USER MANUAL CLPB600IPG2 Cameo

INFORMATION ON THIS USER MANUAL 6

INTENDED USE 6

DEFINITIONS AND SYMBOLS 6

SAFETY INSTRUCTIONS 7

NOTES ON PORTABLE OUTDOOR DEVICES 11

PACKAGING CONTENT 11

INTRODUCTION 11

CONNECTIONS, OPERATING AND DISPLAY ELEMENTS 13

OPERATION 14

INSTALLATION 27

FROST FILTER 32

GLARE SHIELD 32

CARE, MAINTENANCE AND REPAIR 33

OPTIONAL ACCESSORIES 34

DIMENSIONS (mm) 35

TECHNICAL DATA 36

EXPLANATIONS ON IP RATING 38

MINIMUM DISTANCE TO ILLUMINATED SURFACE 39

MINIMUM DISTANCE TO NORMALLY FLAMMABLE MATERIALS 39

DISPOSAL 39

MANUFACTURER'S DECLARATIONS 40

DEUTSCH

ACCESSIONS EN OPTION 10

DIMENSIONS (mm) 10

CHARACTERISTIQUES TECHNIQUES 10

EXPLICATION DE LA CLASSE DE PROTECTION IP 11

DISTANCE MINIMALE PAR RAPPORT A LA SURFACE ECLAIREE 11

DISTANCE MINIMALE PAR RAPPORT AUX MATÉRIAUX NORMALEMENT 11

INFLAMMABLES 11

MISEAU REBUT 11

Déclarations DU FABRICANT 11.

CONTENTS / INHALTSVERZEICHNIS / CONTENU / CONTENIDO / TREŚC / CONTENO

ESPANOL

You have made the right choice!

This device has been developed and manufactured to the highest quality standards to ensure many years of problem-free operation. Please read this user manual carefully to be able to use your new Cameo product quickly and optimally. Further information about Cameo Light is availab- le on our website CAMEOLIGHT.COM.

INFORMATION ON THIS USER MANUAL

  • Carefully read the safety instructions and the entire manual before operating the device.
  • Observe the warnings on the device and in the user manual.
  • Always keep the user manual within reach.
  • If you sell or pass on the device, it is important that you also include this user manual, as it is an integral part of the product.

INTENDED USE

The product is a device for event technology!

This product has been developed for professional use in the field of event technology and is not suitable for use as domestic lighting!

Furthermore, this product is only intended for qualified users with specialist knowledge of event technology!

Use of the product outside the specified technical data and operating conditions is considered improper use!

Liability for damage and third-party damage to persons and property due to inappropriate use is excluded!

The product is not suitable for:

  • Use by persons (including children) with limited physical, sensory or mental abilities or lack of experience and knowledge.
  • Children (children must be instructed not to play with the device).

DEFINITIONS AND SYMBOLS

  1. DANGER: The word DANGER, possibly in combination with a symbol, indicates immediately dangerous situations or conditions for life and limb.
  2. WARNING: The word WARNING, possibly in combination with a symbol, indicates potentially dangerous situations or conditions for life and limb.
  3. CAUTION: The word CAUTION, possibly in combination with a symbol, is used to indicate situations or conditions that may lead to injury.
  4. ATTENTION: The word ATTENTION, possibly in combination with a symbol, refers to situations or states that can lead to damage to property and/or the environment.

Cameo CLPB600IPG2 - DEFINITIONS AND SYMBOLS - 1

This symbol identifies hazards that can cause electric shock.

Cameo CLPB600IPG2 - DEFINITIONS AND SYMBOLS - 2

This symbol identifies hazardous areas or hazardous situations.

Cameo CLPB600IPG2 - DEFINITIONS AND SYMBOLS - 3

This symbol indicates hazards caused by hot surfaces.

Cameo CLPB600IPG2 - DEFINITIONS AND SYMBOLS - 4

This symbol indicates hazards caused by intense light sources.

Cameo CLPB600IPG2 - DEFINITIONS AND SYMBOLS - 5

This symbol indicates a device in which there are no user-replaceable parts.

Cameo CLPB600IPG2 - DEFINITIONS AND SYMBOLS - 6

This symbol indicates additional information on the operation of the product.

SAFETY INSTRUCTIONS

Cameo CLPB600IPG2 - SAFETY INSTRUCTIONS - 1

DANGER:

  1. Do not open or modify the unit.
  2. If your device no longer functions properly, if liquids or objects get inside it or if it has been damaged in any other way, switch it off immediately and disconnect it from the mains. The device may be repaired only by authorised repair technicians.
  3. For devices of protection class 1, the protective conductor must be connected correctly. Never disconnect the protective conductor. Devices of protection class 2 do not have a protective conductor.
  4. Ensure that live cables are not kinked or otherwise mechanically damaged.
  5. Never bypass the unit fuse.

Cameo CLPB600IPG2 - DANGER: - 1

WARNING:

  1. The device may not be operated if it shows obvious signs of damage.
  2. The device may only be installed in a voltage-free state.
  3. If the power cable of the device is damaged, do not operate the device.
  4. Permanently connected power cables may only be replaced by a qualified person.

Cameo CLPB600IPG2 - WARNING: - 1

ATTENTION:

  1. Do not operate the unit if it has been exposed to large temperature fluctuations (for example, after transport). Moisture and condensation can damage the device. Switch on the device only when it has reached room temperature.
  2. Make sure that the voltage and frequency of the mains supply correspond to the values indicated on the unit. If the device has a voltage selector switch, do not connect the device until it has been set correctly. Use only suitable power cables.
  3. To disconnect the unit from the mains at all poles, it is not sufficient to press the on/off switch on the unit.
  4. Make sure that the fuse used corresponds to the type printed on the unit.
  5. Make sure that appropriate measures have been taken against overvoltage (e.g. lightning strike).
  6. Observe the specified maximum output current on units with Power Out connection. Ensure that the total current consumption of all connected devices does not exceed the specified value.
  7. Replace pluggable mains cables only with original cables.

Cameo CLPB600IPG2 - ATTENTION: - 1

DANGER:

  1. Danger of suffocation! Plastic bags and small parts must be kept out of reach of persons (including children) with reduced physical, sensory or mental capabilities.
  2. Danger from falling down! Make sure that the device is securely installed and will not fall down. Only use suitable stands or mounts (particularly for fixed installations). Ensure that accessories are properly installed and secured. Ensure that applicable safety regulations are observed.

Cameo CLPB600IPG2 - DANGER: - 1

WARNING:

  1. Use the device only in the manner intended.
  2. Operate the device only with the accessories recommended and intended by the manufacturer.
  3. During installation, observe the safety regulations applicable in your country.
  4. After connecting the unit, check all cable routes to avoid damage or accidents, e.g. due to tripping hazards.
  5. Always observe the specified minimum distance to normally flammable materials! Unless explicitly stated, the minimum distance is 0.3m .
  6. Always observe the minimum distance to the illuminated surface that can be read on the device!

Cameo CLPB600IPG2 - WARNING: - 1

CAUTION:

  1. In the case of moving components such as mounting brackets or other moving components, there is a possibility of jamming.
  2. In the case of units with motor-driven components, there is a risk of injury from the movement of the unit. Sudden movement of the device can cause shock reactions.
  3. The housing surface of the device can become very hot during regular operation. Ensure that accidental touching of the housing is not possible. Always allow the lamp to cool sufficiently before removal, maintenance work and charging etc.

Cameo CLPB600IPG2 - CAUTION: - 1

ATTENTION:

  1. Do not install or operate the device near any radiators, heat registers, stoves or other heat sources. Ensure that the device is always installed in such a way that it is sufficiently cooled and cannot overheat.
  2. Do not place ignition sources such as burning candles near the device.
  3. Ventilation openings must not be covered and fans must not be blocked.
  4. Use the original packaging or packaging provided by the manufacturer for transport.
  5. Avoid shock or impact to the unit.
  6. Observe the IP rating as well as the ambient conditions such as temperature and humidity according to the specification.
  7. Devices can be constantly further developed. In the event of deviating information on operating conditions, performance or other device properties between the user manual and the device labelling, the information on the device always takes priority.
  8. The unit is not suitable for tropical climates and for operation above 2000m above sea level.
  9. Unless explicitly stated, the unit is not suitable for operation in marine conditions.

Cameo CLPB600IPG2 - ATTENTION: - 1

PLEASE NOTE:

For conversion or retrofit sets or accessories provided by the manufacturer, it is essential to observe the instructions included.

Cameo CLPB600IPG2 - PLEASE NOTE: - 1

CAUTION! IMPORTANT INFORMATION REGARDING LIGHTING PRODUCTS!

  1. Never look directly into the beam of light, not even for a short period of time.
  2. Never look into the beam of light using optical devices such as a magnifying glass.

Cameo CLPB600IPG2 - CAUTION! IMPORTANT INFORMATION REGARDING LIGHTING PRODUCTS! - 1

  1. Stroboscopic effects may cause epileptic seizures in susceptible individuals!

Cameo CLPB600IPG2 - CAUTION! IMPORTANT INFORMATION REGARDING LIGHTING PRODUCTS! - 2

  1. Permanently installed lamps are built into these lighting units. These may not be replaced by the user. In the event of a fault, please contact your distribution partner.

Cameo CLPB600IPG2 - CAUTION! IMPORTANT INFORMATION REGARDING LIGHTING PRODUCTS! - 3

SIGNAL TRANSMISSION AND CONTROL BY RADIO (e.g. W-DMX or audio radio systems, Bluetooth):

The quality and performance of wireless signal transmissions generally depends on the ambient conditions.

The following factors can impact range and signal stability, for example:

Shielding (e.g. masonry, metal structures, water)

High volumes of radio traffic (e.g. powerful wireless LAN networks)

Interference

Electromagnetic radiation (e.g. LED video screens, dimmers)

All range specifications refer to free-field application with visual contact and without interference!

The operation of transmission systems is subject to official regulations. These may vary from region to region and must be checked by the operator before use (e.g. radio frequency and transmission power).

Cameo CLPB600IPG2 - SIGNAL TRANSMISSION AND CONTROL BY RADIO (e.g. W-DMX or audio radio systems, Bluetooth): - 1

WARNING: Devices with wireless signal transmission are not suitable for use in sensitive areas in which radio operation can lead to potential detrimental effects. These include e.g.:

  • Hospitals, health centres or other healthcare facilities that provide patient treatment with skilled personnel and equipment.
  • Hazardous areas Class I, II and III
  • Restricted areas
    Military facilities
  • Aircraft or vehicles
  • Areas where the use of mobile phones is prohibited

Cameo CLPB600IPG2 - SIGNAL TRANSMISSION AND CONTROL BY RADIO (e.g. W-DMX or audio radio systems, Bluetooth): - 2

TRANSMISSION VIA W-DMX

WARNING: In general, wireless DMX transmission must not be used for applications with safety-related factors that could result in personal injury or property damage in the event of failure.

This applies in particular to moving scene or traverse structures, DMX-controlled motors/lifts or lifting devices for operating DMX-operated platform lifts, hydraulic systems or comparable moving components.

Furthermore, wireless DMX transmission must not be used to trigger flame or pyrotechnic devices, explosion-driven effects, or to control gas or liquid effects. These include e.g. C02 cannons, confetti shooters, water effects or similar.

Cameo CLPB600IPG2 - TRANSMISSION VIA W-DMX - 1

NOTES ON PORTABLE OUTDOOR DEVICES

  1. Temporary operation! Event equipment is generally only designed for temporary operation.
  2. Continuous operation or permanent structural installation – particularly outdoors – can impair the function, surfaces and seals and accelerate material fatigue.
  3. Damage to the surface coating can impair the device's corrosion protection. Damaged surface coating (e.g. scratches) must be promptly repaired by suitable measures.

PACKAGING CONTENT

Remove the product from the packaging and remove all packaging material.

Please check the completeness and integrity of the delivery and notify your distribution partner immediately after purchase if the delivery is not complete or if it is damaged.

Included with the CLPB400IPG2 product are:

1 x_PIXBAR® 400 IP65 G2 RGBW spotlights
2 sliding mounting feet with folding SPIN16^® mounting spigot (pre-assembled)
1 x standard frost filter
1 x glare shield
1x power cable
User manual

Included with the CLPB600IPG2 product are:

1 x PIXBAR® 600 IP65 G2 RGBWAuv spotlights
2 sliding mounting feet with folding SPIN16® mounting spigot (pre-assembled)
1 x standard frost filter
1 x glare shield
1x power cable
User manual

INTRODUCTION

PIXBAR® 400 IP G2 Outdoor Spotlights

CLPB400IPG2 with 16 4in1 RGBW LEDs

PIXBAR® 600 IP G2 Outdoor Spotlights

CLPB600IPG2 with 16 6in1 RGBWAUV LEDs

CONTROL FUNCTIONS:

CLPB400IPG2

1-channel, 3-channel Preset, 4-channel Direct, 7-channel Direct Control, 8-channel 16-bit, 10-channel Direct CCT, 11-channel Effect Pattern, 16-channel Wash, 36-channel Pattern, 48-channel Pixel RGB, 64-channel Pixel, 68-channel Pixel Dim, D2-channel, D4-channel Preset and D7-channel Direct DMX Control

CLPB600IPG2

1-channel, 3-channel Preset, 6-channel Direct, 9-channel Direct Control, 12-channel 16-bit, 12-channel Direct CCT, 13-channel Effect Pattern, 20-channel Wash, 44-channel Pattern, 48-channel Pixel RGB, 96-channel Pixel, 100-channel Pixel Dim, D2-channel, D4-channel Preset and D9-channel Direct DMX Control

RDM

W-DMXTM

Master/Slave modes

Stand-alone functions

FEATURES:

IP65 Rating
- Convection cooling
- Operating voltage: 100 - 240 VAC

The spotlights feature the RDM standard (remote device management). This remote device management enables the status query and configuration of RDM end devices via an RDM-capable controller, such as the optionally available Cameo UNICON (item number CLIREMOTE). The Cameo UNICON also allows access to the entire spotlight menu.

CONNECTIONS, OPERATING AND DISPLAY ELEMENTS

Cameo CLPB600IPG2 - CONNECTIONS, OPERATING AND DISPLAY ELEMENTS - 1

  • The CLPB400IPG2 and CLPB600IPG2 models feature identical connections, operating and display elements -

1 POWER IN

IP65 mains input socket with rubber sealing cap (TRUE1 compatible). Operating voltage 100 - 240 VAC / 50 - 60 Hz. Connection via supplied power cable (when not in use, always close with rubber sealing cap).

2 POWER OUT

IP65 mains output socket with rubber sealing cap (TRUE1 compatible). Facilitates power supply to other CAMEO spotlights. Ensure that the total current consumption of all connected devices does not exceed the value specified on the device in amperes (A) (when not in use, always close with the rubber sealing cap).

3 DMX IN

Male IP65 5-pin XLR socket for connecting a DMX control device (e.g. DMX console, when not in use always

close with the rubber sealing cap).

4 DMX OUT

Female IP65 5-pin XLR socket for sending DMX control signal (when not in use, always close with the rubber sealing cap).

5 OLED DISPLAY

The OLED display shows the currently activated operating mode or the current DMX address (main display), the menu items in the menu and the numerical value or operating mode in certain menu items.

6 TOUCH-SENSITIVE CONTROLS

MENU- Press MENU to access the main menu. Press again or repeatedly to return to the main display.

UP and DOWN – Select the menu items in the main menu (DMX address, operating mode, etc.) and in the sub-menus using UP and DOWN. Change value or status in a menu item, e.g. DMX address. To quickly change a value, such as the DMX start address, press and hold UP or DOWN.

ENTER - Press ENTER to access the menu level to make value or status changes, and to access one of the sub-menus. Confirm value or status changes by pressing ENTER.

Cameo CLPB600IPG2 - TOUCH-SENSITIVE CONTROLS - 1

PLEASE NOTE:

  • Before navigating the unit menu, make sure that the control panel is dry and clean so that its functionality is not impaired.
  • Water on the control unit can lead to incorrect operation of the spotlight, e.g. in outdoor operation. Therefore, after configuring the spotlight, activate the lock function to prevent incorrect operation by water (Settings -> Display -> Autolock).

7 PRESSURE EQUALISATION ELEMENT

Pressure equalisation element to prevent condensation inside the housing. In order to ensure its proper function, the element must be protected from contamination.

W-DMXTM ANTENNA

Antenna for control via W-DMX™.

Cameo CLPB600IPG2 - W-DMXTM ANTENNA - 1

ATTENTION: To ensure IP65 splash resistance for the DMX and network sockets, the special input and output sockets must be correctly sealed with the IP65 special plugs or the rubber sealing caps must be used for sealing. When connected correctly, or when sealed correctly with the rubber sealing caps, the POWER IN and POWER OUT sockets are protected from spraying water, as in accordance with IP65.

OPERATION

NOTE

  • As soon as the spotlight is correctly connected to the power supply, the following are displayed in succession: "Update wait ..." (for service purposes only), "Welcome to Cameo", the model name and the software version. After this process, the spotlight is ready for operation and the previously activated operating mode is launched.
  • If there is no input for approx. 30 seconds, the display automatically returns to the main display.

  • Note on the main display in the operating modes with external control: As soon as the control signal is interrupted, the characters in the display start flashing; if the control signal is present again, the flashing stops.

  • Briefly pressing UP when in the main display rotates the display by 180^ .

SETTING DMX START ADDRESS (DMX address)

Starting from the main display, press MENU to enter the main menu. Now use UP and DOWN to select the menu item DMX Address and confirm with ENTER. Using the UP and DOWN buttons, configure the desired DMX start address and press ENTER to confirm (highest value dependent upon activated DMX mode).

Cameo CLPB600IPG2 - SETTING DMX START ADDRESS (DMX address) - 1

Cameo CLPB600IPG2 - SETTING DMX START ADDRESS (DMX address) - 2

Cameo CLPB600IPG2 - SETTING DMX START ADDRESS (DMX address) - 3

CONFIGURING DMX MODE (DMX Mode)

Starting from the main display, press MENU to enter the main menu. Now use UP and DOWN to select the menu item DMX Mode and confirm with ENTER. Now select the desired DMX mode using UP and DOWN and confirm the selection with ENTER. DMX operating modes with DMX delay channel and group selection (Group 0 - 24) are marked with "D". Tables with the channel assignments can be found in these instructions under DMX CONTROL.

Cameo CLPB600IPG2 - CONFIGURING DMX MODE (DMX Mode) - 1

Cameo CLPB600IPG2 - CONFIGURING DMX MODE (DMX Mode) - 2

Cameo CLPB600IPG2 - CONFIGURING DMX MODE (DMX Mode) - 3

DMX modes with DMX delay channel

The DMX Delay function is a simple way to create a running light effect with a large number of spotlights that are all the same model and that are all running the same software version. This is otherwise only achievable with a suitable DMX controller and time-consuming programming. All the spotlights used (same models, same software version) are set to the same DMX operating mode with DMX delay channel and controlled via the same DMX start address.

Setting the DMX delay: Select one of the DMX operating modes with DMX delay channel and confirm the selection (in the example D4 CH Preset). Assign the spotlights to one of up to 24 groups (plus Group 0) according to preference, whereby several spotlights can be assigned to one group. The group number is also the factor by which the set delay time set in the DMX controller is multiplied. Confirm each entry by pressing ENTER.

Cameo CLPB600IPG2 - DMX modes with DMX delay channel - 1

Cameo CLPB600IPG2 - DMX modes with DMX delay channel - 2

Cameo CLPB600IPG2 - DMX modes with DMX delay channel - 3

The delay time (delay time of the DMX signal) is set by means of a DMX controller in the separate DMX delay channel of the corresponding DMX mode (0.0s to 2.0s in 0.1s increments).

Setup example:

Cameo CLPB600IPG2 - DMX modes with DMX delay channel - 4

In the stand-alone modes Direct LED, Color Preset, CCT, HSI, Auto Program and Play Loop, the control signal of the corresponding mode can be output to slave units via XLR (DMX OUT) and W-DMXTM:

Stand Alone -> Master/Alone -> Master

If the output of the control signal is not desired, the output can be deactivated:

Stand Alone -> Master/Alone -> Alone

A delay for slave units can be set for the time-delayed output of the control signal of the stand-alone modes Auto Program and Play Loop.

Starting from the main display, press MENU to enter the main menu. Now select the Stand Alone menu item, confirm, select Master/Alone and confirm again.

Cameo CLPB600IPG2 - DMX modes with DMX delay channel - 5

Cameo CLPB600IPG2 - DMX modes with DMX delay channel - 6

This will take you to the menu for configuring the menu items (see table).

MasterSend to XLRControl signal is forwarded via DMX OUT
Send to W-DMXOnActivate DMX control signal forwarding via W-DMX
OffDeactivate sending of the DMX control signal via W-DMX
Force to pairPairing with ready-to-pair W-DMX devices
Unlink AllDisconnect all W-DMX connections
DMX DelaySet DMX delay for slave units: Off, 0.1s - 2.0s
AloneDo not forward control signal

STAND-ALONE DIRECT LED MODE

The stand-alone Direct LED mode allows dimmer, strobe, R, G, B and W (CLPB400IPG2) or R, G, B, W, A and UV (CLPB600IPG2) to be set directly on the unit, similar to a DMX controller. In this way, an individual scene can be created without an additional DMX controller.

Starting from the main display, press MENU to enter the main menu. Use UP and DOWN to select Stand Alone, confirm with ENTER, then select Direct LED and confirm again with ENTER. Now select the menu item you want to edit, confirm the selection, set the desired value and confirm the entry.

Cameo CLPB600IPG2 - STAND-ALONE DIRECT LED MODE - 1

Cameo CLPB600IPG2 - STAND-ALONE DIRECT LED MODE - 2

Cameo CLPB600IPG2 - STAND-ALONE DIRECT LED MODE - 3

Cameo CLPB600IPG2 - STAND-ALONE DIRECT LED MODE - 4

COLOUR PRESET STAND-ALONE MODE

49 different colour presets plus eight individually adjustable user presets (see Edit User Color) are available. The brightness can be set at a higher level. Starting from the main display, press MENU to enter the main menu. Use UP and DOWN to select the menu item Stand Alone, confirm the selection, then select Color Preset and confirm again with ENTER. Now select GEL or User Color and confirm the selection. The desired preset can now be selected, confirm the selection. Now select Dimmer (brightness), confirm the selection and make the settings as desired. Confirm the entry.

Cameo CLPB600IPG2 - COLOUR PRESET STAND-ALONE MODE - 1

Cameo CLPB600IPG2 - COLOUR PRESET STAND-ALONE MODE - 2

Cameo CLPB600IPG2 - COLOUR PRESET STAND-ALONE MODE - 3

CCT STAND-ALONE MODE (Correlated Colour Temperature)

In stand-alone CCT mode, the colour temperature can be adjusted in 100K steps from 2200K to 8000K, plus the hue (tint) and brightness (dimmer). Starting from the main display, press MENU to enter the main menu. Use UP and DOWN to select the Stand Alone menu item, confirm the selection, then select CCT and confirm again with ENTER. Now select the menu item you want to edit, confirm the selection and make the settings as desired. Confirm the entry.

Cameo CLPB600IPG2 - CCT STAND-ALONE MODE (Correlated Colour Temperature) - 1

Cameo CLPB600IPG2 - CCT STAND-ALONE MODE (Correlated Colour Temperature) - 2

Cameo CLPB600IPG2 - CCT STAND-ALONE MODE (Correlated Colour Temperature) - 3

STAND-ALONE MODE HSI (Hue - Saturation - Intensity)

In the stand-alone HSI mode, the hue, saturation and brightness can be adjusted separately as desired. Starting from the main display, press MENU to enter the main menu. Use UP and DOWN to select the Stand Alone menu item, confirm the selection, then select HSI and confirm again with ENTER. Now select the menu item you want to edit, confirm the selection and make the settings as desired. Confirm each entry.

Cameo CLPB600IPG2 - STAND-ALONE MODE HSI (Hue - Saturation - Intensity) - 1

Cameo CLPB600IPG2 - STAND-ALONE MODE HSI (Hue - Saturation - Intensity) - 2

Cameo CLPB600IPG2 - STAND-ALONE MODE HSI (Hue - Saturation - Intensity) - 3

STAND-ALONE OPERATION MODE PLAY LOOP (8-step colour sequences 1 - 8)

The 8 available loops are pre-programmed at the factory, but can be customised in the Edit Loop menu item. The brightness can be set at a higher level. Starting from the main display, press MENU to enter the main menu. Using UP and DOWN, select the menu item Stand Alone, confirm with ENTER, then select the submenu item Auto and confirm again with ENTER. Now select the menu item you want to edit, confirm the selection and make the settings as desired. Confirm each entry.

Cameo CLPB600IPG2 - STAND-ALONE OPERATION MODE PLAY LOOP (8-step colour sequences 1 - 8) - 1

Cameo CLPB600IPG2 - STAND-ALONE OPERATION MODE PLAY LOOP (8-step colour sequences 1 - 8) - 2

Cameo CLPB600IPG2 - STAND-ALONE OPERATION MODE PLAY LOOP (8-step colour sequences 1 - 8) - 3

TIMER FUNCTION

The timer function allows timed control of the Direct LED, Colour Preset, CCT and HSI stand-alone modes in such a way that the fade-in time (Fade In) can be set from 0 to 60 minutes, the dwell time from 1 to 24 hours and the fade-out time from 0 to 60 minutes. After activation of the timer function, the timer control will be implemented upon the next system start. Starting from the main display, press MENU to enter the main menu. Select Stand Alone, confirm the selection, then select Timer and confirm again. Select the setting On under Timer and confirm. For the individual timer control settings, select Fade In, Dwell Time or Fade Out and confirm. You can now set the respective value as desired. Confirm all entries. To deactivate the timer function, select the setting Off under Timer and confirm the entry.

Note: The timer function is suitable for use in master/slave operation via cable and W-DMX™.

Cameo CLPB600IPG2 - TIMER FUNCTION - 1

Cameo CLPB600IPG2 - TIMER FUNCTION - 2

Cameo CLPB600IPG2 - TIMER FUNCTION - 3

EDITING USER-PRESETS (Edit User Color)

The eight user presets available in the stand-alone mode Colour Preset can be edited individually. Starting from the main display, press MENU to enter the main menu. Using UP and DOWN you now select the menu item Stand Alone, confirm with ENTER, then select Edit User Color and confirm once again. Select the desired preset (UserID 1 - 8) and confirm the selection. Now decide which way you want to create the colour for the preset and select one of the four methods Direct, CCT, Preset and HSI and confirm the selection. Now set the desired colour as described in the instructions for the respective stand-alone mode.

Cameo CLPB600IPG2 - EDITING USER-PRESETS (Edit User Color) - 1

Cameo CLPB600IPG2 - EDITING USER-PRESETS (Edit User Color) - 2

Cameo CLPB600IPG2 - EDITING USER-PRESETS (Edit User Color) - 3

Cameo CLPB600IPG2 - EDITING USER-PRESETS (Edit User Color) - 4

EDIT LOOP (Edit LOOP)

Brightness, step duration and fade time can be set separately for all eight loops. Starting from the main display, press MENU to enter the main menu. Using UP and DOWN you now select the menu item Stand Alone, confirm with ENTER, then select Edit Loop and confirm once again. Now select the desired loop for editing and confirm the selection.

Cameo CLPB600IPG2 - EDIT LOOP (Edit LOOP) - 1

Cameo CLPB600IPG2 - EDIT LOOP (Edit LOOP) - 2

Cameo CLPB600IPG2 - EDIT LOOP (Edit LOOP) - 3

Cameo CLPB600IPG2 - EDIT LOOP (Edit LOOP) - 4

This will take you to the menu for configuring the menu items (see table). The settings for each loop are made separately and are retained even after restarting the device.

Step1 - 8Step selection
T-StepT-Step 0s - 10s = 0,1s steps 10s - 1min = 1s steps 1min - 20min = 1min stepsSetting the step duration for the selected step
T-FadeT-Fade 0s - 10s = 0,1s steps 10s - 1min = 1s steps 1min - 20min = 1min stepsSetting the fade time for the selected step
Color PresetStep 1 + 2: Dark Magenta - Rose Pink, User Color 1 - 8, BlackoutSelecting the colour preset or blackout for the selected step
Step 3 - 8: Dark Magenta - Rose Pink, User Color 1 - 8, Blackout, Skip StepSelect the colour preset or blackout or skip the selected step

EZ REMOTE CONTROL VIA CAMEO UNICON (optionally available)

Starting from the main display, press MENU to enter the main menu. Using UP and DOWN you now select the EZ Remote menu item and confirm by pressing ENTER. Now set the desired fixture ID (Fixture ID 1 - 8) and confirm the entry. Connect the spotlight and UNICON using a DMX cable, select DMX Control in the UNICON menu, then EZ Remote, and enter the same unit ID. Now control the spotlight using RGB, GEL, CCT or HSI. By assigning different unit IDs, up to eight spotlights (or spotlight groups) can be controlled separately via UNICON.

Fixture ID 1-8

Menu DMX Address DMX Mode Stand Alone EZ Remote Slave Settings Service System Info

SLAVE MODE

Standard slave operation: Starting from the main display, press MENU to enter the main menu. Using the UP and DOWN buttons, you now select the menu item Slave confirm with ENTER, select the Slave Group 0 and confirm again with ENTER. Connect the slave and master units (same model, same software version) using a DMX cable or W-DMXTM and activate one of the stand-alone modes (Direct LED, Color Preset, CCT, HSI, Auto Program, Play Loop) in the master unit. The slave unit will now follow the master unit.

Extended slave operation: If you want to control the slave units by one of the stand-alone modes Auto Program or Play Loop in master / slave operation, the control signal can be played back with a time delay of up to 24 steps, the delay is set in the Stand Alone menu Master/Alone in the master unit, the delay factor in the slave menu of the corresponding fixture (Group). This is a simple way to create a running light effect with a large number of spotlights that are all the same model and have the same software version. This is otherwise only possible using a suitable DMX controller and time-consuming programming. Connect the slave and master units (same model, same software version) using a DMX cable or via W-DMX™

Menu DMX Address DMX Mode Stand Alone EZ Remote Slave Settings Service System InfoSlave Group Receive ModeGroup0 - 24Set slave group for signal delay
Receive ModeXLR (permanent aktiv)
OnActivate W-DMX module
OffDeactivate W-DMX module
UnlinkDisconnect all con-nections and place in pairing standby mode

Assign the spotlights to one of up to 24 groups (plus Group 0) according to preference, whereby several spotlights can be assigned to one group. The group number is also the factor by which the delay time set in the master unit is multiplied.

Setup example:

Cameo CLPB600IPG2 - SLAVE MODE - 1

SYSTEM SETTINGS (Settings)

Starting from the main display, press MENU to enter the main menu. Using the UP und DOWN buttons you now select the menu item Settings and confirm with ENTER.

Cameo CLPB600IPG2 - SYSTEM SETTINGS (Settings) - 1

This will take you to the submenu for setting thesubmenu items (see table, select with UP and DOWN, confirm with ENTER, change value or status with UP and DOWN, confirm with ENTER).

Wireless=Wireless settingsW-DMX StateOnActivate W-DMX
OffW-DMX deactivated
Operating ModeReceiveW-DMX mode: Receiver
TransmitG3 (G3 transmission standard)
G4s (transmission standard G4s )
LinkingUnlinkUncouple all units and make them ready for coupling
Link/Force to pairPair with W-DMX devices. W-DMX must be enabled on all devices, and the pairing with a transmitter be retained (Receive Reset).
Signal RoutingSend to XLRSend incoming signal to XLR connector
Backup by XLRUsing the incoming signal from the XLR connector when the W-DMX signal is lost.
Receive onlyNo connection between W-DMX signal and XLR connectors
Display=Display settingsReverseOnDisplay is rotated by 180° (e.g. for over-head installation)
OffNo display rotation
Off TimerAlways OnDisplay lighting permanently on
Off after 20sDeactivation of the display lighting after approx. 20 seconds of inactivity
AutolockOffFunction disabled
On after 60sThe controls and display are locked after approx. 60 seconds without any operation. Unlock: Press UP and DOWN simultaneously for approx. 5 seconds
Dimmer=Dimming behaviour and PWM frequencyCurveLinearDimmer curve: The light intensity increas-es linearly with the DMX value
ExponentialDimmer curve: The light intensity can be adjusted finely in the lower DMX value range and coarsely in the upper DMX value range
LogarithmicDimmer curve: The light intensity can be adjusted coarsely in the lower DMX value range and finely in the upper DMX value range
CurveS-CurveLight intensity can be finely adjusted at lower and higher DMX values and broadly adjusted at medium DMX values
Dimmer=Dimming behaviour and PWM frequencyPWM Fre-quency650 Hz, 1530 Hz, 3600 Hz, 12 kHz, 18.9 kHz, 25 kHzSelect LED PWM frequency
ResponseLEDLight responds abruptly to changes in DMX value
HalogenLight behaves like a halogen spotlight with slight brightness changes
RedshiftDim to Warmaccurately mimics the colour drift of dim- ming a halogen spotlight. When dimming the spotlight, the colour temperature changes automatically to increasingly warm white tones and amber (and vice versa).
OffFunction disabled
Color Cal- istration=Colour calibra-tionRAWR, G, B, and W (CLPB400IPG2) or R, G, B, W, A and Uv (CLPB600IPG2) with maxi-mum value 255
UserCLPB400I-PG2: RGBW CLPB600I-PG2: RGB-WAUvIndividual colour calibration. Cross-mode brightness setting with values from 0-255
FactoryFactory calibration (cross-mode)
SmartMerging factory and RAW calibration
Signal Fail=Operating mode on control signal interruptionHoldLast command is retained
Last Stand AloneLast activated stand-alone mode is started
Fade to Black (10s)10s fade to blackout
BlackoutInstant blackout
User Color 1User Colour 1 is activated
FullFull On
Pixel Mirror=Mirror pixelOffFunction disabled
OnPixels are mirrored
Store Default=Store all system settings in 3 individual presetsUser AStore with ENTER
User BStore with ENTER
User CStore with ENTER

SERVICE MENU (Service)

Starting from the main display, press MENU to enter the main menu. Select Service using UP and DOWN and confirm with ENTER.

Menu DMX Address DMX Mode Stand Alone EZ Remote Slave Settings Service System Info

Information on the menu items in the service menu and the corresponding options can be found in the table below (select with UP and DOWN, confirm with ENTER, change value or status with UP and DOWN, confirm with ENTER).

Load DefaultFactoryReset to factory setting
User AReset to User A values (Save user values: Settings -> Store Default)
User BReset to User B values (Save user values: Settings -> Store Default)
User CReset to User C values (Save user values: Settings -> Store Default)
Reset Service TimerNoCancel operation
Reset nowReset service operation time
PasswordFor service purposes only

SYSTEM INFORMATION (System Info)

Starting from the main display, press MENU to enter the main menu. Select System Info using UP and DOWN and confirm with ENTER.

Menu DMX Address DMX Mode Stand Alone EZ Remote Slave Settings Service System Info

Information on the submenu items in the system info menu and the corresponding options can be found in the table below (select with UP and DOWN, confirm with ENTER, change value or status with UP and DOWN, confirm with ENTER).

FirmwareDISPVx.x.xDisplay of the firmware version of the corresponding component
DRVVx.x.x
TemperatureLEDxxx °C / °FDisplay of the temperature of the corresponding component
Temperature Unit°CSetting the temperature unit
°F
RuntimeTotalxxxx h : xx mTotal operating time
Operationxxxx h : xx mUsable time
LEDxxxx h : xx mLamp operating time
Servicexxxx h : xx mOperating time after resetting the service operating time
RDM-UIDRDM Unique Identifier

INSTALLATION

Cameo CLPB600IPG2 - INSTALLATION - 1

DANGEROverhead mounting requires extensive experience, including the calculation of the load limit values of the installation material and regular safety inspection of all installation materials and spotlights. If you do not have these qualifications, do not attempt to perform an installation yourself. Refer instead to a qualified professional. There is a risk that devices that are incorrectly mounted and secured may come loose and fall down. This can cause serious injury or death.

The unique coupling mechanism means that when several PIXBAR^® G2 are docked, there is also a uniform pixel spacing at the transitions from one to the next PIXBAR^® G2.

Cameo CLPB600IPG2 - INSTALLATION - 2

Thanks to the adjustable stand or mounting feet, the PIXBAR® G2 can be set up in a suitable position on a flat floor (e.g. as an upright).

MOUNTING A_PIXBAR® ON A TRUSS

Mounting on a truss is done using optionally available truss clamps, which are either attached directly to the mounting feet (1), or to optionally available Omega mounting brackets (part number CLOMEGABRACKET1). The mounting feet can be moved on the housing of the PIXBAR® G2. To do this, loosen the middle of the five hexagon socket screws (2), move the foot to the desired position and tighten the screw again. The direction of radiation can be adjusted using the tommy screws (3) on the mounting feet. Ensure that the connections are tight and that the PIXBAR® G2 cannot come loose. When mounting the PIXBAR® G2 overhead, secure it with a suitable safety rope to one of the safety lugs provided (4). When mounting several docked PIXBAR® G2 horizontally overhead, each individual PIXBAR® G2 must be attached separately to the truss with the mounting feet and secured with a suitable safety rope.

Cameo CLPB600IPG2 - MOUNTING A_PIXBAR® ON A TRUSS - 1

USE SPIN16 TV SPIGOT FOR MOUNTING

The mounting feet of the PIXBAR® G2 have 16 mm TV spigots that can be extended and retracted without tools. To unfold a TV spigot, pull the spring-loaded locking bolt out of the locking hole in the direction of the arrow (1), fold the TV spigot forwards and let the locking bolt engage in the locking hole offset by 90^ (2). Use suitable truss clamps for mounting. Ensure that the connections are tight and that the headlamp cannot come loose. When mounting the headlamp overhead, secure it with a suitable safety rope to one of the safety lugs provided (see marking).

Cameo CLPB600IPG2 - USE SPIN16 TV SPIGOT FOR MOUNTING - 1

Cameo CLPB600IPG2 - USE SPIN16 TV SPIGOT FOR MOUNTING - 2

Cameo CLPB600IPG2 - USE SPIN16 TV SPIGOT FOR MOUNTING - 3

VERTICAL HANGING MOUNTING ON A TRUSS

For vertical hanging mounting, up to three PIXBAR® G2 may be connected to each other. The following optionally available products must be used for this:

A suitable truss clamp with sufficient load-bearing capacity for the total load (e.g. half coupler).
One Omega Bracket (item number CLO-MEGABRACKET1).
3 One stop set (item number CLPBG2VER-TIMOUNT).
One or two connecting elements are needed to connect two or three PIX BAR® G2 and to secure the connection (item number CLPBG2STACKKIT).

The safety eyelet of the top foot of the top bar serves as a safety point. Make sure that the safety rope used to secure the bars is suitable for the total weight of the bars.

For optical reasons, the mounting feet can be folded to the side of the housing. A rubber buffer prevents the surface from being damaged.

Cameo CLPB600IPG2 - VERTICAL HANGING MOUNTING ON A TRUSS - 1

VERTICAL FLOOR MOUNTING

For vertical floor mounting, a maximum of two PIXBAR® G2 may be connected to each other. The following optionally available products must be used for this:

One connector (item number CL-PBG2STACKKIT).
One stop set (item number CLPBG2VER-TIMOUNT).
3 One M20 connection set (item number CLPBG2M20ADA).
A heavy steel stand with M20 thread and sufficient stability for the total load.

The stability in combination with the stand used must be assessed by the user. No additional loads may be introduced.

For optical reasons, the mounting feet can be folded to the side of the housing. A rubber buffer prevents the surface from being damaged.

Cameo CLPB600IPG2 - VERTICAL FLOOR MOUNTING - 1

Cameo CLPB600IPG2 - VERTICAL FLOOR MOUNTING - 2

Cameo CLPB600IPG2 - VERTICAL FLOOR MOUNTING - 3
2

Cameo CLPB600IPG2 - VERTICAL FLOOR MOUNTING - 4

Cameo CLPB600IPG2 - VERTICAL FLOOR MOUNTING - 5

Cameo CLPB600IPG2 - VERTICAL FLOOR MOUNTING - 6
4

VERTICALLY SUSPENDED TRUSS

Cameo CLPB600IPG2 - VERTICALLY SUSPENDED TRUSS - 1

VERTICAL FLOOR MOUNTING

Cameo CLPB600IPG2 - VERTICAL FLOOR MOUNTING - 1

FROST FILTER

A standard frost filter is included with the PIXBAR® G2. To insert the frost filter into the holder provided for it 1 of the bar, open the sliding latch at one end of the bar (2, slide down the handle). After inserting the frost filter into the holder, close the latch again to prevent the filter from falling out.

Cameo CLPB600IPG2 - FROST FILTER - 1

Cameo CLPB600IPG2 - FROST FILTER - 2

GLARE SHIELD

A glare shield is included with the PIXBAR® G2. On both sides of the PIXBAR® G2 there are three threads on the top edge of the housing 1. Mount the glare shield on the desired side of the PIXBAR® G2 using the three knurled screws 2.

Cameo CLPB600IPG2 - GLARE SHIELD - 1

CARE, MAINTENANCE AND REPAIR

In order to ensure the long-term, proper functioning of the device, it must be regularly cleaned and, if necessary, maintained. The maintenance requirement depends on the intensity of use and the environment in which it is used.

We generally recommend a visual inspection before each operation. Furthermore, we recommend carrying out all the applicable maintenance measures specified below once every 500 operating hours or, in the case of a lower intensity of use, at the latest after one year. Warranty claims may be limited in the event of defects resulting from inadequate maintenance.

CARE (carried out by user)

Cameo CLPB600IPG2 - CARE (carried out by user) - 1

WARNING! Before carrying out any care or maintenance, the power supply – and, if possible, all device connections – must be disconnected.

Cameo CLPB600IPG2 - CARE (carried out by user) - 2

PLEASE NOTE! Improper care can lead to impairment of the device or even its destruction.

  1. Housing surfaces must be cleaned with a clean, damp cloth. Make sure that no moisture can penetrate the device.
  2. Air inlets and outlets must be regularly cleaned of dust and dirt. If compressed air is used, make sure that damage to the device is prevented (e.g. fans must be blocked in this case, as they could otherwise over-rev.).
  3. Lines and plug contacts must be cleaned regularly and dust and dirt must be removed.
  4. In general, no cleaning agents or abrasive agents may be used, otherwise the surface finish may be damaged.
  5. Devices must generally be stored dry and protected from dust and dirt.
  6. To ensure correct and safe operation, all accessible or removable lenses and light-emitting apertures must be cleaned regularly.

MAINTENANCE AND REPAIR (by qualified personnel only)

Cameo CLPB600IPG2 - MAINTENANCE AND REPAIR (by qualified personnel only) - 1

DANGER! There are live components in the unit. Even after disconnecting the mains connection, there may still be residual voltage in the device, for example, due to charged capacitors.

Cameo CLPB600IPG2 - MAINTENANCE AND REPAIR (by qualified personnel only) - 2

PLEASE NOTE! There are no user-serviceable assemblies in the device.

Cameo CLPB600IPG2 - MAINTENANCE AND REPAIR (by qualified personnel only) - 3

PLEASE NOTE! Maintenance and repair work may only be carried out by sufficiently qualified specialist personnel. If in doubt, consult a specialist workshop.

Cameo CLPB600IPG2 - MAINTENANCE AND REPAIR (by qualified personnel only) - 4

PLEASE NOTE! Improperly performed maintenance work may affect the warranty claim.

Cameo CLPB600IPG2 - MAINTENANCE AND REPAIR (by qualified personnel only) - 5

PLEASE NOTE! For conversion or retrofit sets provided by the manufacturer, be sure to observe the enclosed installation instructions.

OPTIONAL ACCESSORIES

CLPBG2FILTER55

55^ frost filter

CLPBG2FILTER70

70^ frost filter

CLPBG2FILTER2555

25^ × 55^ Frost filter

CLPBG2STACKKIT

Connecting element for the secure mechanical connection of two PIXBAR® G2

CLPBG2VERTIMOUNT

Stop set for mounting a PIXBAR® G2 on the Omega mounting bracket CLOMEGABRACKET1 and for mounting on the connection set CLPBG2M20ADA

CLOMEGABRACKET1

Omega mounting bracket

CLPBG2M20ADA

Connection set for mounting a PixBar G2 on a stand with M20 thread

Cameo CLPB600IPG2 - CLPBG2M20ADA - 1

Cameo CLPB600IPG2 - CLPBG2M20ADA - 2

Cameo CLPB600IPG2 - CLPBG2M20ADA - 3

Cameo CLPB600IPG2 - CLPBG2M20ADA - 4

TECHNICAL DATA

Item numberCLPB400IPG2CLPB600IPG2
Product categoryLED lightLED light
TypeLED barsLED bars
Light source16 x 4in1 RGBW16 x 6in1 RGBWAUV
Luminous flux6500lm @ 6300K; R: 2500lm; G: 3600lm; W: 570lm; W: 5000lm5300lm @ Full On; R: 1580lm; G: 2755lm; B: 427lm; W: 3175lm; A: 1753; UV: n/a
Lens / optic16 x Acrylic Lens16 x Acrylic Lens
PWM Frequency650 Hz/ 1530 Hz/ 3600 Hz/ 12000 Hz/ 18900 kHz/ 25000 kHz650 Hz/ 1530 Hz/ 3600 Hz/ 12000 Hz/ 18900 kHz/ 25000 kHz
Dimmer response8 / 16 bit8 / 16 bit
Dimmer curvesLinear, exponential, s-curve, loga-rithmicLinear, exponential, s-curve, logarithmic
Halogen simu-lationYesYes
Strobe0 Hz - 20 Hz0 Hz - 20 Hz
CRI>84 @ 5600K77
Beam Angle 22°/ Field Angle 38° 1.25°/42°24°/46°
LED colourR: 625nm; G: 518nm; B 545nm; W: 6036KR: 635nm; G: 519nm; B: 448nm; W: 6100K; A: 602nm; UV: 400nm
Colour mixingRGBWRGBWAUV
Color control modesRGBW Direct; CCT + Tint; HSI; Colour PresetsRGBWAUV Direct; CCT + Tint; HSI; Colour Presets
CCT 000-2552200K - 8000K2200K - 8000K
Colour Calibra-tionRaw; factory; smartRaw; factory; smart
Control protocolsDMX; RDM; Wireless; Stand-Alone; Master-Slave; EZ-RemoteDMX; RDM; Wireless; Stand-Alone; Master-Slave; EZ-Remote
Data connections5-pin XLR in/out IP65; Wireless DMX5-pin XLR in/out IP65; Wireless DMX
DMX mode1CH; 3CH; 4CH; 7CH; 8CH; 10CH; 11CH; 16CH; 36CH; 48CH; 64CH; 68CH; D2CH; D4CH; D7CH1CH; 3CH; 6CH; 9CH; 12CH; 13CH; 20CH; 44CH; 48CH; 96CH; 100CH; D2CH; D4CH; D9CH
DMX functions:Dimmer; Dimmer fine; Strobe Functions; Red; Red fine; Green; Green fine; Blue; Blue fine; White; White fine; Color Temperature; Tint; Color Presets; Color Preset Crossfade; Selection Folder; Pattern; Pattern Speed;Dimmer; Dimmer fine; Strobe Functions; Red; Red fine; Green; Green fine; Blue; Blue fine; White; White fine; Amber; Amber fine; UV; UV fine; Color Temperature; Tint; Color Presets; Color Preset Crossfade; Selection Folder; Pattern; Pattern Speed; Pattern Transi- tion; Running Effect Pattern;
DMX functions:Pattern Transition; Running Effect Pattern; Background Dimmer; Back- ground Dimmer fine; Background Strobe Functions; Background Red; Background Red fine; Background Green; Background Green fine; Background Blue; Background Blue; Background Blue fine; Background White; Background White fine; Background Color Tem- perature; Background Color Tint; Back- ground Color Macro; Background Macro Crossfade; Device Settings; Grouping; DMX-Delay (EZ-Chase); Pixel: R1, G1, B1, W1,... R16, G16, B16, W16Background Dimmer; Background Dimmer fine; Background Strobe Func- tions; Background Red; Background Red fine; Background Green; Back- ground Green fine; Background Blue; Background Blue fine; Background White; Background White fine; Back- ground Amber; Background Amber fine; Background UV; Background UV fine; Background Color Temperature; Background Tint; Background Color Macro; Background Macro Crossfade; Device Settings; Grouping; DMX-Delay (EZ-Chase); Pixel: R1, G1, B1, W1, A1, Uv1,... R16, G16, B16, W16, A16, Uv16
DMX functions:Cameo standard RDM functionsCameo standard RDM functions
StandaloneAuto; Static; CCT; HSI; Colour Preset; Play Loop; Slave; TimerAuto; Static; CCT; HSI; Colour Preset; Play Loop; Slave; Timer
System SettingsWireless; Display Reverse; Display off Timer; Autolock; Signal Fail; Dimmer Curve; Dimmer Response; Redshift; PWM Frequency; Color Calibration; Load Default; Store Default; ServiceWireless; Display Reverse; Display off Timer; Autolock; Signal Fail; Dimmer Curve; Dimmer Response; Redshift; PWM Frequency; Color Calibration; Load Default; Store Default; Service
User interface4-button navigation (MENU/ENTER/UP/DOWN)4-button navigation (MENU/ENTER/UP/DOWN)
LC DISPLAY2 row OLED2 row OLED
Power rating:IP65 for outdoor useIP65 for outdoor use
Ambient tem- perature rating (in operation)T -20°C - 45°C (unit operational) -10°C - 45°C (display operational)T -20°C - 45°C (unit operational) -10°C - 45°C (display operational)
Humidity100% to 80% (non-condensing)100% to 80% (non-condensing)
Cooling systemPassive convection, fanlessPassive convection, fanless
Noise levelNoise freeNoise free
Operation voltage100–240 VAC / 50–60 Hz100–240 VAC / 50–60 Hz
Max. current0.77 A @ 230 V / 1.62 A @ 110 V0.77 A @ 230 V / 1.62 A @ 110 V
Inrush currentAA
Max power consumption180 V, 230 V, 110 V180 V, 230 V, 110 V
STANDBY LED9 W9 W
Power connectorsSeetronic IP65 In + OutSeetronic IP65 In + Out
POWER LEDUp to 9 units @ 230 V; up to 5 units @ 110 VUp to 9 units @ 230 V; up to 5 units @ 110 V
Minimum distance to the illuminated surface0.3 m0.3 m
Minimum distance to normal flammable materials0.017 m0.017 m
HousingString cast aluminium, black powder coatedString cast aluminium, black powder coated
Dimensions w/h/d1018 mm (1000 mm when units are linked) x 206 mm x 178 mm1018 mm (1000 mm when units are linked) x 206 mm x 178 mm
Weight11.8 kg11.8 kg
RDM UID0x08A4004C 0000-FFFF0x08A4004D 0000-FFFF

EXPLANATIONS ON IP RATING

  1. An IP rating only reflects protection from solid objects and water. It does not describe general weather resistance, such as protection from UV radiation and temperature, etc.

  2. The first identification digit indicates protection from dust, solid objects and contact:

IP2XProtected against solid foreign bodies ≥ 12.5 mm in diameter
IP3XProtected against solid foreign bodies ≥ 2.5 mm in diameter
IP4XProtected against solid foreign bodies ≥ 1.0 mm in diameter
IP5XProtected against dust in harmful quantities and completely protected against contact
IP6XAre dust-tight and completely protected against contact
  1. The second identification digit indicates protection from water:
IPX0No protection
IPX1Protection against dripping water
IPX2Protection against dripping water when the device is tilted up to 15°
IPX3Protection against falling spray water up to 60° from the vertical
IPX4Protection against splashing water on all sides
IPX5Protection against water jets (nozzle) from any angle
IPX6Protection against strong water jets
IPX7Protection against temporary immersion
  1. In addition, some device-specific measures such as covers and sealing caps are necessary in order to achieve the specified rating (e.g. protective caps on unused connections).

Cameo CLPB600IPG2 - EXPLANATIONS ON IP RATING - 1

The IP rating of the product can be found in the technical data and is printed on the device.

MINIMUM DISTANCE TO ILLUMINATED SURFACE

This symbol with distance information in metres (m) indicates the minimum distance of the luminaire to the illuminated surface. In this example, the distance is 0.5m . The value valid for this unit can be found in the technical data in this manual and in the imprint on the unit housing!

MINIMUM DISTANCE TO NORMALLY FLAMMABLE MATERIALS

Cameo CLPB600IPG2 - MINIMUM DISTANCE TO NORMALLY FLAMMABLE MATERIALS - 1

This symbol with distance indication in metres (m) indicates the minimum distance of the appliance to normally flammable materials. In this example, the distance is 0.5m . For the value valid for this unit, please refer to the technical data in this manual!

DISPOSAL

Cameo CLPB600IPG2 - DISPOSAL - 1

PACKAGING:

  1. Packaging can be fed into the reusable material cycle using the usual disposal methods.
  2. Please separate the packaging in accordance with the disposal laws and recycling regulations in your country.

Cameo CLPB600IPG2 - PACKAGING: - 1

DEVICE:

  1. This appliance is subject to the European Directive on Waste Electrical and Electronic Equipment as amended. WEEE Directive Waste Electrical and Electronic Equipment. Old appliances do not belong in household waste. The old device must be disposed of via an approved disposal company or a municipal disposal facility. Please observe the applicable regulations in your country!
  2. Observe all disposal laws applicable in your country.
  3. As a private customer, you can obtain information on environmentally-friendly disposal options from the seller of the product or the appropriate regional authorities.

MANUFACTURER'S DECLARATIONS

Manufacturer's warranty & limitation of liability

Adam Hall GmbH | Adam-Hall-Str.1 | 61267 Neu-Anspach | Germany

E-mail: Info@adamhall.com / +49 (0)6081 / 9419-0.

Our current warranty conditions and limitation of liability can be found at:

https://cdn-shop.adamhall.com/media/pdf/Manufacturers-Declarations-CAMEO_DE_EN_ES_FR.pdf

For service requests, please contact your distribution partner.

CE conformity

Adam Hall GmbH hereby confirm that this product meets the following guidelines (where applicable):

Low-Voltage Directive (2014/35/EU)

EMC Directive (2014/30/EU)

RoHS (2011/65/EU)

RED (2014/53/EU)

EC Declaration of Conformity

Declarations of conformity for products subject to the LVD, EMC, RoHS Directive can be requested from info@adamhall.com.

Declarations of conformity for products subject to RED can be downloaded from www.adamhall.com/compliance/.

Subject to misprints and errors, as well as technical or other modifications!

DEUTsCH

Stand Alone -> Master/Alone -> Master

Stand Alone -> Master/Alone -> Alone

https://cdn-shop.adamhall.com/media/pdf/Manufacturers-Declarations-CAMEO_DE_EN_ES_FR.pdf

Stand Alone -> Master/Alone -> Master

Stand Alone -> Master/Alone -> Alone

CLPB400IPG2CLPB600IPG2
MenuStand AloneDirect LEDDimmer 0% - 100%
DMX AddressMaster/AloneRed 0% - 100%Red 0% - 100%
DMX ModeDirect LEDGreen 0% - 100%Green 0% - 100%
Stand AloneColor PresetBlue 0% - 100%Blue 0% - 100%
EZ RemoteCCTWhite 0% - 100%White 0% - 100%
SlaveHSI
SettingsPlay Loop
ServiceTimer
System InfoEdit User Color Edit Loop

MODE AUTONOME COLOUR PRESET

Stand Alone Master/Alone Direct LED
Color Preset
CCT
HSI
Play Loop
Timer
Edit User Color
Edit Loop
Color Preset
Dimmer 0% - 100%
GEL
User Color

MODE AUTONOME CCT (Correlated Color Temperature)

Stand Alone Master/Alone Direct LED Color Preset
CCT
HSI
Play Loop
Timer
Edit User Color
Edit Loop
CCT
Dimmer0% - 100%
CCT2200K - 8000K
Tint-10 - 10

MODE AUTONOME HSI (Hue - Saturation - Intensity)

Slave Group Receive Mode

https://cdn-shop.adamhall.com/media/pdf/Manufacturers-Declarations-CAMEO_DE_EN_ES_FR.pdf

Directive CEM (2014/30/UE)

RoHS (2011/65/EU)

RED (2014/53/EU)

Table of contents Cliquez un titre pour y accéder
Manual assistant
Powered by ChatGPT
Waiting for your message
Product information

Brand : Cameo

Model : CLPB600IPG2

Category : Projector