USER MANUAL MC 818 MEDISANA

Please read carefully!

A litre attendant s.v.p.l

Papakaoue diaaogeT E Tpoooxn!

1 Safety Information. 11
2 Useful Information. 15
3 Operating 16
4 Miscellaneous. 18
5 Warranty. 20

FR Mode d'emploi

Massage seat cover
2 4 massage heads
3 Cable
4 Seating area
On/Off button
Button/LED for "Full Back" massage
Button/LED for "Upper Back" massage
Button/LED for "Lower Back" massage
9 Button/LED for heat
10 Button/3 LEDs for automatic switch off after 5/10/15 minutes
Button/3 LEDs for choosing massage intensity
Spot massage button with LEDs (switches spot massage on/off)

FR

Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use.

Should you give this device to another person, it is vital that you also pass on these instructions for use.

MEDISANA MC 818 - FR - 1

Explanation of symbols

This instruction manual belongs to this device. It contains important information about starting up and operation. Read the instruction manual thoroughly. Non-observation of these instructions can result in serious injury or damage to the device.

MEDISANA MC 818 - Explanation of symbols - 1

WARNING

These warning notes must be observed to prevent any injury to the user.

MEDISANA MC 818 - WARNING - 1

CAUTION

These notes must be observed to prevent any damage to the device.

MEDISANA MC 818 - CAUTION - 1

NOTE

These notes give you useful additional information on the installation and operation.

MEDISANA MC 818 - NOTE - 1

Protection category II

LOT

LOT number

MEDISANA MC 818 - Protection category II - 1

Manufacturer

about the power supply

  • Before connecting the device to your power supply, please ensure that the supply voltage stated on the rating plate is compatible with your mains supply.
  • Only connect the mains plug to the wall socket when the device is switched off.
  • Do not operate this unit near high frequency electromagnetic sources.
  • Keep the power cord and the device itself away from heat, hot surfaces, damp and liquids. Avoid touching the plug or power switch with wet or even damp hands, or when you are standing in water.
  • Parts that conduct electricity on the device must not come into contact with liquid.
  • If the device falls into water, do not try to pick it up. Instead pull the plug out immediately.
  • Always make sure that the plug is easily accessible when the device is connected.
  • Disconnect the plug from the socket immediately after using the device.
  • Never pull on the power cord to disconnect the appliance from the mains. Always pull out the mains plug!
  • Do not carry, pull or rotate the device by its power cord.
  • Ensure that the cable will not cause tripping. The cable must not be kinked, trapped or twisted.

specific groups of people

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
    Children shall not play with the appliance.
  • The surface of the appliance is hot. People who are insensitive to heat must be careful when using the appliance.

  • Do not use this unit to supplement or replace medical treatment. Chronic complaints and symptoms may be made worse.

  • You should refrain from using the Tapping massage seat cover MC 818, or should consult your doctor before using it, if

  • you are pregnant,

  • you have a cardiac pacemaker, artificial joints or electronic implants,

  • you suffer from one or more of the following illnesses and complaints: Circulation disorders, varicose veins, open wounds, bruises, broken skin, inflammation of the veins.

  • If you experience any pain or discomfort during the massage, stop immediately and consult your doctor.

before using the unit

  • Always carefully inspect the cable, the control unit and the massage cushion for damage before use. Do not attempt to use a defective unit.

  • Do not use the unit if there are visible signs of damage on the unit or the cable components, the unit does not work properly or the seat or the control unit have been dropped or become damp. In order to prevent hazards, always send the unit in to the service centre.

operating the unit

  • The massage seat cover must only be used for its intended purpose as described in the instruction manual.
  • Using the seat cover for any other purpose invalidates the warranty.
  • Never leave the unit unattended if it is connected to the power supply.
  • Do not allow the massage seat cover to come into contact with pointed or sharp objects.
  • Never put the unit down next to an electric stove or other sources of heat.
  • Do not stand on the unit.

  • Operate the device in an upright position only, never place it flat on the floor.

  • If you feel unwell or experience pain when using the unit, stop the treatment immediately.

MEDISANA MC 818 - operating the unit - 1

The device is only intended for household use and must not be used for commercial or medical purposes. If you have health concerns, consult your doctor before using the Tapping massage seat cover.

MEDISANA MC 818 - operating the unit - 2

The massage seat cover must only be used in enclosed spaces!

MEDISANA MC 818 - operating the unit - 3

Do not use the massage seat cover in damp rooms (e.g. when bathing or showering).

maintenance and cleaning

  • The unit is maintenance free.
  • Do not attempt to repair the unit yourself in the event of any defects. Not only does this render the warranty null and void but you can also run the risk of serious hazards (fire, electric shock, injury). Only have repairs carried out by authorised service points.
  • Cleaning and user maintenance shall not be made by children without supervision.

MEDISANA MC 818 - maintenance and cleaning - 1

Do not wash!

MEDISANA MC 818 - maintenance and cleaning - 2

Do not dry clean!

Thank you very much

Thank you for your confidence in us and congratulations!

You have acquired a MEDISANA quality product with this Tapping massage seat cover MC 818. This unit is designed for massaging the back and upper thigh areas.

We recommend that you carefully read the following information on use and care of the product so that you experience its benefits and enjoy using your MEDISANA Tapping massage seat cover MC 818 for many years.

2.1 Items supplied and packaging

Please check first of all that the device is complete and is not damaged in any way. In case of doubt, do not use the appliance and contact your supplier or your service centre.

The following parts are included:

  • 1 MEDISANA Tapping massage seat cover MC 818 with control unit
  • 1 Instruction manual

MEDISANA MC 818 - Items supplied and packaging - 1

The packaging can be reused or recycled. Please dispose properly of any packaging material no longer required. If you notice any transport damage during unpacking, please contact your supplier without delay.

MEDISANA MC 818 - Items supplied and packaging - 2

WARNING

Please ensure that the polythene packing is kept away from the reach of children! Risk of suffocation!

2.2 In the MEDISANA tapping massage seat cover MC 818 you have a How does modern device for genuine Shiatsu style back massages.

the The MEDISANA tapping massage seat cover MC 818 has four mass
MEDISANA massage heads for tapping massage of the three zones "Upper Back", "Low-
tapping er Back" and "Full Back". Additionally the massage intensity can be set
massage in the 3 levels. The device is equipped with an red light heat function in
seat cover the massage heads. The unique combination of intensive tapping mas
work? massage with heat makes the massage seat cover an effective and relaxing
treatment. Their settings can be comfortably adjusted by means of the
easy-to-handle control unit.

3 Operating

3.1 The use of the tapping massage seat cover will improve your well-being after a stressful day. The massage effect is particularly useful for tense muscles and tired tissue. The unit provides pleasant relaxation for overcoming everyday stress.

3.2 Start-up

Operation

  • Place the massage seat cover on a high chair or armchair and attach it to this by means of the fasteners on the back.
  • Insert plug into the mains socket. Ensure that the power supply is easily accessible.
  • Take a seat on the tapping massage seat cover and familiarise yourself with the functions.

Operating the unit

The MC 818 tapping massage seat cover has two functions for an effective massage: tapping massage and heat. The heat function can only be used together with the tapping massage. Do not use the unit for more than 15 minutes at a time. Depending on the timer adjustment, the unit will switch off automatically after max. approx. 15 minutes. Always allow the unit to cool down fully before you use it again.

3.2

Operation

Use the buttons on control pad to operate the massage seat cover:

  • Switch on the device by pressing On/Off button ⑤. The power LED illuminates.
  • When the "Upper Back" massage button ⑦ is pressed, the LED next to the button illuminates and the tapping massage heads ② move from the "Park" position at the base of the backrest, up to the shoulder area, massaging and relaxing the back with tapping whilst doing so. Once the uppermost position has been reached, the direction the massaging heads is reversed. The heads then travel down to the centre of the back. Once the heads reach this point, the direction is reversed again and then travel up the back again. If you press button ⑦ during the massage, this function is switched off and the massage heads remain stationary in their current position.
  • If you press the "Lower Back" massage button 8, the LED next to the button illuminates. The tapping massage heads 2 travel up and down the lower half of the back. The reversal of the direction takes place when the respective end positions are reached. Pressing button 8 during the massage, switches off this function and the massage heads remain stationary in their current position.
  • If you press the "Full Back" massage button ⑥ the function procedure is similar to pressing buttons ⑦ and ⑧, except that it is for the entire back.
  • You can choose the intensity of the tapping massage at any time by pressing the button ①. At start massage is performed with medium intensity and level indicator LED "M" above the button lights up. Press button ⑩ and the level increases (highest intensity massage LED "H"). Press button again and the lowest intensity level (low intensity massage, LED "L") is switched on.
  • The heat function can be activated at any time with the tapping massage, during which the vibration massage can also be activated. Press the heat button to activate the function; the LED lights up. The heat is radiated through the massage heads. Press the button again to de-activate the heat function; the LED goes out.
  • Press the SPOT button ⑫, the massage heads will stay at their current position and perform the tapping massage until you press button ⑫ again.

3.2 Operation

  • Press the button 10 to adjust the automatic switch off timer (5, 10 or 15 minutes).
  • To switch off the device: Press the On/Off button ⑤. The power LED begins to flash and the massage heads travel back down to the "Park" position. When this position is reached, the LED extinguishes. If you press the On/Off button ⑤ when one of the massage functions is switched on, the heat function just stops immediately. Tapping massage will still be performed while the massage heads travel downwards to the "Park" position. The power LED flashes meanwhile and then extinguishes.
  • After each use, switch the device off using the On/Off switch and remove the plug from the mains socket.

4 Miscellaneous

4.1 Cleaning and maintenance

  • Before cleaning the device, make sure that it is turned off and the mains plug is removed from the socket. Allow the unit to cool down.
  • Only clean the Tapping massage seat cover with a soft cloth slightly dampened with a mild detergent (e.g. soap suds). Under no circumstances should you use aggressive detergents, strong brushes, solvents or alcohol.
  • When cleaning, never immerse the unit in water and make sure that no water gets into the unit.
  • Wait until the device is completely dry before using it again.
  • Undo any kinks in the cable.
  • You should ideally store the device in its original packaging and keep it in a clean, dry place.

4.2 Disposal

MEDISANA MC 818 - Disposal - 1

This product must not be disposed of together with domestic waste.

All users are obliged to hand in all electrical or electronic devices, regardless of whether or not they contain toxic substances, at a municipal or commercial collection point so that they can be disposed of in an environmentally acceptable manner.

Consult your municipal authority or your dealer for information about disposal.

4.3 Technical SpecificationsName and model :MEDISANA Tapping massage seat cover MC 818
Voltage supply :100-240V~ 50/60Hz
Power consumption :approx. 36 W
Automatic switch off :after approx. 5 / 10 / 15 minutes
Operating conditions :only use in dry rooms
Storage conditions :in a cool, dry place
Storage temperature 0 °C - max. 40 °C
Dimensions :approx. 66 x 43 x 15 cm
Weight :approx. 3.4 kg
Article No. :88918
EAN Code :40 15588 88918 9

In accordance with our policy of continual product improvement, we reserve the right to make technical and optical changes without notice.

The current version of this instruction manual can be found under www.medisana.com

Warranty and repair terms

Please contact your supplier or the service centre in case of a claim under the warranty. If you have to return the unit, please enclose a copy of your receipt and state what the defect is.

The following warranty terms apply:

  1. The warranty period for MEDISANA products is three years from date of purchase. In case of a warranty claim, the date of purchase has to be proven by means of the sales receipt or invoice.
  2. Defects in material or workmanship will be corrected free of charge within the warranty period.
  3. Repairs under warranty do not extend the warranty period either for the unit or for the replacement parts.
  4. The following is excluded under the warranty:

a. All damage which has arisen due to improper treatment, e.g. non-observation of the user instructions.
b. All damage which is due to repairs or tampering by the customer or unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the consumer or during transport to the service centre.
d. Accessories which are subject to normal wear and tear.

  1. Liability for direct or indirect consequential losses caused by the unit are excluded even if the damage to the unit is accepted as a warranty claim.

MEDISANA MC 818 - Warranty and repair terms - 1

MEDISANA AG

Jagenbergstraße 19

41468 NEUSS

GERMANY

The service centre address is shown on the attached leaflet.

MEDISANA MC 818 - MEDISANA AG - 1

REMARQUE IMPORTANTE! TOUJOURS CONSERVER!

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : MEDISANA

Model : MC 818

Category : Massage device