Güde 42010100 EU 230V - Compressor

42010100 EU 230V - Compressor Güde - Free user manual and instructions

Find the device manual for free 42010100 EU 230V Güde in PDF.

📄 80 pages English EN Download 💬 AI Question ⚙️ Specs
Notice Güde 42010100 EU 230V - page 23
Pick your language and provide your email: we'll send you a specifically translated version.
SKIP

Frequently Asked Questions - 42010100 EU 230V Güde

User questions about 42010100 EU 230V Güde

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Compressor in PDF format for free! Find your manual 42010100 EU 230V - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 42010100 EU 230V by Güde.

USER MANUAL 42010100 EU 230V Güde

Translation of the original operating instructions Compressor

ENGLISH Please read the instructions carefully before starting the machine.

Compressor420/10/100/230 V
Article no. 50148
Connection 230 V~50 Hz
Motor power 2,2 kW
Max. Motor speed 2850 min-1
Number of cylinders 2-Twin
Suction capacity 380 l/min
Effective delivery quantity 266 l/min
Max. operating pressure 10 bar
Tank capacity 100 l
Weight 72 kg
Protection Type IPX0
Protection Class F
Sound power level LWA*97 dB

Güde 42010100 EU 230V - 1

Güde 42010100 EU 230V - 2

Read and understand the operating instructions before using the appliance. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.

In case of any doubts about connection and operation refer please to our customer center

Preserve all the documentation so that anyone who uses the compressor can consult this beforehand.

Specified Conditions Of Use

The compressor may only be used to produce compressed air at home, on yards and in workshops. - Respecting technical data and safety precautions.

Güde 42010100 EU 230V - 3

The compressed air produced by the

compressor cannot not be used for pharmaceutical, food or medical purpose to fill the air bottles of scuba divers.

Güde 42010100 EU 230V - 4

The compressor must be used in a

suitable environment (well ventilated with an ambient temperature of between +5^ and +40^ ) and never in places with dust, acids, vapors, explosive or flammable gas

Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.

Safety instructions

WARNING! Electric shock! There is a risk of an injury caused by electric shock!

Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA ).

Check the voltage. Technical data given on the type label must correspond with electric network voltage.

Insert the plug of the electrical cable in a socket of suitable shape, voltage and frequency complying with current regulations.

Use extension cables with a maximum length of 5 meters and with a cable cross-section of not less than 1.5mm^2 . Use of extension cables of different length and cross-section and also of adapters and multiple sockets should be avoided.

Check the cable and/or socket for damages before the appliance putting into operation.

To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.

Never let the compressor come into contact with water or other liquids and never direct the jet of liquids sprayed by tools connected to the compressor towards the compressor: as the appliance is live, this could cause electrocution or short-circuits.

Never use the appliance with bare feet or wet hands or feet.

Never yank the power cable to disconnect the plug from the power outlet or to move the compressor.

Warning: the compressor may restart when power is restored following a blackout.

Compressed air is a potentially dangerous form of energy; always take great care when using the compressor and its accessories.

This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the

necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device.

Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorised persons out of reach of the appliance.

Never use the compressor without being supervised.

Never direct the jet of air towards persons, animals or your body.

Never keep the air flow in body holes as that could lead to fatal injuries!

Keep the work area free.

When operating, the compressor must be placed on a stable surface.

Caution! The compressor may only be used with appropriate wheels and rubber bumps.

Safety goggles should be worn when using the compressor in order to protect the eyes against any foreign bodies lifted by the jet of air.

If possible, when using air-powered accessories,

wear safety clothing.

Always maintain a safety distance of at least 4 meters between the compressor and the work area.

Caution! The pneumatic hose may lash you when the quick-acting coupling is opened! The pneumatic hose should be held by hand.

Always use the handle to move the compressor. When using compressed air, you must know and comply with the safety precautions to be adopted for each type of application (inflation, airpowered tools, painting, washing with water-based detergents only, clinching, etc.).

When using compressed air, you must know and comply with the safety precautions to be adopted for each type of application (inflation, airpowered tools, painting, washing with water-based detergents only, clinching, etc.).

Caution! Never switch the compressor on or off using the plug. Pressure switch to be pressed at all times.

Do not leave the compressor on over night as it could become a source of danger.

At the end of your working day, switch the appliance off, release the air jet and unplug the compressor.

Warning: if the water that condenses is not drained, it may corrode the receiver, reducing

its capacity and impairing safety.

As it is a contaminating product, condensate must be DISPOSED of in accordance with laws on protection of the environment and current legislation.

Never leave the appliance exposed to adverse weather conditions (rain, sun, fog, snow).

If this compressor is used outdoors, always remember to stow it after use in a covered or closed place.

Never use the compressor outdoors in rain or bad weather.

Do not place flammable or nylon/fabric objects close to and/or on the compressor.

Do not cover the air inlets on the compressor.

The compressor must not be fitted in a vehicle for industrial purposes without an inspection by an expert!

If the compressor is used for industrial purposes, it must be checked by an expert before putting into operation for the first time. Such check must be ordered by the operator (under BetrSichV Section 17 No.25 - operation safety regulation)

Caution! When fitted in automatic equipment, it is necessary to install appropriate alarm or warning devices in case of power outage or malfunction or compressor (e.g. feed line, etc.) failure.

Keep unused machinery and tools safely in a dry place out of the reach of children.

Operation of compressed air tools

To guarantee perfect and reliable operation of the rotary and percussive pneumatic tools such as impact wrenches, staplers or nailers, etc., the compressed air must be supplied filtered - with oil via the lubricator or maintenance unit

A filtered water separator should be used for varnishing in any case.

To select a suitable pneumatic tool, the tool air consumption and the compressor effective amount delivered must necessarily be considered.

(Pneumatic tools and accessory equipment can be found at www.guede.com)

Operation at lower temperatures

At lower temperatures, below 5^ , problems may be experienced when starting. They are manifested by growling of the electric motor. In such a case, the appliance must be immediately switched off and oil (5W30) changed in warmer conditions.

Requirements for operating staff

The operating staff must carefully read the Operating Instructions before using the appliance.

Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.

Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.

Training: Using the appliance only requires corresponding training by a professional or the Operating

Instructions. No special training is necessary.

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of information:

  1. Accident site
  2. Accident type
  3. Number of injured persons
  4. Injury type(s)

Disposal

The disposal instructions are based on the icons placed on the appliance or on the package. Description of the respective meanings can be found in the section "Marking".

Transport packaging disposal

The packaging protects the appliance against damage during transport. Packaging materials are usually chosen according to environmental-friendliness and waste treatment aspects and can therefore be recycled. Returning the packaging to material circulation saves raw materials and reduces waste. Parts of packaging (e.g. foils, styrofoam) can be dangerous to children.

Risk of suffocation!

Keep the packaging out of reach of children

and dispose them as quickly as possible.

Maintenance

Before carrying out any work on the machine, disconnect the plug from the socket. Run the accessory connected dry until there is no more air in the receiver.

Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.

Safety valve Functional check.

The machine must not be used under any circumstances if the machine or the safety devices are damaged.

Use only original accessories and original spare parts.

Never clean the machine and its components with solvents, flammable or toxic liquids. Us only a damp cloth making.

Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.

If necessary, a list of spare parts can be found at www.guede.com.

Guarantee

Warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device.

The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.

The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.

Service

Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:

Serial No.:

Art. No:

Year of production:

Important information for the customer

Please be sure to know that returning the product in or after the warranty period must be made in the original packaging.

Symbols

Güde 42010100 EU 230V - Symbols - 1

Read the Operating Instructions

Güde 42010100 EU 230V - Symbols - 2

Wear eye protective goggles! Wear ear protectors!

Güde 42010100 EU 230V - Symbols - 3

Protect against humidity Never expose tool to rain.

Güde 42010100 EU 230V - Symbols - 4

Cable pulling / transport prohibited

Güde 42010100 EU 230V - Symbols - 5

Warning/caution

Güde 42010100 EU 230V - Symbols - 6

Dangerous voltage

Güde 42010100 EU 230V - Symbols - 7

Caution - hot surface! Danger of burns!

Güde 42010100 EU 230V - Symbols - 8

Danger - automatic control (closed loop)

Güde 42010100 EU 230V - Symbols - 9

Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.

Güde 42010100 EU 230V - Symbols - 10

Protect against humidity

Güde 42010100 EU 230V - Symbols - 11

This side up

Failure removal

Failures Causes Removal
Compressor not starting after being switched onPressure in the air jet exceeds the closing pressureRelease the pressure in the air jet so that the pressure switch gets automatically switched on
Defective supply Have the current supply checked by an authorised person
Defective pressure switch Have the pressure switch replaced by an authorised person (Güde service centre)
Worn carbons Replace the carbons
After reaching the closed pressure, the compressor runs or buzzes for a short time and then switches off automaticallyElectric cable is too long or its cross section is too smallCheck the length and cross section of the electric cable
Compressor running constantly Suction filter is very dirty Clean or replace the suction filter
Pneumatic tools have high air consumptionCheck the pneumatic tool air consumption; seek an authorised compressed air dealer
Leaking on the compressor Localise the leaking, contact the Güde service centre
Compressed-air pipeline leaking Contact the Güde service centre
Drain valve is open or missing Close or insert the drain valve
Compressed air is released from the discharge valve under the pressure switch when the appliance is being operatedDischarge valve is leaking Clean or replace the discharge valve
After reaching the cut-off pressure, air is released from the discharge valve under the pressure switch until the closing pressure is reachedCheck valve insert is leaking or defectiveClean or replace the check valve insert →16
Check valve is damaged Replace the check valve
Compressor gets started too often Too much condensate in the air jet Drain the condensate
Compressor is overloaded
Safety valve blowing off Pressure in the air jet exceeds the set cut-off pressureHave the pressure switch adjusted/replaced by an authorised person (Güde service centre)
Safety valve is defectiveReplace the safety valve or contact the Güde service centre
Compressor getting warm too muchAir supply is not sufficientMake sure sufficient air supply and outlet (minimum distance from wall is 40 cm) is provided
Cooling fins on the cylinder (cylinder head) are dirtyClean the cooling fins on the cylinder (cylinder head)
Too long time of appliance operationSwitch the compressor off
Compressor being overheated and keeps switching offCompressor is overloadedContact the Güde service centre
Compressor is defectiveContact the Güde service centre
Compressor under undervoltage Contact the Güde service centre
Outdoor temperature of 35°C

Données techniques

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Güde

Model : 42010100 EU 230V

Category : Compressor