start-up
Before you take a measurement
Ensure that both measuring pins 2 touch the surface of the material at the same time.
Increase the pressure on the measuring pins 2 for rough surfaces if necessary.
For delicate surfaces complete the measurement on a section that is not in the visible area.
Note: The measuring pins 2 are sharp and may dent or damage the surface.
- Rub the damp residue on the surface before taking the measurement.
Measure several places and take an average value. - Be aware that salts can increase the conductivity of water. This can lead to incorrect readings and results that are too high.
Remove the bark from firewood if needed. Press the measuring pins 2 against the grain in various places on the wood.
- Taking a measurement
Pressthe but 4 to turn on the product. On the display 8 "0.0%", the surrounding temperature in ^ C and the previously selected material 1-6 (see table reference values) appears.
Press the M / ^ / ^ button 3 and hold it down for approximately 5 seconds to switch the temperature display between ^ C and ^
Press the M/°C/°F button 3 to select the material number of which you wish to measure the moisture level.
| Wood moisture approximate value for firewood | |||
| √ | 6-15% | ideal for heating - high heating value | |
| √ | 16-20% | restricted heating - low heating value | |
| X | 21-44% | not suitable for heating - further drying necessary | |
Note: Above table is reference for checking the status of firewood. If the measured wood moisture level is 15% or below, the firewood is ideal for heating. If the measured wood moisture level is from 16 to 20% , the firewood is medium dry. If the measured wood moisture level is 21% or above, the firewood is not suitable for heating and further drying is necessary.
| Number | Material | Measuring range | Reference values for humidity expressed in per cent by weight | ||
| dry borderline too humid | |||||
| 1 | birch, beech, cherry, larch, spruce, walnut | 6-44%<12%12-15%>15% | |||
| 1 | oak, pine, maple, ash, Douglas fir | 6-44%<15%15-20%>20% | |||
| 2 | Cement screed, concrete | 1.4-7.4%<2%2-4%>4% | |||
| 3 | Anhydride screed, plaster/Plasterboard | 0.0-4.1%<0.5%0.5-1%>1% | |||
| 4 | Cement mortar | 0.8-5.1%<2%2-5%>5% | |||
| 5 | Lime mortar | 0.4-3.7%<2%2-3.5%>3.5% | |||
| 6 | Brick | 0.0-8.5%<1%1-3%>3% | |||
Note: When measuring under the measurement range, the display 8 shows "0.0%" or "Lo". For measurements above the measurement range, the display 8 shows "Hi".
Remove the protective cap 1.
Press both measuring pins 2 against the surface at the same time. After 1-2 seconds you can read the percentage value.
If you are taking a measurement in an area in which you cannot read the display 8, press
the 4 to freeze the result on the display 8. The display 8 will then also show the lock symbol 12
Press 4 again to take another measurement.
If you have completed your measurement, switch the moisture measuring product off by pressing holding the button for more than 5 seconds.
Note: The moisture measuring product switches itself off automatically if the product is not used for 60 seconds approximately.
Batterydisplay
If the battery charge status is low, the low battery indicator 11 appears on the display 8. Please note that while the batteries are low, the measured values will be false or inaccurate. Replace the batteries as quickly as possible if this display appears. The battery change is described in the section "Inserting / changing the batteries".
Temperaturedisplay
You can change the temperature display between ^ C and ^ F by holding down M/°C/°F button 3 for approximately 5 seconds.
Resetfunction
A calibration can be performed if 0.0% is not shown on the display 8 right after turn ON the product. For this, open the battery compartment
cover 6 and press the reset button 5 situated on the backside of the product using a sharp object. If the displayed reading is still not right, press the reset button 5 again to calibrate again.
Note: Do not remove the batteries while using RESET function.
- Troubleshooting
| Error Possible causes and solutions |
| The measure-ment is obvi-ously too high or low. |
| Check whether the product is set to the correct material. Check if the measuring pins 2 are correctly pressed against the material. Repeat the measurement process. |
| The display 8 is reading "Lo" or "Hi". |
| The measurement range has been exceeded or you have not reached the measuring range. |
| The number on the display 8 is not re-acting. |
| If the lock symbol 12 appears on the display 8, press the button 4. |
| You can barely see the number on the display 8. |
| The batteries are low. See the chapter "Inserting/ changing the batteries". |
Electrostatic discharges can lead to malfunctions. In the event of such malfunctions, remove the batteries briefly and reinsert them.
- Cleaning and care
Do not allow liquids to enter the product.
Otherwise the product may be damaged.
Only clean the product with a slightly dampened cloth and mild washing-up liquid.
Clean the measuring pins with a slightly dampened cloth and dry it afterwards.
Check the product for visible external damage before every use.
Check the measuring pins for damage before every use.
Storage
Always attach the protective c to the product when not in use.
Always remove the batteries if the product will not be used for extended periods.
Store the product in a dry location.
Disposal
The packaging is made entirely of recyclable materials, which you may dispose of at local recycling facilities.

Observe the marking of the packaging materials for waste separation, which are marked with abbreviations (a) and numbers (b) with following meaning: 1-7: plastics / 20-22: paper and fibreboard/80-98: composite materials.

The product and packaging materials are recyclable, dispose of it separately for better waste treatment. The Triman logo is valid in France only.

Contact your local refuse disposal authority for more details of how to dispose of your worn-out product.

To help protect the environment, please dispose of the product properly when it has reached the end of its useful life and not in the household waste. Information on collection points and their opening hours can be obtained from your local authority.
Faulty or used batteries / rechargeable batteries must be recycled in accordance with Directive 2006/66/EC and its amendments. Please return the batteries / rechargeable batteries and/or the product to the available collection points.

Environmental damage through incorrect disposal of the batteries/rechargeable batteries!
Batteries / rechargeable batteries may not be disposed of with the usual domestic waste. They may contain toxic heavy metals and are subject to hazardous waste treatment rules and regulations. The chemical symbols for heavy metals are as follows: Cd = cadmium, Hg = mercury, Pb = lead. That is why you should dispose of used batteries / rechargeable batteries at a local collection point.
Warranty
The product has been manufactured to strict quality guidelines and meticulously examined before delivery. In the event of product defects you have legal rights against the retailer of this product. Your legal rights are not limited in any way by our warranty detailed below.
The warranty for this product is 3 years from the date of purchase. The warranty period begins on the date of purchase. Please keep the original sales receipt in a safe location. This document is required as your proof of purchase.
Should this product show any fault in materials or manufacture within 3 years from the date of purchase, we will repair or replace it - at our choice - free of charge to you. This warranty becomes void if the product has been damaged, or used or maintained improperly.
The warranty applies to defects in material or manufacture. This warranty does not cover product parts subject to normal wear, thus possibly considered consumables (e.g. batteries) or for damage to fragile parts, e.g. switches, rechargeable batteries or glass parts.
Warranty claim procedure
To ensure quick processing of your case, please observe the following instructions:
Please have the till receipt and the item number (e.g. IAN 123456_7890) available as proof of purchase.
You will find the item number on the rating plate, an engraving on the front page of the instructions for use (bottom left), or as a sticker on the rear or bottom of the product.
If functional or other defects occur, please contact the service department listed either by telephone or by e-mail.
You can return a defective product to us free of charge to the service address that will be provided to you. Ensure that you enclose the proof of purchase (till receipt) and information about what the defect is and when it occurred.
Service
GB Service Great Britain
Tel.: 08000569216
E-Mail: owim@lidl.co.uk
IE Service Ireland
Tel.:1800200736
E-Mail: owim@lidl.ie
C
NOSTE OCHRANNÉ RUKA-
VICE! Vyteklé i poškozené baterie
nebo akumulatory mohou pri kon
NOSTE OCHRANNÉ RUKA-
VICE! Vytečene alebo poskodené batarie/akumulátorové batérié