USER MANUAL MODEL AC25 Baby Movement Monitor with Video & Sound IMPORTANT Angelcare baby monitors are lifestyle products intended to assist parents and carers in a baby’s daily care. The Monitor alerts parents/carers after 20 seconds if no movement is detected through the mattress. The monitors are not a substitute for parental or medical supervision. This product is NOT intended and should NOT be used to prevent sudden infant death syndrome (SIDS). This product is NOT intended to diagnose, treat, mitigate, cure or prevent any disease or condition. This is a product to monitor the movement of healthy babies and is not a substitute for parental care. Product suitable for children up to 18 months. The movement feature functions only with standard cot sprung and foam mattresses. AC25_BabyMovementMonitor_Manual_Final.indd 1AC25_BabyMovementMonitor_Manual_Final.indd 1 2023-07-12 13:472023-07-12 13:472 | USER MANUAL
3. X 1 Parent Unit (with Li-ion, 3.7V 3000mAh Battery inserted ready for use, please note
you will need to charge the unit for at least 8 hours prior to first use)
4. X 1 Movement Sensor Pad (with CR2450 3V battery inserted ready for use, please note
you will need to remove the plastic tab prior to use)
5. Hardware (for wall mounting)
- Hardboard if the cot does not have a firm surface underneath the matteress.
- Drill and Screwdriver for the wall mounting (if required)
TURNING ON YOUR MONITOR
1. The Nursery Unit & Parent Unit come pre paried.
2. To turn on your Parent Unit press the middle button for 5 seconds.
3. To turn on your Nursery Unit press the middle button for 5 seconds.
SETTING UP THE NURSERY UNIT
Tabletop Movement Pad Wall-Mounted (The mounting height of the Nursery Unit should be less than 2 metres.) Place the Nursery Unit and Adaptor cord at least 1metre from the cot.
AC25_BabyMovementMonitor_Manual_Final.indd 2AC25_BabyMovementMonitor_Manual_Final.indd 2 2023-07-12 13:472023-07-12 13:47ANGELCARE – Model AC25 | 3 SETTING UP & CHANGING THE SENSOR PAD BATTERY The sensor pad is designed to detect subtle baby movements on the surface of the mattress. The alarm will only sound if no movements are detected after 20 seconds.1.21 SETTING UP
1. Remove the tab from the battery holder.
2. Remove the mattress from the cot, and place the sensor pad (Angelcare logo side up) on
the base in the centre of the mattress, it should be centred on the hardboard.
1. Use a sharp object to slide the dual lock up into the unlocked position (see image1&2)
and at the same time use a coin to remove the battery cover and insert the battery face with the + face up.
2. Replace the battery cover align 2 dots and click to secure also ensure the dual lock is
down in the locked position (see image 3&4) IMPORTANT INFORMATION
- Sources of vibration & movement other than your baby can be detected by the Movement Pad and interfere with the performance of your Angelcare monitor. The alarm will not sound if it detects movement other than your baby’s.
- There are 4 sensitivity settings. The unit is set at level 3 (default) and can be adjusted accordingly.
- The Movement Pad will detect false movements if you are touching the cot.
- The Monitor will produce a single beep tone designed to alert parent/carer if no movement is detected for 15 seconds. If no further movement is detected, the main alarm will sound at 20 seconds - a series of continuous beeps.
We reccomend you perform this test when setting up your monitor for the first time.
1. Remove the mattress from the cot and place the Movement Sensor Pad at the approx-
imate centre of baby’s sleeping area, once the Sensor Pad is placed put the mattress back in place on top of the sensor pad. Correct positioning for slatted base
2. Switch ON both Nursery & Parent Units – check both units are paired (connected).
3. Immediately pat your hand lightly and continuously on a corner of the mattress to detect
4. Step away from the cot.
5. The alarm will sound from the Nursery and Parent Unit after 20 seconds. If the Alarm
does not sound, ensure everything is setup correctly and try again; check battery levels on all units, – the sensitivity setting may require lowering by a single level due to other vibrations/movements.
6. If the alarm sounds, pat your hand lightly on the same corner of mattress to detect move-
ment again. It may take up to 8 seconds to recognise movement and for alarm to stop.
7. If the alarm continues, even after lightly patting the corner of your mattress twice, adjust
the sensitivity higher and repeat this test.
8. Repeat this process in all 4 corners of your matress to esnure the sensor pad is reaching
the whole surface of the matress. Visit Angelcarebaby.com and go to the helpcentre to watch videos for these steps. IMPORTANT INFORMATION
- Test your monitor before first use.
- Prior to use and on a regular basis (before placing your child in the cot) always check the Movement Pad is detecting no movements or vibrations in its environment.
- Test your monitor every time you move the Movement Pad to a different place.
- If your cot does not have a solid, flat, firm surface including a spring or slat base, place a hardboard between the cot base and the Movement Pad, to ensure correct operation. The hardboard must measure at least 30 x 30 cm and 6 mm thick.
- The Movement Pad functions with standard cot sprung and foam mattresses and not memory foam (partial or full), hollow frame construction mattresses and water beds. AC25_BabyMovementMonitor_Manual_Final.indd 4AC25_BabyMovementMonitor_Manual_Final.indd 4 2023-07-12 13:472023-07-12 13:47ANGELCARE – Model AC25 | 5
HOW THE SENSOR PAD WORKS
Once your sensor pad has been placed under the matress and you have completed your four corner test the unit should be ready to use. The clever sensor pad technology will track the baby’s movements across the whole surface of the matress. If after 15 seconds baby’s movement become untrackable a small beep will alarm to rouse baby to move, if the lack of movements continue for a further 5 seconds an alarm and warning will sound on your Parent Unit, meaning you should urgently check on your baby.
3. Power LED (Green)
8. Infrared LEDs x 6pcs.
- This is managed by a setting on the Parent Unit. - If the temperature colour alert setting on the Parent Unit is on, the Nursery Unit will glow Blue (too cold) or red (too hot).
- This will glow green to indicate the Nursery Unit is on.
4. Pause/Pairing Button
- PAUSE mode-Press pause key to pause sensor pad movement detection. Press again to un-pause. During PAUSE mode, Power LED is blinking slowly.
- Hold this button for 5 seconds to turn the unit on or off.
10. Night Light Button
- You can turn the night light on and off with this button (there is also a setting feature on the Parent Unit) AC25_BabyMovementMonitor_Manual_Final.indd 5AC25_BabyMovementMonitor_Manual_Final.indd 5 2023-07-12 13:472023-07-12 13:476 | USER MANUAL Parent Unit
(Dual colors – Green & Blue) - When the movement detection is ON, a Green LED blinks when the sensor pad detects movement. - When the Parent Unit is off this LED also detects charging status - When the Parent Unit battery is charging, LED indicator is steady Light Blue. If battery is fully charged, the LED indicator will be steady Green for 15 seconds then off.
- This light will be a steady green, to show the Unit is on.
3. Sound Level LED’s
- This will light green when sound is detect- ed on the Nursery Unit.
- Press to increase the speaker volume level. - Press to scroll to change the setting in menu mode. - PAN & TILT mode, press to tilt up the viewing object.
7. Left Button / Enable Pan
& Tilt Key - Press to scroll left to select a function in menu mode. - When pressed the ZOOM mode button, Press this left button to enter into PAN & TILT mode, you can then use this button to pan left the viewing object.
- Press to decrease the speaker volume level. - Press to scroll down to change the setting in menu mode. - PAN & TILT mode, press to tilt down the viewing object.
12. Power On/Off Button
- Press and hold for 5 seconds to turn the unit on or off. - Quickly press and release to turn off the screen this feature works if you have selected sleep mode on from a setting in the Parent Unit) if you then want the screen to come back on press any button.
2. Nursery Unit selected
and broadcasting sound
detection is activated
6. Movement Pad alert
12. VOX Sound is activated
13. VOX Video is activated
18. Night vision is activated
22. Parent Unit battery
- Press UP or DOWN keys to change setting.
- After deciding your setting, select Exit icon and press MENU/OK button to exit and save the new setting.
1.1 this button will be available in every submenu to take you back to the main menu
or exit from the main menu.
2. Sensor Pad Settings
2.1 Exit to main menu and save the new setting.
2.2 Movement detection
2.3 Tic Function Sound Mode (If movement
detection is activated, allows you to hear a Tic sound every 5 seconds) - ON/OFF
3.1 Exit to main menu
4.1 Exit to main menu and save the new setting.
4.2 Sound VOX detection
- VOX Sound means that it will transmit sounds only when it detects them, based on the setting of the sensitivity level (level 4 being the most sensitive). To save power, after 10 seconds, the sound transmission will stop if no sound is detected. - OFF or 4 level options
4.3 Video VOX detection
- VOX Video means that when Parent Unit is in sleep mode (black screen) the screen will turn ON only when it detects sounds, based on the setting of the sensitivity level (level 4 being the most sensitive). To save power, after the set time, the sleep mode will be activated. - OFF or 4 level options
5.1 Exit to main menu and save the new setting
5.4 Select volume of all songs
6.1 Exit to main menu and save the new setting
Screen may flicker in some lighting environments. Change the frequency to lower the flickering effect 50Hz/60Hz.
7. Termperature Settings
7.1 Exit to m main menu and save new setting.
7.2 High temperature setting
- range 15 to 32 °C / 59 to 90°F
7.3 Low temperature setting
- range 5 to 20 °C / 41 to 68°C (Minimum difference between high and low temperature setting is 4 °C / 7°F) OFF
7.4 Temperature scale
7.5 Temperature Alarm - Use the High & Low temperature settings to determine your
preferred room temperature. -ON/OFF
7.6 Temperature colour alert for the Nursery Unit - use the High & Low temperature
settings to determine your preferred room temperature. -ON/OFF
EG Image - CAM1 is currently being viewed (CAM1 OK is paired, Pad1 pairing option)
8.1 Exit to main menu
8.2 Pairing CAM1 = if it shows ok this means
its paired if showing two arrows, pairing needs to be activated
8.3 it will show Pairing PAD1 or PAD1 OK which means its connected.
- Press any keys to stop alarm and make the alert icon disappeared.
1. Movement Pad alert: If after 20 seconds -there is NO movement detected both the
Parent Unit and Nursery Unit speakers will emit loud consecutive beeps - this is the movement alarm.
2. Movement Pad is paused.
3. Movement Pad lost link: Parent Unit and Nursery Unit speakers will emit loud consecutive
4. Movement Pad battery is low: Parent Unit will emit 3 consecutive beeps, every 5 seconds.
5. Parent Unit is out-of-range: Parent Unit will emit 2 consecutive beeps, every 10 seconds.
6. Temperature is too cold: Parent Unit will emit 3 consecutive beeps, every 5 seconds.
7. Temperature is too hot: Parent Unit will emit 3 consecutive beeps, every 5 seconds.
TROUBLE SHOOTING Visit Angelcarebaby.com and go to the helpcentre to watch troubleshooting videos.
AC25_BabyMovementMonitor_Manual_Final.indd 10AC25_BabyMovementMonitor_Manual_Final.indd 10 2023-07-12 13:472023-07-12 13:47ANGELCARE – Model AC25 | 11 WARNINGS Please follow all of the following safety precautions to prevent any serious injury or death or damage to product. Keep user manual for future reference. Please ensure you read this carefully before installing and using this product.
1. Because of the serious strangulation risk to infant & toddlers, parents & caregivers should note the
– MOVEMENT PAD – NO ALARM
- Sources of vibration & movement, other than your baby’s, can be detected by the Movement Pad and interfere with the performance of your Angelcare monitor.
- The alarm will not sound if it detects movement other than your baby’s.
- High sensitivity settings can pick up other sources of vibration & movement - please read instructions on sensitivity setting to adjust accordingly.
- Other active and older babies (toddlers) in the same room can be detected and the alarm will not sound.
- Ensure the baby’s environment is FREE from any movements or vibrations when using the Movement Pad - see below warnings 3 to 9.
- KEEP the Nursery Unit and adaptor cords OUT of the reach of children more than 1 metre away.
- NEVER use extension cords with adaptors. ONLY use adaptors provided.
- This product is NOT a Toy. NEVER allow children to play with it.
3. DO NOT use a cot mobile and other cot accessories
that may produce movements or vibrations.
4. Fans (including ceiling), washing machines, floor
boards, central heating or loud music are all forms of movement and vibration and may interfere and be detected by the Movement Pad.
5. DO NOT use with bedside cot touching parent’s/
carer’s bed as the Movement Pad will detect your movements.
6. DO NOT place the cot against a wall or skirting
board as vibrations may be detected.
7. Ensure cot is stable to eliminate any movement.
8. Cot should not be placed in reaching distance
of another cot or bed.
9. DO NOT use other wireless devices in the same
room as the monitor (including mobile phones, microwaves...). They may interfere with signal and performance. AC25_BabyMovementMonitor_Manual_Final.indd 11AC25_BabyMovementMonitor_Manual_Final.indd 11 2023-07-12 13:472023-07-12 13:4712 | USER MANUAL10. Avoid moisture contact with Movement Pad - Always use with a dry Mattress so ensure mattress is aired/dryed and rotated (if possible). Dry/clean surfaces of Movement Pad with a dry lint free cloth.11. The Movement Pad is not intended to be used to determine if a child is out of the cot.12. ALWAYS be sure to immediately check on baby whenever an alarm sounds.13. ONLY use the chargers and power adaptors provided. Do not use other types as this may damage the device and battery pack.14. Adult assembly required. Keep small parts away from children when assembling.15. DO NOT touch the plug contacts especially with sharp or metal objects.16. DO NOT use the baby monitor near water. Care should be taken so that objects DO NOT fall onto units and that liquids are not spilled into either unit or Movement Pad through its openings. CAUTION RISK OF ELECTRIC SHOCKDO NOT OPENDO NOT EXPOSE TO RAIN OR MOISTURE17. Keep monitor AWAY from heat sources (such as stoves, radiators, etc.). Heat can damage the case or electrical parts.18. ALWAYS place both the Nursery Unit and the Parent Unit on a flat solid surface in an upright position that allows for proper VENTILATION. DO NOT place on sofas, cushions, beds, etc. which may block ventilation or anywhere that would muffle the sound or interfere with the normal flow of air.
75% 10% 40°C 10°C 45°C 0°C0°COperation and Storage conditionsOperation – The baby monitor can only be used between 10°C and 40°C, max 75% RH. Do not exceed 28°C for long periods of use.Storage – Between 0°C and 45°C, max 75% RH.High-temperature & high humidity environments and including direct sunlight should be avoided – this could lead to potential battery leakage, swelling and potential harm and damage. The parent Unit and Nursery Unit contain Lithium batteries and should be stored safely. Always store the product with approximately 50% PU battery charge and do not store for more than 3 months without charging.
SPECIFIC WARNING Do not ingest the battery, Chemical Burn Hazard. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.Keep out of reach of children Swallowing can lead to chemical burns, perforation of soft tissue, and death. Severe burns can occur within 2 hours of ingestion. Seek medical attention immediately. BATTERY WARNING Symptoms of battery ingestion and insertion are difficult to diagnose. No obvious symptoms Unfortunately, it is not obvious when a button or coin battery is stuck in a child’s oesophagus (food pipe).There are no specific symptoms associated with this. The child might:• cough, gag or drool a lot;• appear to have a stomach upset or a virus;• be sick;• point to their throat or stomach;• have a pain in their abdomen, chest or throat;• be tired or lethargic;• be quieter or more clingy than usual or otherwise “not themselves”;• lose their appetite or have a reduced appetite; and• not want to eat solid food / be unable to eat solid food.These sorts of symptoms vary or fluctuate, with the pain increasing and then subsiding.A specific symptom to button and coin battery ingestion is vomiting fresh (bright red) blood. If the child does this seek immediate medical help.The lack of clear symptoms is why it is important to be vigilant with “flat” or spare button or coin batteries in the home and the products that contain them.20. The Parent Unit battery is a replaceable Li-Ion battery. The Wireless Movement Pad uses a replaceable Button Cell Lithium Battery. Only use the Angelcare recommended replacement battery (see Technical Specification). AC25_BabyMovementMonitor_Manual_Final.indd 12AC25_BabyMovementMonitor_Manual_Final.indd 12 2023-07-12 13:472023-07-12 13:47ANGELCARE – Model AC25 | 13
- Danger of explosion if the wrong battery is used or if replaced incorrectly. Refer to User’s Guide for correct battery installation.
- DO NOT short circuit supply terminals.
21. DO NOT mix old and new batteries and
only use Angelcare recommended replacement batteries (see Technical Specification).
22. Exercise care in handling batteries in order
not to short out the batteries with conducting materials such as rings, bracelets and keys.
23. Overcharging, short circuiting, reverse
charging, mutilation, or incineration of batteries must be avoided to prevent one or more of the following occurrences: release of toxic materials, release of hydrogen and/or oxygen, gas and rise in surface temperature.
24. Incorrect polarity installation of the batteries
in the end product must be avoided. Reverse insertion of batteries can cause charging, and that may result in leakage or explosion.
25. Battery swelling can occur with the type
of battery used in the Parent Unit if not used or stored correctly including but not limited to the age, usage pattern, environmental conditions (over heating),over-charging, over-discharging, using incorrect chargers and physical abuse/ damage. Refer to Angelcare online Battery Warning Statement: https://angelcarebaby.com/battery-safety
26. Remove batteries from units if you store the
product over 30 days because the batteries could leak and damage the product.
27. Discard ‘dead’ batteries as soon as possible
since ‘dead’ batteries are more likely to leak in a product. If a battery has leaked or vented, discard product responsibly.
- Batteries cannot be subjected to high or low extreme temperatures, low air pressure at high altitude during use, storage or transportation as can lead to explosion or the leakage of flammable liquid or gas.
- See technical specification sheet and “Protect the environment”. Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, can result in an explosion.
- The mounting height of the Nursery Unit should be less than 2 meter.
- The applied nameplate is located at the product rear enclosure. IMPORTANT SAFETY INSTRUCTIONS Always lay baby to sleep on his or her back. Avoid over-heating of baby’s surroundings. Do not leave any objects near your baby that may cause suffocation. Objects may also prevent detection of your babies movements.
29. This monitor uses public airwaves to transmit
signals. The Parent Unit may pick up signals or interference from other nursery monitors in your area. Your monitor may even be picked up by other households. To protect your privacy, make sure both units are turned OFF when not in use.
30. Power cord protection - Protect the Adaptor’s
power cord from being walked on or pinched by furniture or other items – Power supply cords should be routed so that they are not likely to be walked on or pinched by items upon or against them, paying particular attention to cords and plugs, convenience receptacle, and the point where they exit from the product. The socket outlet should be installed near the equipment and should be easily accessible. Make sure to plug the adaptor to the socket outlet nearest to the equipment and that is easily accessible. To disconnect from mains, unplug the adaptor. STOP using the Power Adaptor if it gets damaged or broken in any way.
31. Only use attachments/accessories and
replacement parts specified by the manufacturer. Any mounting of the product should follow the manufacturer’s instructions.
- DO NOT position this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious injury to a child or adult and serious damage to the product.
- Use ONLY the stand sold with the product.
- Be sure replacement parts are supplied by Angelcare and have the same characteristics as original part. Unauthourised substitution may result in fire, electric shock or fire.
32. Unplug this appliance during lightning storms
or when not used for long periods of time.
33. Servicing - DO NOT attempt to service
this product yourself as opening or removing covers (except battery door) may expose you to dangerous voltage or other hazards.
- Power Supply – see Technical Specification within this guide.
34. Overloading - DO NOT overload wall
outlets, extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock.
35. Nursery Unit Antenna - The antenna used
for this transmitter must be installed to provide a separation distance of at least 8’’ (20 cm) from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
36. Cleaning - Disconnect all units before cleaning.
DO NOT immerse any part of the monitor in water. Clean only with a dry cloth. AC25_BabyMovementMonitor_Manual_Final.indd 13AC25_BabyMovementMonitor_Manual_Final.indd 13 2023-07-12 13:472023-07-12 13:4714 | USER MANUAL
warrants to the original owner of this product that Angelcare
monitor is free from any material and workmanship defects for the term of the warranty period (see war- ranty table below to determine the warranty for your country). If this monitoring system fails to function properly when used as directed under normal conditions and during the warranty period, Angelcare
will either repair or replace the product, at our discretion, free of charge. Please contact your local distributor to validate warranty and warranty period. The product must be accompanied by a proof of purchase, either a bill of sale or other proof that the monitoring system is within the warranty period. Angelcare
will bear the cost of repairing or replacing the product and shipping it back to you. This warranty does not apply to a product which has been damaged as a result of improper maintenance, an accident, improper voltage supply or any other form of misuse. The warranty is also void if the owner repairs or modifies the product in any way. Angelcare
is not liable for any incidental or consequential damages with regard to this product. The warranty also excludes any liability other than what is stated above. No other warranty is given. This warranty does not cover products and accessories which are not Angelcare
-brand- ed, or any problems that result from usage that is not in accordance with product instruc- tions, failure to follow the product instructions, or problems caused by using accessories, parts or components not supplied by Angelcare. IMPORTANT! This Angelcare
monitor is a personal care product. Please do not return this product to the store. If you have questions or need help, please call your distributor before returning this product. Please contact your local distributor for warranty information. Find your local distributor by visiting our website: https://international.angelcarebaby.com/ Warranty term UK & South Africa 1 year Other countries 2 years AC25_BabyMovementMonitor_Manual_Final.indd 14AC25_BabyMovementMonitor_Manual_Final.indd 14 2023-07-12 13:472023-07-12 13:47ANGELCARE – Model AC25 | 15 TECHNICAL SPECIFICATIONS Range: Open field (Open area without obstructions):
- Between the Nursery Unit and the Parent Unit: up to 150 metres.
- Between the Nursery Unit and the Movement Pad: up to 20 metres. Number of Channels: Europe: 19 channels. Thermometer Guidelines: High Temperature Alarm: 22°C Low Temperature Alarm: 16°C Power Supply: 2 x 100-240VAC/ 5V DC 1.0A Dongguan Guanjin Electronics Technology Co., Ltd. (EU: K05V050100G, UK: K05B050100B, AU: K05B050100A) Adaptors for the Parent Unit and the Nursery Unit. 1 included CR2450 3V battery (Changzhou Jin Tan Chao Chuang Battery Co., Ltd. model number: CR2450H, or GP Batteries International Ltd. model number: CR2450) (wireless Movement Pad). The battery Included for the Parent Unit is Li-Ion battery (HZT755060) 3.7V 3000mAh 11.1Wh manufactured by Shenzhen Hi-Chipcom Electronics Co., Ltd. for the Parent Unit. To obtain information on replacement batteries please contact Angelcare customer service: www.angelcarebaby.com Instructions will be included with the replacement battery. Keep all batteries away from children. Batteries: CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. Transmission: Transmission between the Parent Unit and the Nursery Unit is made on 2.4 GHz frequency. Transmission between the Nursery Unit and the Move- ment Pad is made on 2.4 GHz frequency. Hereby, Angelcare Canada Inc., declares that this Baby Monitor is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.angelcarebaby.com/declaration-of-conformity RF Exposure - This device is designed and manufactured to comply with Radio Frequency (RF) radiation exposure limits for UK for an uncontrolled environment. To maintain the compliance, human exposure to the nursery unit shall not be less than 20 cm during normal operation.
PROTECT THE ENVIRONMENT
The wheelie bin symbols mean that according to local laws and regulations your product and/or its battery shall be disposed of separately from house- hold waste. When the product/battery reaches its end of life take it to a collection point designated by local authorities. The separate disposal and recycling will help conserve natural resources and protect human health and the environment. Refer to User’s Guide for removal of batteries. ErP Compliance For each standby and/or off mode and the condition providing networked standby into which the equipment is switched by the power management function or similar function:
1) The power consumption data in Watt (Parent Unit
off mode with battery fully charged: 0.1W, Baby Unit off mode: 0.1W)
2) The period of time after which the power man-
agement function, or a similar function, switches the equipment automatically into standby and/or off mode and/or the condition providing networked standby: (Not Applicable)
USE ONLY THE FOLLOWING ANGELCARE BRAND
POWER SUPPLY MODEL NUMBERS: EU: K05V050100G UK: K05B050100B AU: K05B050100A See product for compliance marks specific to this device. AC25_BabyMovementMonitor_Manual_Final.indd 15AC25_BabyMovementMonitor_Manual_Final.indd 15 2023-07-12 13:472023-07-12 13:47CONTACT INFORMATION Manufactured by: Angelcare Canada 2000 McGill College Avenue, Suite 250 Montreal (Quebec), H3A 3H3, Canada Learn More To learn more, please visit our help centre angelcarenorthamerica.zendesk.com/hc/en-uk For specific country distributer information please visit : Angelcarebaby.com AC25_BabyMovementMonitor_Manual_Final.indd 16AC25_BabyMovementMonitor_Manual_Final.indd 16 2023-07-12 13:472023-07-12 13:47MANUEL DE L’UTILISATEUR
ManualGo.com